Comparative Analysis Between Fuzzy and PID Control for Load Frequency Controlled Power

Similar documents
SPEED CONTROLLER DESIGN FOR STEAM TURBINE

Simulation and Analysis of Cascaded PID Controller Design for Boiler Pressure Control System

Design of an Intelligent Pressure Control System Based on the Fuzzy Self-tuning PID Controller

Governor with dynamics: Gg(s)= 1 Turbine with dynamics: Gt(s) = 1 Load and machine with dynamics: Gp(s) = 1

1. Governor with dynamics: Gg(s)= 1 2. Turbine with dynamics: Gt(s) = 1 3. Load and machine with dynamics: Gp(s) = 1

Intelligent Fuzzy-PID Hybrid Control for Temperature of NH3 in Atomization Furnace

International Journal of Scientific & Engineering Research, Volume 6, Issue 6, June-2015 ISSN

TWO AREA CONTROL OF AGC USING PI & PID CONTROL BY FUZZY LOGIC

COMPARISON OF TUNING METHODS OF PID CONTROLLER USING VARIOUS TUNING TECHNIQUES WITH GENETIC ALGORITHM

Temperature Control in HVAC Application using PID and Self-Tuning Adaptive Controller

Open Access Design of Diesel Engine Adaptive Active Disturbance Rejection Speed Controller

Fuzzy Adapting PID Based Boiler Drum Water Level Controller

Position Control of DC Motor by Compensating Strategies

CHAPTER 1 INTRODUCTION

Load Frequency and Voltage Control of Two Area Interconnected Power System using PID Controller. Kavita Goswami 1 and Lata Mishra 2

AUTOMATIC GENERATION CONTROL OF REHEAT THERMAL GENERATING UNIT THROUGH CONVENTIONAL AND INTELLIGENT TECHNIQUE

Experiment 9. PID Controller

A Novel PSS Design for Single Machine Infinite Bus System Based on Artificial Bee Colony

-binary sensors and actuators (such as an on/off controller) are generally more reliable and less expensive

ScienceDirect. Optimization of Fuzzy Controller Parameters for the Temperature Control of Superheated Steam

AGC in Five Area Interconnected Power System of Thermal Generating Unit Through Fuzzy Controller

Load Frequency Control of Multi-Area Power Systems Using PI, PID, and Fuzzy Logic Controlling Techniques

Inverse Dynamic Neuro-Controller for Superheater Steam Temperature Control of a Large-Scale Ultra-Supercritical (USC) Boiler Unit

Comparative Analysis of Air Conditioning System Using PID and Neural Network Controller

CHAPTER 4 PID CONTROLLER BASED SPEED CONTROL OF THREE PHASE INDUCTION MOTOR

Design Of PID Controller In Automatic Voltage Regulator (AVR) System Using PSO Technique

PID Tuning Using Genetic Algorithm For DC Motor Positional Control System

Some Tuning Methods of PID Controller For Different Processes

Load Frequency Control of Three Different Area Interconnected Power Station using Pi Controller

Simulation Analysis of Control System in an Innovative Magnetically-Saturated Controllable Reactor

Resistance Furnace Temperature Control System Based on OPC and MATLAB

DC Motor Speed Control: A Case between PID Controller and Fuzzy Logic Controller

CONTROLLER TUNING FOR NONLINEAR HOPPER PROCESS TANK A REAL TIME ANALYSIS

Design of Joint Controller for Welding Robot and Parameter Optimization

CHAPTER 4 LOAD FREQUENCY CONTROL OF INTERCONNECTED HYDRO-THERMAL SYSTEM

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Design and Development of an Optimized Fuzzy Proportional-Integral-Derivative Controller using Genetic Algorithm

Design of GA Tuned Two-degree Freedom of PID Controller for an Interconnected Three Area Automatic Generation Control System

Load Frequency Control of Multi Area Hybrid Power System Using Intelligent Controller Based on Fuzzy Logic

PID Controller Design Based on Radial Basis Function Neural Networks for the Steam Generator Level Control

CHBE320 LECTURE XI CONTROLLER DESIGN AND PID CONTOLLER TUNING. Professor Dae Ryook Yang

IMPROVING EFFICIENCY OF ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS BY USING PREDICTIVE CONTROL METHOD AND FUZZY LOGIC CONTROL METHOD

TUNING OF PID CONTROLLERS USING PARTICLE SWARM OPTIMIZATION

Improvement in Dynamic Response of Interconnected Hydrothermal System Using Fuzzy Controller

Relay Feedback based PID Controller for Nonlinear Process

Design and Implementation of Self-Tuning Fuzzy-PID Controller for Process Liquid Level Control

Artificial Intelligent and meta-heuristic Control Based DFIG model Considered Load Frequency Control for Multi-Area Power System

Fuzzy Logic Controller on DC/DC Boost Converter

Simulation of Synchronous Machine in Stability Study for Power System: Garri Station as a Case Study

CONTROLLER DESIGN ON ARX MODEL OF ELECTRO-HYDRAULIC ACTUATOR

Automatic Generation control of interconnected hydrothermal power plant Using classical and soft computing Technique

Internal Model Control of Overheating Temperature Based on OVATION System

EXPERIMENTAL INVESTIGATION OF THE ROLE OF STABILIZERS IN THE ENHANCEMENT OF AUTOMATIC VOLTAGE REGULATORS PERFORMANCE

Design of Different Controller for Cruise Control System

Load Frequency Control of Interconnected Hydro-Thermal Power System Using Fuzzy and Conventional PI Controller

Abstract: PWM Inverters need an internal current feedback loop to maintain desired

Review Paper on Comparison of various PID Controllers Tuning Methodologies for Heat Exchanger Model

6545(Print), ISSN (Online) Volume 4, Issue 1, January- February (2013), IAEME & TECHNOLOGY (IJEET)

ANNA UNIVERSITY :: CHENNAI MODEL QUESTION PAPER(V-SEMESTER) B.E. ELECTRONICS AND COMMUNICATION ENGINEERING EC334 - CONTROL SYSTEMS

Load frequency control in Single area with traditional Ziegler-Nichols PID Tuning controller

Logic Developer Process Edition Function Blocks

The Effect of Fuzzy Logic Controller on Power System Stability; a Comparison between Fuzzy Logic Gain Scheduling PID and Conventional PID Controller

A new fuzzy self-tuning PD load frequency controller for micro-hydropower system

INTEGRATED PID BASED INTELLIGENT CONTROL FOR THREE TANK SYSTEM

CHAPTER 4 AN EFFICIENT ANFIS BASED SELF TUNING OF PI CONTROLLER FOR CURRENT HARMONIC MITIGATION

MODEL BASED CONTROL FOR INTERACTING AND NON-INTERACTING LEVEL PROCESS USING LABVIEW

DESIGN OF INTELLIGENT PID CONTROLLER BASED ON PARTICLE SWARM OPTIMIZATION IN FPGA

IJITKM Special Issue (ICFTEM-2014) May 2014 pp (ISSN )

Load frequency control of interconnected system

International Journal on Emerging Technologies 7(1): 25-36(2016) A Review of Structure & Performance of Thermal Power Plant Controllers

Stability Control of an Interconnected Power System Using PID Controller

Comparison Effectiveness of PID, Self-Tuning and Fuzzy Logic Controller in Heat Exchanger

Md. Aftab Alam, Dr. Ramjee Parsad Gupta IJSRE Volume 4 Issue 7 July 2016 Page 5537

CHAPTER 6 ANFIS BASED NEURO-FUZZY CONTROLLER

NEURAL NETWORK BASED LOAD FREQUENCY CONTROL FOR RESTRUCTURING POWER INDUSTRY

DEPARTMENT OF ELECTRICAL AND ELECTRONIC ENGINEERING BANGLADESH UNIVERSITY OF ENGINEERING & TECHNOLOGY EEE 402 : CONTROL SYSTEMS SESSIONAL

Auto-tuning of PID Controller for the Cases Given by Forbes Marshall

Performance Evaluation of Negative Output Multiple Lift-Push-Pull Switched Capacitor Luo Converter

Performance Analysis of PSO Optimized Fuzzy PI/PID Controller for a Interconnected Power System

ADVANCES in NATURAL and APPLIED SCIENCES

Andrea Zanchettin Automatic Control 1 AUTOMATIC CONTROL. Andrea M. Zanchettin, PhD Winter Semester, Linear control systems design Part 1

Design of PID Controller for Higher Order Discrete Systems Based on Order Reduction Employing ABC Algorithm

An Implementation for Comparison of Various PID Controllers Tuning Methodologies for Heat Exchanger Model

STABILITY IMPROVEMENT OF POWER SYSTEM BY USING PSS WITH PID AVR CONTROLLER IN THE HIGH DAM POWER STATION ASWAN EGYPT

ANALYSIS OF V/f CONTROL OF INDUCTION MOTOR USING CONVENTIONAL CONTROLLERS AND FUZZY LOGIC CONTROLLER

LOAD FREQUENCY CONTROL FOR TWO AREA POWER SYSTEM USING DIFFERENT CONTROLLERS

High Frequency Soft Switching Boost Converter with Fuzzy Logic Controller

Cohen-coon PID Tuning Method; A Better Option to Ziegler Nichols-PID Tuning Method

DC Motor Speed Control for a Plant Based On PID Controller

A High Step up Boost Converter Using Coupled Inductor with PI Control

Fuzzy Gain Scheduled PI Controller for a Two Tank Conical Interacting Level System

ADJUSTMENT OF PARAMETERS OF PID CONTROLLER USING FUZZY TOOL FOR SPEED CONTROL OF DC MOTOR

Simulation of Optimal Speed Control for a DC Motor Using Conventional PID Controller and Fuzzy Logic Controller

Loop Design. Chapter Introduction

ISSN: [Appana* et al., 5(10): October, 2016] Impact Factor: 4.116

automatically generated by ANFIS system for all these membership functions.

SELF-TUNING OF FUZZY LOGIC CONTROLLERS IN CASCADE LOOPS

Development of a Fuzzy Logic Controller for Industrial Conveyor Systems

Modelling for Temperature Non-Isothermal Continuous Stirred Tank Reactor Using Fuzzy Logic

A.V.Sudhakara Reddy 1, M. Ramasekhara Reddy 2, Dr. M. Vijaya Kumar 3

Transcription:

This work by IJARBEST is licensed under a Creative Commons Attribution 4.0 International License. Available at https://www.ij arbest.com Comparative Analysis Between Fuzzy and PID Control for Load Frequency Controlled Power Murumulla Vamsi 1, Mr. Rajesh Satti 2 1 PG Scholar, Department of Electrical and Electronics Engineering, Swamy Vivekananda Engineering College, Kalavarai, Vizianagaram, India 2 Assistant Professor, Department of Electrical and Electronics Engineering, Swamy Vivekananda Engineering College, Kalavarai, Vizianagaram, India Abstract Steam turbine generation units are used in the power system especially for some special features of fossil-fuelled power plants. When a load disturbance occurred in the system, a frequency variation will cause a primary regulation action on generation units. The units will automatically adjust their outputs to fit for the new load demand. Variation of the governing valve position may exceed to the outlet pressure of the related boiler but boiler often has a long control time cycle after the pressure error was observed. Fuzzy PID controller is usually used to speed up the regulation procedure of boiler and to improve the stability of the steam parameters upstream of steam turbine. Model parameter identification is one of the most reliable tools to estimate the model parameters. In the proposed work, a general model of power plant with Fuzzy and Fuzzy PID control system is built for power system dynamic analysis. The model responses will be compared with Fuzzy and Fuzzy PID for system frequency stability. Index Terms PID controller, Fuzzy control, Fuzzy PID control system, dynamic model, Parameter identification, power plant. I. INTRODUCTION Steam turbine generation units are used in the power system for some special features of fossil-fuelled power plants. When a load disturbance occurred in the system, frequency variation will cause a primary regulation action on generation units. The units will automatically adjust their outputs to fit for the new load demand. Variation of the governing valve position may exceed to the outlet pressure of the related boiler but boiler often has a long control time cycle after the pressure error was observed. PID controller and FPID controller is usually used to speed up the regulation procedure of boiler and to improve the stability of the steam parameters upstream of steam turbine. Many researchers have studied the mathematic models of power plant for power system dynamic analysis. According to their research, low order models for turbine units are more popular for power system dynamic analysis. According to huge test experiences, single turbine model is not without a consideration of a main stream pressure variation. Boiler model is also needed for some circumstances. Control System of boiler and the PID controller and FPID controller acting on both the boiler and turbine systems will have great impact on the pressure stability even output power of turbine units. But these control systems are not well considered in relative research.in this paper, a fossil-fuel power plant model is presented with PID controller and FPID controller power system analysis. The model parameters are identified for a turbine coal fired generation unit. The model responses are compared to the model without PID controller and FPID controller model to evaluate the impact of PID controller and FPID controller model on system frequency stability. Frequency 17

response models have received limited treatment in the literature. The basic concept of the model derived here is based on the idea of uniform or average frequency, where synchronizing oscillations between generators are filtered out, but the average frequency behaviour is retained. The synchronizing oscillations are, taken from the simulations of reference [l].we seek to average these individual machine responses with a smooth curve that can be used to represent the average frequency for the system. Such a filtered or average frequency.. Similar and related approaches have been pursued more recently [3, 4] through work on energy functions. The basic ideas are also important in the work on system Area control simulators [5, 6],as well as the work on long term dynamics [7, 8].In addition to these resources, certain ideas have also been adopted from the work on coherency based dynamic equivalents [9, 10], as well as the work on transient energy stability analysis. A Genetic Algorithm (GA) represents a heuristic search technique based on the evolutionary ideas of natural selection and genetics. Although randomized, using the historical information they direct the search into the region of better performance within the search space. In this paper, the PID and FPID controller is developed and compared with respect to their overshoot or undershoot and settling time under various operating conditions for a two area steam turbine and boiler model. II. MODELING OF STEAM TURBINE In a steam turbine the stored energy of high temperature and high pressure steam is converted into mechanical (rotating) energy, which then is converted into electrical energy in the generator. The original source of heat can be a furnace fired by fossil fuel (coal, gas, or oil) or biomass. The turbine can be either tandem compound or cross compound. In a tandem compound unit all sections are on the same shaft with a single generator, while a cross compound unit consists of two shafts each connected to a generator. The cross compound unit is operated as one unit with one set of controls. The power output from the turbine is controlled through the position of the control valves, which control the flow of steam to the turbines. The valve position is influenced by the output signal of the turbine controller. High Pressure (HP), Intermediate Pressure (IP) and Low Pressure (LP) are the different turbine sections. The turbine considered for study in this paper is reheating type.reheating improves efficiency [8].The effects of steam chest; reheated and nonlinear characteristics of control valve are considered. The fraction of turbine power generated by intermediate section is assumed as negligible on base value Fig.1 steam turbine model Steam flow entered into steam turbine gs is proportional to sum of the product of governing valve position variation PGV and steam pressure variation of superheated Ps and two variations themselves. TH, TR and TL are time constants of three equivalent steam volume as high 18

pressure volume, reheated volume and crossover volume, and Pg, Pr and Pc are average steam pressures of three volumes. Output power is a sum of output by three kinds of turbine cylinder. Power of each cylinder is considered to be proportion to its inlet steam pressure due to high pressure ratio. Relative with the rated output power the output portions of three cylinders are KH, KR and KL respectively. III. PID CONTROLLER One of the usual compensators that are widely used is PID controller. The combination of lead and lag compensators is used to achieve desired transient behaviour and low steady state error. The structure of this compensator that has been used in this study A proportional integral derivative controller (PID controller) is a generic control loop feedback mechanism controller) widely used in industrial control systems a PID is the most commonly used feedback controller. A PID controller calculates an "error" value as the difference between a measured process variables and a desired set point. The controller attempts to minimize the error by adjusting the process control inputs. The PID controller calculation algorithm involves three separate constant parameters, and is accordingly sometimes called three-term control: the proportional, the integral and derivative values, denoted P,I, and D. Heuristically, these values can be interpreted in terms of time: P depends on the present error, I on the accumulation of past errors, and D is a prediction of future errors, based on current rate of change. The weighted sum of these three actions is used to adjust the process via a control element. In this tutorial we assume the controller is used in closed loop unity feedback system the variable de note the tracking error which is send to the PID controller. The controller single u form the controller to plant equal to the Proportional gain ( ) time magnitude error gain Integral gain ( ) time the integral of the time pulse the Derivative gain ( ) times the derivative of the error. Fig.2 Block diagram of a PID controller IV. FUZZY PID CONTROLLER Although it is possible to design a fuzzy logic type of PID controller by a simple modification of the conventional ones, via inserting some meaningful fuzzy logic IF- THEN rules into the control system, these approaches in general complicate the overall design and do not come up with new fuzzy PID controllers that capture the essential characteristics and nature of the conventional PID controllers. Besides, they generally do not have analytic formulas to use for control specification and stability analysis. The fuzzy PID controllers to be introduced 19

below are natural extensions of their conventional versions, which preserve the linear structures of the PID controllers, with simple and conventional analytical formulas as the final results of the design. Thus, they can directly replace the conventional PID controllers in any operating control systems (plants, processes). The conventional design of PID controller was somewhat modified and a new hybrid fuzzypid controller was designed. Instead of summation effect a mamdani based fuzzy inference system is implemented. The inputs to the mamdani based fuzzy inference system are error and change in error.the main difference is that these fuzzy PID controllers are designed by employing fuzzy logic control principles and techniques, to obtain new controllers that possess analytical formulas very similar to the conventional digital PID controllers. Fig.3 Fuzzy Inference System Editor Fuzzy PID Controller TABLE 1: RULE TABLE FOR FPID CONTROLLER 20

V. TWO AREA STEAM TURBINE MODEL SIMULATIONS RESULTS Fig.4 Two Area system with Fuzzy controller Fig.5 Two Area system with Fuzzy PID Controller Fig.6 Frequency response with Fuzzy controller Fig.7 Frequency response with Fuzzy PID controller In the above graphs firstly, a step load disturbance occurs in two areas (area1&area2) with step load increasing of 0.03p.u. With the use of a PID controller with a step load disturbance of 21

0.03p.u rise time has been reduced to 0.32s, settling time to 9.97 and overshoot is reduced to 137.With the use of a fuzzy PID controller with a step load disturbance of 0.03p.u rise time has been reduced to 0.3s, settling time to 9.97 and overshoot is reduced to 125.2. A. Steam turbine model: The steam turbine is mostly large power reheat units. There are multi low pressure cylinders and even multi intermediate pressure cylinders. The intermediate pressure cylinders can be considered as for the dynamic analysis. TH High pressure temperature TR Reheat temperature TL Lower pressure temperature Table 2: Time constant value for turbine model TH 0.26s TR 18.5s TL 0.69s VI. CONCLUSIONS For supplying stable and reliable electric power, load frequency control is an important issue in power system operation and control. Automatic load frequency control is used to maintain the generator power output and frequency within the prescribed values. In this work the two area load frequency controller is considered. The simulated study shows the frequency response and steady state response of two area systems by using fuzzy and fuzzy PID. The fuzzy is compared with fuzzy PID. Two similar areas are given with a disturbance of 0.05p.u. The simulation study shows that the stability of the system improved the frequency response and less settling time and steady state responses. Hence from the results we conclude that the Fuzzy PID is said to be better compensating then fuzzy controller. REFERENCES [1] Power system Stability and Control by Prabhakundur. [2] Power System Engineering bynagrath Kothari [3] IEEE Committee Report, "Dynamic Models for Steam and Hydro Turbines in Power System Studies", IEEE Trans Power Apparatus & Systems, Vol. 92, No. 6, 1973, pp. 1904-1915. [4] L. N. Bize, J. D. Hurley, "Frequency Control Considerations for Modem Steam and Combustion Turbines", IEEE Engineering Society Winter Meeting, 1999, pp. 548-553. [5] Dai Yipping, Zhao Ting, TianYunfeng, Gao Lin, "Research on the influence of primary frequency control distribution on power system security and stability", Second IEEE Conference on Industrial Electronics and Applications, 2007, pp.222-226. [6] P. M. Anderson, M. Mirheydar, "A low-order system frequency response model", IEEE Transaction on Power Systems, Vol. 5, No. 3, 1990, pp. 720-729 [7] K. J. Astrom, K.Eklund, "A simplified non-linear model of a drum boiler-turbine unit", International Journal of Control, Vol. 16, No. I, 1972,pp. 145-169. [8] de Mello, F.P., "Dynamic models for fossil fuelled steam units in power system studies", IEEE Transactions on Power Systems, Vol. 6, No. 2,1991, pp. 753-761. [9] Dai Yipping, Zhao Ting, TianYunfeng, Gao Lin, "Research on the primary frequency control characteristics of generators in power system,second IEEE Conference on Industrial Electronics and Applications,2007, pp. 569-574. [10] QH WU, "Learning coordinated control of power systems using interconnected learning automata", Electrical power & Energy systems, Vol. 17, No. 3, 1995, pp.91-99. 22

[11] Gao Lin, Dai Vi-ping, Xia lun-rong, "A New Framework for Power System Identification Based on an Improved Genetic Algorithm", 2009 4th IEEE Conference on Industrial Electronics and Applications, May 25-27,2009, Xi'an, China. [12] Gao Lin, Dai Vi-ping, Xia Jun-rong, "Parameter Identification of Hydro Generation System with Fluid Transients Based on Improved Genetic Algorithm", 2009 Fifth International Conference on Natural Computation, 14-16 August 2009, Tianjin, China [13] H.R.Berenji, Fuzzy logic controllers, in: R.R. Yager,L.A.Zadeh(Eds.), An Introduction to Fuzzy Logic Application in Intelligent System, Kluwer Academic Publisher, Boston, MA, 1992. [14] W.R.HwangandS.ZeinSabatto. FuzzyControllerDesignUsing Genetic Algorithm in Engineering newcentury, Proceeding, IEEE, April 1997 23