CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

Similar documents
INTERIOR INSTALLATION

INTERIOR INSTALLATION

METALWORKS TARTAN PANELS General Installation Instructions

METALWORKS Linear (Interior & Exterior Applications)

WOODWORKS Access Hook-on System

METALWORKS Linear (Interior & Exterior Applications)

METALWORKS Concealed. Installation Instructions

KS SERIES - VERTICAL INSTALLATION

Trim (Aluminum Substrate)

METALWORKS Linear (Interior & Exterior Applications)

AXIOM Classic Trim Installation Instructions

metalworks Plank Assembly and Installation Instructions 2.1 Read this entire document before proceeding with installation.

WOODWORKS Concealed. Assembly and Installation Instructions

AXIOM Classic Trim. Assembly and Installation Instructions

400 SERIES VERTICAL INSTALLATION

Classic Exposed Tee System (24" x 24", 24" x 48", and 24" x 72") Floating Clouds and Perimeter Wall Attachment

Linear Open Style Suspended Ceiling Installation Guide

WOODWORKS. Linear Solid Panels. Installation Instructions CEILING SYSTEMS. 1. General

Dura-Lock Roof System

AUXILIARY FRAMING AND ACCESSORIES

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

AXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL

INFUSIONS and METALWORKS Wings Accent and Acoustical Clouds

INSTALLATION INSTRUCTIONS FIXTURE SERIES: SAE 202 MOUNTING TYPE: RECESSED WALL / SLOT PAGE: 1 OF 8

Panel Grille Suspended Ceiling Installation Guide

DESIGNER SERIES GUTTER SYSTEM INSTALLATION INSTRUCTIONS

DW HORIZONTAL INSTALLATION

Double Beam Freestanding Pergola Installation Guide

WoodWORKS Channeled Plank

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

XL MAX. Suspension System Data Center Ceiling Solutions. Assembly and Installation Instructions


Construction details: Master-C type profiles and joints:

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET

Tools Required. Bench Hardware. Bench Parts. Planter Hardware. Planter Parts. BENCH/PLANTER INSTALLATION GUIDELINES for

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

Steel Sound Enclosure

900 SERIES WALL PANELS

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

REGAL. Installation Manual

DW VERTICAL INSTALLATION

WOODWORKS Grille System

(50 FT FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" 8-0" 6-0" Truss Depth. 3" sheets 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

metalworks Vector Assembly and Installation Instructions

LUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

Siding Components. Installation Guide

METALWORKS Wings Accent and Acoustical Clouds Installation Instructions

KS42 MF SERIES - HORIZONTAL INSTALLATION

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. International Version

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

MINIMALIST DOOR FRAMES PRODUCT BROCHURE ARCHITECTURAL METALS

T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY

APPENDIX A, UMC STANDARD 6-5 STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS

ATLANTIS RAIL Contact Information

Design and Construction Standards SECTION ATHLETIC LOCKERS

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

NX7 SERIES 5-1/2 HANDRAIL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION METAL LOCKERS

Low Headroom Rear Mount TorqueMaster

Hugger Installation. Roof Hugger, LLC P: P.O. Box 1027 F: Odessa, FL

Installation Instructions For TruLine 1.6A 24VDC

SURFACE CLIP MOUNT. 1 Insert lens into channel, measure, and cut to length. Remove lens cover from channel. surface. Attach lens cover and end caps

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

Installation Manual SOLID CORE SIDING

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

eco-shake INSTALLATION INSTRUCTION

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools...

STRUCTURAL REPAIR MANUAL FOR WIPLINE ALUMINUM FLOATS

Installation Instructions for Vista Air Vertically Folding Walls

POLYBAG KIT JOINER STRAP FIXTURE TYPE ROLL OF DOUBLE SIDED TAPE REQUIRED FOR R/POSITION WALL ANGLES (SEE STEP 6) 12"LG U-ANGLE (3) U-CLIPS

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

4 1/2" [114.3mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

3 11/16" [94.0mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY 6" [152.4mm]

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11

Installation Guidelines

LINESSE LINEAR LUMINAIRE 3 RECESSED CV2424

Indiana Limestone Company Honeycomb Panels

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

Parts List. Description. Installation Instructions

SAVE THESE INSTALLATION INSTRUCTIONS

SECTION BULLET- RESISTANT DOORS

JFI2089WTS Panel Dimension Guide 3/4 Overlay Panel Dimensions

T-GRID SYSTEM WIDE CLEANROOM CEILING GRID SYSTEM

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes

3" [76.0mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

calculated with factor of safety of 2.5 for bending stress, 3.0 for shear stresses and deflection limitation of L/180.

Installation Instructions

GENERAL ISOMETRIC LAYOUT

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

INSTALLATION TORSION SPRING FRONT OR REAR MOUNT LOW HEADROOM. 1 Cutting Vertical Track. 2 Fully Adjustable Jamb Brackets

Installation Guide 2016

ECOPHON Focus Ds 4x4 Installation Manual

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

Bionic 4 PERIMETER, CONTINUOUS RUN X3, X7

Transcription:

DETAIL 5 32 5 " 27 32 " 6" OPTIONAL FLAT RECESSED CLOSURE 1 1 4 " 17 32 " 1 25 32 " OPTIONAL BUTTERFLY CLOSURE CARRIER OVERHANG 1'-0" MAX CARRIER SPAN 4'-0" 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.2 TYPICAL SYSTEM SECTION SEE DETAIL THIS SHEET SEE DETAIL A1.1 SUSPENSION REQUIREMENTS SEE DETAIL A1.2 PANEL OVERHANG SPLICE SEE DETAIL A1.5 1'-0" MAX 1" WALL ANGLE SEE DETAIL A1.6 PANEL SPLICE SEE DETAIL A1.3 PANEL SPAN 4'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) FLOATING TRIM SEE DETAIL A1.7 TRIM NOT SHOWN FOR CLARITY SEE DETAILS A1.8 THROUGH A1.11 FOR FIXTURE OPENING RECOMMENDATIONS 6" MODULE PANEL ENDCAP SEE DETAIL A1.4 ENDCAP NOT SHOWN FOR CLARITY MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM OVERALL ISOMETRIC VIEW PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.0

" SYSTEM HEIGHT 17 32 " PANEL HEIGHT 17 32 " PANEL HEIGHT 5 32 5 " PANEL WIDTH PERFORATION #160: PERF. AREA 23% OPEN HOLE DIAMETER 0.060" 1 25 32 3'-0" MINIMUM PANEL LENGTH 16'-0" MAXIMUM RECOMMENDED PANEL LENGTH* LONGER LENGTH PANELS AVAILABLE, CONTACT HUNTER DOUGLAS FACTORY END & SIDE PANEL VIEW *PANEL LENGTHS AVAILABLE IN ± 1 8" TOLERANCE, MINIMUM QUANTITIES MAY APPLY MATERIAL THICKNESS PERFORATION DIRECTION BOX 6:.020",.025",.032",.040" ALUMINUM *VIEW FROM BELOW PANEL FINISHES PAINTED & POWDER COATED - INTERIOR & EXTERIOR - INTERIOR & EXTERIOR DECORATED WOOD FINISH (POWDER COATED) - INTERIOR & EXTERIOR WOOD VENEER - RECOMMENDED INTERIOR ONLY 10'-0" MAXIMUM RECOMMENDED PANEL LENGTH WITHOUT FINGER-JOINTING OF VENEER 5 32 5 " PANEL WIDTH PANEL MATERIALS & FINISHES 16'-0" MAXIMUM RECOMMENDED PANEL LENGTH WITH FINGER-JOINTING OF VENEER AVAILABLE PERFORATIONS SCALE: FULL (1:1) MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM PANEL SPEC PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.1

12" MAX CARRIER OVERHANG (CARRIER SPAN) 48" MAX HANGER WIRE SPACING 12 GA HANGER WIRE BY OTHERS, TYP. 48" MAX CARRIER SPACING (PANEL SPAN) 48" MAX CARRIER SPACING (PANEL SPAN) 12" MAX PANEL OVERHANG SIDE VIEW OF WITH PANEL END VIEW OF WITH PANEL * MATERIAL: FINISH: 0.040" ALUMINUM MATTE BLACK SUSPENSION PART LENGTH: 16'-0" *CARRIER SPLICE REQUIRED, SEE DETAIL A1.5 MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM CARRIER SPEC PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.2

SPLICE NOTE 1: DO NOT SPLICE PANELS DIRECTLY BELOW S. PANEL SPLICES DO NOT FIT UNDER CARRIERS. SPLICE NOTE 2: FIELD CUT PANELS AS REQUIRED TO CREATE A RANDOM STAGGERED SEAM PATTERN. AVOID ALIGNED SEAMS. BEYOND PANEL SEAM SPLICE, WILL NOT FIT UNDER SPLICE, WILL NOT FIT UNDER *HANGER WIRE OMITTED FOR CLARITY MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM PANEL SPLICE SPEC PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.3

INSERT END CAP ONTO PANEL AND ENSURE SHEAR TABS ARE ORIENTED ON TOP OF PANEL BOX 6 ENDCAP BOX 6 ENDCAP SCALE: FULL (1:1) *HANGER WIRE OMITTED FOR CLARITY MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM PANEL END CAP PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.4

SPLICE SPLICE IF THE DESIRED CARRIER LENGTH EXCEEDS THE MAXIMUM OF 16'-0", USE A LUXALON CARRIER SPLICE TO CONNECT THE FACTORY CARRIER ENDS. SNAP SPLICE TABS INTO THE TABS OF THE SPLICE SNAP INTO THE HOLES IN THE CARRIER AND ADDITIONAL FIXING IS NOT NECESSARY. THE MODULE IS CONTINUED AUTOMATICALLY. SCALE: FULL (1:1) *HANGER WIRE OMITTED FOR CLARITY of Hu nter Douglas. It MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM SPLICE PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.5

FIELD MITER TRIMS AT CORNERS FIELD CUT SIDE FOR WIDTH BEYOND FIELD CUT ENDS FOR LENGTH AS REQUIRED, TYPICAL 1" FIELD CUT SIDE 1" WALL ANGLE HOLD DOWN SCALE: 6" = 1'-0" 1" 1" WALL ANGLE TO SECURE FIELD CUT PANEL SIDE. 1" WALL ANGLE 0.025" ALUMINUM MATERIAL & FINISH TO MATCH, TYPICAL 12'-0" WALL ANGLE TRIM PART LENGTH 1" WALL ANGLE TRIM 1" *HANGER WIRE OMITTED FOR CLARITY MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM WALL ANGLE TRIM PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.6

2 1 4 " NOTCH TRIM AS REQUIRED FOR HANGER WIRE BEYOND 2 1 4 " 1 16 13 " 1 16 13 " FIELD CUT BOX 6 PANEL END SCALE: 6" = 1'-0" 1" FIELD CUT SIDE 1" WALL ANGLE HOLD DOWN SCALE: 6" = 1'-0" 1" DOUBLE-SIDED ADHESIVE TO SECURE 1" WALL ANGLE OR USE POP-RIVET 1-3/4" J-TRIM* 0.025" ALUMINUM MATERIAL & FINISH TO MATCH, TYPICAL *TRIM WRAPS PANEL & CARRIER 10'-0" 1-3/4" J-TRIM PART LENGTH *SOME HANGER WIRE OMITTED FOR CLARITY MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM FLOATING TRIM PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.7

INTERRUPT CARRIER AT FIXTURE LOCATION, TYPICAL 6-27/32" MAX CLEAR OPENING FOR SINGLE PANEL INTERRUPTION. 48" FIXTURE LENGTH EXAMPLE FULL 12-27/32" MAX CLEAR OPENING FOR DOUBLE PANEL INTERRUPTION. FIELD CUT TYPICAL ISOMETRIC 48" FIXTURE LENGTH EXAMPLE 51" MAX CARRIER SPACING AT FIXTURE ROW TOP VIEW 51" MAX CARRIER SPACING AT FIXTURE ROW 6-27/32" MAX CLEAR OPENING FOR SINGLE PANEL INTERRUPTION 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL 12" MAX, TYPICAL LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN LIGHT FIXTURE MANUFACTURER'S INSTRUCTIONS 6" X 48" RECESSED FLUORESCENT FIXTURE EXAMPLE WITH FLANGE 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN LIGHT FIXTURE MANUFACTURER'S INSTRUCTIONS BEYOND 6" X 48" RECESSED FLUORESCENT FIXTURE EXAMPLE WITH FLANGE BOX 4 PANEL RECESSED CLOSURE OPTIONAL 6 27 32 * FLANGED FIXTURE RECOMMENDED *6 27 32" MAX CLEAR OPENING, PANEL EDGE TO PANEL EDGE, FOR SINGLE PANEL INTERRUPTION. 12 27 32" MAX CLEAR OPENING, PANEL EDGE TO PANEL EDGE, FOR DOUBLE PANEL INTERRUPTION. UNIVERSAL CARRIER 51" MAX CARRIER SPACING AT LIGHT FIXTURE ROW NOTE: FIXTURE WITH TRIM FLANGE NOT BY HUNTER DOUGLAS of Hu nter Douglas. It MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM INTERRUPTED PANEL FOR TYPICAL FIXTURE PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.8

FULL FIELD CUT FIXTURE WIDTH VARIES FIXTURE WIDTH VARIES 12" MAX PANEL OVERHANG 12" MAX PANEL OVERHANG FIXTURE LENGTH VARIES FIXTURE LENGTH VARIES TYPICAL ISOMETRIC TOP VIEW UNIVERSAL CARRIER 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN LIGHT FIXTURE MANUFACTURER'S INSTRUCTIONS 6" X 48" RECESSED FLUORESCENT FIXTURE EXAMPLE WITH FLANGE FULL 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL 12" MAX, TYPICAL FLANGED FIXTURE RECOMMENDED LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN LIGHT FIXTURE MANUFACTURER'S INSTRUCTIONS 6" X 48" RECESSED FLUORESCENT FIXTURE EXAMPLE WITH FLANGE FULL BEYOND 48" MAX HANGER WIRE SPACING FLANGED FIXTURE RECOMMENDED FIELD CUT FIXTURE WIDTH VARIES NOTE: FIXTURE WITH TRIM FLANGE NOT BY HUNTER DOUGLAS MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM FIELD CUT PANEL FOR TYPICAL FIXTURE PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.9

INTERRUPT CARRIER AT LINEAR SLOT DIFFUSER LOCATION, TYPICAL 6-27/32" MAX CLEAR OPENING FOR 48" LINEAR SLOT DIFFUSER LENGTH EXAMPLE FULL SINGLE PANEL INTERRUPTION. FIELD CUT 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL TYPICAL ISOMETRIC 12" MAX, TYPICAL 48" LINEAR SLOT DIFFUSER LENGTH EXAMPLE 51" MAX CARRIER SPACING AT LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER INDEPENDENTLY SUPPORTED IN LINEAR SLOT DIFFUSER MANUFACTURER'S INSTRUCTIONS 12-27/32" MAX CLEAR OPENING FOR DOUBLE PANEL INTERRUPTION. TOP VIEW 51" MAX CARRIER SPACING AT LINEAR SLOT DIFFUSER 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL LINEAR SLOT DIFFUSER INDEPENDENTLY SUPPORTED IN LINEAR SLOT DIFFUSER MANUFACTURER'S INSTRUCTIONS 6-27/32" MAX CLEAR OPENING FOR SINGLE PANEL INTERRUPTION 12" MAX, TYPICAL BEYOND UNIVERSAL CARRIER FLANGED LINEAR SLOT DIFFUSER RECOMMENDED RECESSED CLOSURE OPTIONAL 6 27 32 * FLANGED LINEAR SLOT DIFFUSER RECOMMENDED *6 27 32" MAX CLEAR OPENING, PANEL EDGE TO PANEL EDGE, FOR SINGLE PANEL INTERRUPTION. 12 27 32" MAX CLEAR OPENING, PANEL EDGE TO PANEL EDGE, FOR DOUBLE PANEL INTERRUPTION. 51" MAX CARRIER SPACING AT LINEAR SLOT DIFFUSER NOTE: DIFFUSER WITH TRIM FLANGE NOT BY HUNTER DOUGLAS MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM INTERRUPTED PANEL FOR TYPICAL DIFFUSER PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.10

FULL FIELD CUT 12" MAX PANEL OVERHANG LINEAR SLOT DIFFUSER WIDTH VARIES LINEAR SLOT DIFFUSER LENGTH VARIES LINEAR SLOT DIFFUSER WIDTH VARIES 12" MAX PANEL OVERHANG LINEAR SLOT DIFFUSER LENGTH VARIES TYPICAL ISOMETRIC TOP VIEW UNIVERSAL CARRIER 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL LINEAR SLOT DIFFUSER INDEPENDENTLY SUPPORTED IN LINEAR SLOT DIFFUSER MANUFACTURER'S INSTRUCTIONS 12" MAX, TYPICAL 12 GA HANGER WIRE, 48" O.C. MAX, BY OTHERS, TYPICAL 12" MAX, TYPICAL LINEAR SLOT DIFFUSER INDEPENDENTLY SUPPORTED IN LINEAR SLOT DIFFUSER MANUFACTURER'S INSTRUCTIONS FULL BEYOND FLANGED LINEAR SLOT DIFFUSER RECOMMENDED 48" MAX HANGER WIRE SPACING FIELD CUT LINEAR SLOT DIFFUSER WIDTH VARIES FLANGED LINEAR SLOT DIFFUSER RECOMMENDED FULL NOTE: DIFFUSER WITH TRIM FLANGE NOT BY HUNTER DOUGLAS MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM FIELD CUT PANEL FOR TYPICAL DIFFUSER PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.11

SPLAYED 12 GA HANGER WIRE, BY OTHERS, TYP. 45 COMPRESSION STRUT E N 45 45 45 S W LATERAL BRACING: BRACE WITH HANGER WIRES AND STRUTS PER ASTM E-580 AND IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. (4) #12 GAUGE WIRES SPLAYED 90 FROM EACH OTHER AT ANGLE NOT EXCEEDING 45 FROM PLANE OF CEILING. A STRUT FASTENED TO MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO STRUCTURE ABOVE. SPLAYED WIRE AND STRUT BRACING TO BE PLACED NOT MORE THAN 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 6 FEET FROM EACH WALL. MATERIAL:.020".025".032".040" ALUMINUM.040" ALUMINUM SEISMIC SPEC PROJECT: LINEAR BOX 6 PRODUCT DRAWING NUMBER: BOX6-A1.12