Baseline Proposal for 400G/80km. Ilya Lyubomirsky, Jamal Riani, Ben Smith, Sudeep Bhoja, Inphi Corp. Rich Baca, Microsoft Corp.

Further considerations on objectives for PHYs running over point-to-point DWDM systems

Low Power DSP and Photonic Integration in Optical Networks. Atul Srivastava CTO, NTT Electronics - America. Market Focus ECOC 2014

White Paper. 100G beyond 10km A global study coherent and PAM4 Technology. Date: By Ambroise Thirion

100G Coherent Transceiver Technologies for DWDM Metro Applications: Key Requirements and Design Trends

WDM in backbone. Péter Barta Alcatel-Lucent

ECOC Market Focus Linear Components Enabling Flexible Optical Networks. Sep 24, 2014 Lian Zhao Richard Ward

THE ROLE OF HIGHER BAUD RATES IN EVOLVING COHERENT TRANSPORT

Optical Networks emerging technologies and architectures

Good Things Come in Small Cubes. Cube Optics 100G Metro Evolution TREX14 01/06/14

Baseline proposal for a 400 Gb/s optical PMD supporting four MMF pairs

Global Consumer Internet Traffic

11.1 Gbit/s Pluggable Small Form Factor DWDM Optical Transceiver Module

Emerging Highly Compact Amplification Solutions for Coherent Transmission

CWDM Cisco CWDM wavelengths (nm)

Polarization Optimized PMD Source Applications

Extending 100Gbit/s Ethernet. Ariën Vijn

40Gb/s & 100Gb/s Transport in the WAN Dr. Olga Vassilieva Fujitsu Laboratories of America, Inc. Richardson, Texas

Si Photonics Technology Platform for High Speed Optical Interconnect. Peter De Dobbelaere 9/17/2012

Optical Integration and DSP in Next Generation Networks. Atul Srivastava CTO, NTT Electronics - America. Market Focus ECOC 2013

Filling the fiber: Factors involved in absolute fiber capacity Geoff Bennett, Infinera UKNOF September 2007

Optical Measurements in 100 and 400 Gb/s Networks: Will Coherent Receivers Take Over? Fred Heismann

400G-FR4 Technical Specification

Cisco PONC Pavan Voruganti Senior Product Manager. March 2015

40 Gb/s and 100 Gb/s Ultra Long Haul Submarine Systems

400G-BD4.2 Multimode Fiber 8x50Gbps Technical Specifications

Scott Schube, Intel Corporation CWDM8 MSA Project Chair

Optical Transport Tutorial

Real-time transmission of 16 Tb/s over 1020km using 200Gb/s CFP2-DCO

Silicon Photonics Transceivers for Hyper Scale Datacenters: Deployment and Roadmap

VePAL UX400 Universal Test Platform

40Gb/s Coherent DP-PSK for Submarine Applications

SMF PMD Modulation Observations. 400 Gb/s Ethernet Task Force SMF Ad Hoc Conference Call 24 February 2015 Chris Cole

Proposal for 4-channel WDM (WDM4) for intermediate reach 100GbE SMF PMD

L évolution des systèmes de transmission optique très haut débit et l impact de la photonique sur silicium

Feasibility study of 100G/lambda Nyquist-PAM4 with commercially available 1.3um/1.5um EML

Spectral-Efficient 100G Parallel PHY in Metro/regional Networks

Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform

Optical Transport Technologies and Trends

Good Things Come in Small Cubes. Cube Optics Multiple 100G DWDM Testing March 2014

FPGA based Prototyping of Next Generation Forward Error Correction

PAM-4 Four Wavelength 400Gb/s solution on Duplex SMF

WDM. Coarse WDM. Nortel's WDM System

25G TDM PON overview. Ed Harstead, member Fixed Networks CTO Dora van Veen, Vincent Houtsma, and Peter Vetter, Bell Labs

Comment Supporting materials: The Reuse of 10GbE SRS Test for SR4/10, 40G-LR4. Frank Chang Vitesse

Annex 91A Coexistence of 1 Gb/s (symmetric), 10 Gb/s (symmetric) and 10/1 Gb/s (asymmetric) Ethernet Passive Optical Networks (EPONs)

System Impairments Mitigation for NGPON2 via OFDM

400G CWDM8 10 km Optical Interface Technical Specifications Revision 1.0

Qualifying Fiber for 10G Deployment

10GBASE-S Technical Feasibility

UNIVERSITY OF TORONTO FACULTY OF APPLIED SCIENCE AND ENGINEERING. FINAL EXAMINATION, April 2017 DURATION: 2.5 hours

Updated in 2017 Free Product Guide for Your Network. Transceiver. Catalog

UNREPEATERED SYSTEMS: STATE OF THE ART

Single- versus Dual-Carrier Transmission for Installed Submarine Cable Upgrades

Ross Saunders GM, Next-gen Transport Opnext Subsystems Inc. 100G Cost/Performance Optimization

The Challenges of Data Transmission toward Tbps Line rate in DWDM System for Long haul Transmission

Next-Generation Optical Fiber Network Communication

Thursday, April 17, 2008, 6:28:40

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 16 Channels C27-C42 Dual Fiber DWDM Mux Demux 1U Rack Mount, LC/UPC

EDFA Applications in Test & Measurement

From static WDM transport to software-defined optics

Photonic Integrated Circuits for 400 Gigabit and 1 Terabit Coherent Transport

PHY High Level Block Diagrams and First Pass Look at PHY Delays. Avi Kliger, Mark Laubach Broadcom

DATASHEET G Data Center Interconnect (DCI) 100G Embedded DWDM (DWDM transciever in to Ethernet switch with no OEO transponder requirement)

Eye-Diagram-Based Evaluation of RZ and NRZ Modulation Methods in a 10-Gb/s Single-Channel and a 160-Gb/s WDM Optical Networks

Technical Feasibility of 4x25 Gb/s PMD for 40km at 1310nm using SOAs

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

Multilane MM Optics: Considerations for 802.3ba. John Petrilla Avago Technologies March 2008

Single channel and WDM transmission of 28 Gbaud zero-guard-interval CO-OFDM

WDM Alternatives for 100Gb SMF Applications

100G CWDM4 MSA Technical Specifications 2km Optical Specifications

Coherent Receivers: A New Paradigm For Optical Components. ECOC Market Focus September 20, 2010

CFORTH-QSFP28-100G-LR4 Specifications Rev. D00B. Product Features

Improved Results for both 56 and 112Gb/s PAM4 Signals

Specification for 100GBASE-DR4. Piers Dawe

SERDES for 100Gbps. May 24, 2017 Bart Zeydel, Francesco Caggioni, Tom Palkert

from ocean to cloud WELCOME TO 400GB/S & 1TB/S ERA FOR HIGH SPECTRAL EFFICIENCY UNDERSEA SYSTEMS

10GBASE-T Transmitter Key Specifications

Digital Return System

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Coexistence of 1 Gb/s (symmetric), 10 Gb/s (symmetric) and 10/1 Gb/s (asymmetric) Ethernet Passive Optical Networks (EPONs)

Proposal for 400GE Optical PMDs for SMF Objectives based on 4 x 100G DMT David Lewis, Sacha Corbeil, Beck Mason

Ultrahigh-capacity Digital Coherent Optical Transmission Technology

OPTICAL TECHNOLOGY TRAINING

ITU-T G (11/2009) Multichannel DWDM applications with single-channel optical interfaces

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Mike Harrop September PMD Testing in modern networks

Optical DWDM Networks

from ocean to cloud THE FUTURE IS NOW - MAXIMIZING SPECTRAL EFFICIENCY AND CAPACITY USING MODERN COHERENT TRANSPONDER TECHNIQUES

X5 and Z5 Modulator. Telcordia 468. Key Features. Applications. Compliance AGILE OPTICAL COMPONENTS NORTH AMERICA: JDSU (5378)

SUBMARINE SYSTEM UPGRADES WITH 25 GHZ CHANNEL SPACING USING DRZ AND RZ-DPSK MODULATION FORMATS

Performance Analysis Of Hybrid Optical OFDM System With High Order Dispersion Compensation

Phase Modulator for Higher Order Dispersion Compensation in Optical OFDM System

RXT-1200 Modular Test Platform

Long-Haul DWDM RF Fiber Optic Link System

All-Optical Signal Processing. Technologies for Network. Applications. Prof. Paul Prucnal. Department of Electrical Engineering PRINCETON UNIVERSITY

XWDM Solution for 64 Terabit Optical Networking

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Global Cloud Network Evolution

Multichannel DWDM applications with single channel optical interfaces for repeaterless optical fibre submarine cable systems

Transcription:

Towards an objective for 400 Gb/s for DCI applications Markus Weber, Tom Williams - Acacia Gary Nicholl, Mark Nowell - Cisco Tad Hofmeister - Google Ilya Lyubomirsky - Inphi Jeffrey Maki - Juniper Rich Baca, Brad Booth, Mark Filer - Microsoft

Supporters Your name here 2

Topics Background Market Need Technical Feasibility and Leverage 400G Extender Sublayer PCS FEC Optics Economic Feasibility Summary Proposed Objective Backup 3

Background There is interest within the industry in defining new Ethernet DWDM PHYs with the ability to run over a single-channel (wavelength) port on a DWDM multichannel optical system. At the Chicago meeting (March, 2018) an objective was adopted to support 100 Gb/s operation on a single wavelength capable of at least 80km over a DWDM system, and initially targeting the Cable/MSO market. This presentation proposes to adopt a similar objective to support 400 Gb/s operation on a single wavelength capable of at least 80km over a DWDM system, and initially targeting the DCI market. 4

Market Need 5

Global Data Center Traffic Growth Data Center Traffic Triples from 2016 to 2021 6

Global Data Center Traffic by Destination, 2021 Target of this presentation Addressed by 802.3bs a Source: Cisco Global Cloud Index, 2016 2021 7

100 Gb/s and 400 Gb/s Coherent Market 100 Gb/s and 400 Gb/s market data coming soon (waiting on approval) Key Points: 400 Gb/s market starts in 2019 Coherent edge (100G and 400G) represents > 25% of whole coherent market in 2022 Edge applications expected to be dominated by Ethernet 8

Use Case Example 400Gb/s DCI Azure WAN Backbone Region long haul DCI 100 km 9

Technical Feasibility 10

400Gb/s DCI Application Overview 400Gb/s Ethernet Reach of at least 80km over a DWDM system (black-link) Single wavelength 16 Tb/s per fiber Standard 400GAUI electrical interface Compatible with 400G Ethernet switch/router ports (i.e. QSFP-DD/OSFP pluggable form factor) Multi-vendor interop is critical Switch / Router A 400ZR DWDM Mux Amplifier black-link DWDM Mux Amplifier 400ZR Switch / Router B 11

400GbE Extender Sublayer Recap MAC/RS 400GBASE-R PCS PMA 400GMII MAC/RS DTE 400GXS PMA 400GXS 400GXS (Extender Sublayer) extends the 400GMII over a physically instantiated 400GAUI-n PMA PMD Medium 400GAUI-n MDI 400GBASE-R PHY (IEEE P802.3bs) PMA PHY 400GXS 400GMII New 400G PCS New PMA New PMD MDI 400GXS is defined in IEEE P802.3bs Clause 118 The 400GXS allows a new 400G PHY (with different line coding/fec) to interface to an existing 400G switch port/asic over the 400GAUI 400G Coherent DWDM PHY is an example of a new 400G PHY that requires different coding/fec Medium New 400G PHY, e.g. 400G Coherent 12

400G Coherent PCS Overview 400G Coherent PCS 400GAUI-8 400G PHY XS 400GMII 64B/66B 256B/257B Transcode GMP v Scrambler v Async v HD vfec SD vfec v Mapper Staircase (255,239) Hamming (128,119) Pilot Tone / TS Insert Existing Clause 118 Existing Clause 119 New (leverage from OIF) Reuse significant amount of 802.3bs PCS (Clause 119) Leverage FEC from OIF 400ZR project Async mapping is something new decouples 400GAUI-8 from the 400G Coherent PMD (different clock domains) ADC & DAC can use same clock reference clock (cost savings in optical module) 13

400G Coherent FEC Strong industry consensus already exists for a multi-vendor FEC for 400G coherent applications, and it is currently under development in the OIF as part of the 400ZR project. 400G Concatenated FEC: Soft decision inner Hamming (128,119) Code Hard decision outer Staircase Code (255,239) NCG = 10.8dB for 16QAM FEC overhead = 14.8 % Ultra Low Power = 420 mw (7nm, 400G) Burst Tolerance = 1024 bits, including random errors from background noise (more than 2048 bits without background noise) Latency = 4 ms Source Inphi 14

400G DWDM Coherent Optics To be added 15

Economic Feasibility Traditionally long haul transmission technology has been higher power, higher cost and physically larger, than corresponding client interface technology With the combination of reduced reach targets (80km) and advanced CMOS technology nodes (7nm), both coherent and client technologies can be implemented in the same form factors Economically this significantly lowers network cost and increases flexibility 16

Comparing 400G Coherent with 400G Client 400G FR4: PAM4 on 4 wavelengths 4 x Laser 400G Coherent: PAM4 on XI, XQ, YI, YQ 1 x Laser DSP 4 x MZI/EML DSP 4 x Driver WDM 1 x 400GAUI 1 x 400GAUI Combine 4 x ADC 4 x ADC 4 x RX / splitter 4 x DAC 4 x TIA 4 x DAC 4 x MZI 4 x Driver 4 x RX 4 x TIA Pol & IQ Combine / splitter Client DSP Coherent DSP Source Acacia Similar size die (pad limited) > 50% of power consumption is in ADC/DAC and SERDES Both coherent and client feasible in same form factor 17

Impact of advanced integration Advances in CMOS and optical integration have driven reductions in size, cost and power for coherent solutions Source Acacia 18

Summary Market need for 400 Gb/s Ethernet DWDM solutions up to 80km has been identified Coherent technology for 400 Gb/s long-haul and metro applications exists and is being deployed, suggesting IEEE 802.3 specifications for 80km links are feasible Current industry activities and consensus will enable interoperable specifications be developed (Hopefully) clear use case identified for proposed SG objective 19

Proposed Objective Propose the SG adopts an objective: Provide physical layer specifications supporting 400 Gb/s operation on a single wavelength capable of at least 80km over a DWDM system. 20

Companion objectives Associated with the proposed PHY objective, the SG would also need the related objectives to be adopted: Support a MAC data rate of 400 Gb/s Support a BER of better than or equal to 10^-13 at the MAC/PLS service interface (or the frame loss ratio equivalent) for 400 Gb/s Assumption is these would be all included together in same motion 21

Backup 22

DWDM terminology recap 23

Updated terminology (from 2/27/18 ad hoc) WDM optical technology that couples more than one wavelength in the same fiber, thus effectively increasing the aggregate bandwidth per fiber to the sum of the bit rates of each wavelength. DWDM A WDM technology where the frequency spacing is less than or equal to 1000 GHz. DWDM PHY: An Ethernet PHY that operates at a single wavelength on a defined frequency grid and is capable of running over a DWDM system. DWDM Channel: The transmission path between a DWDM PHY transmitting to another DWDM PHY. DWDM Link: One DWDM PHY transmitting to one other DWDM PHY through the transmission path between them. DWDM System: An aggregate of DWDM links over either a single optical fiber or a single optical fiber per direction. DWDM Network - same as DWDM System so term not to be used In-line amplification: Optical amplification that resides within a DWDM Channel Modified/New from ad hoc Proposed Delete 24

Link Types Presented by Pete Anslow. Excellent summary of link type configurations. Type 1, 2, 3 all represent what would be typical of past IEEE 802.3 PMDs * * Common usage would call these Optical PHYs as opposed to Electrical PHYs and different to the DWDM PHY which could be the outcome of the proposed objective in this presentation. http://www.ieee802.org/3/b10k/public/18_01/anslow_b10k_01_0118.pdf * Proposed modification to slides 25

Link Types Link Types 4 & 5 are representative of network topologies consistent with DWDM Systems and technologies. The range of Cable/MSO deployments are consistent with both Type 4 & 5 link types http://www.ieee802.org/3/b10k/public/18_01/anslow_b10k_01_0118.pdf 26

DWDM Link Types and Terminology DWDM PHY: DWDM Channel: DWDM Link: DWDM System: http://www.ieee802.org/3/b10k/public/18_01/anslow_b10k_01_0118.pdf 27

Coherent optical DWDM technology overview 28

Coherent DWDM Overview Coherent optical technology was significantly studied and researched from the mid-80 s due to it s potential to overcome optical fiber transmission challenges that exist with the direct-detection approaches. Invention of Erbium optical amplifier, stalled progress for a while Above 10 Gb/s, direct detection transmission was becoming a challenging solution to achieve Mid-2000 s, intersection of CMOS and optical technology capabilities opened possibility that a coherent-detection solution was feasible for 40 Gb/s March 2008, Nortel (Ciena) announce first commercial transmission system @ 40 Gb/s Today, coherent-based transport is now the de-facto standard technology choice for transmission solutions @ 40 Gb/s, 100 Gb/s, 250 Gb/s, 400 Gb/s and beyond Widespread & mature technology Originally targeted for Long-haul and Ultra-long haul solutions, recent market focus includes metro and lower reach optimizations 29

Key points: Coherent vs. direct detection Coherent transceivers use linear E/O & O/E conversion Use of local oscillator at receiver ensures full optical field (amplitude and phase) survives after the photodetector Enables more complex modulation schemes to be employed to increase capacity Linear optical distortions remain linear. Digital Signal Processing may then be used to compensate the channel / transceiver Complexity / constraints of DSP depends upon application Wide range of optical impairments can be compensated in the DSP Simplifies operational issues Complexity shared between optical and digital technologies 30

What is Coherent Detection? By mixing with a local oscillator, the received optical signal is down-converted to baseband and sampled with a high speed ADC Coherent detection requires the addition of a local oscillator (usually shared with transmit laser) and additional DSP processing. Effectively amplifies the incoming signal Total field information (amplitude, phase, polarization) is maintained into the electrical/digital domain enabling equalization of link impairments by a digital signal processor (DSP) 31

How Does Coherent Increase Capacity? Modulation in Phase and Amplitude Polarization Multiplexing C a p a c i t y 2x capacity of intensity modulation P e r f o r m a n c e 2x capacity of single polarization 32

Coherent DWDM Applications Proven Applications Aspect Cable/MSO/ Data Center Metro Regional Long-Haul Submarine Reach (km) 80 300 600 4000 10000 Chromatic Dispersion (ps/nm) 1280 5000 15000 80000 240000 DGD max (ps) 16 30 43 111 35 Latency (Critical?) Yes Sometimes Less so Not so Not really OSNR/FEC Low Perf. Hi-perf Hi-perf Hi-perf Hi-perf Cost Low Low Mid Mid High Power Ultra low Low Mid Mid Mid 33