17TH EDITION BS TH EDITION BS7671 HOW THIS AFFECTS YOU. A BITESIZE LOOK at RCDs and parts of the 18th edition DPC. wylexreasons.co.

Similar documents
CURRENT FUTURE REGULATIONS PROPOSALS

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011

TN, TT & IT Earthing Arrangements

Automatic disconnection of lighting circuits from dimming equipment

7 o/c4 - To meet the requirements of BS 7671, all fault current protective devices without back-up protection on the supply side must be capable of:

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations. Earth Fault Loop Impedance Tests

Licensed Electricians Practical Assessment (LEP)

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented

Les Hampson Cert Ed FSCTE, Chairman CAI Technical Committee

FINAL - ER 70 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes

Module Title: Electrical Installation II Laboratory Sheet:

2394 EXAM PAPER. 1. State THREE circumstances that would require a periodic inspection and test to be carried out on an installation

Protective earthing, protective conductor and automatic disconnection in case of a fault (Fault protection)

APRIL 2017 Level 3 Advanced Technical Diploma in Electrical Installation (450) Level 3 Electrical Installation Theory Exam

ELECTRICIAN S THEORY EXAMINATION 20 November 2010 QUESTION AND ANSWER BOOKLET

Company Directive STANDARD TECHNIQUE: SD5F. Relating to connecting multiple small low voltage connections with limited network analysis

Licensed Electricians Practical Assessment (LEP)

Product Classroom. Introduction. Grounding Systems. TN system. Title. Grounding System Introduction. Date October, 2016.

ET 51 - Electrician Theory Examination Marking Schedule

Grounding and Lightning arrestors

ER 87 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) ESR 27(2) (2 marks) ESR 74A(1AA)

FINAL - IT 30 ELECTRICAL INSPECTOR EXAMINATION ANSWER SCHEDULE. Question 1 Marks Reference Marking notes. (2 marks) EA 2

ELECTRICIAN S THEORY EXAMINATION 15 November 2014 QUESTION AND ANSWER BOOKLET

MASTECH MS5908. Circuit Analyzer

NOTE: This paper relates to a closed book exam & therefore candidates should attempt this exam paper with no study-notes or text books.

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

Chapter F Protection against electric shocks

MinorWorks/Single Circuit Electrical Certificate

Company Directive STANDARD TECHNIQUE: SD5R/2. Earth Fault Loop Impedances and Phase to Neutral Loop Impedances at LV Installations

Choice of earth leakage protection devices

1. general. 1.1 electric shock. 1.2 direct and indirect contact. electric shock. indirect contact. direct contact

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations

lama M:ZSO 2SA 30oM 11ov m

Code for Design of Low Voltage Electrical Installations

INSTRUCTION MANUAL DIGITAL PSC-LOOP TESTER MODEL 4118A KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD.

Chapter F Protection against electric shocks

Chapter 6. WIRING SYSTEMS Safe Electrical Design

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

Residual Current Operated Circuit-Breakers (RCCBs)

Safety of programmable machinery and the EC directive

Residual current circuit breakers (RCCBs)

FTTH ENGINEERING AND INSTALLATION INTRODUCTION

Installation Tester BENNING IT 130. Operating Manual

, Power Industries and Communications Industry Training Board

Circuit Analyzer MS5908A. Operation S Manual MS5908A TEST. ma VA ms Hz% 12 A 15 A 20 A HOLD ms VA. V Vd Z RCD GFCI

GK/GN0653. Guidance on Control of Unwanted Voltages on Telecommunications. Equipment at Stations. Rail Industry Guidance Note for GK/RT0053

Installation Tester BENNING IT 115. Operating Manual

TS RES - OUTSTANDING ISSUES

Residual Current Operated Circuit-Breakers (RCCBs)

LOCKOUT / TAGOUT PROGRAM

Tech Talk (12) Down to Earth: A Discussion of the General Requirements for the Earthing of Control and Instrumentation Systems

TT W Wireless receiver Inline Switch

COPYTRACER Anti-counterfeit registration number

ET 40 - Electrician Theory Examination Marking Schedule

Caution - leakage currents! Leakage currents in fault-current protected environments

25kV A.C. Electrified Lines - Traction Bonding

ENGINEERING STANDARD FOR INSTRUMENTS ELECTRICAL POWER SUPPLY AND DISTRIBUTION SYSTEMS FIRST EDITION MAY 2013

City and Guilds: Permitted Reference Materials (Electrotech) Version 2.3 (October 2013)

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

INSTALLATION WARNING: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY

INTERNATIONAL STANDARD

Bringing power to life. THE RCD HANDBOOK. BEAMA GUIDE TO THE SELECTION AND APPLICATION OF RESIDUAL CURRENT DEVICES (RCDs)

Boat Dock Exposure Voltage Mitigation

Electrical Protection System Design and Operation

Earth leakage protection Response time of medium-sensitivity residual current devices

7P Series - Surge Protection Device (SPD) Features 7P P P

2014 NEC Changes Part 1

QUICK SETUP GUIDE SECULIFE IP

power Knowledge The Hager Guide to current thinking on the regulations, protection and control of Klik lighting circuits.

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS

Ground Fault Isolation with Loads Fed from Separately Derived Grounded Sources

A9 R Range Family Code Internal code Poles Code Rating (A) Code Acti 9 (A9) iid R

Grounding Complications

Residual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range

DPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit

ELECTRICIAN S THEORY EXAMINATION 17 November 2012 QUESTION AND ANSWER BOOKLET

each time the Frequency is above 51Hz. Continuous operation is required

Single Earthed Neutral and Multi Earthed Neutral. Single Earthed Neutral and Multi Earthed Neutral: Multi Grounded Neutral System (MEN):

returned to your distributor for attention. 14. Do not operate the function switch while the instrument is connected to a circuit.

EurotestXE MI 3102H BT, MI 3102 BT Instruction manual Version 1.0, Code no

ELECTRICIAN S THEORY EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET

ENSURING PUBLIC SAFETY THROUGH PROPER EARTHING IN LOW VOLTAGE NETWORKS

Siemens AG New portfolio for reliable personnel, material and fire protection

(Non-legislative acts) DECISIONS

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

Earthing Guidance Notes

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

NIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A

LED Driver Constant voltage

EurotestEASI MI 3100 SE MI 3100 s Instruction manual Version 1.1, Code no

OPERATING INSTRUCTIONS

First Draft Language

Company Directive STANDARD TECHNIQUE: SD1E/2. Technical Requirements for Customer Export Limiting Schemes

GE/GN8648. Guidance on Positioning of Lineside Telephones. Rail Industry Guidance Note for GE/RT8048

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS

MARTINDALE INSTRUCTIONS. E-ZeTest EZ2500 LOOP TESTER ELECTRIC. Trusted by professionals. Other products from Martindale:

National Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance

ETSI EN V1.2.1 ( )

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

Transcription:

BS7671 BS7671 AFFECTS YOU. A BITESIZE LOOK at RCDs and parts of the 18th edition DPC. wylexreasons.co.uk

CONTENTS. INTRODUCTION. CHAPTER 31. WHAT IT SAYS ABOUT DIVISION OF THE INSTALLATION. INTRODUCTION TO DRAFT FOR PUBLIC COMMENT.. ADDITIONAL PROTECTION; SOCKET OUTLETS.. ADDITIONAL PROTECTION; CIRCUITS WITH LUMINAIRES.. CIRCUIT PROTECTOR (PE) CURRENTS NOT DUE TO A FAULT.. TYPES OF RCD.. SELECTIVITY BETWEEN RCDS.. RCDS DISCONNECTING ALL LIVE CONDUCTORS.. SPECIAL LOCATIONS 730.

INTRODUCTION. 17th Edition Requires: Provision of additional protection (30mA RCD) Maintain power continuity Avoid unwanted tripping of RCDs Make provision for safe inspection, testing and maintenance? Will the requirements change when the 18th Edition is published? This document looks at some of the proposals, within the draft 18th Edition, relating to RCDs. The trend over the past 20 years has been towards more use of RCDs i.e. on a higher number of circuits and a wider number of locations. This is likely to continue. This document looks at some of the proposals.

CHAPTER 31. WHAT IT SAYS ABOUT DIVISION OF THE INSTALLATION. How do you achieve power continuity and avoid unwanted tripping of RCDs and make provision for safe inspection, testing and maintenance? Regulation 314.1 (i) Every installation shall be divided into circuits as necessary to: Avoid danger and minimize inconvenience in the event of a fault. The required number of individual circuits should be provided so that all healthy circuits provide power continuity and that only the individual circuit with fault is powered off.

CHAPTER 31. WHAT IT SAYS ABOUT DIVISION OF THE INSTALLATION. How do you achieve additional protection, power continuity and avoid unwanted tripping of RCDs, and make provision for safe inspection, testing and maintenance? Regulation 314.1 (iv) Every installation shall be divided into circuits as necessary to: Reduce the possibility of unwanted tripping of RCDs due to excessive protective conductor currents (not due to a fault). Cumulative currents within the protective conductor can be such that they add up to more than 50% of the rated residual operating current. This will cause the RCD to trip. Dividing equipment with PE currents over a larger number of circuits will help to avoid this risk.

CHAPTER 31. WHAT IT SAYS ABOUT DIVISION OF THE INSTALLATION. How do you achieve additional protection, power continuity and avoid unwanted tripping of RCDs, and make provision for safe inspection, testing and maintenance? Regulation 314.1 (iii) Every installation shall be divided into circuits as necessary to: Take account of hazards that may arise from the failure of a single circuit e.g. lighting. Lighting circuits should be individually protected by their own protective device and not share devices such as RCDs that serve groups of circuits. Grouping circuits on one 30mA RCD should be avoided.

CHAPTER 31. WHAT IT SAYS ABOUT DIVISION OF THE INSTALLATION. How do you achieve additional protection, power continuity and avoid unwanted tripping of RCDs, and make provision for safe inspection, testing and maintenance? Regulation 314.1 (ii) Every installation shall be divided into circuits as necessary to: Facilitate safe inspection, testing and maintenance. Footnote: disconnection of all live conductors (L&N) may also be required for purposes of isolation and mechanical maintenance. The required number of individual circuits should be provided so that only the individual circuit in test or maintenance is safely powered off.

INTRODUCTION TO DRAFT FOR PUBLIC COMMENT. The 17th Edition is due to be replaced by the 18th Edition. A draft for public comment was released in 2017, comments will be considered prior to publishing the final content. The 18th Edition is due to be published in July 2018 and all installations designed after December 31st 2018 are to comply with BS7671:2018. However, earlier adoption of the new regulations is not precluded. Regulation 314 (Division of Installation) is maintained. The DPC of 18th Edition contained a large number of changes, and additions that considerably expanded the content of the regulations. It will be necessary for designers and installers to undertake training on these changes and additions.

. ADDITIONAL PROTECTION; SOCKET OUTLETS. Chapter 41 Additional protection by means of a 30mA RCD is required for: Socket outlets rated to 20A. Mobile equipment rated to 32A and for use outdoors. Chapter 41 Additional protection by means of a 30mA RCD is required for: Socket outlets rated to 32A. Mobile equipment rated to 32A and for use outdoors. This change brings extra sockets and circuits into scope for additional protection by 30mA devices, and requires designers and installers to make provision for additional devices within consumer units and distribution boards.

. ADDITIONAL PROTECTION; CIRCUITS WITH LUMINAIRES. Chapter 41 No specific mention of RCDs on luminaire circuits in domestic (household) premises. Chapter 41 Additional requirements for circuits with luminaires in domestic household premises, requiring additional protection by an RCD rated not more than 30mA for circuits supplying luminaires. This new requirement probably brings into scope circuits that were not covered by regulations group 522.6.200 (buried cables etc) and extends scope of 30mA protection to include luminaire circuits. This may require A Class RCD devices in some circumstances.

. CIRCUIT PROTECTOR (PE) CURRENTS NOT DUE TO A FAULT. Regulation 314 Division of the installation (Chapter 31) requires designers to reduce the possibility of unwanted tripping of RCDs due to excessive protective conductor (PE) currents, not due to a fault. But gives no values for PE currents. Regulation 531 Section 531 cross references with 314 and includes specific values for PE currents, and division of the installation still requires designers to reduce the possibility of unwanted tripping of RCDs due to excessive protective conductor currents. Extending the good practice of dividing the installation into a larger number of sub circuits as required to fully meet all 6 criteria listed in 314 may cater for these new requirements that are explained further on the next page.

. CIRCUIT PROTECTOR (PE) CURRENTS NOT DUE TO A FAULT. Regulation 531 No specific value given for the maximum permitted (PE) circuit protector currents/earth leakage currents that are present during normal operating conditions. Regulation 531 The accumulation of circuit protector currents/earth leakage currents that are present during normal operating conditions shall not be more than 30% of the rated residual operating current of the RCD e.g. a PE of no more than 30% of 30mA. Division of the installation into circuits with individual RCD/RCBOs may be an adopted method. Unless designers and installers are familiar with values for leakage currents (of equipment) under normal operating conditions and know that unwanted tripping will not occur.

. TYPES OF RCD. Regulation 531 No detailed explanation of the types of RCD available or how the presence of DC components can be taken into account. Regulation 531 Different types of RCD are described e.g. type AC, type A etc. Certain criteria are also provided on device behaviour when in the presence of DC components. Designers are required to select the appropriate RCD. This section is expanded considerably but the additional information on types of RCD and the references to behaviours and operating characteristics should make RCD selection easier.

. SELECTIVITY BETWEEN RCDS. Regulation 536 Where selectivity is necessary to prevent danger and required for proper functioning of the installation, manufacturers instructions shall be taken into account and the device characteristics shall be such that intended discrimination is achieved. Regulation 536 Where selectivity is required verification shall be made either: By desk study By software tools By tests to the applicable product standard By manufacturer s declaration This section is expanded considerably but the additional information on types of RCD and the references to behaviours and operating characteristics should make RCD selection easier.

. RCDS DISCONNECTING ALL LIVE CONDUCTORS. Regulation 531 In a TN system where, for certain equipment in a certain part of the installation, the requirement of 411.4.5 cannot be satisfied, that part may be protected by an RCD. Regulation 531 An RCD shall disconnect all live conductors of the circuit protected. Definitions RCD includes such devices as RCCB, RCBO, CBR and MRCD. Footnote: disconnection of all live conductors may also be required for other purposes, isolation or mechanical maintenance. See also notes for TN, TT systems and special locations. Footnote - disconnection of all live conductors may also be required for other purposes isolation or mechanical maintenance. See also notes for TN, TT systems & special locations. These do not appear to be addressing the same point. The Draft of the18th Edition appears to require RCDs to switch the neutral conductor as well as the live phase. Some RCD products do not switch all live poles. Designers need to be aware of which do.

. SPECIAL LOCATIONS 730. Regulation 730 730 does not appear in the 17th Edition but a number of similar applications do e.g. Marinas. Regulation 730 Onshore Units of Electrical Shore Connections: Socket outlets rated to 63A shall be individually protected by a 30mA RCD. The RCD shall disconnect all live conductors, phases and neutral. 730 is a new section and its content appears to follow the structure for other similar special locations. It contains similar requirements e.g. for sockets etc and that should make it reasonably straightforward to follow. However, it still needs detailed scrutiny.

Miniature RCBOs with switched neutral as standard.

Note This document is not a complete summary of proposed changes/additions to the wiring regulations and until the final publication is produced the proposals may be amended by the consultation process. Readers should obtain their own copy BS7671:2018. N.B. The term RCD is mentioned over 300 times in the draft of the 18th Edition.