cividec DIAMOND DETECTORS & SYSTEMS FOR X-RAYS Instrumentation CIVIDEC Instrumentation GmbH Vienna The Netherlands +31 (0)

Similar documents
cividec PORTFOLIO Instrumentation CIVIDEC Instrumentation GmbH Vienna België / Belgique Nederland

Results from Diamond Detector tests at ELETTRA

pcvd diamond beam position monitors for PETRA III

Nano Beam Position Monitor

Large area position-sensitive CVD diamond detectors for X-ray beam monitoring with extreme position resolution

Diamond Sensors. John Smedley DOE BES Neutron & Photon Detector Workshop

RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS

Simulation of High Resistivity (CMOS) Pixels

ESRF. Tests of a diamond quadrant detector at Hasylab (DESY) using the Libera Brilliance. European Synchrotron Radiation Facility, France

GSPC detectors development for neutron reflectometry and SANS Instruments WP22 / Task 22.2

MICRO XRF OF LIGHT ELEMENTS USING A POLYCAPILLARY LENS AND AN ULTRA THIN WINDOW SILICON DRIFT DETECTOR INSIDE A VACUUM CHAMBER

First test experiments with FMB- Oxford direct drive DCM at the Sirius beamline of Synchrotron SOLEIL

Capacitive sensors capancdt

Characterization of SC CVD diamond detectors for heavy ions spectroscopy

Introduction to X-ray Detectors for Synchrotron Radiation Applications

Supplementary Information

Three Laminar Profile Spherical Gratings for the Madison SGM Beamline. Technical Specification

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

x-ray Beam Size Monitor

Characterisation of a novel super-polished bimorph mirror

Strip Detectors. Principal: Silicon strip detector. Ingrid--MariaGregor,SemiconductorsasParticleDetectors. metallization (Al) p +--strips

Pixel Array Detectors: Counting and Integrating

PSD Characteristics. Position Sensing Detectors

queensgate a brand of Elektron Technology

X-Ray Beam Position Monitor Based on a Single Crystal Diamond Performing Bunch by Bunch Detection

CESRTA Low Emittance Tuning Instrumentation: x-ray Beam Size Monitor

Copyright -International Centre for Diffraction Data 2010 ISSN

Scanning Electron Microscopy. EMSE-515 F. Ernst

easypll UHV Preamplifier Reference Manual

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

Multi-Element Si Sensor with Readout ASIC for EXAFS Spectroscopy 1

CAPACITIVE SENSORS. Series KS. Key-Features:

12/08/2003 H. Schlarb, DESY, Hamburg

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT

BL39XU Magnetic Materials

PICMA Stack Multilayer Piezo Actuators

Week 9: Chap.13 Other Semiconductor Material

Advances in microchannel plate detectors for UV/visible Astronomy

portable scanner based on monolithic semi-insulating

Experience of synchrotron sources and optics modelling at Diamond Light Source

OPTICAL SENSORS-CONSTRUCTION ALTERNATIVES

Implementation of A Nanosecond Time-resolved APD Detector System for NRS Experiment in HEPS-TF

Introduction of New Products

VIBRATING WIRE SENSORS FOR BEAM INSTRUMENTATION Suren Arutunian

Optical Amplifiers. Continued. Photonic Network By Dr. M H Zaidi

Instruction manual and data sheet ipca h

MASW P. SURMOUNT PIN Diode Switch Element with Thermal Terminal. Features. Description. Ordering Information 2.

Fully depleted, thick, monolithic CMOS pixels with high quantum efficiency

Improvement of Energy Resolutions for Planar TlBr Detectors Using the Digital Pulse Processing Method

Goals of the Lab: Photodetectors and Noise (Part 2) Department of Physics. Slide 1. PHYSICS6770 Laboratory 4

Schematic diagram of the DAP

Micro-nanosystems for electrical metrology and precision instrumentation

PicoMaster 100. Unprecedented finesse in creating 3D micro structures. UV direct laser writer for maskless lithography

Luminous Equivalent of Radiation

X-ray Detectors: What are the Needs?

Bringing Answers to the Surface

Development of Solid-State Detector for X-ray Computed Tomography

99. Sun sensor design and test of a micro satellite

TechNote. T001 // Precise non-contact displacement sensors. Introduction

Large-Area CdTe Photon-Counting Pixel Detectors

PICO MASTER 200. UV direct laser writer for maskless lithography

Performance characterization of a novel thin position-sensitive avalanche photodiode-based detector for high resolution PET

Overview of performance and improvements to fixed exit double crystal monochromators at Diamond. Andrew Dent, Physical Science Coordinator, DLS

Product Range Electronic Units

CADMIUM Telluride (CdTe) and Cadmium Zinc Telluride

Laser tests of Wide Band Gap power devices. Using Two photon absorption process

Compact Photonics Control Solutions

Investigate the characteristics of PIN Photodiodes and understand the usage of the Lightwave Analyzer component.

Optical behavior. Reading assignment. Topic 10

SUPERCONDUCTIVE ELECTRONICS FOR EUROPE MEMBERS OF THE ROADMAP TEAM

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

How Does One Obtain Spectral/Imaging Information! "

New applications are transforming the UV-LED market, and Nikkiso Deep UV-LED devices are applicable to many important applications including:

PL112 PL140 PICMA Bender

Parallel Ionization Multiplier(PIM) : a new concept of gaseous detector for radiation detection improvement

Q-Motion Miniature Linear Stage

Detection Beyond 100µm Photon detectors no longer work ("shallow", i.e. low excitation energy, impurities only go out to equivalent of

Status of the Continuous Ion Back Flow Module for TPC Detector

Title detector with operating temperature.

Superconducting Nanowire Single Photon Detector (SNSPD) integrated with optical circuits

Beam Loss monitoring R&D. Arden Warner Fermilab MPS2014 Workshop March 5-6, 2014

Measurements of Small Vertical Beamsize using a Coded Aperture at Diamond Light Source. C. Bloomer G. Rehm J.W. Flanagan

Advances in X-Ray Scintillator Technology Roger D. Durst Bruker AXS Inc.

NON-AMPLIFIED HIGH SPEED PHOTODETECTOR USER S GUIDE

Next generation microprobes: Detector Issues and Approaches

Nd:YSO resonator array Transmission spectrum (a. u.) Supplementary Figure 1. An array of nano-beam resonators fabricated in Nd:YSO.

Optical Receivers Theory and Operation

Tabletop-scale EUV coherent imaging using High Harmonic Light

MICROMACHINED INTERFEROMETER FOR MEMS METROLOGY

Optical design of shining light through wall experiments

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Marten Bosma 1, Alex Fauler 2, Michael Fiederle 2 en Jan Visser Nikhef, Amsterdam, The Netherlands 2. FMF, Freiburg, Germany

Examination Optoelectronic Communication Technology. April 11, Name: Student ID number: OCT1 1: OCT 2: OCT 3: OCT 4: Total: Grade:

THE ELECTROMETRIC AC-DC TRANSFER STANDARD AS PRIMARY STANDARD AT IEN FOR AC VOLTAGES FROM 300 V TO 1000 V

Lecture 18: Photodetectors

Study of X-ray radiation damage in silicon sensors

Subminiature Photoionization VOC Sensor Boris Dolgov, Baseline-MOCON, Inc.

ARCoptix. Radial Polarization Converter. Arcoptix S.A Ch. Trois-portes Neuchâtel Switzerland Mail: Tel:

DInGaAs Series. Spectroscopy Detectors PROFESSIONAL DINGAAS SERIES DETECTORS DINGAAS SERIES TE COOLED INGAAS DETECTORS

LYNXEYE XE-T. < 380 ev. Innovation with Integrity. Energy. Resolution. High-Resolution Position Sensitive Detector with Superb Energy Resolution XRD

Transcription:

cividec Instrumentation DIAMOND DETECTORS & SYSTEMS FOR X-RAYS CIVIDEC Instrumentation GmbH Vienna +32 (0)3 309 32 09 info@gotopeo.com www.gotopeo.com

CONTENTS Introduction... 3 Monitors Diamond XBPM System... 4 Detectors Diamond XBPM... 6 20160309 2 I CIVIDEC Instrumentation

INTRODUCTION DIAMOND DETECTORS AND SYSTEMS FOR X-RAYS CIVIDEC Instrumentation developed a range of diamond detectors and monitors for the detection of X-rays. The high transmission, low absorption and high thermal conductivity of the metallized single crystal CVD diamond sensor provide the perfect foundation for the detection of a wide range of X-ray intensities. Combining the Diamond XBPM with the dedicated CIVIDEC Electrometer Amplifiers, the following applications are viable for a wide range of X-ray intensities: X-ray beam position monitoring X-ray beam intensity measurements X-ray beam profile measurements To complete the Diamond XBPM Systems, ROSY Applications for all XBPM amplifier combinations are available. All CIVIDEC XBPM detectors are UHV compatible. CIVIDEC Instrumentation GmbH Schottengasse 3A/1/41 A-1010 Vienna, Austria phone: +43 1 9229307 office@cividec.at www.cividec.at CIVIDEC Instrumentation I 3

A6 Diamond XBPM System A turn-key solution for X-ray beam position monitoring The CIVIDEC X-Ray Beam Position Monitoring System consists of a Diamond XBPM, dedicated Electrometer Amplifiers and the user-friendly Readout System ROSY. Every part of the XBPM System has been optimized in order to achieve the best possible position resolution and facilitate beamline controlling. Dedicated Electrometer In order to offer the best possible resolution, low-noise C8 Electrometer Amplifiers have been developed. To cover a wide range of X-ray intensities, three different amplifiers are available: C8-Pico, C8-Nano and C8-Micro. Superior position resolution The featured Diamond XBPM has a gap size of only 2 μm between the pads, which ensures the best position resolution for X-ray beams 0.1% of the beamsize and nanometer resolution for micrometer beams. Dedicated readout-system The CIVIDEC readout-system ROSY offers real-time signal processing and on-line noise suppression. The data can be either monitored with the GUI (graphical user interface), or read out by the user control system. Linear signal response With the Diamond XBPM System, linear measurements from 5 kev to 25 kev photons in the range of 10 5 to 10 15 photons/s are viable. Applications X-ray beam position monitoring X-ray beam intensity measurements X-ray beam profile measurements Reference Diamond Light Source The Diamond XBPM System has been developed in cooperation with Diamond Light Source Ltd. It was the goal to produce an XBPM with an excellent position resolution and high transmission at low X-ray energies. Several Diamond XBPMs are already in use at Diamond Light Source Ltd. Copyright 2016 These specifications are subject to change without notice. 4 I CIVIDEC Instrumentation

Product Information A6 Diamond XBPM System Parameters Sensor Measurement precision Transmission Vacuum compatibility Carrier material scvd diamond 0.1% of beam size > 90% for 7.8 kev X-rays UHV Ceramics Position resolution [%] 10-1 10-2 10-3 10-4 10 7 10 8 10 9 10 10 10 11 10 12 Total incident fl ux at 12.6 kev [photons/s] Detector current 1 ma 100 μa 5 kev 10 kev C8 Micro 10 μa 15 kev 1 μa 20 kev 100 na 25 kev C8 Nano 10 na 60 kev 1 na C8 Pico 100 pa 10 pa 1 pa 10 4 10 5 10 6 10 7 10 8 10 9 10 10 10 11 10 12 10 13 10 14 10 15 10 16 Beam intensity [photons/s] Figure. The position resolution relative to the beamsize versus the total incident fl ux at 12.6 kev photons/s shows that less than 0.1% of the beamsize can be achieved, which results in nanometer precision for microbeams. Reference: Measurements at Diamond Light Source Ltd. Figure. The detector response as a function of the photon energy and intensity demonstrates the wide dynamic range of the XBPM System in combination with the C8 Electrometer Amplifi ers. Diamond Detector Structure Active area Substrate thickness Pad separation Electrode material 4 quadrants 3 mm in diameter 50 μm 2 μm Titanium Electrometer Amplifier Range Bandwidth Noise (rms) C8-Pico 10 000 pa 100 Hz < 0.5 pa C8-Nano 1000 na 1 khz < 10 pa C8-Micro 1000 μa 10 khz < 5 na Readout System ROSY On-line noise suppression Real-time signal processing Low latency Graphical user interface Integration into control systems Copyright 2016 These specifi cations are subject to change without notice. CIVIDEC Instrumentation I 5

B9 High-Precision Diamond XBPM for precision X-ray beam position measurements The CIVIDEC Diamond XBPM is a four-quadrant solid-state detector with a wide dynamic range and an unprecedented position resolution in the nanometer range. The Diamond XBPM is suited for X-ray synchrotron beamlines and it is easy to install and use. Excellent X-ray transparency Due to the intrinsic properties of diamond and the dedicated electrodes, this product has an excellent X-ray transparency. The Diamond XBPM allows measurements with high transmission, also at low X-ray energies. Unprecedented resolution The small gap size of 2 μm ensures the best possible position resolution for X-ray beams: the position resolution is 0.1% of the beamsize and therefore in the nanometer range for micro-beams. Extreme conditions The high-end fabrication of the Diamond XBPMs make them viable for applications in UHV vacuum. This results in a long lifetime and in excellent long-term stability of the detector. Linear signal response Another main benefit of the Diamond XBPM is that it allows linear measurements from 5 kev to 25 kev photons in the range of 10 5 to 10 15 photons/s. Applications X-ray beam position monitoring X-ray beam intensity measurements X-ray beam profile measurement Copyright 2016 These specifications are subject to change without notice. 6 I CIVIDEC Instrumentation

Product Information B9 High-Precision Diamond XBPM Parameters Sensor Position precision Transmission Vacuum compatibility Carrier structure scvd diamond 0.1% of beam size > 90% for 7.8 kev X-rays UHV Ceramics 1 1 Transmission 0.8 0.6 0.4 0.2 Signal [normalised] 0.8 0.6 0.4 0.2 0 5 10 15 20 25 Beam Energy [kev] 0-100 -80-60 -40-20 0 20 40 60 80 100 Beam Position [μm] Figure. The transmission of the XBPM versus the X-ray energy shows the low absorption at low X-ray energies. The negligible impact of the electrodes is demonstrated. Figure. The normalized signal response relative to the beam size as a function of the beam position demonstrates the linear transition from one quadrant to the other for a 25 μm beam. Reference: Measurements at Diamond Light Source Ltd. Features Structure Active area Substrate thickness Pad separation Electrode material 4 quadrants 3 mm in diameter 50 μm 2 μm Titanium Copyright 2016 These specifications are subject to change without notice. CIVIDEC Instrumentation I 7

CIVIDEC Instrumentation GmbH Schottengasse 3A/1/41 A-1010 Vienna, Austria phone: +43 1 9229307 office@cividec.at www.cividec.at +32 (0)3 309 32 09 info@gotopeo.com www.gotopeo.com