Lighting Sciences

Similar documents
Lighting Sciences, Inc.

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

NVLAP LAB CODE:

NVLAP LAB CODE:

TEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.

NVLAP LAB CODE:

NVLAP LAB CODE:

NVLAP LAB CODE:

NVLAP LAB CODE:

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ.

Number Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000

TEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003

Calibration Due Date Chroma Programmable AC Source 61604

Equipment Used Model No Stock No Calibration Due Date

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Revolution Lighting 4139 Guardian St. Simi Valley CA 93063

IESNA LM79: 2008 Photometric Test Report

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Client submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary.

IESNA LM79: 2008 Photometric Test Report

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063

IESNA LM79: 2008 Photometric Test Report

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

IESNA LM79: 2008 Photometric Test Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

BARTCO Lighting 5761 Research Drive, Huntington Beach, CA 92649

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Eternal Shine Technology Co.,Ltd. EST

REVOLUTION LIGHTING TECHNOLOGIES INC

Checked X.CAO

Checked X.CAO

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ c

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE Jersey Blvd. Rancho Cucamonga, CA 91730

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary

71332 LED Dusk To Dawn (Area Light)

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

Photometric Test Report

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

752 North State St, #208, Westerville, OH Photosynthetically active radiation (PAR) & Electrical measurement

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Test Sample Description Catalog Number: Description:

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Photometric Test Report

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

Photometric Indoor Test Report

IESNA LM79: 2008 Photometric Test Report

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

Photometric Test Report

IESNA LM79: 2008 Photometric Test Report

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

Photometric Test Report

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

1120 Goffle Road Hawthorne NJ Photometric/Colorimetric/Electrical Test

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

Report No.: HZ d

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

IESNA LM79: 2008 Photometric Test Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Myles Standish Blvd.

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

Transcription:

Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY ANGLE MEAN CP LUMENS 0 453 5 445 42 10 419 15 387 108 20 353 25 323 148 30 285 35 164 103 40 71 45 55 42 50 38 55 19 17 60 4 65 0 1 70 0 75 0 0 80 0 85 0 0 90 0 ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LUMINAIRE 0-30 298 64.67 0-40 401 86.93 0-60 460 99.78 0-90 461 100.00 40-90 60 13.07 60-90 1 0.22 90-180 0 0.00 0-180 461 100.00 EFFICACY (LUMENS PER WATT): 30.4 *** THIS IS AN ABSOLUTE TEST *** LUMINOUS DIAMETER: 6.000 INS LUMINANCE SUMMARY CD./SQ.M. S/MH: 1.0 SC: 0.9 CERTIFIED BY: ANGLE MEAN CD/SQ M 45 4307 DATE: 55 1792 APR 22, 2010 65 58 PREPARED FOR: 75 22 RAB LIGHTING 85 10 NORTHVALE, NJ TESTED IN ACCORDANCE WITH IES PROCEDURES.

INTENSITY(CANDLEPOWER) DATA IN 2.5 DEGREE STEPS ANGLE INTENSITY LUMENS (CANDLEPOWER) 0.0 453 2.5 451 5.0 445 42 7.5 433 10.0 419 12.5 404 15.0 387 108 17.5 370 20.0 353 22.5 338 25.0 323 148 27.5 308 30.0 285 32.5 230 35.0 164 103 37.5 103 40.0 71 42.5 62 45.0 55 42 47.5 48 50.0 38 52.5 28 55.0 19 17 57.5 10 60.0 4 62.5 1 65.0 0 1 67.5 0 70.0 0 72.5 0 75.0 0 0 77.5 0 80.0 0 82.5 0 85.0 0 0 87.5 0 90.0 0

AVERAGE LUMINANCE DATA CD./SQ.M (FOOTLAMBERTS) ANGLE LUMINANCE 0 24809 ( 7241) 30 18012 ( 5257) 40 5112 ( 1492) 45 4307 ( 1257) 50 3267 ( 953) 55 1792 ( 523) 60 406 ( 118) 65 58 ( 17) 70 26 ( 7) 75 22 ( 6) 80 30 ( 8) 85 10 ( 2)

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE =.20 CC 90 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 1.221.221.221.22 1.191.191.191.19 1.161.161.161.16 1.111.111.11 1.061.061.06 1.021.021.02 1.00 1 1.161.131.111.09 1.141.111.091.07 1.121.091.071.05 1.051.041.02 1.011.000.99 0.980.970.96 0.94 2 1.111.071.030.99 1.091.051.010.98 1.071.031.000.97 1.000.970.95 0.970.950.93 0.940.920.91 0.89 3 1.061.000.950.91 1.040.980.940.90 1.020.970.930.90 0.950.910.88 0.920.890.87 0.900.880.86 0.84 4 1.010.940.880.85 1.000.930.880.84 0.980.920.870.83 0.900.860.83 0.880.840.82 0.860.830.81 0.79 5 0.970.880.820.78 0.950.870.820.78 0.930.860.810.78 0.850.800.77 0.830.790.76 0.820.780.76 0.74 6 0.920.830.770.74 0.910.820.770.73 0.890.820.760.73 0.800.760.72 0.790.750.72 0.780.740.71 0.70 7 0.870.780.720.69 0.860.770.720.68 0.850.770.710.68 0.750.710.67 0.740.700.67 0.730.690.67 0.65 8 0.830.740.680.64 0.820.730.670.63 0.810.720.670.63 0.710.660.63 0.700.660.63 0.690.650.62 0.61 9 0.790.690.630.59 0.780.690.630.59 0.770.680.630.59 0.670.620.59 0.660.620.58 0.650.610.58 0.57 10 0.750.650.590.55 0.740.650.590.55 0.730.640.590.55 0.630.580.55 0.630.580.55 0.620.580.55 0.53 THE ABOVE COEFFICIENTS HAVE BEEN CALCULATED BASED ON LUMINAIRE LUMENS BECAUSE IN AN ABSOLUTE TEST THE BARE LAMP LUMENS ARE UNKNOWN. LIGHTING DESIGN CALCULATIONS MADE USING THESE COEFFICIENTS SHOULD THEREFORE USE THE LUMINAIRE LUMENS IN THE CALCULATION FORMULA LUMINAIRE INPUT WATTS 15.2 LABORATORY RESULTS MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST AND FIELD FACTORS HAVE NOT BEEN APPLIED. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

ELECTRICAL MEASUREMENTS INPUT VOLTAGE: 120.0 VOLTS AC INPUT CURRENT: 0.129 AMPS INPUT POWER: 15.2 WATTS POWER FACTOR: 98.2 PERCENT TOTAL HARMONIC DISTORTION: 11.49 PERCENT OFF STATE POWER: 0.00 WATTS LIGHT OUTPUT LUMENS: 461 lm EFFICACY: 30.4 lm/w SPECTRAL MEASUREMENTS X: 0.4352 y: 0.4124 u/u': 0.2459 v: 0.3496 v': 0.5244 Duv: 0.0035 CRI(R a ): 85.9 CRI(R 9 ): 46.8 CCT: 3095 K RADIANT FLUX: 1548 mw

SIDE VIEW LUMINOUS OPENING

All testing was conducted in accordance with LM-79-08, Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products as published by the Illuminating Engineering Society of North America (IESNA). The condition of the item tested was new. Stabilization time before testing exceeded 16 hours. The test results (luminous distribution and flux) were obtained by using a Lighting Sciences series 6000 Type C Moving Mirror Goniophotometer The photometric reference standard used is a set of three incandescent luminous intensity standard lamps calibrated and traceable to the U.S. National Institute of Standards and Technology. The test results (colorimetric and luminous flux) were obtained by using a Lighting Sciences model 4000 Integrating Sphere of either 1 or 2 meters diameter, having an internal reflectance exceeding 0.80. 4π geometry was used. Correction factors were applied for spectral mismatch and selfabsorption. The spectroradiometer employed was a LSC model 500E having a bandwidth of.84. The photometric reference standard used is a set of three incandescent luminous flux standard lamps calibrated and traceable to the U.S. National Institute of Standards and Technology. The colorimetric reference standard used is an incandescent spectral standard lamp calibrated and traceable to the U.S. National Institute of Standards and Technology. Power measurements were obtained with a Yokogawa WT210 power analyzer. Ambient temperature during testing was 25 C ± 1 C, measured using an Omega model DP460. Calibration certificates are on file at the laboratories of Lighting Sciences Inc.