A new approach in determining the load transfer mechanism in fully grouted bolts

Similar documents
Double Shear Testing of Bolts

A New Technique to Determine the Load Transfer Capacity of Resin Anchored Bolts

Rock and bolt properties and load transfer mechanism in ground reinforcement

Modelling of Rebar and Cable Bolt Behaviour in Tension/Shear

HACETTEPE UNIVERSITY MINING ENGINEERIN DEPARTMENT

Module 10 : Improvement of rock mass responses. Content

Design of structural connections for precast concrete buildings

Numerical Modeling of Grouted Soil Nails

NUMERICAL ANALYSIS OF SCREW ANCHOR FOR CONCRETE

Development, Trials and Testing of a Two Componet Rapid Set Cement Grouting System

Strength Properties of Fibre Glass Dowels Used for Strata Reinforcement in Coal Mines

Factors Affecting Pre-Tension and Load Carrying Capacity in Rockbolts - A Review of Fastener Design

Evaluating methods of underground short encapsulation pull testing in Australian coal mines

Failure of Engineering Materials & Structures. Code 34. Bolted Joint s Relaxation Behavior: A FEA Study. Muhammad Abid and Saad Hussain

NALYSIS OF STABILIZING SLOPES USING VERTICAL PILES

Optimum Design of Nailed Soil Wall

SIMULATION AND EXPERIMENTAL WORK OF SINGLE LAP BOLTED JOINT TESTED IN BENDING

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications.

Sample Size and Sample Strength Effects on Testing the Performance of Cable Bolts

STRUCTURAL TIMBER DESIGN

Contents. Notes on the use of this publication

Improving the performance of FBG sensing system

Hours / 100 Marks Seat No.

INFLUENCE OF PILES ON LOAD- SETTLEMENT BEHAVIOUR OF RAFT FOUNDATION

Moment Resisting Connections for Load Bearing Walls

The Behaviour Of Round Timber Sections Notched Over The Support On The Tension Face. Justin Dewey

3-D Finite Element Analysis of Bolted Joint Using Helical Thread Model

Hanger bolts and solar fasteners in sandwich panels

STABILITY. SECURITY. INTEGRITY.

Nonlinear behavior of Reinforced Concrete Infilled Frames using ATENA 2D

Experimental and numerical investigation of tube sinking of rectangular tubes from round section

Sliding shear capacities of the Asymmetric Friction Connection

Effect of Bolt Layout on the Mechanical Behavior of Four Bolted Shear Joint

DESIGN OF MACHINE MEMBERS-I

Finite Element Analysis of Multi-Fastened Bolted Joint Connecting Composite Components in Aircraft Structures

Experimental And FE Analysis Of Eccentric Loaded Symmetrical And Unsymmetrical Bolted Joint With Bolt Pretension

A Study on Effect of Sizing Bolt Hole in Single-Lap Connection Using FEA

Anti-check bolts as means of repair for damaged split ring connections

Comparison of behaviour of laterally loaded round and squared timber bolted joints

Prying of a Large Span Base Plate Undergoing a Moment Load Applied by a Round Pier

APPLICATION FOR APPROVAL OF A IENG EMPLOYER-MANAGED FURTHER LEARNING PROGRAMME

1/2/2016. Lecture Slides. Screws, Fasteners, and the Design of Nonpermanent Joints. Reasons for Non-permanent Fasteners

Numerical Analysis of Piled Raft Foundation using Fem with Interaction Effects

SEISMIC BEHAVIOR OF BEAM-TO-COLUMN DOWEL CONNECTIONS: NUMERICAL ANALYSIS VS EXPERIMENTAL TEST

Reinforcement with Soil Nails

Harmonic impact of photovoltaic inverter systems on low and medium voltage distribution systems

FiReP GRP Bolts. Bolting systems for mining and tunnelling. Solutions from Materials Technology

PRO LIGNO Vol. 11 N pp

An Investigation of Optimal Pitch Selection to Reduce Self-Loosening of Threaded Fastener under Transverse Loading

Innovative composite dowel for steel concrete composite bridges. Neil Westmacott, Wolfram Schwarz

2015 BBUGS Suppliers Day Jennmar Queensland Presentation A Review of Cable Support Systems from Jennmar

Mechanical behavior of fiberglass reinforced timber joints

ANALYSIS OF PILE-RAFT FOUNDATIONS NON- RESTED AND DIRECTLY RESTED ON SOIL

Glued laminated timber beams repair.

ENHANCING THE PERFORMANCE OF DISTANCE PROTECTION RELAYS UNDER PRACTICAL OPERATING CONDITIONS

Materials. Density, Hooke's law, Young modulus. 174 minutes. 174 marks. Page 1 of 29

AN INNOVATIVE FEA METHODOLOGY FOR MODELING FASTENERS

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Fastener Modeling for Joining Parts Modeled by Shell and Solid Elements

Stress Analysis of T-Flange Bolted Joint with a Simplified Spring and Beam Model

COL504 : SIMPLE USER S GUIDE ON ROOF SUPPORT INSTALLATION AND EVALUATION

Drawing of Hexagonal Shapes from Cylindrical Cups

CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION

Journal of American Science 2015;11(8) Soil Nailing For Radial Reinforcement of NATM Tunnels

An Alternative Formulation for Determining Stiffness of Members with Bolted Connections

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

Effect of Pile Bending Stiffness on Static Lateral Behavior of a Short Monopile in Dry Sand

DEVELOPMENT OF NEW TESTING PROCEDURE FOR THE ENCAPSULATED ROOF BOLT INSTALLATION IN COAL MINES ASSESSMENT OF RESIN PERFORMANCE FOR IMPROVED

LABORATORY EVALUATION OF CONCRETE-FILLED GFRP DOWELS IN JOINTED CONCRETE PAVEMENTS

Module 2 WAVE PROPAGATION (Lectures 7 to 9)

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training

Study on embedded length of piles for slope reinforced with one row of piles

LOAD CARRYING CAPACITY OF METAL DOWEL TYPE CONNECTIONS OF TIMBER STRUCTURES

Design and Analysis of Progressive Die for Chain Link Plate

Dynamic Analysis of Infills on R.C Framed Structures

CH # 8. Two rectangular metal pieces, the aim is to join them

THE INFLUENCE OF GEOMETRIC PARAMETERS AND MECHANICAL PROPERTIES OF ADHESIVE ON STRESS ANALYSIS IN ADHESIVELY BONDED ALUMINUM SINGLE LAP JOINT

a) If a bolt is over-tightened, which will fail first the bolt, or the plastic?

Keywords: Bracing bracket connection, local deformation, selective pallet racks, shear stiffness, spine bracings.

Modeling Multi-Bolted Systems

Full Contents. InRoads Essentials

Characteristics of Stay Cable Dry Galloping and Effectiveness of Spiral Protuberance Countermeasures

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training

The predictive model for strength of inclined screws as shear connection in timber-concrete composite floor

Structural Strength of Lapped Cold-Formed Steel Z-Shaped Purlin Connections with Vertical Slotted Holes

Revised Curriculum for Bachelor of Computer Science & Engineering, 2011

Development of a Numerical Technique for the Static Analysis of Bolted Joints by the FEM

TEST PROCEDURE FOR DYNAMIC PULL-THROUGH PERFORMANCE OF ROOFING MEMBRANES OVER FASTENER HEADS OR FASTENERS WITH METAL BEARING PLATES

Early Days of Rock Mechanics and Strata Control

Finite Element Modeling of Early Stage Self-loosening of Bolted Joints Haoliang Xu 1, a, Lihua Yang 1, b,, Lie Yu 1,2, c

Indian Journal of Engineering An International Journal ISSN EISSN Discovery Publication. All Rights Reserved

Dowel connections in laminated strand lumber

INFLUENCE OF SOME MODIFICATIONS OF LOCAL GEOMETRY ON THE STRESS STATES IN ADHESIVE BONDED LAP JOINTS

Instruction Manual for installing

MODELLING OF CONCRETE PAVEMENT DOWEL-SLAB INTERACTION

Grinding polycrystalline diamond using a diamond grinding wheel

3D Non-Linear FEA to Determine Burst and Collapse Capacity of Eccentrically Worn Casing

Effect of Masonry Infills on Seismic Performance of RC Frame Buildings

The Stamina of Non-Gasketed, Flanged Pipe Connections

Transcription:

University of Wollongong Research Online University of Wollongong Thesis Collection 1954-2016 University of Wollongong Thesis Collections 2006 A new approach in determining the load transfer mechanism in fully grouted bolts Hossein Jalalifar University of Wollongong Recommended Citation Jalalifar, Hossein, A new approach in determining the load transfer mechanism in fully grouted bolts, PhD thesis, School of Civil, Mining and Environmental Engineering, University of Wollongong, 2006. http://ro.uow.edu.au/theses/855 Research Online is the open access institutional repository for the University of Wollongong. For further information contact the UOW Library: research-pubs@uow.edu.au

NOTE This online version of the thesis may have different page formatting and pagination from the paper copy held in the University of Wollongong Library. UNIVERSITY OF WOLLONGONG COPYRIGHT WARNING You may print or download ONE copy of this document for the purpose of your own research or study. The University does not authorise you to copy, communicate or otherwise make available electronically to any other person any copyright material contained on this site. You are reminded of the following: Copyright owners are entitled to take legal action against persons who infringe their copyright. A reproduction of material that is protected by copyright may be a copyright infringement. A court may impose penalties and award damages in relation to offences and infringements relating to copyright material. Higher penalties may apply, and higher damages may be awarded, for offences and infringements involving the conversion of material into digital or electronic form.

A NEW APPROACH IN DETERMINING THE LOAD TRANSFER MECHANISM IN FULLY GROUTED BOLTS A thesis submitted in fulfillment of the requirements for the award of the degree DOCTOR OF PHILOSOPHY from UNIVERSITY OF WOLLONGONG By HOSSEIN JALALIFAR B.Sc, M.Sc. Rock Mechanics School of Civil, Mining and Environmental Engineering 2006

IN THE NAME OF GOD THE MOST GRACIOUS, THE MOST MERCIFUL This thesis is especially dedicated to my family. To my mother, for her unfailing support and long patience, I am extremely grateful of her. To my wife, Zahra Jamali, for her support, understanding and sacrifice over theses years and also to my little beautiful daughter, Fatemeh Jalalifar, who was eagerly waiting for me every night to come back home, although I could not spend as much time as I wished with her, I am truly grateful. My brother, Mohammad, who lost his children in Bam s Quack And other relatives who suffered intensively from the Bam s Quack For their love, encouragement, support and patience

AFFIRMATION I, Hossein Jalalifar, declare that this thesis, submitted in fulfillment of the requirements for the award of Doctor of Philosophy, in the School of Civil, Mining and Environmental Engineering, Faculty of Engineering, University of Wollongong, is wholly my own work unless otherwise referenced or acknowledged. The thesis was completed under the supervision of A/Prof. N.I.Aziz and A/Prof. M.S.N. Hadi and has not been submitted for qualification at any other academic institution. Hossein Jalalifar 2006 i

The following publications are the result of this thesis project: 1- Jalalifar, H., Aziz,N.I, Hadi. M.S.N. (2004), Modelling of sheared behaviour bolts across joints. Proceedings of 5 th Underground Coal Operators, Conference, convened by the Illawarra Branch of the Australian Institute of Mining and Metallurgy, Univ. of Wollongong, Wollongong, Australia, pp. 225-232. 2- Jalalifar, H. Aziz. N.I, Hadi. M.S.N. (2004), Shear behaviour of bolts in joints with increased confining pressure conditions, Proceedings of the International Mining Symposium, 2-3 June, Aachen, Germany, pp. 211-226. 3- Aziz, N.I. Jalalifar, H., Hadi. M.S.N. (2004), The effect of rock strength on shear behaviour of fully grouted bolts, Proceedings of the Fifth International Symposium on ground support in Mining and Underground Construction, 28-30 September, Perth Australia, pp. 243-251. 4- Jalalifar, H. Aziz, N.I, Hadi, M.N.S. (2004), Non-linear analysis of boltgrout-concrete interaction in reinforced shear joint, International Journal of Mines, Metals &Fuels, Vol 52, No 9&10, pp.208-216. 5- Jalalifar, H., Aziz, N.I, Hadi, M.S.N. (2004), Effective factors on reinforced shear joints, Proceedings of the 2 nd Iranian rock mechanics conference, Tarbiat Moddarres University, Tehran, Iran, pp. 475-485 (Farsi). 6- Jalalifar, H., Aziz.N.I. (2005), Load transfer in bolt bending, Proceedings of the 1 st Iranian mining conference, Tarbiat Moddarres University, Tehran, Iran, pp.1765-1775. 7- Jalalifar, H., Aziz, N.I., Hadi, M.S.N. (2005), Modelling of Shearing Characteristics of reinforced concrete, Int. Symp of Global Construction: Ultimate Concrete Opportunities, UK, pp. 543-556. ii

8- Aziz, N.I., Jalalifar, H., Hadi, M.S.N. (2005), The effect of resin thickness on bolt-grout-concrete interaction in shear, Proceeding of the 6 th Underground coal operators conference, Brisbane, Queensland University, Australia, pp. 3-10. 9- Seedsman.R, Jalalifar, H., Aziz, N.I. (2005), Chain pillar design, can we? Proceedings of the 6th Underground coal operators conference, Brisbane, Queensland University. Australia, pp. 59-62. 10- Aziz,N.I., Jalalifar, H., Hadi, M.S.N. (2005), Resin thickness effect on load transfer, Proceedings of the 19 th International mining Congress and fair of Turkey, pp. 65-72. 11- Jalalifar, H., Aziz,N.I.A, Hadi.M.S.N. (2005), 3D behaviour of reinforced rock joints, Proceedings of the 20 th World Mining Congress and Expo., 7-10 Nov., Tehran. Iran, pp. 629-639. 12- Aziz, N.I., Jalalifar, H. (2005), Rock bolt Load transfer capacity assessment methodology, 24 th Int. Symposium on ground control in mining, West Virginia, Morgantown, pp. 285-293. 13- Refereed: Jalalifar.H, Aziz, N.I., Hadi, M.S.N. (2005), The effect of bolt profile, rock strength and pretension load on bending behavior of fully grouted bolts, International Journal of Geotechnical and geological engineering. 14- Aziz, N.I, Jalalifar, H. (2005), Investigation into the transfer mechanism of loads in grouted bolts, Journal and news of the Australian Geomechanics Society, Vol. 40, No.2, pp.99-112. iii

ACKNOWLEDGEMENTS I wish to express my sincere gratitude to my thesis supervisor A/Prof. Naj.I. Aziz, faculty of engineering University of Wollongong, for his supervision, generous support, encouragement, and guidance provided during the research and also providing the necessary facilities to conduct my research work during three years. I would also like to express my sincere thanks to A/Prof. Muhammad Hadi my thesis co-supervisor for his helpful advice in this thesis particularly in numerical simulations. I also wish to express my sincere thanks for helpful contributions and comments made by Dr Seedsman and also Dr Alex for helpful assistance in Numerical modelling. I also would like to thank the technical staff in the School of Civil, Mining and Environmental Engineering, especially Bob Rowlan, Alan Grant, for laboratory assistance and also Ian Bridge and Ian laird. I greatly appreciate the contributions made by Mr Des Jemison, Mrs.Leonie McIntyre and Mr Peter Turner of the ITS staff. The assistance provided by the Faculty of Engineering, University of Wollongong, in particular Mrs Lorelle Pollard is also appreciated. I would like to acknowledge with sincere appreciation, the financial support of the Ministry of Science, Research and Technology of the Islamic Republic of Iran and the Kerman University for awarding me a research scholarship through which the complete financial support for this research was provided. I also would like to thank Bill Huuskes manager of the Metropolitan Colliery and Rod Doyl geotechnical engineer of Appin Colliery for their great assistance in field work. Most importantly, I would also like to express my great thanks to my wife and little daughter for their patients here and mother and brothers in Iran who have provided continued support throughout this study. I would also like to thank all my fellow Iranian at Wollongong University in Particular Mr Saeid Hesami, Mr Mohammad Hosseini and Mr Mahdi Emamjomeh for their support and encouragement. iv

ABSTRACT Rock bolts are used as temporary and permanent support systems in tunnelling and mining operations. In surface mining they are used for slope stability operations and in underground workings to develop roadway, sink shafts, and stoping operations. Rock bolting technology has developed rapidly over the past three decades due to a better understanding of load transfer mechanisms and advances made in the bolt system technology. Bolts are placed into discontinuous rock to prevent movement between the discontinuity planes, depending on the direction of installation and nature of the discontinuity surfaces. Rock bolting can increase the tension and shear properties of the rock mass. Nowadays, the application of rock bolts for ground reinforcement and stabilisation is worldwide, but its effectiveness depends on rock type, strata lithology, and encapsulation characteristics. Thus the bolt, rock interaction, particularly near the shear joints, and how a bolt reacts to surrounding conditions require continuous evaluation and research. Work provides an in depth study of the bolt, grout, concrete interaction during under axial and lateral loading. To better understand load transfer characterisation bolt shearing across joint and planes, this research programme consists of three parts. Accordingly, a series of experimental studies and field work was undertaken. A numerical technique was developed to obtain the stress and strain developed along the bolt and surrounding materials under axial and lateral loading. Finally, a field investigation programme was undertaken to obtain the load developed along different bolt profiles (another objective of this thesis). Bolt profiles were also investigated by laboratory studies. v

A double shearing system (DSS) was used to examine bolts shearing. Testing was undertaken in 20, 40, and 100 MPa strength concrete to simulate different rock strengths. Only three bolt types were used in axial loading tests and different thicknesses of resin were evaluated under axial and lateral loading. Tests subjected to lateral loading were undertaken in 0, 5, 10, 20, 50 and 80 kn pre-tension loads, which revealed that the strength of the concrete significantly affects the bolt - joint contribution. Also shear displacement was dramatically reduced when the strength of the concrete was increased. Pre-tension increases the shear resistance of the system. The profile of a rock bolt affects the shear performance and load transfer under axial and lateral loads. The 3-D FE code, ANSYS V. 9.1 was used. To investigate the load transfer and interaction between bolt, grout, and concrete under non-linear conditions, special element types for the materials and contact interfaces were introduced. The stress and strain built up along the materials under axial and lateral loads was examined. A laboratory study on shearing at the bolt, resin interface of fully grouted bolts was extended to field studies in Appin and Metropolitan Collieries in the Southern Coalfields of the Sydney Basin, NSW, Australia. Twelve instrumented bolts were installed at both mines. Both installation sites were in the heading of a retreating long wall mine. The field investigation revealed that the load transfer on a bolt is affected by horizontal in-situ stresses and profile of the bolt surface. It showed that bolt with higher ribs and wider spacing offered greater shear resistance at the bolt - resin interface, which agreed with the laboratory results. vi

TABLE OF CONTENTS TITLE AFFIRMATION..i LIST OF PUBLICATIONS...ii ACKNOWLEDGMENTS.....iv ABSTRACT. v LIST OF FIGURES.. xv LIST OF TABLES...xxviii LIST OF SYMBOLS AND ABBREVIATIONS..xxx CHAPTERS CHAPTER ONE 1 INTRODUCTION 1 1.1. GENERAL...1 1.2. KEY OBJECTIVE...4 1.3. METHODOLOGY...5 1.4. SCOPE...5 CHAPTER TWO 9 ROCK BOLT SYSTEM AND REVIEW OF BOLTS UNDER AXIAL LOADING 9 2.1. INTRODUCTION...9 2.2. HISTORICAL...9 2.3. ROOF BOLT PRACTICE AND APPLICATION...10 2.4. REINFORCEMENT MECHANISM...11 2.5. BOLT THEORIES...12 vii

2.6. TYPES OF ROCK BOLTS...14 2.7. LOAD TRANSFER IN ROCK BOLTS...19 2.8. SELECTION OF FULLY GROUTED BOLTS...22 2.8.1. Fully grouted bolt failure...23 2.8.2. Load transfer measurement...24 2.9. EFFECT OF BOLT IN A CONTINUUM MEDIUM...26 2.10. THE EFFECT OF BOLTS ON DISCONTINUITY...26 2.11. REVIEW OF FAILURE MECHANISM OF BOLT RESIN INTERFACE SUBJECTED TO AXIAL LOAD...28 2.11.1. Theoretical behaviour of a bolt under axial load...28 2.11.2. Experimental behaviour of a bolt under axial load...36 2.11.3. Bolt - grout - rock interface mechanism...40 2.11.4. Load transfer mechanism...45 2.12. SUMMARY...49 CHAPTER THREE REVIEW OF SHEAR BEHAVIOUR OF BOLTS AND MATERIAL PROPERTIES 3.1. INTRODUCTION...51 3.2. PAST RESEARCH...53 3.3. PRE-TENSION EFFECT IN FULLY GROUTED BOLTS...76 3.4. MECHANICAL PROPERTIES OF REINFORCING MATERIALS...78 3.4.1. Bolt types...78 3.4.2. Bolt strength tests...80 3.4.2.1. Tensile strength test...80 3.4.2.2. Three point load bending test...83 3.4.2.3. Direct shear test...84 3.4.3. Resin grout...85 3.4.4. Concrete...90 3.4.4.1. Uniaxial compressive strength...90 3.4.4.2. Concrete joint surface properties...91 3.5. SUMMARY...94 viii

CHAPTER FOUR FAILURE MECHANISM OF RESIN INTERFACES DUE TO AXIAL LOAD 4.1. INTRODUCTION...96 4.2. LOAD TRANSFER MECHANISM...96 4.3. BOND CHARACTERISTICS...98 4.4. PUSH AND PULL ENCAPSULATION TESTS...99 4.4.1. Push encapsulation test...101 4.4.2. Pull encapsulation test...103 4.5. DISCUSSION...104 4.5.1. Effect of bolt profile...107 4.5.2. Bolt yielding and necking...110 4.5.3. Effective shear stress at the bond interface...111 4.5.4. Bolt core behaviour subjected to axial loading...115 4.5.5. Effect of annulus...116 4.6. SUMMARY...117 CHAPTER FIVE DOUBLE SHEARING OF BOLTS ACROSS JOINTS 5.1. INTRODUCTION...119 5.2. EXPERIMENTAL PROCEDURE...120 5.2.1. Block casting...120 5.2.2. Bolt installation in concrete blocks...121 5.3. DOUBLE SHEAR BOX...122 5.4. TESTING...123 5.5. BOLT TYPES...125 5.6. RESULTS AND DISCUSSION...127 5.6.1. Shear load and shear displacement...127 5.6.1.1. Profile description...127 5.6.1.2. Shear loading for a limited displacement...129 5.6.1.3. Shear loading of bolt to ultimate failure...138 ix

5.6.2. Influence of shearing load on pre-tension load...147 5.6.3. Load transfer level in different profile...151 5.6.4. Double shearing of instrumented bolt...152 5.6.5. Medium (concrete and resin) reaction...157 5.6.6. Bolt contribution...160 5.7. SUMMARY...166 CHAPTER 6 ROLE OF BOLT ANNULUS THICKNESS ON BOLT SHEARING 6.1. INTRODUCTION...168 6.2. TEST METHOD...168 6.3. EXPERIMENTAL RESULTS AND DISCUSSION...169 6.3.1. Shear load/ shear displacement...170 6.3.2. Axial load built up...174 6.3.3. Failure mechanism of reinforced element...175 6.3.4. Effect of resin thickness on shear...180 6.4. NUMERICAL SIMULATION WITH DIFFERENT THICKNESS OF RESIN...182 6.5. RESIN ANNULUS EFFECT ON INDUCED STRESSES...184 6.5.1. Induced shear stress...185 6.5.2. Induced tensile stress...185 6.5.3. Induced compression stress...186 6.6. EFFECT OF CONCRETE MODULUS...187 6.7. EFFECT OF GROUT MODULUS...188 6.8. EFFECT OF BOLT MODULUS...189 6.9. SUMMARY...191 CHAPTER 7 NUMERICAL ANALYSES OF FULLY GROUTED ROCK BOLTS 7.1. INTRODUCTION...193 7. 2. FE IN ANSYS...193 x

7.3. A REVIEW OF NUMERICAL MODELLING IN ROCK BOLT...194 7.4. MATERIAL DESIGN MODEL...198 7.4.1. Modelling concrete and grout...201 7.4.2. Modelling the bolt...202 7.4.3. Contact interface model...203 7.4.4. Geometrical model...204 7.5. VERIFICATION OF THE MODEL...205 7.6. MODELLING BOLTS UNDER LATERAL LOADING...206 7.6.1. Bolt behaviour...207 7.6.1.1. Stresses developed along the bolt...207 7.6.1.2. Strain developed along the bolt...216 7.6.2. Concrete behaviour...221 7.6.2.1. Stress developed in concrete...221 7.6.2.2. Strain developed in concrete...223 7.6.3. Grout behaviour...226 7.6.3.1. Stress in grout...226 7.6.3.2. Strain in grout...229 7.6.4. Contact pressure...231 7.7. BOLT MODELLING UNDER AXIAL LOADING...233 7.7.1. Bolt behaviour...235 7.7.2. Grout behaviour...238 7.7.3. Modulus of elasticity effect...241 7.8. SUMMARY...244 CHAPTER 8 ANALYTICAL ASPECTS OF FULLY GROUTED BOLT 8.1. REACTION FORCES DURING SHEARING...246 8.2. STEEL BOLT BEHAVIOUR...248 8.2.1. Plastic theory...248 8.2.2. Basic equation for a grouted rock bolt subjected to lateral deformation250 8.3. Bolt joint contribution...254 8.4. REACTION FORCES...256 8.5. HINGE POINT LOCATION AND AXIAL LOADING...258 xi

8.5.1. Elastic behaviour...258 8.5.2. Plastic behaviour...261 8.6. HINGE POINT POSITION AND SHEAR DISPLACEMENT...265 8.7. SHEAR DISPLACEMENT AND BOLT MODULUS OF ELASTICITY..266 8.8. ANALYSIS OF A FULLY GROUTED ELASTIC BOLT IN PLASTIC ROCK MASS...268 8.9. SUMMARY...281 CHAPTER 9 FIELD INVESTIGATIONS 9.1. INTRODUCTION...282 9.2. SITE DESCRIPTION...282 9.2.1. Metropolitan Colliery...282 9.2.2. Appin Colliery...286 9.3. INSTRUMENTATION...289 9.3.1. Instrumented bolts...289 9.3.2. Intrinsically safe strain bridge monitor...291 9.4. FIELD MONITRING AND DATA PROCESSING...293 9.4.1. Metropolitan Colliery...293 9.4.2. Appin Colliery...299 9.4.3. Comparison of load transfer in bolt type T1 and bolt type T3...302 9.5. SUMMARRY...304 CHAPTER 10 CONCLUSIONS AND RECOMMENDATIONS 10.1. EXPERIMENTAL INVESTIGATIONS...307 10.1.1. Axial loading conditions...307 10.1.2. Lateral loading conditions...308 10.2. NUMERICAL AND ANALYTICAL STUDIES...309 10.3. FIELD INVESTIGATIONS...311 10.4. SUGGESTIONS FOR FURTHER RESEARCH...311 xii

REFRENCES... 313 APPENDIX A Short encapsulation pull and push test data..a.1 APPENDIX B Double shear results in different conditions..b.1 APPENDIX C Double shear results in different resin thickness...c.1 APPENDIX D Numerical techniques....d.1 APPENDIX E Load distribution along the bolt....e.1 APPENDIX F Numerical program for bolt axial behaviour.....f.1 xiii

List of Figures Figure 1.1. Structure of Chapters.6 Figure 2.1. Usage of rock bolts in the world...11 Figure 2.2. Continuous mechanically coupled rock bolt...20 Figure 2.3. Load transfer in fully grouted rock bolts...21 Figure 2.4. Rate of load transfer along the fully grouted rock bolts...22 Figure 2.5. The mechanism of load transfer...24 Figure 2.6. Results of load deformation in different bolts (Stillborg 1994)...25 Figure 2.7. Bolt installation to the joint a: perpendicular, b: incline (after Obert and Duvall 1967)...27 Figure 2.8. Stress situation in a grouted anchor (after Farmer, 1975)...30 Figure 2.9. Theoretical stress distribution along a resin anchor in a rigid hole with thin resin annulus (after Farmer 1975)...31 Figure 2.10. Load displacement, strain distribution, and computed shear stress distribution curves in concrete, a) strain distribution at the specified anchor load, b) theoretical shear stress distribution curves (after Farmer 1975)...31 Figure 2.11. Stress distribution model for grouted bolt (after Yu and Xian, 1983)...34 Figure 2.12. Stress Component in a small section of a bolt (after Stillberg & Li, 1999)...34 Figure 2.13. Shear stress along a fully coupled rock bolt subjected to an axial load before de-coupling...35 Figure 2.14. Distribution of shear stress along a fully grouted rock bolt subjected to an axial load in coupled rock bolt...36 Figure 2.15. Variables used in a closed form solution (after Serbousek and Singer 1987)...38 Figure 2.16. Schematic illustration of different conical lugged bolts: (a) Single, (b) Double and (c) Triple conical lugged bolt...39 Figure 2.17. Shear stress versus shear displacement in bolt /grout interface at different bolt diameter (after Aydan 1989)...42 xiv

Figure 2.18. Dilation behaviour of joint plane a) two smooth plane, b) bolt and resin interface...43 Figure 2.19. Pull test gear arrangement (after Singer 1990)...44 Figure 2.20. Comparison of load distribution along the bolt length...44 Figure 2.21. Schematic diagram reflecting the geometry of a rough bolt (after Yazici and Kaiser, 1992)...46 Figure 2.22. Load/displacement curves for rebar with various amounts of bar deformation removed (after Fabjanczyk and et al, 1992)...47 Figure 3.1. Stability issues in rock mass reinforced by fully grouted bolts...52 Figure 3.2. Shear test arrangement in (a) and (b) probable load generation (after Dulasck 1972)...54 Figure 3.3. Components of shear resistance by a bolt (after Bjurstrom, 1974)...56 Figure 3.4. (a) Block splitting in one side of shear joint (b) non equilibrium situation in vicinity of shear joint...57 Figure 3.5. (a) Finite element mesh and (b) deviatoric of stress distribution across the joint (Afridi and et al. 2001)...57 Figure 3.6. Arrangement for bolt shear testing (after Hass, 1981)...59 Figure 3.7. General deformation patterns for a dowel in shear...60 Figure 3.8. Shear test machine used by Schubert (after Schubert1984)...63 Figure 3.9. Relationship between shear stress and shear displacement (after Yoshinaka 1987)...63 Figure 3.10. Direct shear test device (after Egger and Zabuski 1991)...65 Figure 3.11. Bolt grout behaviour (after Holmberge 1991)...66 Figure 3.12. A grouted rock bolt subjected to lateral force...68 Figure 3.13. Ferrero s shear test machine...69 Figure 3.14. Resistance mechanism of a reinforced rock joint (after Ferrero 1995)..69 Figure 3.15. Forces acting on the failure mechanism (after Ferrero 1995)...70 Figure 3.16. Force components and deformation of a bolt, a) in elastic zone, and b) in plastic zone (after Pellet and Eager 1995)...72 xv

Figure 3.17. Evolution of shear and axial forces in a bolt, a) in elastic zone, and b) in plastic zone (after Pellet and Egger, 1995)...72 Figure 3.18. Joint displacement as a function of angle for different UCS value (after Pellet 1994)...74 Figure 3.19. Shear block test assembly (after Goris and et al. 1996)...75 Figure 3.20. Different Bolt Types used for axial and shear behaviour tests...79 Figure 3.21. Profiles specification...79 Figure 3.22. Bolt clamped in Instron Universal testing Machine...81 Figure 3.23. Stretching of the bolts after tensile test...82 Figure 3.24. Load- deflection curve at tensile test in various bolts 83 Figure 3.25. Load- deflection curve at tensile test of Bolt Type T5 and T6... 83 Figure 3.26. Load- deflection curve at tensile test in cable bolt.83 Figure 3.27. Load- deflection curve at tensile test of Bolt Type T4...83 Figure 3.28. Three point load bending test set up...84 Figure 3.29. Load- displacement behaviour of 3PLBT..84 Figure 3.30. direct shear test trend in Bolt Types T1 and T3 85 Figure 3.31. Typical fracture plane and fracture angle for compression test samples87 Figure 3.32. Compression test set up..88 Figure 3.33. Stress strain curve for resin...88 Figure 3.34. Load versus displacement.....89 Figure 3.35. Double shear test set up (a) shear box set up (b) induced loads 90 Figure 3.36. Concrete sample: (a) concrete under the test (b) concrete after 30 days91 Figure 3.37. Variation of peak shear stress versus different normal stress in shear joint plane in a: 20 MPa and b: 40 MPa concrete..93 Figure 3.38. Shear load versus shear displacement in joint plane in 40 MPa concrete... 93 Figure 4.1. Sketch of real bolt profile specifications and interfaces...98 xvi

Figure 4.2. (a) Resin-bolt load transfer under various confining pressures (b) resin bolt separation after post encapsulation...99 Figure 4.3. (a) The actual push test configuration (b) the shematic of the test...101 Figure 4.4. Preparing the bolt resin samples...102 Figure 4.5. Post-test sheared Bolt Type T2 out of steel cylinder in push test...102 Figure 4.6. Pull test arrangement...103 Figure 4.7. Post-test sheared bolt out of steel cylinder...104 Figure 4.8. Shear load as a function of displacement in pull test...106 Figure 4.9. Shear load as a function of displacement in push test...106 Figure 4.10. General trend of push and pull test view...107 Figure 4.11. The effect of Rib spacing on shear load...109 Figure 4.12. Shear load versus shear displacement in smooth bolt...110 Figure 4.13. De-bonding at pull test...111 Figure 4.14. Shear stress versus bond displacement in push test...113 Figure 4.15. Shear stress versus bond displacement in pull test...113 Figure 4.16. Annulus thickness effect..116 Figure 5.1. Bolt bending behaviour (after Indraratna et al. 2000)...119 Figure 5.2. Laboratory and numerical model...120 Figure 5.3. Hole reaming for hole rifling...121 Figure 5.4. An assembled bolt fitted with load cells on both ends of the bolt...122 Figure 5.5. Schematic of post failed assembled shear box (a), and a set up of the high strength capacity machine -Avery machine (b)...124 Figure 5.6. The set up of the Instron machine with load cell connection...124 Figure 5.7. Different bolt types...125 Figure 5.8. Typical shear load displacement profile stages of the sheared bolt...128 xvii

Figure 5.9 (a-f). Shear load and vertical displacement profiles of Bolts Types T1, T2 and T3 in both 20 and 40 MPa concrete...133 Figure 5.10 (a-f). Shear load versus vertical shear displacement profiles of various bolts in 20 and 40 MPa concrete at different pretension load...134 Figure 5.11. Shear yield load values in different concrete strength of various bolt types and various pretension loads...135 Figure 5.12. Bolt slippage along the bolt -grout interface in case of non-pre-tension loading and non- plate...137 Figure 5.13. Axial fracture along the concrete and grout breaking off in the tensile zone in Bolt Type T1 in 40 MPa concrete with 80 kn pre-tension loading...138 Figure 5.14. Shear load versus shear displacement in 0, 5 and 10 kn pretension load in Bolt Types T5 and T6 in 40 MPa concrete...142 Figure 5.15. Bolt failure view in different pretensioning...142 Figure 5.16. (a) Relationship between failure load and maximum tensile strength on one side of the shear joint on Bolt Type T5, (b) bolt failure angle...143 Figure 5.17. Shear load versus shear displacement in 100 MPa concrete and different pre-tension loading in Bolt Type T1...143 Figure 5.18. Excessive bolt necking in 100 MPa concrete, 80 kn pretension load.144 Figure 5.19. Bolt/ joint concrete interaction at shear joint in 100 MPa concrete with 80 kn pre-tension load...144 Figure 5.20. Bolt imprint on resin in 100 MPa concrete at 50 and 80 kn pre-tension loads...145 Figure 5.21. The ratio of axial load developed along the bolt over ultimate tensile strength of the bolt versus shear displacement in concrete 100 MPa with 80 kn pretension load...147 Figure 5.22. Shear load versus load cell readings on tensile load applied on a bolt installed in a 20 MPa concrete...148 Figure 5.23(a-f). Shear load and pretension loads (load cell readings) for various bolts with an initial pre-tension load of 20, 50 and 80 kn...149 Figure 5.24. End crushing of the concrete in high pre-tension load...150 Figure 5.25. Axial load developed along the bolt versus shear displacement in Bolt Type T2 in 40 MPa concrete...150 xviii

Figure 5.26. Effect of pre-tension load, bolt profile and concrete strength on the bolt resistance...151 Figure 5.27. Schematic diagram of the strain gauges locations in the reinforcing element (a) without pretension load and (b) 20 kn pre-tension load...153 Figure 5.28. Shear load versus strain measurements in non-pretension load...155 Figure 5.29. Bolt surface with strain gauges installed...156 Figure 5.30. Strain rate along the bolt, as measured on the bolt, in zero pretension load...156 Figure 5.31. Shear load versus strain gauge measurements along the bolt in 20 kn of pre-tension...156 Figure 5.32. The variation of the strain gauge measurements along the bolt at 20 kn pre-tension load...157 Figure 5.33. Axial fracture developed along the bolt through the 20 MPa concrete159 Figure 5.34. The created gap in plastic stage...160 Figure 5.35. Effect of concrete strength on the factor of movement...163 Figure 5.36. Expected cumulative results versus observed cumulative results...165 Figure 5.37. Bolt contribution in Bolt Type T5 and T6 166 Figure 6.1. Shear load as function of displacement in different resin thickness...170 Figure 6.2. Effect of resin thickness on shear displacement...171 Figure 6.3. The effect of resin thickness on shear yield load...171 Figure 6.4. Shear load and shear displacement in concrete 20 and 100 MPa and 20 kn pretension load and different resin thickness in Bolt Type T1...172 Figure 6.5. Gap creation between bolt grout at high resin thickness in concrete 20 MPa with 20 kn preload (5 mm thick)...173 Figure 6.6. Bolt resin bending at high resin thickness in concrete 40 MPa with 20 kn preload (5 mm thick)...173 Figure 6.7. Shear load and axial load build up along the bolt in concrete 20 MPa and 20 kn pretension load and thin resin thickness in bolt Type T1 (25mm)...174 Figure 6.8. Shear load versus axial load developed along the bolt in different thicknesses of resin in 20 MPa concrete...175 xix

Figure 6.9. Axial load versus shear displacement in bolt T1 and 20 kn pre-load in 27 mm diameter hole surrounded by 20 MPa of concrete...176 Figure 6.10. Axial stress versus shear displacement in Bolt Type T1 in 20 kn preload in 36 mm diameter hole surrounded by 20 MPa of concrete...177 Figure 6.11. A comparison of axial load induced along the bolt in different thicknesses of resin thickness in 20 MPa strength (axial resistance factor is equal to axial load over ultimate tensile strength)...178 Figure 6.12. Side profile of failed Bolt Type T1 surrounded by 20 MPa of concrete and a 36 mm diameter hole under 20 kn of pre-tension load b) typical end profile of a failed reinforcing element...178 Figure 6.13. The effect of hole diameter versus stiffness...180 Figure 6.14. Effect of hole diameter and resin thickness on shear displacement in numerical design...183 Figure 6.15. Effect of resin thickness and concrete strength on shear displacement in numerical design in un-pretension load...183 Figure 6.16. Induced shear stress versus concrete modulus of elasticity in different annulus size (grout modulus is considered 12 GPa)...185 Figure 6.17. Induced tensile stress versus grout modulus of elasticity in soft concrete (20 GPa)...186 Figure 6.18. Induced compression stress versus concrete modulus of elasticity...187 Figure 6.19. Shear displacement versus concrete modulus of elasticity in different resin thickness, (grout modulus is 12 GPa)...188 Figure 6.20. Shear displacement versus grout modulus of elasticity in different resin thickness, concrete modulus is 20 GPa...189 Figure 6.21. Shear displacement as a function of bolt modulus variations in different strength rocks...190 Figure 7.1. FE Simulation of bolted rock mass (after Hollingshead, 1971)...196 Figure 7.2. Three-Dimensional rock bolt element (after John and Dillen, 1983)...196 Figure 7.3. Bolt-Rock interaction model (after Peng and Guo, 1988)...197 Figure 7.4. The process of FE simulation (Dof = degrees of freedom)...200 Figure 7.5. (a) 3D concrete Solid 65 (b) Concrete mesh...201 xx

Figure 7.6. Finite element mesh for grout...202 Figure 7.7. Finite element mesh for bolt...203 Figure 7.8. Geometry of the model and mesh generation...205 Figure 7.9. Load-deflection in 80 kn pretension bolt load and 40 MPa concrete...206 Figure 7.10. Numerical model (s = symmetric planes, c = compression zone, T = tension zone...208 Figure 7.11. Bolt displacement in 20 MPa, without Pre-tension...209 Figure 7.12. Shear displacement as a function of bolt length sections in 20 MPa concrete...210 Figure 7.13. Bolt deflection at the moving side and hinge point versus loading process, in 40 MPa concrete without pre-tension load...210 Figure 7.14. Stress built up along the bolt axis in 20 MPa concrete without pretension...211 Figure 7.15. Trend of stress built up along the bolt axis 20 MPa concrete with 80 kn pre-tension...212 Figure 7.16. Von Mises stress trend in 20 MPa concrete without pre-tension...213 Figure 7.17. Shear stress contour in the concrete 20 MPa without pre-tension...213 Figure 7.18. The rate of shear stress along the bolt axis in concrete 20 MPa without pre-tension...214 Figure 7.19. The rate of shear stress along the bolt axis in concrete 20 MPa without pre-tension in one side of the joint plane...215 Figure 7.20. Shear stress trend in bolt joint intersection in concrete 20 MPa at post failure region without pre-tension load...215 Figure 7.21. Deformed bolt shape in post failure region in 20 MPa concrete...216 Figure 7.22. Plastic strain contour along the bolt axis in concrete 20 MPa without pre-tension...217 Figure 7.23. Strain trend along the bolt axis in concrete 20 MPa without pre-tension in upper fibre of the bolt...217 Figure 7.24. Yield strain trend as a function of time stepping concrete 20 MPa in 20 kn pre-tension load...218 xxi

Figure 7.25. Tension and pressure strain along the bolt in 20 MPa concrete and 20 kn pre-tension...219 Figure 7.26. Von Mises strain trend along the bolt axis in concrete 40 MPa and 80 kn pre-tension...219 Figure 7.27. Von Mises strain along the bolt in concrete 20 MPa concrete without pre-tension...220 Figure 7.28. Von Mises strain trend in concrete 20 MPa without pre-tension in upper fibre of the bolt...220 Figure 7.29. Concrete displacement in non-pretension condition in 20 MPa...221 Figure 7.30.Yield stress induced in 20 MPa without pre-tension condition...222 Figure 7.31. Induced stress and displacement trend in 20 MPa concrete without pretension...223 Figure 7.32. Strain contours in 20 MPa concrete without pre-tension...224 Figure 7.33. Induced strain in concrete 20 MPa in grout and concrete versus loading without a pre-tension and 27 mm diameter hole...224 Figure 7.34. Concrete displacement versus loading time in concrete (a) 20 and (b) 40 MPa without pre-tension load...225 Figure 7.35. Induced strain rate along the contact interface in 40 MPa concrete and without pre-tension....225 Figure 7.36. Induced strain in concrete and bolt as a function of loading steps in 20 MPa concrete with 80 kn pre-tension...226 Figure 7.37. Maximum induced stress contours in grout layer without pre-tension and 20 MPa...227 Figure 7.38. Gap formation in post failure region in 20 MPa concrete in the Numerical simulation...228 Figure 7.39. Gap formation in post failure region in 20 MPa concrete in the laboratory test...228 Figure 7.40. Grout displacement in different location along the bolt axis in 40 MPa concrete...229 Figure 7.41. The rate of induced strain along the grout layer without pre-tension in an axial direction...230 xxii

Figure 7.42. The grout displacement as a function of plastic strain generated in bolt, joint intersection through the grout without pre-tension...230 Figure 7.43. The rate of contact pressure changes between (a) grout - concrete interface (b) bolt - grout interface in 20 MPa concrete without pre-tension...231 Figure 7.44. Contact pressure at the (a) bolt - grout interface (b) concrete - grout interface in 20MPa concrete in high resin thickness (36mm hole diameter) in 80kN pretension load...232 Figure 7.45. Shear load versus bolt-grout contact pressure at 36 mm hole and 20 MPa concrete with 80kN pre-tension load...233 Figure 7.46. Finite element mesh: a quarter of the model...234 Figure 7.47. The bolt movement in pulling test...234 Figure 7.48. Rate of the bolt displacement in pull test...235 Figure 7.49. Bolt displacement contour in Bolt Type T1 in case of push test...236 Figure 7.50. Induced strain along the bolt profiles in pull test...236 Figure 7.51. Shear strain in bolt ribs in push test...237 Figure 7.52. Von Mises Stress and shear stress along the bolt axis...238 Figure 7.53. Shear stress contours along the grout interface...240 Figure 7.54. The effect of grout modulus on shear displacement in push test...242 Figure 7.55. Effect of grout modulus on shear displacement in pull test...242 Figure 7.56. Shear displacement as a function of grout modulus of elasticity in case of push and pull test...243 Figure 8.1. Assembled model (concrete, grout and steel bolt)...247 Figure 8.2. Load generation along the bolt during shearing...247 Figure 8.3. Stress strain relationship for bolt type T1...248 Figure 8.4. Elastic plastic stress sequence in bending...249 Figure 8.5. Deformed shape, shear force, bending moment and shear displacement diagrams...251 Figure 8.6. Applied loads on joint intersection...254 xxiii

Figure 8.7. Reaction forces in bolt loaded laterally...258 Figure 8.8. Hinge point distance versus axial force...260 Figure 8.9. Bolt diameter versus hinge point distance in different rock strength...261 Figure 8.10. The relationship between axial load and hinge point distance in different rock strength in plastic situation...263 Figure 8.11. The relationship between the axial load and hinge point distance in both elastic and plastic situation...263 Figure 8.12. Hinge point position in different concrete strength...264 Figure 8.13. Relationship between hinge point position and axial deformation...264 Figure 8.14. Hinge point location as a function of shear displacement in elastic region...265 Figure 8.15. Comparison of the numerical and analytical results in 20 MPa...268 Figure 8.16. Notation for numerical formulation...272 Figure 8.17. Axial load along the bolt versus bolt length, with 25 MPa initial stress and 15 GPa modulus of surrounding rock, no face plate...274 Figure 8.18. Normalised displacement versus bolt length for a bolt without a plate with 25 MPa initial stress and 15 GPa modulus of surrounding rock...274 Figure 8.19. Normalised displacement versus bolt length for a bolt without a plate, with 25 MPa initial stress and 15 GPa modulus of surrounding rock at different k values...275 Figure 8.20. Normalised displacement versus bolt length for a bolt without a plate, with 15 MPa initial stress and 15 GPa modulus of surrounding rock at different k values...275 Figure 8.21. Load developed along the bolt versus bolt length with no face plate with 15 MPa initial stress and 25 GPa modulus of surrounding rock at different k values...276 Figure 8.22. Load developed along the bolt versus bolt length in case of a bolt without a plate, with 15 GPa modulus of surrounding rock at different initial stresses...276 Figure 8.23. Load developed along the bolt versus bolt length in case of a bolt without a plate, with 25 MPa initial stress and different modulus of surrounding rock at k=10...277 xxiv

Figure 8.24. Load developed along the bolt versus bolt length in case of a bolt without plate, with 25 MPa initial stress and different modulus of surrounding rock at k=10, L=10 m...277 Figure 8.25. Load developed along the bolt versus bolt length in case of using end plate with 25 MPa initial stress and different k, at E r = 5GPa...278 Figure 8.26. Normalised displacement versus bolt length in case of using end plate with 25 MPa initial stress and different k, at E r = 5GPa...278 Figure 8.27. Axial load versus bolt length in case of using end plate with 25 MPa initial stress and different rock modulus and bolt length, k=10...279 Figure 8.28. Normalised displacement versus bolt length in case of using end plate with 25 MPa initial stress and different rock modulus and bolt length, k=10...279 Figure 8.29. Axial load versus bolt length in case of using end plate in different initial stress with 5 GPa rock modulus, k=10...280 Figure 8.30. Axial load versus bolt length in case of using end plate in different plastic zone radius with 5 GPa rock modulus, k=10...280 Figure 9.1. Geographical location of (a) Metropolitan and (b) Appin Colliery...283 Figure 9.2. Modelled geological section and strength profiles (SCT report 2002...284 Figure 9.3.Detailed layout of the panel under investigation indicating instrumentation site at Metropolitan Colliery...285 Figure 9.4. Photograph of the site with installed bolts in Metropolitan Colliery...285 Figure 9.5. Detail site plane of the instrumented bolts at Metropolitan Colliery...286 Figure 9.6. Status of the horizontal stress in Appin Colliery...287 Figure 9.7.Detailed layout of the panel under investigation indicating instrumentation site at Appin Colliery (M= main gate, T = bolt type)...288 Figure 9.8. Photograph of the site with installed bolts in Appin Colliery...289 Figure 9.9. Bolt segment showing channels...290 Figure 9.10. Strain gauge and bolt layout...290 Figure 9.11. A section of an instrumented bolt showing the strain gauge and wirings through the silicon gel...291 Figure 9.12. A general view of the SBM, while taking readings in underground...292 xxv

Figure 9.13. Load transferred on the bolt Type T1 installed at the travelling road in, Metropolitan Colliery...294 Figure 9.14. Load transferred on the bolt Type T3 installed at the travelling road in, Metropolitan Colliery...295 Figure 9.15. Shear stress developed at the bolt/resin interface of the Bolt Type T1, in Metropolitan Colliery...297 Figure 9.16. Shear stress developed at the bolt/resin interface of the Bolt Type T3, in Metropolitan Colliery...298 Figure 9.17. Load transferred on the Bolt Type T1, (a) middle of the belt road (b) close to the belt in Appin Colliery...299 Figure 9.18. Load transferred on the Bolt Type T3, (a) middle of the road (b) rib side in Appin Colliery...300 Figure 9.19. Shear stress developed at the bolt/resin interface of the Bolt Type T1, in Appin Colliery (a) middle of the road (b) belt side...301 Figure 9.20. Shear stress developed at the bolt/resin interface of the Bolt Type T3, in Appin Colliery (a) rib side (b) middle of the road...302 Figure 9.21. Load transferred on the Bolt Type T1 and T3, installed at the right side of the traveling road, Metropolitan Colliery...303 Figure 9.22. Load transferred on the Bolt Type T1 and T3, installed at the middle side of the belt road, Appin Colliery...304 Figure 10.1. Large scale of double shear box... 312 xxvi

LIST OF TABLES Table 2.1. Table 2.2. Table 2.3. Table 3.1. Table 3.2. Table 3.3. Bolt theories......13 Bolt types and descriptions...15 Bolt accessories........18 A brief comparison of the used methods in bolt shear behaviour...77 Physical specifications of different bolt types......80 Bolt tensile strength.........82 Table 3.4. Specification of bolt shear test......... 85 Table 3.5. Table 3.6. Table 3.7. Table 4.1. Table 4.2. Table 4.3. Table 4.4. Table 5.1. Table 5.2. Summary of the results obtained from UCS test...87 Double shear test specifications....89 Concrete joint properties... 93 Grout and steel properties........ 102 The load transfer laboratory results of the bolts in both pull and push tests..105 Comparison of the laboratory results in pull and push tests....114 Axial and lateral strains along the bolt in pull and push tests..115 Experimental schedule indicating the number of samples tested per bolt in 20 MPa concrete.....126 Experimental schedule indicating the number of samples tested per bolts in 40 and 100 MPa concrete.....127 Table 5.3. Experimental schedule indicating the number of samples tested per boltst5 and T6 (low strength steel in 40 MPa concrete..127. Table 5.4. Yield point shear load values for different bolts under different environment....131 Table 5.5. Yield point shear load values for bolt type T1 under different environment..... 132 Table 5.6. Test results at bolt Types T5 and T6 surrounded by 40 MPa concrete....140 xxvii

Table 5.7. Table 5.8. Bolt Type T1 in 100 MPa concrete..141 Joint confining specification......162 Table 6.1. The results of bolt tested in Type T1-20 MPa strength with 20 kn pretension load.....169 Table 6.2. The results of shear test in different resin thickness and concrete strength.....169 Table 6.3. Table 7.1. Concrete strength effect on shear displacement reduction in different resin thickness..........184 Summary of created models......207 xxviii

LIST OF SYMBOLS AND ABBREVIATIONS SYMBOLS σ p Horizontal stress; σ b β ϕ τ x ξ x Bolt axial stress Angle between the normal to the fracture plane and the horizontal plane Friction angle of the fracture Shear stress in resin annulus Extension in the bolt a x R Gg k l Radius of bolt Distance along the length of bolt starting at free end of grout Radius of the borehole Shear modulus of grout Long term shear deformation modulus of rock w (x) Expression for bolt displacement u (x) Bolt displacement due to strain u P r o A b D b σ b σ σ 0 α y d p a E b l Neutral point displacement Radial distance to the neutral point Tunnel radius Bolt cross-section area Bolt diameter Applied stress Stress in the bolt at a distance y d Stress at the point of applied force Decay coefficient 1/in which depends on the stiffness of the system Distance along the bolt from the applied load Load applied at the bolthead Modulus of the bolt The deflection at the head of the bolt xxix

i Apparent dilation angle β Reduction coefficient of dilation angle 0 σ lim Limiting stress ϕ 0 P p l a s k,t T σ c T re A j σ n p u t t y θ ϕ b t r Q α j F Q oe Friction angle between the bolt and grout Ultimate pull out load Anchorage length Slip between anchorage and grout Coefficients which depend on the type of anchor, grout and stages of shear. Shear force carried by bolt Uniaxial compressive strength of rock The reinforcement effect in shear resistance due to bolting Joint area Normal stress on joint The bearing capacity of the grout or rock Axial bolt load in the position of the plastic moment, Axial load corresponding to the yield strength The angle between the normal vector to the joint and the bolt, The basic joint friction angle Load induced in the bolt Force due to dowel effect Angle between the joint and the dowel axis Global reinforced joint resistance Shear force acting at point O at the yield stress of the bolt N oe Axial force acting at shear plane at the yield stress of the bolt σ el Yield stress of the bolt Q of Shear force acting at shear plane at failure of the bolt N of Axial force acting at shear plane at failure of the bolt σ ec Axial failure stress of the bolt l e Hinge length xxx

E c ρ Concrete Modulus of elasticity Concrete density f cm Mean value of the concrete compressive strength at the relevant age τ p Peak shear stress, T max The peak shear load at bolt-grout interface a r D s Height of rib Rib spacing U The shear displacement at each step of loading σ aij Change in axial stress between two adjacent gauges ε ai Axial strain at gauge 1 ε aj Axial strain at gauge 2 τ y Grout shear strength τ res Residual bond strength µ Friction coefficient between bolt-grout interface N c Confining load c n Cohesion between block joints Normal force f (t) Bolt contribution T v T t Shear load Joint contribution F max Maximum tensile strength of the bolt f (u) Dimensionless factor in terms of shear displacement, u b T b f ty u y D h Pr Shear displacement Yield point at shear load- displacement curve (bolt contribution) Pretension load Joint movement, which is usually twice bolt deflection Hole diameter Pretension load xxxi

E g I K s t a σ t Modulus of elasticity of the grout Bolt moment of inertia Bolt stiffness Resin thickness Tensile stress in bolt γ γ r γ max τ r τ max Shear strain at any point in the interface Shear strain at residual shear strength Shear strain at peak shear strength Residual shear strength of the interface Peak shear strength of interface T ab Actual bond stress in the grout T y Yield stress of the grout in shear f A y K m E m Axial force in the bolt Contact interface area Deflection of the bolt Stiffness of subgrade reaction Modulus of subgrade N cf Normal force at yield limit N p Q p Normal force at failure Shear force at failure M D Bending moment at yield limit M p Bending moment at plastic limit N D Axial force in hinge point σ f Failure stress at bolt material Q e β j p r K i p u Shear force acting at point C in elastic limit Joint slope Pretensioning Interface load transfer factor Support reaction xxxii

K m u y Lateral stiffness, Lateral deformation S Section modulus. σ max Normal stress acting on the bolt E i Q cf Modulus of elasticity of intact subgrade Shear force L cp Reaction length F x Shear load due to bond per unit length in elastic behaviour K u r Shear stiffness of interfaces (N/mm^2) Rock displacement along the bolt u ro Total deformation of the excavation wall ν Po r e E as V d G τ Poison ration of rock mass In situ stress The boundary between the zone of plastic and elastic The mean actual strain measured by an active gauge, The change in SBM reading, and The gauge factor of the strain gauge Average shear stress at the bolt-resin interface, F 1 Axial force acting in the bolt at strain gauge position 1 F 2 Axial force acting in the bolt at strain gauge position 2 l Distance between strain gauge position 1 and strain gauge position 2. ABREVIATIONS JRC Joint roughness coefficient JCS Joint compressive strength xxxiii