TUF Ultrasonic Flow Meter. One. Overview V =

Similar documents
Handheld Ultrasonic Flowmeter

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

Advanced instrumentation solutions crafted with highest precision

Infocal 9 Energy calculator

Model Sono-Trak Transit Time

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

SonoMeter 31 Energy Meters

Clamp-on Fixed Type Ultrasonic Flowmeter

B850 Boiler House Energy Monitor

Hand Held Ultrasonic Flow Meter

Handheld Ultrasonic Flow meter User Manual

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

Technical Specification FLUXUS ADM 8x27

Ambient Conditions. Operating Conditions. Pressure

Supercal 531 Multi function Integrator that lives up to Your highest expectations

TDS-100H Handheld Ultrasonic Flowmeter. User manual

mass flowmeter for compressed air

Ultrasonic level meters ULM 70

TDS-100H Handheld Ultrasonic Flowmeter. User manual

Safsonic P. Handheld Ultrasonic Flow meter. User Manual

Electro-Magnetic Flowmeters COPA-XE

SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter

Temperature measuring instrument (2-channel)

ADDMAS CORIOLIS MASS FLOW METER

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Handheld Ultrasonic Flow Meter. Series TFM1100-P. User Manual

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

HTTF Transit Time Ultrasonic Flow Meter

Brunata Optuna H. Properties. Counter

wprime TM Series 280W-CI ULTRASONIC WATER METER

EN-2018 MAGNETIC FLOW METERS

KATflow 230 Portable Clamp-On Ultrasonic Flowmeter

Digital flow transmitter for continuous flow measurement

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

LZYN Triangle Series Mass Flow Meter

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Additel 875 Series Dry Well Calibrators

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

CALYS 75. Field documenting multifunction calibrator

ClampOn, Inc. Ultrasonic Intelligent Sensors. Presented by Hans A. Wagner

FMU-2000F PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

Target disk flowmeter for liquids and gases

QUALITY SELECTION. Cable Fault Location & Condition Based Maintenance. Siyphambili Electrical & Industrial Supplies cc

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

DRS390 High stability, flange mounting

ATG SERIES Growco Servo Tank Gauges

Technical Specification FLUXUS ADM 8127B

Moving Test - MT3000

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

Temperature measuring instrument (2-channel)

FH CMF Coriolis Mass Flow Meters

Ultrasonic level transmitter Datasheet

Temperature measuring instrument (1-channel)

Technical specification FLUXUS F401 H2O

Versatility for Ventilation and Indoor Air Quality

MEMOCAL 2000/2000S. Hand-held calibrator

All-round Talent for Ventilation and Room Air Quality

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

IFC 010 Signal Converter

ULTRASONIC FLOW METER FT101

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Magnetostrictive Level Transmitter

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES

Multi-function measuring instrument

Dx: Digital Multi-Channel Telemetry System

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B

B850 Boiler House Energy Monitor

1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

CALYS 100. Field precision documenting multifunction calibrator

testo 735, highly accurate alarm and logger thermometer with measurement site management

OPTIFLUX 5000 Technical Datasheet

Release A Member of the

ph or ORP Transmitter

CALYS 50. Field multifunction calibrator for basic use

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Ron 2000 Shackle Type Dynamometer with Remote Indicator

Model R7900. Instruction Manual. Ultrasonic Thickness Gauge. reedinstruments. www. com

Humidity/temperature measuring instrument

CALYS 150. Advanced documenting multifunction calibrator thermometer

( F L O W I Z F A M I L Y )

Design and applications

Electromagnetic Flowmeter Comet F

A T u n e d M e a s u r e

Technical Specifications

Open Channel Flowmeter 713

On-site multifunction calibrator

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

Coriolis Massflowmeter

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Multi-function measuring instrument

Transcription:

One. Overview TUF Ultrasonic Flow Meter series ultrasonic flow meter is designed on the theory of low voltage and time difference of multi pulse. It can be used to measure transmission time of ultrasound in forward stream and reverse stream, using the methods of high accurate and super stable double-balanced signal differential transmission and differential receive digital detection technology. Then calculate the speed of flow by time difference. MD DT V = sin 2q Tup Tdown V: speed of the flow θ:the angle between Sound velocity and the direction of liquid flow M:the straight transmitting times of sound beam in the liquid D:inner diameter of the pipe Tup:transmitting time of the sound beam in positive direction Tdowm:transmitting time of the sound beam in T:Tup-Tdowm It has the trait with high stability, low zero drift and high precision of measurement, wide measuring range and Strong ability of anti-jamming. When the ultrasonic wave transmits in the liquid, the flow of the liquid will slightly change the transmitting time of ultrasound wave. The change of the transmitting time is proportional to the speed of the liquid. When the speed of the liquid is zero, the time of receiving sound wave of the two sensors is the same (the only way to measure zero speed). When the liquid flows, the transmitting time of sound wave in the forward stream is longer than that in the reverse stream. The equation is as follows: reverse direction TUF Series 동양계기교역 ( 주 ) TEL: (02) 2025-0560, FAX: (02) 2025-0565 - 1 -

Portable type Ultrasonic Flow Meter 2000P 고정밀도 Linearity 0.5% Repeatable accuracy 0.2% Measuring accuracy ±1%, Intact measuring Put the sensor of magnetic ultrasonic flow meter on the pipe wall, then it can finish the measurement of flow large measuring range measure the flow from DN15 to DN6000mm with different sensors support English menu Different types of flow meter can support English menu conveniently. Rechargeable power source Built-in Ni-MH rechargeable battery with large capacity which can support flow meter to work lastly over 20 hours. Built-in printer Besides printing the content on the screen in time, it can also print over 20 measuring results set ahead of time built-in data recording machine upload over 20 results set ahead of time to computer or internet 1. outside clip sensor with magnetism 2. menu in English 3. built-in printer 4. high strength aluminum protective box Standard type Model Amount Description host 2000P one Volume: 225 180 67mm, working temperature: -20-60, measuring accuracy: ±1% Middle sensor TM-1 two With magnetism, Special cable for ultrasound two Volume: 64 35 32mm working temperature: -40-110 measuring range: DN50-DN1000mm Length: 5m, Used to connect sensor and host of ultrasonic flow meter Power cable one Length:3m, used for recharging the host of ultrasonic flow meter or ACuse, measuring long time TUF Series 동양계기교역 ( 주 ) TEL: (02) 2025-0560, FAX: (02) 2025-0565 - 2 -

Thermal induction printing paper Special coupling paste for Two volume one Length is 30m Weight: 110g, Used for ultrasonic sensor and ultrasound transmission ultrasound between pipe walls tensioner two Length: 3m, Maximum pull force: 100Kg Used for Non-magnetic pipe bundled sensor Rolling tape one Length: 3m Aluminum Alloy protective box one Used to measure the circumference of pipe or the installation distance between two probes Volume: 415 315 100mm Suitable for use in the open air and harsh environment under petroleum drilling Matched sensors Model Description Measuring range Temperature range Small sensor TS-1 With magnetism DN15-DN100MM -40-110 Middle sensor TM-1 With magnetism DN50-DN1000MM -40-110 Large sensor TL-1 With magnetism DN300-DN6000MM -40-110 High temperature small sensor High temperature middle sensor Ultrasonic thickness measuring meter Lengthened signal cable HTS-1 DN15-DN100MM -40-160 HTM-1 DN50-DN1000MM -40-160 TT100 Accurately 1.2-225.0mm ±1%H±0.1m measure the mh, it is the thickness of the thickness of pipe wall, measured improving the thing accuracy of the flow detection Length is 10m 2 Suitable to the site where measured pipe is far from host. TUF Series 동양계기교역 ( 주 ) TEL: (02) 2025-0560, FAX: (02) 2025-0565 - 3 -

Lengthened tensioner Thermal induction printing paper Length is 6m 2 Length is 30m It is suitable to fix sensor on the pipe which diameter is over 1000mm. Basic Parameters project Host Sensor Functional parameters 2 20 dot-matrix backlight type LCD. working temperature:-20-60 The output of the printer is 24 rows characters micro heat-variable printer 4 4+2 type touched keyboard, Data interface: RS-232 1. standard TS-1 type, suitable pipe: DN15-100mm, flow temperature 110 2. standard TM-1 type,suitable pipe:dn50-10000mm,flow temperature 110 3. standard TL-1 type, suitable pipe: DN300-6000mm,flowtemperature 110 Medium measured Water, sea water, industry polluted water, acid and alkali liquid, various kinds of oil, which can conduct ultrasound Velocity range 0-±30m/s Measuring Better than±1% accuracy Power supply Ni-MH battery working lasting over 20 hours or AC 220V power 2W Recharge Intelligent recharging type, directly connected with AC220V, stop and light green after recharged well. Weight Net weight 2.0(host) Remarks Matched with high-strength protective box, can work in the open air or harsh environment The coding rules of Portable Type Ultrasonic Flow Meter TUF Series 동양계기교역 ( 주 ) TEL: (02) 2025-0560, FAX: (02) 2025-0565 - 4 -

Hand-held ultrasonic flow meter 2000H high accuracy measuring Accuracy: ±1%, Linearity:0.5% Repeatable accuracy: 0.2% small volume and weight Volume: 210 90 30mm Weight: 0.5Kg Intact measuring Put the sensor of magnetic ultrasonic flow meter on the pipe wall, then it can finish the measurement of flow large measuring range measure the flow from DN15 to DN6000 mm with different sensors rechargeable power supply Built in Ni-MH rechargeable battery with large capacity can make flow meter work over 12 hours big LCD screen It can display cumulative flow, instantaneous flow, flow velocity, working states in the same time built-in data recording machine Room is 24 KB, it can store 2000 lines of data 1. outside clip sensor with magnetism 2. display in big LCD screen 3. standard data interface 4. high strength aluminum protective box Standard model Model Amount Description host 2000H one Volume: 210 90 30mm, working temperature: -20-60, measuring accuracy: ±1% Middle sensor TM-1 two With magnetism, Volume: 64 35 32mm working temperature: -40-110 TUF Series 동양계기교역 ( 주 ) TEL: (02) 2025-0560, FAX: (02) 2025-0565 - 5 -

Special cable for ultrasound two measuring range: DN50-DN1000mm Length: 5m Used to connect sensor and host of ultrasonic flow meter Data cable one Length: 1m Used to export the data stored in data record machine to computer Power supply adapter Special coupling paste for ultrasound one one Length: 1m Used to recharge hand held flow meter Weight: 110g Used for ultrasonic sensor and ultrasound transmission between pipe walls tensioner two Length: 3m Maximum pull force: 100Kg Used for Non-magnetic pipe bundled sensor Rolling tape one Length: 3m Used to measure the circumference of pipe or the installation distance between two probes Manual book one Aluminum Alloy protective box one Volume: 415 315 100mm TUF Series 동양계기교역 ( 주 ) TEL: (02) 2025-0560, FAX: (02) 2025-0565 - 6 -

Matched sensors Model Picture Description Measuring range Temperature range Small sensor TS-1 With magnetism DN15-DN100MM -40-110 Middle sensor TM-1 With magnetism DN50-DN1000MM -40-110 Large sensor TL-1 With magnetism DN300-DN6000MM -40-110 High temperature small sensor High temperature middle sensor Ultrasonic thickness measuring meter Lengthened signal cable Lengthened tensioner HTS-1 DN15-DN100MM -40-160 HTM-1 DN50-DN1000MM -40-160 TT100 Accurately 1.2-225.0mm ±1%H±0.1m measure the mh, it is the thickness of the thickness of pipe wall, measured improving the thing accuracy of the flow detection Length is Suitable to the site where 10m 2 measured pipe is far from host. Length is 6m 2 It is suitable to fix sensor on the pipe which diameter is over 1000mm. Basic Parameters Project Functional parameters Linearity 0.5% Repeatability 0.2% Accuracy ±1% of the displayed value, flow velocity is bigger than 0.2m/s Response time Users can choose it between 0 to 999 seconds Flow velocity range ±32m/s Measuring diameter 15-6000mm Measuring unit Meter, inch, cubic meter, liter, cubic inch, American gallon, English gallon, oil drum, American liquid drum, English liquid drum, America million gallon, all these units are set by users. Cumulative meter 7 digit positive and negative net cumulative meter The kinds of liquid Various types of medium in single and homogenous medium, which can conduct ultrasound. TUF Series 동양계기교역 ( 주 ) TEL: (02) 2025-0560, FAX: (02) 2025-0565 - 7 -

Safety Customers can lock the parameters. Unlock the parameters when they want to set them. Display 4 16inEnglish. C o m m u n i c a t i o n interface RS-232, Baud rate 75-57600. It is compatible with Fujitsu ultrasonic flow meter or other related products according to the need from customers. Sensors Standard M1 type and other four optional types. Sensor cable The standard is 5m 2 and it can be lengthened to 10m 2. Power supply Three AAA built-in Ni-H battery, it can work successively for 12 hours after recharged every time, AC100-240V adapter. Data recording Built-in data recording machine can record data to 2000 lines. Manual cumulative 7-digit, it can calibrate after the button is pressed. meter Material of outer flame retardant ABS shell Size of outer shell 200 90 30mm Weight of the host 500g(1.2Ibs) including battery The coding rules of Hand-held Type Ultrasonic Flow Meter TUF Series 동양계기교역 ( 주 ) TEL: (02) 2025-0560, FAX: (02) 2025-0565 - 8 -

Fixed type Ultrasonic Flow Meter 2000B 2000F High accuracy measuring Linearity is better than 0.5%, repeatability is better than 0.2%, measuring accuracy is better ±1% Large measuring range It can measure the pipes from DN15 to DN6000mm with sensors matched in different models High protective level The protective level of the first meter can reach IP68. it can work at 2 meters beneath water level Convenient operation Besides browsing the parameters on first meter with the help of magnetic bar, it can reset parameters or display Multi-display The first meter has both the function of signal detecting and flow measuring. It can display the cumulative flow in circulation, flow velocity. Secondary meter can display more than 100 menus. Remote transmission and convenient network formation It uses RS-485 bus communication with ordinary cable. Transmitting distance can be reached over 1 kilometer and it can format the net conveniently in a short time. This kind of transmitting type has a strong ability in anti-noise. All the traits solve the problem from split ultrasonic flow meter which is high cost of special cable, bad transmitting distance, etc. quality in anti-noise and short Basic type 2000B small volume with 120 40 25mm lowest price, can only manage flow measuring protective level IP68, with whole plastic water proof realizing local measurement, secondary remote transmission and parameter setting; network measuring Functional type 2000F Besides the function of basic type, it has the additional function as follows: protective level IP68, it can work at 2 meters beneath water level 3-channel 4-20mA analog 2-channel and 3-wire PT-100 resister signal isolation RS232/RS485 output, 2-channel isolation OCT output 1 channel isolation 4-20mA output(no power) TUF Series 동양계기교역 ( 주 ) TEL: (02) 2025-0560, FAX: (02) 2025-0565 - 9 -

Composition Picture of Fixed Ultrasonic flow meter Hanging type 2000FB for hanging installation on the wall size: 178 165 55mm RS485 bus communication (remote transmission over 1Km) Voltage supply:24v Dial fixing type 2000FS for fixing of instrument dial aperture size: 152mm 76mm Explosion proof type 2000FD explosion proof level DⅡBT4, for explosion proof site size:285 265 90nn The sensors that can be matched with fixed type Ultrasonic Flow Meter 2000B traits Basic type Functional type Outside clip type safety with flow, no pressure lose accuracy ±1% it is no need to cut off the convenient to fix and maintain it, customers can fix it by themselves lowest price, no relationship with the measuring diameter suitable to good working environment 2000F B 2000FNB Plug-in type safety with no need to cut off the TUF Series 동양계기교역 ( 주 ) TEL: (02) 2025-0560, FAX: (02) 2025-0565 - 10 -

flow, no pressure lose accuracy ±1% customers can fix it with special aperture opening device after trained higher price, no relationship with the measuring diameter the quality of received signal is excellent and it can run stable and reliable in a long time Standard pipe section type cut off the flow and uninstall pipe when fix it. no pressure lose accuracy ±0.5% cut off the flow when fix and maintain it, customers can fix it by themselves the bigger the measuring diameter is, the higher the price is high accuracy, excellent received signal, it can run stable and reliable in a long time C G 2000FNC 2000FNG Basic Parameters Sensors can be matched O u t s i d e TS-1 clip (small) type TM-1 (middle) TL-1 (large) High TH2-1 temperature (small) outside clip type THM-1 (middle) Plug-in TC-1 type (standard ) Basic model B1 B2 B3 B4 B5 C1 Measuring Fluids range tempera ture DN15-100mm - 3 0-9 0 DN50-1000mm DN300-6000m m DN15-100mm - 3 0-1 6 0 DN300-1000m m DN80-6000mm - 4 0-1 6 0 A c c u r a cy ± 1 % Power Input Output Communication protocol 3-channel 4-20mA The first A n a l o g instrum ent DC8-36 V 2-channel and 3-wire seconda P T 1 0 0 r y resistance instrum ent S i g n a l AC220 V or separated METER-bus RS232/ Protocol RS485 OCT MODBUS 4-20 Protocol ma Fujitsu Expand protocol Simple TUF Series 동양계기교역 ( 주 ) TEL: (02) 2025-0560, FAX: (02) 2025-0565 - 11 -

TLC-2 (lengthen ) C2 DC24V water meter protocol Pipe type s e c t i o n Standard pipe section G DN15-1000mm - 4 0-1 6 0 Fixed Split Ultrasonic Flow Meter 2000S High accuracy meas uring Linearity is better than 0.5%, repeatability is better than 0.2%, measuring accuracy is better ±1%. Large measuring range It can measure the pipes from DN15 to DN6000mm with sensors matched in different models. Support English menu The flow meters in different models can be operated in English menu conveniently and rapidly. High reliability It measures accuracy with low voltage and multi-pulse transmitting circuit, which advances its life and reliability Strong ability of anti-noise It uses double balance signal differential transmitting and receiving circuit, which can effectively resist the noise from inverter, TV tower and high-voltage wire, etc. Strong memory ability Automatic record the cumulative flow in the last 64 days, last 64 months and last 5 years. Automatic record the power supply time, power cut time and flow of the last 64 times. Automatic judge Composition picture Hanging type 2000SB used fo rhanging installation size: 178 165 55mm Host computers that can be ma tched Dial fixing type Explosion proof type 2000SS 2000SD for fixing of instrument explosion proof level dial DⅡBT4, for explosion aperture size: proof site 152mm 76mm size: 285 265 90mm TUF Series 동양계기교역 ( 주 ) TEL: (02) 2025-0560, FAX: (02) 2025-0565 - 12 -

whether working state of the cumulative flow of the last 64 days is normal or not. sensors those can be matche O u t s i d e TS-1 clip-on type (Small model) TM-1 (Middle model) TL-1 (large type) H i g h TH2-1 temperatur (smal e and l type) clip-on type THM-1 (middle type) Plug-in type TC-1 (standar d plug-in) TLC-2 (lengthe ned plug-in) Pipe section Standard type p i p e s e c t i o n type B a s i c models B1 B2 3000BNB3 B4 B5 C1 C2 G Me asuring range DN15-100m m DN50-1000 mm DN300-6000 mm DN15-100m m DN300-1000 mm DN80-6000 mm DN15-1000 mm Temperat ure of flow medium -30-90 -30-160 -40-160 -40-160 accura cy ±1% power output Communicati o n protocol Isolati o n METER-BUS 3 - c h a RS232 protocol First meter D C 8-3 6V nnel 4-20m A analog / RS485 2 - c h a MODUS protocol n n e l Fujitsu 2 - c h a isolati expand Second n n e l o n protocol ary a n d O C T meter AC220 V or DC24V 3-wire PT100 resiste r signal output 1 - c h a n n e l isolati Simple water meter protocol o n 4-20m A output ( n o power source ) TUF Series 동양계기교역 ( 주 ) TEL: (02) 2025-0560, FAX: (02) 2025-0565 - 13 -