Further development of synthetic aperture real-time 3D scanning with a rotating phased array

Similar documents
Parametric Beamformer for Synthetic Aperture Ultrasound Imaging

3D synthetic aperture imaging using a virtual source element in the elevation plane

Designing Non-linear Frequency Modulated Signals For Medical Ultrasound Imaging

A Delta-Sigma beamformer with integrated apodization

Simulation of advanced ultrasound systems using Field II

3-D Imaging using Row--Column-Addressed 2-D Arrays with a Diverging Lens

COMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES

Linear arrays used in ultrasonic evaluation

3-D Imaging using Row Column-Addressed 2-D Arrays with a Diverging Lens: Phantom Study

System Architecture of an Experimental Synthetic Aperture Real-time Ultrasound System

Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI

A Waveguide Transverse Broad Wall Slot Radiating Between Baffles

Log-periodic dipole antenna with low cross-polarization

Virtual ultrasound sources

Encoding of inductively measured k-space trajectories in MR raw data

Scanning laser Doppler vibrometry

Cross-polarization and sidelobe suppression in dual linear polarization antenna arrays

300 GHz Imaging System with 8 Meter Stand-off Distance and One-Dimensional Synthetic Image Reconstruction for Remote Detection of Material Defects

Ultrasound Research Scanner for Real-time Synthetic Aperture Data Acquisition

Three-Dimensional Synthetic Aperture Focusing Using a Rocking Convex Array Transducer

Multi-Element Synthetic Transmit Aperture Method in Medical Ultrasound Imaging Ihor Trots, Yuriy Tasinkevych, Andrzej Nowicki and Marcin Lewandowski

Evaluation of automatic time gain compensated in-vivo ultrasound sequences

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl

Accurate Antenna Models in Ground Penetrating Radar Diffraction Tomography

Real Time Deconvolution of In-Vivo Ultrasound Images

Broadband Minimum Variance Beamforming for Ultrasound Imaging

Ultrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming

CHAPTER 1 INTRODUCTION

Novel Electrically Small Spherical Electric Dipole Antenna

FPGA-BASED CONTROL SYSTEM OF AN ULTRASONIC PHASED ARRAY

FPGA-Based Control System of an Ultrasonic Phased Array Keywords: ultrasonic imaging, phased array, B-scan, FPGA

Spatial Encoding Using a Code Division Technique for Fast Ultrasound Imaging

Self-Resonant Electrically Small Loop Antennas for Hearing-Aids Application

Acoustical cross-talk in row column addressed 2-D transducer arrays for ultrasound imaging

Separation of common and differential mode conducted emission: Power combiner/splitters

Transmitting Performance Evaluation of ASICs for CMUT-Based Portable Ultrasound Scanners

Microwave Radiometer Linearity Measured by Simple Means

Evaluation of the Danish Safety by Design in Construction Framework (SDCF)

Synthetic Aperture Beamformation using the GPU

A hand-held row-column addressed CMUT probe with integrated electronics for volumetric imaging

HIGH RESOLUTION MULTI-BEAM SIDE LOOKING SONAR ANDRZEJ ELMINOWICZ, LEONARD ZAJĄCZKOWSKI

Medical ultrasound has gained popularity in the clinical

Reconfigurable Arrays for Portable Ultrasound

Decreasing the commutation failure frequency in HVDC transmission systems

An Overview Algorithm to Minimise Side Lobes for 2D Circular Phased Array

VBS - The Optical Rendezvous and Docking Sensor for PRISMA

Spectral Velocity Estimation using the Autocorrelation Function and Sparse Data Sequences

Integrated Reconfigurable High-Voltage Transmitting Circuit for CMUTs

DIGITAL BEAM-FORMING ANTENNA OPTIMIZATION FOR REFLECTOR BASED SPACE DEBRIS RADAR SYSTEM

A Multifrequency Radiometer System

Design and Measurement of a 2.45 Ghz On-Body Antenna Optimized for Hearing Instrument Applications

The current distribution on the feeding probe in an air filled rectangular microstrip antenna

Detection of mechanical instability in DI-fluxgate sensors

Low-Profile Fabry-Pérot Cavity Antenna with Metamaterial SRR Cells for Fifth Generation Systems

Sonic Distance Sensors

ECHO-CANCELLATION IN A SINGLE-TRANSDUCER ULTRASONIC IMAGING SYSTEM

A 2GHz, 17% tuning range quadrature CMOS VCO with high figure of merit and 0.6 phase error

Compact microstrip bandpass filter with tunable notch

System Level Design of a Continuous-Time Delta-Sigma Modulator for Portable Ultrasound Scanners

Phasor Measurement Unit and Phasor Data Concentrator test with Real Time Digital Simulator

Resolution Enhancement and Frequency Compounding Techniques in Ultrasound.

Effect of ohmic heating parameters on inactivation of enzymes and quality of not-fromconcentrate

Ultrasonic Linear Array Medical Imaging System

Data set reduction for ultrasonic TFM imaging using the effective aperture approach and virtual sources

Low-Cost Planar MM-Wave Phased Array Antenna for Use in Mobile Satellite (MSAT) Platforms Parchin, Naser Ojaroudi; Shen, Ming; Pedersen, Gert F.

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

3-D Vector Flow Using a Row-Column Addressed CMUT Array

Proceedings of Meetings on Acoustics

Antenna Diversity on a UMTS HandHeld Phone Pedersen, Gert F.; Nielsen, Jesper Ødum; Olesen, Kim; Kovacs, Istvan

An experimental vital signs detection radar using low-if heterodyne architecture and single-sideband transmission

Investigating the Electromechanical Coupling in Piezoelectric Actuator Drive Motor Under Heavy Load

Motion Compensation Improves Medical Ultrasound Image Quality

Implementation of Orthogonal Frequency Coded SAW Devices Using Apodized Reflectors

CoSMOS: Performance of Kurtosis Algorithm for Radio Frequency Interference Detection and Mitigation

Bandwidth limitations in current mode and voltage mode integrated feedback amplifiers

Set No.1. Code No: R

Body-Worn Spiral Monopole Antenna for Body-Centric Communications

Exercise 2: Simulation of ultrasound field using Field II

A Real-time Photoacoustic Imaging System with High Density Integrated Circuit

Coded excitations NINE. 9.1 Temporal coding

A high-speed CMOS current op amp for very low supply voltage operation

Random Thinning of Segmented Annular Arrrays

60 GHz antenna measurement setup using a VNA without external frequency conversion

Aalborg Universitet. MEMS Tunable Antennas to Address LTE 600 MHz-bands Barrio, Samantha Caporal Del; Morris, Art; Pedersen, Gert F.

A Novel SFG Structure for C-T Highpass Filters

Limitations in distance and frequency due to chromatic dispersion in fibre-optic microwave and millimeter-wave links

200-GHz 8-µs LFM Optical Waveform Generation for High- Resolution Coherent Imaging

Optimization of Axial Resolution in Ultrasound Elastography

Leaky-wave slot array antenna fed by a dual reflector system Ettorre, M.; Neto, A.; Gerini, G.; Maci, S.

Mathematical Modeling of Ultrasonic Phased Array for Obstacle Location for Visually Impaired

Sub-millimeter Wave Planar Near-field Antenna Testing

Multiplierless sigma-delta modulation beam forming for ultrasound nondestructive testing

Detection of Multipath Propagation Effects in SAR-Tomography with MIMO Modes

Investigation of a Hybrid Winding Concept for Toroidal Inductors using 3D Finite Element Modeling

Non resonant slots for wide band 1D scanning arrays

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa. Joanna X.Qiao 1, Matthias Jobst 2

Lesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions.

Dynamic range of low-voltage cascode current mirrors

Laitinen, Tommi. Published in: IEEE Transactions on Antennas and Propagation. Link to article, DOI: /TAP Publication date: 2008

Influence of insonification angle on echogenicity of B-mode images of atherosclerotic plaque in vitro

Transcription:

Downloaded from orbit.dtu.dk on: Dec 17, 217 Further development of synthetic aperture real-time 3D scanning with a rotating phased array Nikolov, Svetoslav; Tomov, Borislav Gueorguiev; Gran, Fredrik; Dufait, R.; Jensen, Jørgen Arendt Published in: 23 IEEE Symposium on Ultrasonics Proceedings Link to article, DOI: 1.119/ULTSYM.23.1293286 Publication date: 23 Document Version Publisher's PDF, also known as Version of record Link back to DTU Orbit Citation (APA): Nikolov, S., Tomov, B. G., Gran, F., Dufait, R., & Jensen, J. A. (23). Further development of synthetic aperture real-time 3D scanning with a rotating phased array. In 23 IEEE Symposium on Ultrasonics Proceedings (Vol. 2, pp. 1899-192). IEEE. (I E E E International Ultrasonics Symposium. Proceedings). DOI: 1.119/ULTSYM.23.1293286 General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

FURTHER DEVELOPMENT OF SYNTHETIC APERTURE REAL-TIME 3D SCANNING WITH A ROTATING PHASED ARRAY Svetoslav Ivanov Nikolov, Borislav Guerguiev Tomov, Fredrik Gran and Jørgen Arendt Jensen Center for Fast Ultrasound Imaging, Bldg 348, Ørsted DTU, Technical University of Denmark DK-28 Kgs. Lyngby, Denmark Abstract - In a previous paper we have presented an approach combining synthetic transmit aperture imaging with a rotating phased array. The method is implemented on a specially made Vermon transducer capable of rotating at 5 Hz. The center frequency of the transducer is 3.2 MHz, and the pitch is.22 mm. The array active diameter is 16 mm and the number of elements is 64. The method is capable of scanning 1 volumes/sec. The order in which the transmit elements were fired made it possible to achieve lateral resolution of a.94 mm at 45 mm depth, which is comparable to a standard B-mode scan. The penetration depth was >1 cm due to the use of 2 µs long frequency modulated (FM) pulses. The dynamic range was limited to 45 db because of the non-optimized FM pulse and grating lobes. This paper presents the work on improving the image quality of the approach: (1) instead of defocusing conventional focusing with an f-number of 1 is used in transmit to create spherical waves, (2) virtual receive elements are synthesized to decrease noise and grating lobes, (3) the compression filter for the FM pulses was modified to suppress the range lobes (4) additional hardware for synchronization is built. I OVERVIEW Real-time 3-D ultrasound imaging has been the goal of many researchers for over a decade. The main question is how to avoid the tradeoff between speed of acquisition and image quality. Lockwood et al. suggested the use of synthetic transmit aperture ultrasound imaging combined with mechanical motion of a phased array to scan 3-D volumes [1]. In that method, the array is rocking, and the planes are scanned and beamformed independently one from another using only a few emissions. The use of such a sparse aperture results in high side-lobes. In 22, we presented a new approach for acquiring the volume [2]. The transducer is not rocking, but instead it is rotating. The advantage of this method is that more pulseecho events can be used for the beamformation of a single point, thus yielding lower side- and grating-lobes. Figure 1 y θ z Transmission Reception Figure 1: Acquisition and beamformation. illustrates the acquisition method. A transducer is continuously rotating at a constant angular velocity. A cylindrical wave (such as the wave transmitted by a single element) is transmitted by a group of elements. This is symbolized on the figure with a dark filling color. All elements are used in receive. A point in the volume is formed by a simple delayand-sum beamformation: H( )= N i Ω mt ( ) j=1 a ij ( )r ij (t(, i, j )), (1) where are the coordinates of the point being formed, Ω mt ( ) is the set of transmissions, in which the cylindrical wave has passed through the imaged point, i is the center of the transmitted spherical wave, j is the position of the receiving element j, r ij (t) is the signal received by element j at transmission i, and N is the number of elements in the transducer. The time instance t(, i, j ), at which a sample for the sum is taken, corresponds to the propagation time from the center of transmission i to the beamformed point and back to the transducer element j : t = 1 c ( i + j ), (2)

where c is the speed of sound. The created images have a spatial resolution in the azimuth plane comparable to that of a standard B-mode scan [2]. The dynamic range, however, was limited to 45 db, which is less than conventional images. In order for a scan method to be adopted for imaging, it must not only offer new advantages, but must perform in all other aspects at least as good as the eisting methods. Several areas were identified as candidates for optimization: The generation of spherical waves. When the method was first implemented, the spherical waves were created by defocusing [1, 2, 3]. A similar effect could be achieved with focusing instead [4, 5]. i o j Depth [mm] 2 6 8 1 12 5 db Optimization of the FM chirps. The pulses and filters used in [2] were not designed using the impulse response of the system as suggested in [6]. The synchronization. The scans relied on the simultaneous start of the scan and the rotation of the transducer. Additional hardware for synchronization was to be built 1 2 2 Azimuth [mm] Figure 2: Delay calculations geometry (left). A B-mode slice created with a conventional pulse (right). Reduce the grating-lobe level by creating virtual receive elements, whose directivity pattern has a narrow main lobe. III OPTIMIZATION OF CHIRPS These topics are considered in the same order in the following sections of the paper. II SPHERICAL WAVE GENERATION Creating spherical waves is essential for the proposed method. There are two ways of generating spherical waves - using defocused or focused transmission. A defocused transmission with 13 transmit elements and a 2 µs chirp was used in [2]. This resulted in a penetration depth of up to 12 mm. Using a focused transmission has the advantage of increasing the energy sent into the body, thus increasing the penetration depth. Fig. 2 (left) shows the propagation path which must be used in the delay calculation for the beamfomration process [4]. The time at which a sample must be taken becomes (2): t = 1 c ( i o + i + j ), (3) where the focal point is considered to be the virtual element i, and o is the center of the aperture. The result of using focused transmits is shown in the Fig. 2 (right). The spherical wave was created using 15 transmit elements. The focusing is at a depth of 5 mm in front of the transducer. A conventional 2 cycles sine pulse is used as an ecitation in transmit. The cysts are detectable up to a depth of 1 mm, which is an increase of more than 2 mm compared to [2]. In order to attain a better SNR codes are deployed. Coded ecitation has previously been investigated in [6]. A linear FM chirp has been used as ecitation, s(t)=a(t)sin ( 2π f t + B 2T t2), T 2 t T 2, (4) where a(t) is a temporal weighting function, f is the center frequency, B is the bandwidth being swept and T is the duration of the chirp. To achieve an acceptable aial resolution, a compression filter has to be used. Normally a matched filter with a temporal weighting function is applied f (t)=g(t)s( t). (5) However, the signal which is received at the transducer is in fact given by r(t)=s(t) h ti (t) h tr (t), (6) where h ti (t) is the pulse echo impulse response of the interrogated tissue and h tr (t) is the pulse echo impulse response of the transducer. If the transducer pulse echo impulse response is known, one can compensate for it and replace (5) with, f (t) =g(t) s( t), (7) where s(t) =s(t) h tr (t). The side lobes are then reduced below -5 db as shown in Fig. 3.

Level [db] 2 New Previous the present value of the counter is stored in the SRAM. After the end of the acquisition, the stored values are read through the PCI interface in a Linu environment. The error in the recorded position is less than ±.3. V VIRTUAL RECEIVE ELEMENTS 6 8 1 5 5 1 Time [µs] Figure 3: Reduction of the range side lobes with the new filter design. For the different points in the image, a different number of transmissions is used as shown in Eq. 1. The points, which are close to the ais of rotation will be formed using a larger number of transmit events, and the points lying at the outskirts will be created with a smaller number of transmissions. The transmission order can be arranged such that the resolution of the image at all points is the same [4]. The side- and grating-lobe levels are, however, higher, when the number of emissions is less. IV SYNCHRONIZATION The Vermon (Cede, France) phased array rotating transducer is driven by a DC motor and controller supplied by Maon Motor AG (Sachseln, Germany). The position of the rotating block is indicated by a rotation encoder and an end switch. The two sensors in the encoding block generate differential signals. An illustration of the positive signals from both sensors is shown in Fig. 4 (top part). The direction of rotation determines which signal precedes the other. Grating lobe Main lobe A() Beam pattern for one element Channel A Figure 5: Illustration of suppression of the grating lobes Channel B Sensor A Sensor B new_line Filtration Detection dir pulse Counter SRAM Figure 4: Rotary encoder sensor signals PCI An angle detector was built using the XC2S EVAL board form CESYS GmbH (Herzogenaurach, Germany). The board features a PCI interface, Xilin Spartan-2 FPGA and a SRAM block. The structure of the detector is shown in Fig. 4 (bottom part). In that setup, the new_line signal is provided by a detection logic connected to one of the transmitter channels. The positive signals from both sensors are monitored and their relation is used to determine the position and the increment of a counter. Whenever a new image line acquisition is initiated, Fig. 5 shows how the grating lobes are suppressed. The distance between the grating lobes and the main lobe is inversely proportional to the number of elements in the aperture. The level of the grating lobes is suppressed by the radiation pattern of a single element. The bigger the element is, the lower the grating lobe level is. One way to decrease the grating lobes is to synthesize receive elements, which are large and have a narrow directivity pattern. The distance between the centers of the receive elements must be maintained at λ/2. The synthesis of receive elements is done by summing the signals from a number of elements prior to the beamformation. In order to maintain the sensitivity for the different directions in the image, the signals are delayed such that the synthesized element looks along scan line which will be beamformed (very much like a sunflower). Fig. 6 illustrates how a virtual receive element is synthesized. The dark dots mark the positions of the physical elements. The pale lines are the synthesized receive elements. The delays of the active elements, which are used to create one of the virtual receive elements are adjusted so as to align on the lines symbolizing the receive elements. If the currently beamformed line is perpendicular to the transducer

Synthesized element VI CONCLUSION Level [db] Physical element Aial Distance mm Active elements Figure 6: Illustration of the virtual receive elements 3 5 3 2 6 Standard receive Virtual rcv elements 5 2 2 6 Lateral Distance [mm] Standard Virtual rcv 2 2 Angle [deg] 1 2 3 5 Figure 7: Sidelobe reduction using virtual receive elements. surface, then synthesizing the receive elements is simply summing the received signals. If the beamformed line is tilted at an angle, then the signals must be appropriately delayed. Figure 7 shows the reduction in the side lobe level when virtual receive elements are used. The image is created using only 13 emissions, which is the number of emissions normally used to create the points at the outskirts of the volume. Five elements were used in receive to generate a virtual receive element. The plot shows that the side- and grating-lobe level is reduced with more than 1 db, which will correspondingly increase the contrast of the acquired images. The 3D synthetic aperture imaging technique with a rotating array is capable of scanning 1 volumes per second. Previously it was shown that the images had resolution as the conventional B-mode images. This paper presented the work on increasing the dynamic range and penetration depth of the images. The use of focused transmits allows to scan up to 1 mm with conventional sinusoidal pulses. The use of chirps increases the scan depth. The careful filter design suppresses the range side lobes to below -5 db. The use of virtual receive elements reduces the grating lobes for the points at the edge of the volume with more than 1 db. The method, thus, has the ability of generating 3D scans whose quality matches the quality of the conventional 2D scans. VII ACKNOWLEDGMENTS This work was supported by grant 97883, 97563 and 26-1-178 from the Danish Science Foundation and by B- K Medical A/S Denmark. VIII REFERENCES [1] G. R. Lockwood, J. R. Talman, and S. S. Brunke. Realtime 3-D ultrasound imaging using sparse synthetic aperture beamforming. IEEE Trans. Ultrason., Ferroelec., Freq. Contr., 45:98 988, 1998. [2] S. I. Nikolov, R. Dufait, A. Schoisswohl, and J. A. Jensen. Three-dimensional real-time synthetic aperture imaging using a rotating phased array transducer. In Proc. IEEE Ultrason. Symp., pages 1545 1548, 22. [3] M. Karaman, P. C. Li, and M. O Donnell. Synthetic aperture imaging for small scale systems. IEEE Trans. Ultrason., Ferroelec., Freq. Contr., 42:429 442, 1995. [4] S. I. Nikolov and J. A. Jensen. Virtual ultrasound sources in high-resolution ultrasound imaging. In Proc. SPIE - Progress in biomedical optics and imaging, volume 3, pages 395 5, 22. [5] M. H. Bae and M. K. Jeong. A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systems. In IEEE Trans. Ultrason., Ferroelec., Freq. Contr., volume 47, pages 151 1519, 2. [6] T. X. Misaridis and J. A. Jensen. An effective coded ecitation scheme based on a predistorted FM signal and an optimized digital filter. In Proc. IEEE Ultrason. Symp., volume 2, pages 1589 1593, 1999.