UTILIZING ADVANCED MEASUREMENT DIAGNOSTICS TO IMPROVE POWERPLANT/POWERPLANT AVAILABILITY

Similar documents
CALCULATING AND OPTIMIZING ACCURACY & REPEATABILITY of NATURAL GAS CUSTODY TRANSFER FLOW MEASUREMENTS UNDER INSTALLED CONDITIONS

FOUNDATION Fieldbus: the Diagnostics Difference Fieldbus Foundation

Process Leak Detection Diagnostic with Intelligent Differential Pressure Transmitter

TAKING DIAGNOSTICS TO THE NEXT LEVEL ENDRESS+HAUSER

This article provides guidance to

Field Devices and Wiring

DOW IMPROVES INSTRUMENT RELIABILITY 66% AND SAVES MILLIONS OF DOLLARS WITH REAL-TIME HART TECHNOLOGY

Managing Complex Land Mobile Radio Systems

What does the Process Automation understand under Diagnosis?

Fieldbus Foundation India Committee. Fieldbus Foundation Asset Management and Diagnosis Automation-2010, India

LEVEL TECHNOLOGIES TO POWER THE FUTURE

MICO Solutions for Intelligent Power Distribution

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev TA April 2009.

INDUSTRIAL FIELD INSTRUMENT PROGRESSION TO SMART DIGITISATION ENABLING IIOT

Speed and Key Monitor Specifications

Getting the Best Performance from Challenging Control Loops

XYR 5000 Wireless Transmitters SIMPLE. SAFE. SECURE. Honeywell Solutions for Wireless Data Acquisiton and Monitoring

Energy harvesting wireless offers an easy, inexpensive alternative for adding energy management features to older automation systems.

Presented By: Michael Miller RE Mason

DeltaV SIS Logic Solver

1. Executive Summary. 2. Introduction. Selection of a DC Solar PV Arc Fault Detector

Refinery: Application: Hot Liquids Coker Feed Challenge Applications. Coker feed liquid is Hot Viscous Chunky Dangerous

Go New-Tech or Stick With DP Meters?

TS16 - Pre-Instructional Survey

Technologies, Solutions and Applications. Magnetic Level Indication and Bridle Measurements

Modulating control valve

Various Technics of Liquids and Solids Level Measurements (Part 4)

Shaft Absolute Vibration Monitor Specifications

ORBCOMM Machine-To-Machine (M2M)

BA507C & BA508C loop-powered 3½ digit panel mounting indicators

TI25 - Pre-Instructional Survey

Aqua-Gen 3BR INSTRUCTIONS

2012 Honeywell Users Group EMEA Tony Alexander Instrument Asset Management

Transmitters BROCHURE

Sustain.Ability. Kevin Boatright & John Yingst Field Device Manager: Instrument Nourishment through Smart Device Management

Why Design for Testability Sooner? 21 October 2008 Bruce Bardell, Technical Fellow Bradley Chief Architect BAE Systems

Huawei Connected City Lighting Solution

MONTRANO. Continuous monitoring system for power transformers

10. BSY-1 Trainer Case Study

Small transmitter, great potential use of beacons in potentially explosive atmospheres

SAPLING WIRELESS SYSTEM

SATs, Alternate SATs, wait, what?!

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Reliable power onboard and offshore

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features

ST 3000 Fieldbus Transmitter Series 100 Models

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

GSM BASED TRANSFORMER HEALTH MONITORING SYSTEM

To Calibrate or Not to Calibrate a fieldbus transmitter? Dale Perry Pressure Marketing Manager Rosemount

Fluke 570 Series Infrared Thermometers:

MGETM EPSTM /625/750/800 kva. Three phase UPS

DPharp OVERVIEW PRESSURE SENSORS INTRODUCTION FEATURES. Resonant silicon sensor

Top Design Considerations for Low-Power Metering Applications

Partial Discharge, Survey or Monitor?

Predictive Diagnostics for Pump Seals: Field Trial Learnings. Matthew Miller, John Crane

Design Implementation Description for the Digital Frequency Oscillator

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

For Medium Voltage Motors, Generators, Switchgear, Bus Duct and Cable Terminations

Partial Discharge Theory, Modeling and Applications To Electrical Machines

Foundation Fieldbus Control in the Field (CIF)

Instrumentation and Control

Artesis Predictive Maintenance Revolution

Smart Instruments Graduate Top of their Class with FDM Peter Overgaauw, Honeywell

XR kw AM Medium Wave Broadcast Transmitter

Mass Flow and Density Transmitter with FOUNDATION fieldbus

A Centralised Interlocking System for Low-density Line Signalling with a Predictive Monitoring System

Optimizing wind farms

Electrical Equipment Condition Assessment

BETWEEN SCAN TOOL & SUCCESSFUL DIAGNOSIS FILLING IN THE GAPS

Process Control Calibration Made Easy with Agilent U1401A

Non-Intrusive Ultrasonic Corrosion-Rate Measurements in Lieu of Manual and Intrusive Methods

Model 50 Ground Loop ph Sensor Model 55 Solution Ground ph Sensor

General Specifications

High Power DTV Monitoring ANDRE SKALINA WILLIAM A. DECORMIER Dielectric Communications Raymond, Maine GUY LEWIS Z Technology Beaverton, Oregon

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

CONTINUOUS CONDITION MONITORING WITH VIBRATION TRANSMITTERS AND PLANT PLCS

Architectural/Engineering Specification for a. Microwave Perimeter Intrusion Detection System

Improve asset protection and utilization

Increasing security. Saving space. Gaining flexibility. Signal Conditioners for Industrial Automation

SMARTLINE RM 70. Non-contact Radar (FMCW) Level Meter for liquids. Supplementary instructions

On-line Partial Discharge Assessment and Monitoring of MV to EHV Cables

InstrumentationTools.com

The wireless alternative to expensive cabling...

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

The Decision Aid Leak Notification System for Pigging False Alarm

Aqua-Gen 3PV INSTRUCTIONS

Optimizing throughput with Machine Vision Lighting. Whitepaper

XR kw AM Medium Wave Broadcast Transmitter

B850 Boiler House Energy Monitor

THE FIRST TO RESPOND. THE LAST TO GO HOME.

ADAM-4022T Serial Base Dual Loops PID Controller User s Manual

Making sense of electrical signals

Rosemount 3300 Series Guided Wave Radar Level & Interface Transmitter

The World Market for Pressure Transmitters, 3 rd Edition

Honeywell s Experion PKS and Field Device Manager Provide Award-winning HART Solution for Shell Upgrader

Mass and Volume Flow Transmitter

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

Logic Solver for Tank Overfill Protection

HART Compatible Intelligent 2-wire DIN Rail Transmitters

Agilent PNA Microwave Network Analyzers

Transcription:

Keywords UTILIZING ADVANCED MEASUREMENT DIAGNOSTICS TO IMPROVE POWERPLANT/POWERPLANT AVAILABILITY Scott Mawhinney, Business Development Manager Mark Menezes, Manager Pressure & PlantWeb (Americas) Rosemount Inc. Asset Management, Availability, Diagnostics, Digital Protocols, Predictive Maintenance Abstract Many past improvements in plant safety and availability have been accomplished by upgrading instrumentation, leading to improved measurement performance and/or device reliability. Unfortunately, many users are finding that while upgrading an older field device to state-of-theart can deliver significant improvements, the newest devices are so close to perfection that further upgrades will yield diminishing returns. The next round of improvements will be largely driven by the desire to increase overall plant availability. The advanced diagnostics present in today s smart transmitters, when combined with open digital protocols and Asset Management software, allow the user to remotely diagnose field devices and go beyond alarming transmitters failures to actually predict impending failures in the complete measurement system. This will significantly reduce unscheduled outages and improve overall plant availability. Traditional Approaches When Modernizing Field Devices When modernizing field devices, engineers have been driven by the desire to improve the measurement performance and/or device reliability and traditionally used a combination of three approaches: 1. Use more robust transmitters: Using robust transmitters that fail less frequently will directly improve the measurement performance and device reliability. For example, a plant with 400 transmitters each with an MTBF of 100 years can expect about 4 transmitter failures each year. Upgrading to higher quality transmitters with an MTBF of 400 years will reduce this to 1 failure each year. 2. Improve measurement accuracy and repeatability: Accurate and repeatable measurements minimize undetected failures and false trips. Consider the example of a control application such as fuel-air cross limiting were the user needs to maintain the ratio between fuel and air flowrates. Most users operate with an excess air safety buffer since the environmental and safety consequences of excess fuel greatly outweigh the purely economic consequences of excess air. Although many factors contribute to make a system non-ideal, it should be apparent that a system with a 5% flow measurement uncertainty will require a minimum 5% safety buffer. Improving the flow measurement from 5% to 1% improves consistency and provides the user with the opportunity, at no increased Page 1 of 1

environmental or safety risk, to improve process efficiency and reduce excess air and therefore reduce fuel cost. 3. Employ best practices in installation and maintenance: Many measurement failures can be attributed to poor installations or maintenance practices. For example, using very long impulse lines in a differential pressure flowmeter installation will increase the likelihood of impulse lines plugging and freezing. Using shorter impulse lines or converting to direct mount will improve both measurement performance and reliability and should actually cost less. Most users have continuously improved their measurements using the approaches outlined above. Unfortunately, many users are finding that while upgrading an older field device to stateof-the-art can deliver significant improvements, further upgrades will show little or no returns. In the example above, while the improvement from 5% to 1% flow measurement uncertainty may have significant benefits, it should be clear that future improvements, even to perfection, will return no more then one-third of the benefits of the previous upgrade. Similar comments apply to improvements in installation best practices and transmitter robustness. The Next Round of Improvements Increase Overall Plant Availability Diagnostics present in today s smart transmitters allow the user to remotely diagnose field devices and increase plant availability. These diagnostics are of limited usefulness unless the user can economically and conveniently access diagnostics alerts and information. Open Digital Protocols and Asset Management Software enable a user to access this information in an economic and convenient way. For an example, how useful is an Sensor failure detection if the user must climb a ladder to read that message on the transmitters local display? This diagnostic information is much more useful if it could be easily accessed at a PC online in the maintenance shop or at the local console of the control system. Open digital protocols such as HART or FOUNDATION Fieldbus allow a field device to transmit additional information on the same pair of wires that carry the process variable and allow access to diagnostic alerts and information online without any additional wiring. While proprietary digital protocols have existed for years, these continue to be abandoned by users and suppliers in favor of open protocols (Figure 1). Page 2 of 2

Figure 1 Global Pressure Transmitter Shipments (by protocol) (thousands) Once the diagnostics have been generated in the field device, and communicated via the digital protocol, the user needs some way of communicating that information in an organized fashion. Open standards means that users no longer require multiple maintenance terminals, and can consolidate all diagnostic information into a single asset management system, as shown in Figure 2. This not only minimizes capital, installation and training costs, but also simplifies maintenance and streamlines regulatory compliance. Figure 2 Asset Management System Page 3 of 3

Smart Transmitter Diagnostics Today s smart transmitters provide significant improvements in plant availability in areas of Device Diagnostics, Predictive Maintenance, and Onscale Failures. Device Diagnostics: Most all transmitter failures are repair by replacement. Reducing time to repair is really the time it takes to isolate the problem. Device diagnostics enables the user to quickly isolate the source of any problem. The screen capture below shows (Figure 3) shows a failed pressure transmitter electronics board ROM Checksum Error. Figure 3 Device Diagnostics This is an example of basic transmitter diagnostics what component in the transmitter has failed. Although the specific diagnostics ROM Checksum Error is usually of less interest then the recommended action, which is Replace Electronics, this detailed diagnostic message can trace failure to a specific component and assist the manufacture in preventing repeat failures ofthesametype. In addition to detecting failures, today s smart transmitters allow the user to easily diagnose application, configuration and installation errors. For example, the screen below (Figure 4) allows the user to see the current configuration of a pressure transmitter and easily determine the units configuration properties (range values, units, sensor limits) as well as additional information to determine if the transmitter is installed within the specified temperature limits. Page 4 of 4

Figure 4 Diagnosing Configuration Error The screen below (Figure 5) is an example of diagnosing application errors allowing the user to simulate a flow signal and test both the electronics and the configuration of the vortex meter. While older vortex meters allowed a fixed flow simulation to be done via board jumpers, today s smart devices allow user selected simulation to be done easily, either as shown from the Asset Management software or from a connected handheld configurator. Successful flow simulation in a vortex meter quickly determines any transmitter or configuration problems, and helps isolate an application error. Figure 5 Diagnosing Application Errors Page 5 of 5

Onscale Failures: Most transmitter failures are easy to detect the output of the transmitter either fails offscale high or offscale low. More difficult failures to detect are when the output of the transmitter is within normal range, and the measurement is failed onscale. Onscale failures tend to be associated not with the transmitter itself but with the rest of the measurement system. Many of these diagnostics overlap with those used to enable predictive maintenance. Predictive Maintenance: There are three different methods of maintenance that a plant can operate under: 1. Reactive: Fix it when it breaks 2. Preventive: Regularly scheduled maintenance to prevent failures 3. Predictive: Maximize uptime and fix it just before it breaks Most often plants operate with a combination of reactive and preventive maintenance. Consider an example of a boiler that has tripped do to a drop off of the primary airflow signal. The technician goes out to the unit and seeing a differential pressure of zero he/she changes out the transmitter. Fixing the transmitter when the problem occurred is reactive maintenance. The technician wants to prevent this from becoming a problem again and decides to add the transmitter to a six-month preventative maintenance schedule. Thinking that the problem was fixed the boiler is started up and after a short period of time trips again do to a zero primary airflow signal. Now looking at the situation closer the technician was able to find that the impulse lines from the transmitter to the orifice plate had become plugged. Seeing this, the lines were cleaned out and the unit was brought back on line. What is needed in this situation is predictive maintenance, which is the ability to diagnose that the lines are plugging and correct the situation before it fails and trips the boiler. This approach minimizes both maintenance labor and the risk of an unscheduled outage. Many users have used data from the DCS to predict measurement system failures. Although this approach is good to predict the overall health of the boiler a diagnostic located in the transmitter itself has a much better chance of detecting a problem with the measurement system before it causes a failure. For example, detecting and predicting plugged or frozen impulse lines. Figure 6 shows the undamped signals in the impulse lines measured by the differential pressure transmitter in a typical orifice meter installation. Page 6 of 6

Figure 6 Impulse Line Signals An open (unplugged) impulse line has high frequency noise due to fluid turbulence, comparable amplitude of noise for both the high and low side lines. If both lines are open, the physical offset between the high and low impulse lines creates a phase shift. As a result, the SUM has half the amplitude of either signal. If either line plugs, its signal will become flat with minimal cancellation, the SUM will have twice the amplitude of the OK SUM. If both lines are plugged, both will become flat, and as a result the SUM will be flat. To perform this diagnostic, the transmitter must calculate Variablility Index. The transmitter must learn the process and characterize an OK condition for a varying flowrate. Once the process is learned, and the diagnostic is online, an Index trending high will alert one line plugging, and an Index trending low will alert both lines plugging. A screen capture from Asset Management software is shown in Figure 7. Figure 7 Asset Management Screen Capture for Plugged Impulse Line Diagnostic Page 7 of 7

It should be clear that this diagnostic is only practical with a very fast pressure sensor. Since the diagnostic is performed in the transmitter itself, update rate to the DCS is not important, but a fast sensor, 50msec or less, is vital. Many pressure transmitters available today exceed this maximum response time by a factor of two to five times. Another example of predictive diagnostics in today s transmitters is detecting RTD drift with a redundant sensor. Located inside a dual input temperature transmitter connected to a dual element RTD, this diagnostic measures the difference between the two RTD s. If the RTD s have been sensor matched by the supplier, the difference should be less than 0.25 C. If the difference exceeds some user defined limit 1 C, the transmitter the alert is detected in the Asset Management software as shown below (Figure 8). Note that the transmitter can continue to operate with either RTD providing no interruption in the measurement. Figure 8 RTD Failure or Drift Diagnostic (Dual Element RTD) Conclusion Advanced diagnostics in today s smart field devices will significantly reduce unscheduled outages and improve overall plant availability. This paper has only presented diagnostics that exist today in field devices. The future of advanced diagnostic is bright and is being looked at as the Next Frontier in process control field devices. To ensure that the maximum benefit of advanced diagnostic capabilities in field devices is received users need to: Ensure that open protocols such as HART or FOUNDATION Fieldbus are being used. Gain experience with Asset Management software Ask their suppliers, what diagnostics are available now and what are planned for the future? Page 8 of 8