TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation

Similar documents
RM4000 Tektronix 4000 Series Rackmount Kit

RM4000 DPO4000 Series Rackmount Kit

RMD3000 DPO3000 Series Rackmount Kit

RMD5000 Rackmount Kit Instructions

RMD2000 DPO2000 and MSO2000 Series Rackmount Kit Instructions

RM5 Rackmount Kit Instructions

Powerware Series. Eaton Rail Kit 9- and 12-Slot Cabinets Installation Guide

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

LAN Locker Adjustable Shelves

S6 User s Manual USER S MANUAL ver. 1.0

4Post and 2Post Sliding Rails for Lenovo/IBM M5

4Post and 2Post Rails for Dell PowerEdge R810

INSTRUCTION BOOKLET #C20

INSTALLATION INSTRUCTIONS

Desk/Wall-Mount Rack

Slide Rail Kit DVA-ASRK-28A DVA-ASRK-36A. Installation Manual

Mighty Mo GX Series Cabinet Installation Guide. OR Rev /11

INSTRUCTION BOOKLET #C21. For Wallbed models: KING SIZE

Agilent N2902A 9000 Series Oscilloscope Rack Mount Kit

INSTRUCTION BOOKLET #34. For Wallbed models: KING SIZE SIERRA WITH STORAGE HEADBOARD

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

Y1160A EIA Rack Sliding Shelf Installation Note

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

Agilent G1585A Side Carrier for Manual Inlet Flow Module

WILDING WALLBEDS INSTALLATION INSTRUCTION Side Mount

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

SM-RAZOR-ART2-L / SM-RAZOR-ART2-XL

TABLE MKI small with Basin and under rack brackets kit

Side Mount INSTRUCTION BOOKLET #C122 BED STYLE: PARK CITY

OXYGEN INSTALLATION. Revision date


INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110


VACUSEAL MODEL 200. HOT TUB PRODUCTS 233 Carrington Road Bethany CT


INSTALLATION INSTRUCTIONS

MODEL 9301E. Extra Heavy Duty Full Extension Drawer Slide Up to 600-lb. [272 kg.] Load Rating Optional Accessory Platform Brackets*

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

Installing the Profile Privacy Panel. Assemble top mounting bracket. Prerequisites. Tools


REC Series Rack Installation Guide

ASSEMBLY & INSTALLATION GUIDE

Installation Instructions

INSTALLATION INSTRUCTIONS Small Flat Panel FMA Pivot Arrays Models: FMA-220 and FMA-320

Installing flat panels on the MPL15 wall mount

PULL-THRU USER S MANUAL

INSTALLATION MANUAL. All Recessed Wall-Mount Modules Front-Loading, Rear-Loading, Parcel-Only, Collection Box, Trash/Recycling Bin

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

2015 RIGOL TECHNOLOGIES, INC.

MANUAL e130. Wallstation

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

BOX-117 E-Z-Go RXV Utility Box Mounting Kit Installation Instructions

SEAT-361 E-Z-Go RXV RHOX Seat Kit Installation Instructions

Installation Instructions

OPERATION AND MAINTENANCE FOR MODEL MRV050A REVERSIBLE

SANnet II Family Rack Installation Guide for 2U Arrays

table brackets for mki table incl latch TBRA020

TOYOTA TACOMA BED EXTENDER Preparation. Part Number: PT

Range height adjustable assembly

TOYOTA TACOMA BED EXTENDER Preparation. Part Number: PT General Applicability All 2012 and newer Tacoma models

WEIGHT ADJUSTABLE ESPREE. Model 2ESP-WA-C48- Model 2ESP-WA-C60- 2ESP-WA Rev B 8/17 ASSEMBLY AND OPERATION

LCD DISPLAY MOUNT

PHTM200 - Phantom 200 Flat Screen Wall Mount with Wafer Thin Projection Fits Screens up to 50 lbs with 200mm Mounting Patterns

IBM xseries 345 Third Party Slide Rail Kit

Codonics SLS 500i Shelf Installation

INSTALLATION INSTRUCTIONS Medium Flat Panel Model MSP-SI1

ALUMA-CLASSIC FENCE W1716 & W1720 INSTRUCTION MANUAL

3 BAY AV CREDENZA WITH SINGLE DISPLAY MOUNT

F l a t S c r e e n A R M S I n s t a l l a t i o n

Tilting Flat Panel Wall Mount Installation Guide

Equilibrium. Conference Table. Installation Instruction. Revision B 11/07/16

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

Installation Instructions For Slider Casement Air Conditioners

VACUSEAL MODEL 300 & 400

JEEP JK ( 3 DOOR ) SLIMLINE II - FULL TRAY EXTREME RACK KIT

HERCULES EXTENDED TOWER

Installation Instructions

INSTALLATION MANUAL FRONT. See pages 2 and 3 of this manual for configuration options. Level of Difficulty. Product Photo (center section only)

Assembly Instructions 10 X 10 Aluminum Frame Building

INSTALLATION INSTRUCTIONS

JEEP JK ( 3 DOOR ) SLIMLINE II - FULL TRAY EXTREME RACK KIT

Pro Ski / Snowboard & Fishing Rod Carrier

MODULAR BUMPER INSTALLATION MANUAL

DEC 3000 Models 500/500S/800/800S/900/900S AXP Rackmount Installation Guide

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

Y1160A EIA Rack Sliding Shelf Installation Note

2015 Current Ford F150/Raptor Adaptive Cruise Control Module Relocation Bracket Installation Instructions

6 BAY AV CREDENZA WITH DUAL DISPLAY MOUNT

RBP-1215B-RX DODGE RAM QUAD CAB RX3

Showpiece Cabinet Integrated Stand For 32" - 52" LCD HDTV

Sliding Door Kit

SmartView Mounting Frame 3 Wide x 3 Deep Video Wall Display Installation Guide

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

(2) Plastic Plugs (2) Frame Bracket. Spacers. License Plate Bracket. (2) 12mm Single Bolt Plates. (2) 12mm Double Bolt Plates

COPPER / FIBER MANAGER RACK INSTALLATION INSTRUCTIONS PX Standard Release A March 2008

V00029KX READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID

Installation Guide Installation Kit for Mounting Philips MP20/30/40/50 on Datex-Ohmeda Aisys Anesthesia Machine

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

TOYOTA TUNDRA CARGO DIVIDER Preparation. Part Number: PT

Transcription:

Instructions 020-2369-02 TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation 071-0897-01 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service. www.tektronix.com 071089701

Copyright Tektronix, Inc. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. Contacting Tektronix Tektronix, Inc. 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA For product information, sales, service, and technical support: In North America, call 1-800-833-9200. Worldwide, visit www.tektronix.com to find contacts in your area.

Table of Contents General Safety Summary... ii Service Safety Summary... iii Installation Instructions... 1 Install the Rackmount Kit Hardware on the Instrument... 2 Install the Tracks in the Rack... 4 Install the Mainframe in the Rack... 8 Replaceable Parts... 11 Parts Ordering Information... 11 Using the Replaceable Parts List... 12 TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation i

General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only qualified personnel should perform service procedures. While using this product, you may need to access other parts of the system. Read the General Safety Summary in other system manuals for warnings and cautions related to operating the system. Provide Proper Ventilation. Refer to the manual s installation instructions for details on installing the product so it has proper ventilation. Symbols and Terms Terms in this Manual. These terms may appear in this manual: WARNING. Warning statements identify conditions or practices that could result in injury or loss of life. CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property. Terms on the Product. These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the product. Symbols on the Product. The following symbols may appear on the product: CAUTION Refer to Manual ii TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation

Service Safety Summary Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary before performing any service procedures. Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present. Disconnect Power. To avoid electric shock, switch off the instrument power, then disconnect the power cord from the mains power. Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components. To avoid electric shock, do not touch exposed connections. To avoid potential hazzards, use this product only as specified. To prevent the instrument and rack from falling onto the operator, use two or more people to install the instrument into the rack cabinet. After completing the installation procedure, verify that the instrument and the rack cabinet will not tip forward while the instrument is extended out of the rack. TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation iii

Service Safety Summary iv TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation

Installation Instructions These instructions provide information for installing the 020-2369-02 TLA72X, TLA7XM, and TLA7016 Benchtop Mainframe Rackmount kit. Refer to Site Considerations in the Getting Started chapter of the Tektronix Logic Analyzer Family User Manual for cooling clearance information. You can install the rackmount kit to either recess the mainframe into the front of mainframe rack or to mount it flush with the front of the mainframe rack. The steps for installing the rackmount kits consist of installing the rackmount hardware to the mainframe, installing the tracks in the rack, and then installing the mainframe in the rack. You will need the following tools to install the rackmount options: T-10 Torx driver T-15 Torx driver #2 Phillips screwdriver 3/32 in Hex driver WARNING. Because of the size and weight of the mainframe, use care when lifting or moving the mainframe to avoid personal injury while performing the installation procedures. Use two people to lift or move the mainframe. TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation 1

Installation Instructions Install the Rackmount Kit Hardware on the Instrument Perform the following steps to install the rackmount kit hardware: 1. Remove the rubber feet from the mainframe. 2. Determine where you want the mainframe positioned in the rack. (The bracket holes allow you to mount the mainframe flush with the front rails or recessed inside the rack). 3. Install the rackmount bracket using two 8-32 screws included with the kit. (See Figure 1). Repeat this step for the other bracket. Screws (2) Latch is located at the rear. Track Screws (2) Screws (5) Handle Bracket Figure 1: Mounting the brackets to the mainframe 2 TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation

Installation Instructions 4. Remove the five rearward 8-32 screws from both sides of the mainframe (leave the front screws in). See Figure 2. Screws (5) Track Screws (2) Spacer plate Latch is located at the rear. Track Screws (2) Screws (5) Handle Bracket Figure 2: Installing the inside tracks 5. Attach the inside tracks to the sides of the mainframe: a. Add the spacer plate between the left inside track and mainframe. Orient the button latch so that it faces away from the mainframe and toward the rear. See Figure 2. b. Attach the left inside track and spacer to the left side of the mainframe using five 8-32 flathead screws. c. A spacer is not necessary on the right side. Attach the right inside track to the right side of the mainframe using five 8-32 flathead screws. TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation 3

Installation Instructions Install the Tracks in the Rack 1. Identify the right and left slide-out track assemblies. The button latch is closest to the top of the track. See Figure 3. Right Side Slide-Out Track Assembly Outer track Button latch is closest to top of track. Inner track Front Flange (mounts to front rail of rack) Figure 3: Identifying the slide-out track assemblies 4 TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation

Installation Instructions 2. Measure the distance between the front and rear rail of the rack. See Figure 4. 3. Align the rear bracket to the right slide-out track as shown in Figure 4. Note that the rear bracket has two pairs of mount-through holes. When aligning the bracket and the track, select a pair of holes that mount the rear bracket so the flange-to-flange distance matches the front rail to rear rail spacing that you just measured in step 2. 4. Attach the rear bracket to the right slide-out track using two 10-32 screws and a bar nut as shown in Figure 4. Leave the screws loose so that you can adjust the overall length of the slide-out track assembly when installing the mainframe in the rack. Use the extended length brackets to comply with deeper rackmounts. 5. Repeat steps 3 and 4 to assemble the left slide-out track assembly. Extended length bracket for deep racks Bracket Outer track Button latch is closest to top of track. Front Flange (mounts to front rail of rack) Measurement for Rail Figure 4: Measuring and assembling the slide-out track assemblies TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation 5

Installation Instructions 6. Select the mounting position in the rack: Select two 0.5-inch spaced holes in the front rail and verify that the 1.5-inch and 12.0-inch clearances exist relative to the mounting holes as shown in Figure 5. 12.0 in (304.8 mm) 14.0 in (355.6 mm) Left-front rail 1.5 in (38.1 mm) 0.5 in (12.7 mm) (For correct position of securing holes) Figure 5: Vertical clearance for rack installation (standard mainframe) 6 TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation

Installation Instructions 7. Select the mounting method for the next step according to the rack type: To mount the slide-out tracks with the front and rear flanges outside of the front and rear rails, use method A shown in Figure 6. Add a bar nut to the installation only if the rails have untapped holes. To mount the slide-out tracks with the front and rear flanges inside of the rails, use mounting method B shown in Figure 6. Use this mounting method when the rails have untapped holes. 8. Using the mounting method determined from the previous step, secure the right slide-out track assembly to the front and rear rails. Seat the screws fully, but lightly, so that you can adjust the mounting later. 9. Tighten the screws left loose in step 4 to fix the front to rear flange spacing of the slide-out track assembly. 10. Repeat steps 6 through 9 to mount the left slide-out track assembly. Left slide-out track Left slide-out track Use a bar nut if front rails are not tapped. Left-front rail Left-front rail 10-32 Pan head screws (4) Mounting method A 10-32 Flat head screws (4) Use two flat head screws if the cabinet rails have countersunk mounting holes; otherwise, use two pan head screws. Mounting method B 10-32 Pan head screws (4) Figure 6: Installing the slide-out track assemblies in the rack (top view) TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation 7

Installation Instructions Install the Mainframe in the Rack WARNING. Because of the size and weight of the mainframe, installing the mainframe by yourself can result in personal injury or equipment damage. Installing the mainframe in the rack requires at least two people. One person should be on the left side of the mainframe with one hand holding the left front handle and with the other hand underneath the mainframe. The other person should do likewise on the right side of the mainframe. 11. Fully extend the inner tracks of each slide-out section out of the front of the rack until they lock. WARNING. To prevent the mainframe from tipping or dropping during installation, at least two people should install the mainframe into the cabinet. After completing the installation, verify that the mainframe and the cabinet will not tip forward when the mainframe is in the fully extended position. 12. Lift the mainframe and insert the left and right tracks that extend from the rear of the mainframe into the ends of the tracks that you just extended. Make sure that the tracks mounted on the mainframe slip just inside the inner tracks from the instrument rack. 13. Slide the mainframe back until it stops. 14. Push to release the button latches, located on the outside of each track, and continue to slide the mainframe all the way back into the rack cabinet. 15. Tighten the four screws that you left loose at the rear of the rack when you performed step 8, and pull the mainframe part way out of the rack. (Tighten the 10-32 screws using 28 inch-lbs of torque.) 16. Be sure that the screws that you left loose at the front of the rack are loose enough to allow the slide-out track assemblies to seek the normal positions. 17. Tighten the screws and push the mainframe all the way into the rack. If the tracks do not slide smoothly, readjust the level using the method described in steps 15 and 16. (Tighten the 10-32 screws using 28 inch-lbs of torque.) 18. Install the proper power cord at the rear of the mainframe. 8 TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation

Installation Instructions NOTE. To ensure the mainframe is properly mounted in the rack, do not tighten the screws while installing the chassis track to the rack front rails. After all the mounting screws have been installed, shift the mainframe to the far right of the rack, then tighten all the mounting screws. Refer to Figure 7 for screw positions. Depending on the rack manufacturer it may be necessary to use an additional spacer plate. Rack front rail Chassis slide assemblies Left rack rail & chassis slide assembly Spacer plate Right rack rail & chassis slide assembly Rack front rail Chassis slide assemblies Shift the mainframe to the far right. Do not tighten the screws until all screws are touching the left side of the slots. Figure 7: Rackmounting screw positions (front view) TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation 9

Installation Instructions 10 TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation

Replaceable Parts This section contains a list of the replaceable modules for the Rackmount Kit. Use this list to identify and order replacement parts. Parts Ordering Information Replacement parts are available through your local Tektronix field office or representative. Changes to Tektronix products are sometimes made to accommodate improved components as they become available and to give you the benefit of the latest improvements. Therefore, when ordering parts, it is important to include the following information in your order. Part number (see Part Number Revision Level below) Instrument type or model number Instrument serial number Instrument modification number, if applicable If you order a part that has been replaced with a different or improved part, your local Tektronix field office or representative will contact you concerning any change in part number. Part Number Revision Level Tektronix part numbers contain two digits that show the revision level of the part. For most parts in this manual, you will find the letters XX in place of the revision level number. Part Number Revision Level Revision Level May Show as XX 670-7918-03 670-7918-XX When you order parts, Tektronix will provide you with the most current part for your product type, serial number, and modification (if applicable). At the time of your order, Tektronix will determine the part number revision level needed for your product, based on the information you provide. TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation 11

Replaceable Parts Using the Replaceable Parts List This section contains a list of the mechanical and/or electrical components that are replaceable for the IntelliFrame Mainframe Use this list to identify and order replacement parts. The following table describes each column in the parts list. Parts List Column Descriptions Column Column name Description 1 Figure & Index Number Items in this section are referenced by figure and index numbers to the exploded view illustrations that follow. 2 Tektronix Part Number Use this part number when ordering replacement parts from Tektronix. 3 and 4 Serial Number Column three indicates the serial number at which the part was first effective. Column four indicates the serial number at which the part was discontinued. No entries indicates the part is good for all serial numbers. 5 Qty This indicates the quantity of parts used. 6 Name & Description An item name is separated from the description by a colon (:). Because of space limitations, an item name may sometimes appear as incomplete. Use the U.S. Federal Catalog handbook H6-1 for further item name identification. 7 Mfr. Code This indicates the code of the actual manufacturer of the part. 8 Mfr. Part Number This indicates the actual manufacturer s or vendor s part number. Abbreviations Abbreviations conform to American National Standard ANSI Y1.1-1972. Mfr. Code to Manufacturer Cross Index The table titled Manufacturers Cross Index shows codes, names, and addresses of manufacturers or vendors of components listed in the parts list. 12 TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation

Replaceable Parts Manufacturers cross index Mfr. code Manufacturer Address City, state, zip code 0KB01 STAUFFER SUPPLY CO 810 SE SHERMAN PORTLAND, OR 97214-4657 06666 GENERAL DEVICES PO BOX 39100 INDIANAPOLIS, IN 48239 TK1943 NEILSEN MANUFACTURING INC 3501 PORTLAND RD NE SALEM, OR 97303 80009 TEKTRONIX INC 14150 SW KARL BRAUN DR PO BOX 500 BEAVERTON, OR 97077-0001 TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation 13

Replaceable Parts Replaceable parts list Fig. & index number Tektronix part number Serial no. effective Serial no. discont d Qty Name & description Mfr. code Mfr. part number 8-0 020-2369-XX 1 COMPONENT KIT:RACKMOUNT KIT 1R, SILVER GRAY; 80009 020-2369-XX TLA72X, TLA7XM, & TLA7016-1 950-0991-00 2 HANDLE ALUMINUM BLK 80009 950-0991-00-2 212-0157-00 14 SCREW,MACHINE:8-32 X 0.5,FLH,100 DEG,STL CDPL,T -15 0KB01 ORDER BY DESC -3 407-4524-00 1 BRACKET:LEFT,RACKMOUNT,SILVER GRAY TK1943 407-4524-00-4 212-0671-00 4 SCREW,MACHINE:10-32 X 0.625,FLH,100 DEG,STL,CD PL, 0KB01 ORDER BY DESC TORX -5 407-4525-00 1 BRACKET:RIGHT, RACKMOUNT,SILVER GRAY TK1943 407-4525-00-6 351-1010-00 1 GUIDE:RACK SLIDE EXTENSION BRACKET,CLOSED 06666 B-814-2 SLOT,9.7 X 8.1 INCHES (PAIR) -7 351-0800-00 1 GUIDE,SLIDE:CHASSIS TRACK, (PAIR) 06666 CTS-124-8 386-6999-00 1 PLATE,LEFT:OFFSET SPACER,16 X 1.45,0.062 THICK AL TK1943 386-6999-00-071-0897-01 1 MANUAL TECH: INSTRUCTIONS, TLA72X, TLA7XM, & TLA7016 BENCHTOP MAINFRAME RACKMOUNT INSTALLATION, DP 80009 071-0897-01 14 TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation

Replaceable Parts 3 4 2 1 5 2 6 2 8 6 7 7 2 Figure 8: Rackmount assembly End of document TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation 15