DETAIL 5 32 5 " 27 32 " 6" OPTIONAL FLAT RECESSED CLOSURE 1 1 4 " 17 32 " 1 25 32 " OPTIONAL BUTTERFLY CLOSURE CARRIER OVERHANG 1'-0" MAX CARRIER SPAN 4'-0" 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.2 TYPICAL SYSTEM SECTION SEE DETAIL THIS SHEET SEE DETAIL A1.1 SUSPENSION REQUIREMENTS SEE DETAIL A1.2 PANEL OVERHANG SPLICE SEE DETAIL A1.5 1'-0" MAX 1" WALL ANGLE SEE DETAIL A1.6 PANEL SPLICE SEE DETAIL A1.3 PANEL SPAN 4'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) FLOATING TRIM SEE DETAIL A1.7 TRIM NOT SHOWN FOR CLARITY SEE DETAILS A1.8 THROUGH A1.11 FOR FIXTURE OPENING RECOMMENDATIONS 6" MODULE PANEL ENDCAP SEE DETAIL A1.4 ENDCAP NOT SHOWN FOR CLARITY MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM OVERALL ISOMETRIC VIEW PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.0
" SYSTEM HEIGHT 17 32 " PANEL HEIGHT 17 32 " PANEL HEIGHT 5 32 5 " PANEL WIDTH PERFORATION #160: PERF. AREA 23% OPEN HOLE DIAMETER 0.060" 1 25 32 3'-0" MINIMUM PANEL LENGTH 16'-0" MAXIMUM RECOMMENDED PANEL LENGTH* LONGER LENGTH PANELS AVAILABLE, CONTACT HUNTER DOUGLAS FACTORY END & SIDE PANEL VIEW *PANEL LENGTHS AVAILABLE IN ± 1 8" TOLERANCE, MINIMUM QUANTITIES MAY APPLY MATERIAL THICKNESS PERFORATION DIRECTION BOX 6:.020",.025",.032",.040" ALUMINUM *VIEW FROM BELOW PANEL FINISHES PAINTED & POWDER COATED - INTERIOR & EXTERIOR - INTERIOR & EXTERIOR DECORATED WOOD FINISH (POWDER COATED) - INTERIOR & EXTERIOR WOOD VENEER - RECOMMENDED INTERIOR ONLY 10'-0" MAXIMUM RECOMMENDED PANEL LENGTH WITHOUT FINGER-JOINTING OF VENEER 5 32 5 " PANEL WIDTH PANEL MATERIALS & FINISHES 16'-0" MAXIMUM RECOMMENDED PANEL LENGTH WITH FINGER-JOINTING OF VENEER AVAILABLE PERFORATIONS SCALE: FULL (1:1) MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM PANEL SPEC PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.1
12" MAX CARRIER OVERHANG (CARRIER SPAN) 48" MAX HANGER WIRE SPACING 12 GA HANGER WIRE BY OTHERS, TYP. 48" MAX CARRIER SPACING (PANEL SPAN) 48" MAX CARRIER SPACING (PANEL SPAN) 12" MAX PANEL OVERHANG SIDE VIEW OF WITH PANEL END VIEW OF WITH PANEL * MATERIAL: FINISH: 0.040" ALUMINUM MATTE BLACK SUSPENSION PART LENGTH: 16'-0" *CARRIER SPLICE REQUIRED, SEE DETAIL A1.5 MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM CARRIER SPEC PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.2
SPLICE NOTE 1: DO NOT SPLICE PANELS DIRECTLY BELOW S. PANEL SPLICES DO NOT FIT UNDER CARRIERS. SPLICE NOTE 2: FIELD CUT PANELS AS REQUIRED TO CREATE A RANDOM STAGGERED SEAM PATTERN. AVOID ALIGNED SEAMS. BEYOND PANEL SEAM SPLICE, WILL NOT FIT UNDER SPLICE, WILL NOT FIT UNDER *HANGER WIRE OMITTED FOR CLARITY MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM PANEL SPLICE SPEC PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.3
INSERT END CAP ONTO PANEL AND ENSURE SHEAR TABS ARE ORIENTED ON TOP OF PANEL BOX 6 ENDCAP BOX 6 ENDCAP SCALE: FULL (1:1) *HANGER WIRE OMITTED FOR CLARITY MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM PANEL END CAP PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.4
SPLICE SPLICE IF THE DESIRED CARRIER LENGTH EXCEEDS THE MAXIMUM OF 16'-0", USE A LUXALON CARRIER SPLICE TO CONNECT THE FACTORY CARRIER ENDS. SNAP SPLICE TABS INTO THE TABS OF THE SPLICE SNAP INTO THE HOLES IN THE CARRIER AND ADDITIONAL FIXING IS NOT NECESSARY. THE MODULE IS CONTINUED AUTOMATICALLY. SCALE: FULL (1:1) *HANGER WIRE OMITTED FOR CLARITY of Hu nter Douglas. It MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM SPLICE PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.5
FIELD MITER TRIMS AT CORNERS FIELD CUT SIDE FOR WIDTH BEYOND FIELD CUT ENDS FOR LENGTH AS REQUIRED, TYPICAL 1" FIELD CUT SIDE 1" WALL ANGLE HOLD DOWN SCALE: 6" = 1'-0" 1" 1" WALL ANGLE TO SECURE FIELD CUT PANEL SIDE. 1" WALL ANGLE 0.025" ALUMINUM MATERIAL & FINISH TO MATCH, TYPICAL 12'-0" WALL ANGLE TRIM PART LENGTH 1" WALL ANGLE TRIM 1" *HANGER WIRE OMITTED FOR CLARITY MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM WALL ANGLE TRIM PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.6
2 1 4 " NOTCH TRIM AS REQUIRED FOR HANGER WIRE BEYOND 2 1 4 " 1 16 13 " 1 16 13 " FIELD CUT BOX 6 PANEL END SCALE: 6" = 1'-0" 1" FIELD CUT SIDE 1" WALL ANGLE HOLD DOWN SCALE: 6" = 1'-0" 1" DOUBLE-SIDED ADHESIVE TO SECURE 1" WALL ANGLE OR USE POP-RIVET 1-3/4" J-TRIM* 0.025" ALUMINUM MATERIAL & FINISH TO MATCH, TYPICAL *TRIM WRAPS PANEL & CARRIER 10'-0" 1-3/4" J-TRIM PART LENGTH *SOME HANGER WIRE OMITTED FOR CLARITY MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM FLOATING TRIM PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.7
INTERRUPT CARRIER AT FIXTURE LOCATION, TYPICAL 6-27/32" MAX CLEAR OPENING FOR SINGLE PANEL INTERRUPTION. 48" FIXTURE LENGTH EXAMPLE FULL 12-27/32" MAX CLEAR OPENING FOR DOUBLE PANEL INTERRUPTION. FIELD CUT TYPICAL ISOMETRIC 48" FIXTURE LENGTH EXAMPLE 51" MAX CARRIER SPACING AT FIXTURE ROW TOP VIEW 51" MAX CARRIER SPACING AT FIXTURE ROW 6-27/32" MAX CLEAR OPENING FOR SINGLE PANEL INTERRUPTION 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL 12" MAX, TYPICAL LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN LIGHT FIXTURE MANUFACTURER'S INSTRUCTIONS 6" X 48" RECESSED FLUORESCENT FIXTURE EXAMPLE WITH FLANGE 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN LIGHT FIXTURE MANUFACTURER'S INSTRUCTIONS BEYOND 6" X 48" RECESSED FLUORESCENT FIXTURE EXAMPLE WITH FLANGE BOX 4 PANEL RECESSED CLOSURE OPTIONAL 6 27 32 * FLANGED FIXTURE RECOMMENDED *6 27 32" MAX CLEAR OPENING, PANEL EDGE TO PANEL EDGE, FOR SINGLE PANEL INTERRUPTION. 12 27 32" MAX CLEAR OPENING, PANEL EDGE TO PANEL EDGE, FOR DOUBLE PANEL INTERRUPTION. UNIVERSAL CARRIER 51" MAX CARRIER SPACING AT LIGHT FIXTURE ROW NOTE: FIXTURE WITH TRIM FLANGE NOT BY HUNTER DOUGLAS of Hu nter Douglas. It MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM INTERRUPTED PANEL FOR TYPICAL FIXTURE PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.8
FULL FIELD CUT FIXTURE WIDTH VARIES FIXTURE WIDTH VARIES 12" MAX PANEL OVERHANG 12" MAX PANEL OVERHANG FIXTURE LENGTH VARIES FIXTURE LENGTH VARIES TYPICAL ISOMETRIC TOP VIEW UNIVERSAL CARRIER 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN LIGHT FIXTURE MANUFACTURER'S INSTRUCTIONS 6" X 48" RECESSED FLUORESCENT FIXTURE EXAMPLE WITH FLANGE FULL 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL 12" MAX, TYPICAL FLANGED FIXTURE RECOMMENDED LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN LIGHT FIXTURE MANUFACTURER'S INSTRUCTIONS 6" X 48" RECESSED FLUORESCENT FIXTURE EXAMPLE WITH FLANGE FULL BEYOND 48" MAX HANGER WIRE SPACING FLANGED FIXTURE RECOMMENDED FIELD CUT FIXTURE WIDTH VARIES NOTE: FIXTURE WITH TRIM FLANGE NOT BY HUNTER DOUGLAS MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM FIELD CUT PANEL FOR TYPICAL FIXTURE PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.9
INTERRUPT CARRIER AT LINEAR SLOT DIFFUSER LOCATION, TYPICAL 6-27/32" MAX CLEAR OPENING FOR 48" LINEAR SLOT DIFFUSER LENGTH EXAMPLE FULL SINGLE PANEL INTERRUPTION. FIELD CUT 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL TYPICAL ISOMETRIC 12" MAX, TYPICAL 48" LINEAR SLOT DIFFUSER LENGTH EXAMPLE 51" MAX CARRIER SPACING AT LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER INDEPENDENTLY SUPPORTED IN LINEAR SLOT DIFFUSER MANUFACTURER'S INSTRUCTIONS 12-27/32" MAX CLEAR OPENING FOR DOUBLE PANEL INTERRUPTION. TOP VIEW 51" MAX CARRIER SPACING AT LINEAR SLOT DIFFUSER 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL LINEAR SLOT DIFFUSER INDEPENDENTLY SUPPORTED IN LINEAR SLOT DIFFUSER MANUFACTURER'S INSTRUCTIONS 6-27/32" MAX CLEAR OPENING FOR SINGLE PANEL INTERRUPTION 12" MAX, TYPICAL BEYOND UNIVERSAL CARRIER FLANGED LINEAR SLOT DIFFUSER RECOMMENDED RECESSED CLOSURE OPTIONAL 6 27 32 * FLANGED LINEAR SLOT DIFFUSER RECOMMENDED *6 27 32" MAX CLEAR OPENING, PANEL EDGE TO PANEL EDGE, FOR SINGLE PANEL INTERRUPTION. 12 27 32" MAX CLEAR OPENING, PANEL EDGE TO PANEL EDGE, FOR DOUBLE PANEL INTERRUPTION. 51" MAX CARRIER SPACING AT LINEAR SLOT DIFFUSER NOTE: DIFFUSER WITH TRIM FLANGE NOT BY HUNTER DOUGLAS MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM INTERRUPTED PANEL FOR TYPICAL DIFFUSER PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.10
FULL FIELD CUT 12" MAX PANEL OVERHANG LINEAR SLOT DIFFUSER WIDTH VARIES LINEAR SLOT DIFFUSER LENGTH VARIES LINEAR SLOT DIFFUSER WIDTH VARIES 12" MAX PANEL OVERHANG LINEAR SLOT DIFFUSER LENGTH VARIES TYPICAL ISOMETRIC TOP VIEW UNIVERSAL CARRIER 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL LINEAR SLOT DIFFUSER INDEPENDENTLY SUPPORTED IN LINEAR SLOT DIFFUSER MANUFACTURER'S INSTRUCTIONS 12" MAX, TYPICAL 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL 12" MAX, TYPICAL LINEAR SLOT DIFFUSER INDEPENDENTLY SUPPORTED IN LINEAR SLOT DIFFUSER MANUFACTURER'S INSTRUCTIONS FULL BEYOND FLANGED LINEAR SLOT DIFFUSER RECOMMENDED 48" MAX HANGER WIRE SPACING FIELD CUT LINEAR SLOT DIFFUSER WIDTH VARIES FLANGED LINEAR SLOT DIFFUSER RECOMMENDED FULL NOTE: DIFFUSER WITH TRIM FLANGE NOT BY HUNTER DOUGLAS MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM FIELD CUT PANEL FOR TYPICAL DIFFUSER PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.11
SPLAYED 12 GA HANGER WIRE, BY OTHERS, TYP. 45 COMPRESSION STRUT E N 45 45 45 S W LATERAL BRACING: BRACE WITH HANGER WIRES AND STRUTS PER ASTM E-580 AND IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. (4) #12 GAUGE WIRES SPLAYED 90 FROM EACH OTHER AT ANGLE NOT EXCEEDING 45 FROM PLANE OF CEILING. A STRUT FASTENED TO MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO STRUCTURE ABOVE. SPLAYED WIRE AND STRUT BRACING TO BE PLACED NOT MORE THAN 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 6 FEET FROM EACH WALL. MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM SEISMIC SPEC PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.12