CURRENT FUTURE REGULATIONS PROPOSALS

Similar documents
17TH EDITION BS TH EDITION BS7671 HOW THIS AFFECTS YOU. A BITESIZE LOOK at RCDs and parts of the 18th edition DPC. wylexreasons.co.

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011

TN, TT & IT Earthing Arrangements

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations. Earth Fault Loop Impedance Tests

Automatic disconnection of lighting circuits from dimming equipment

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented

7 o/c4 - To meet the requirements of BS 7671, all fault current protective devices without back-up protection on the supply side must be capable of:

Les Hampson Cert Ed FSCTE, Chairman CAI Technical Committee

Licensed Electricians Practical Assessment (LEP)

Module Title: Electrical Installation II Laboratory Sheet:

FINAL - ER 70 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes

APRIL 2017 Level 3 Advanced Technical Diploma in Electrical Installation (450) Level 3 Electrical Installation Theory Exam

ELECTRICIAN S THEORY EXAMINATION 20 November 2010 QUESTION AND ANSWER BOOKLET

Product Classroom. Introduction. Grounding Systems. TN system. Title. Grounding System Introduction. Date October, 2016.

2394 EXAM PAPER. 1. State THREE circumstances that would require a periodic inspection and test to be carried out on an installation

ET 51 - Electrician Theory Examination Marking Schedule

Grounding and Lightning arrestors

Company Directive STANDARD TECHNIQUE: SD5F. Relating to connecting multiple small low voltage connections with limited network analysis

FINAL - IT 30 ELECTRICAL INSPECTOR EXAMINATION ANSWER SCHEDULE. Question 1 Marks Reference Marking notes. (2 marks) EA 2

Protective earthing, protective conductor and automatic disconnection in case of a fault (Fault protection)

Licensed Electricians Practical Assessment (LEP)

ELECTRICIAN S THEORY EXAMINATION 15 November 2014 QUESTION AND ANSWER BOOKLET

ER 87 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) ESR 27(2) (2 marks) ESR 74A(1AA)

NOTE: This paper relates to a closed book exam & therefore candidates should attempt this exam paper with no study-notes or text books.

MinorWorks/Single Circuit Electrical Certificate

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

lama M:ZSO 2SA 30oM 11ov m

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations

Code for Design of Low Voltage Electrical Installations

INSTRUCTION MANUAL DIGITAL PSC-LOOP TESTER MODEL 4118A KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD.

1. general. 1.1 electric shock. 1.2 direct and indirect contact. electric shock. indirect contact. direct contact

Residual current circuit breakers (RCCBs)

Residual Current Operated Circuit-Breakers (RCCBs)

Company Directive STANDARD TECHNIQUE: SD5R/2. Earth Fault Loop Impedances and Phase to Neutral Loop Impedances at LV Installations

Chapter F Protection against electric shocks

Choice of earth leakage protection devices

MASTECH MS5908. Circuit Analyzer

Chapter 6. WIRING SYSTEMS Safe Electrical Design

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

TS RES - OUTSTANDING ISSUES

Safety of programmable machinery and the EC directive

Chapter F Protection against electric shocks

Residual Current Operated Circuit-Breakers (RCCBs)

FTTH ENGINEERING AND INSTALLATION INTRODUCTION

LOCKOUT / TAGOUT PROGRAM

Installation Tester BENNING IT 130. Operating Manual

TT W Wireless receiver Inline Switch

COPYTRACER Anti-counterfeit registration number

ET 40 - Electrician Theory Examination Marking Schedule

Caution - leakage currents! Leakage currents in fault-current protected environments

Installation Tester BENNING IT 115. Operating Manual

25kV A.C. Electrified Lines - Traction Bonding

City and Guilds: Permitted Reference Materials (Electrotech) Version 2.3 (October 2013)

GK/GN0653. Guidance on Control of Unwanted Voltages on Telecommunications. Equipment at Stations. Rail Industry Guidance Note for GK/RT0053

, Power Industries and Communications Industry Training Board

INSTALLATION WARNING: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY

Bringing power to life. THE RCD HANDBOOK. BEAMA GUIDE TO THE SELECTION AND APPLICATION OF RESIDUAL CURRENT DEVICES (RCDs)

INTERNATIONAL STANDARD

Tech Talk (12) Down to Earth: A Discussion of the General Requirements for the Earthing of Control and Instrumentation Systems

7P Series - Surge Protection Device (SPD) Features 7P P P

QUICK SETUP GUIDE SECULIFE IP

power Knowledge The Hager Guide to current thinking on the regulations, protection and control of Klik lighting circuits.

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS

Ground Fault Isolation with Loads Fed from Separately Derived Grounded Sources

A9 R Range Family Code Internal code Poles Code Rating (A) Code Acti 9 (A9) iid R

Residual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

DPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit

Electrical Protection System Design and Operation

Circuit Analyzer MS5908A. Operation S Manual MS5908A TEST. ma VA ms Hz% 12 A 15 A 20 A HOLD ms VA. V Vd Z RCD GFCI

Single Earthed Neutral and Multi Earthed Neutral. Single Earthed Neutral and Multi Earthed Neutral: Multi Grounded Neutral System (MEN):

2014 NEC Changes Part 1

ELECTRICIAN S THEORY EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET

Earth leakage protection Response time of medium-sensitivity residual current devices

returned to your distributor for attention. 14. Do not operate the function switch while the instrument is connected to a circuit.

Siemens AG New portfolio for reliable personnel, material and fire protection

ENGINEERING STANDARD FOR INSTRUMENTS ELECTRICAL POWER SUPPLY AND DISTRIBUTION SYSTEMS FIRST EDITION MAY 2013

Earthing Guidance Notes

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

NIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A

LED Driver Constant voltage

Grounding Complications

OPERATING INSTRUCTIONS

First Draft Language

Company Directive STANDARD TECHNIQUE: SD1E/2. Technical Requirements for Customer Export Limiting Schemes

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

EurotestXE MI 3102H BT, MI 3102 BT Instruction manual Version 1.0, Code no

ELECTRICIAN S THEORY EXAMINATION 17 November 2012 QUESTION AND ANSWER BOOKLET

LED Driver Constant voltage

Analysis of transfer touch voltages in low-voltage electrical installations

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENSURING PUBLIC SAFETY THROUGH PROPER EARTHING IN LOW VOLTAGE NETWORKS

Frequently Asked Question on Isolated Power Supply(IPS)

) ,4)0,%8 $4%$#% ).4%2&!#% &/2 53%2 #,!33%3 05",)# $!4!.%47/2+3 ).4%2&!#%3. )454 Recommendation 8 INTERNATIONAL TELECOMMUNICATION UNION

UNIT Earthing and Earth Fault Current Protection (SCQF level 6)

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

(Non-legislative acts) DECISIONS

NZQA registered unit standard version 2 Page 1 of 8. Demonstrate knowledge of theory for registration of electrical installers

The RCD Handbook. BEAMA Guide to the Selection and Application of Residual Current Devices

Transcription:

CURRENT REGULATIONS BS7671 FUTURE PROPOSALS BS7671 AFFECTS YOU. A BITESIZE LOOK at RCDs and parts of the 18th edition DPC. wylexreasons.co.uk

CONTENTS. INTRODUCTION. CURRENT REGULATIONS. WHAT IT SAYS ABOUT DIVIDING THE INSTALLATION. INTRODUCTION TO 18TH DRAFT FOR PUBLIC COMMENT. FUTURE PROPOSALS. ADDITIONAL PROTECTION; SOCKET OUTLETS. ADDITIONAL PROTECTION; CIRCUITS WITH LUMINAIRES. CIRCUIT PROTECTOR (PE) CURRENTS NOT DUE TO A FAULT. TYPES OF RCD. SELECTIVITY BETWEEN RCDS. RCDS DISCONNECTING ALL LIVE CONDUCTORS. SPECIAL LOCATIONS 730.

INTRODUCTION. Current Regulations Require: Provision of additional protection (30mA RCD) on certain circuits Maintain power continuity on healthy circuits Avoid unwanted tripping of RCDs by dividing the installation into numerous circuits Make provision for safe inspection, testing and maintenance? Will the requirements change when the 18th Edition is published? This document looks at some of the proposals, within the draft 18th Edition, relating to RCDs. The trend over the past 20 years has been towards more use of RCDs i.e. on a higher number of circuits and a wider number of locations. This is likely to continue. This document looks at some of the proposals.

CURRENT REGULATIONS. WHAT IT SAYS ABOUT DIVIDING THE INSTALLATION. How can you achieve power continuity and avoid unwanted tripping of RCDs and make provision for safe inspection, testing and maintenance? Every installation should be divided into circuits so as to: Avoid danger and minimize inconvenience when there is a fault that causes protective devices to trip. The required number of individual circuits should be provided so that all healthy circuits provide power continuity and that only the individual circuit with fault is powered off.

CURRENT REGULATIONS. WHAT IT SAYS ABOUT DIVIDING THE INSTALLATION. How can you achieve additional protection, power continuity and avoid unwanted tripping of RCDs, and make provision for safe inspection, testing and maintenance? Every installation should be divided into circuits so as to: Reduce the possibility of unwanted tripping of RCDs due to excessive protective conductor currents. Cumulative currents within the protective conductor can be such that they add up to more than 50% of the rated residual operating current. This will cause the RCD to trip. Dividing equipment with PE currents over a larger number of circuits will help to avoid this risk.

CURRENT REGULATIONS. WHAT IT SAYS ABOUT DIVIDING THE INSTALLATION. How can you achieve additional protection, power continuity and avoid unwanted tripping of RCDs, and make provision for safe inspection, testing and maintenance? Every installation should be divided into circuits so as to: Account for any hazards that can arise from the failure of a circuit e.g. lighting. Lighting circuits should be individually protected by their own protective device and not share devices such as RCDs that serve groups of circuits. Grouping circuits on one 30mA RCD should be avoided.

CURRENT REGULATIONS. WHAT IT SAYS ABOUT DIVIDING THE INSTALLATION. How can you achieve additional protection, power continuity and avoid unwanted tripping of RCDs, and make provision for safe inspection, testing and maintenance? Every installation should be divided into circuits so as to: Allow safe inspection, testing and maintenance. Footnote: disconnection of all live conductors (L&N) may also be required for purposes of isolation and mechanical maintenance. The required number of individual circuits should be provided so that only the individual circuit in test or maintenance is safely powered off.

INTRODUCTION TO 18TH DRAFT FOR PUBLIC COMMENT. The 17th Edition is due to be replaced by the 18th Edition. A draft for public comment was released in 2017, comments will be considered prior to publishing the final content. The 18th Edition is due to be published in July 2018 and all installations designed after December 31st 2018 are to comply with BS7671:2018. Regulations related to division of the installation are not expected to change. The DPC of 18th Edition contained a large number of changes, and additions that considerably expanded the content of the regulations. It will be necessary for designers and installers to undertake training on these changes and additions.

18TH. ADDITIONAL PROTECTION; SOCKET OUTLETS. 30mA RCD is required for: Socket outlets rated to 20A. Mobile equipment rated to 32A and for use outdoors. 30mA RCD is required for: Socket outlets rated to 32A. Mobile equipment rated to 32A and for use outdoors. 17TH 18TH DPC This change brings extra sockets and circuits into scope for additional protection by 30mA devices, and requires designers and installers to make provision for additional devices within consumer units and distribution boards.

18TH. ADDITIONAL PROTECTION; CIRCUITS WITH LUMINAIRES. No specific mention of RCDs on luminaire circuits in domestic (household) premises. Circuits with luminaires in domestic household premises - protection by an RCD rated not more than 30mA is required. 17TH 18TH DPC This new requirement probably brings into scope circuits that were not covered by regulations group 522.6.200 (buried cables etc) and extends scope of 30mA protection to include luminaire circuits. This may require A Class RCD devices in some circumstances.

18TH. CIRCUIT PROTECTOR (PE) CURRENTS NOT DUE TO A FAULT. No specific value given for the maximum permitted (PE) circuit protector currents/earth leakage currents that are present during normal operating conditions. The accumulation of circuit protector currents/earth leakage currents that are present during normal operating conditions should not amount to more than 30% of the rated residual operating current of the RCD e.g. a PE of no more than 30% of 30mA. 17TH 18TH DPC Division of the installation into circuits with individual RCD/RCBOs may be an adopted method. Unless designers and installers are familiar with values for leakage currents (of equipment) under normal operating conditions and know that unwanted tripping will not occur.

18TH. TYPES OF RCD. No detailed explanation of the types of RCD available or how the presence of DC components can be taken into account. Different types of RCD are described e.g. type AC, type A etc. Certain criteria are also provided on device behaviour when in the presence of DC components. Designers are required to select the appropriate RCD. 17TH 18TH DPC This section is expanded considerably but the additional information on types of RCD and the references to behaviours and operating characteristics should make RCD selection easier.

18TH. SELECTIVITY BETWEEN RCDS. Where selectivity is necessary to prevent danger and required for proper functioning of the installation, manufacturers instructions shall be taken into account and the device characteristics shall be such that intended discrimination is achieved. Where selectivity is required verification shall be made either: By study By software By tests By manufacturer s declaration 17TH 18TH DPC This section is expanded considerably but the additional information on types of RCD and the references to behaviours and operating characteristics should make RCD selection easier.

18TH. RCDS DISCONNECTING ALL LIVE CONDUCTORS. In a TN system where, for certain equipment in a certain part of the installation, the requirement of 411.4.5 cannot be satisfied, that part may be protected by an RCD. An RCD shall disconnect all live conductors of the circuit protected. RCD includes RCCB, RCBO, CBR and MRCD. 17TH Footnote - disconnection of all live conductors may also be required for other purposes isolation or mechanical maintenance. See also notes for TN, TT systems & special locations. Footnote: disconnection of all live conductors may also be required for other purposes, isolation or mechanical maintenance. See also notes for TN, TT systems and special locations. These do not appear to be addressing the same point. The Draft of the18th Edition appears to require RCDs to switch the neutral conductor as well as the live phase. Some RCD products do not switch all live poles. Designers need to be aware of which do. 18TH DPC

18TH. SPECIAL LOCATIONS 730. Onshore Units - not included Regulation 730 Onshore Units of Electrical Shore Connections: Socket outlets rated to 63A shall be individually protected by a 30mA RCD. The RCD shall disconnect all live conductors, phases and neutral. 17TH 18TH DPC 730 is a new section and its content appears to follow the structure for other similar special locations. It contains similar requirements e.g. for sockets etc and that should make it reasonably straightforward to follow. However, it still needs detailed scrutiny.

Miniature RCBOs with switched neutral as standard. An easy way to comply with the requirements for dividing the installation & providing additional 30mA protection.

Note This document is not a complete summary of proposed changes/additions to the wiring regulations and until the final publication is produced the proposals may be amended by the consultation process. Readers should obtain their own copy BS7671:2018. N.B. The term RCD is mentioned over 300 times in the draft of the 18th Edition.