Original operating instructions Fail-safe inductive sensor GM705S

Similar documents
Original operating instructions Fail-safe inductive sensor GG507S

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Operating instructions Contrast sensor O5K / / 2016

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2018

PROXIMITY SENSOR TERMINOLOGY

Proximity Sensor Terminology

Installation Instructions RF-identification system Read/write head DTM434 DTM435 DTM436 DTM437

Installation Instructions RF identification system Read/write head ANT430 ANT431

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2009

Operating instructions Fail-safe delay timer AZS About this document. Content

Operating instructions Diffuse reflection sensor with background suppression. OJ51xx laser / / 2010

Installation Instructions RF-identification system Read/write head ANT513

SAFETY LIGHT CURTAINS

Installation instructions SmartController XL CR / / 2014

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Operating instructions Measured signal converter for temperature sensors. TP323x / / 2010

Operating instructions Measured signal converter for temperature sensors TP / / 2010

Operating Instructions

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Operating instructions Electronic level sensor LK / / 2008

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Instruction manual for STA 1 sectional door operator

Instruction manual for STA 1 sectional door operator

Datasheet - PROTECT-IE-02

Operating instructions. Electronic pressure sensor PY2068 ENGLISH

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

Order/Technical Support Tel: (800) / FAX: (800) /

Lexium integrated drives

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

Operating instructions. Combined pressure sensor PN /00 11/03

Installation instructions for encoders. RM3xxx RM7xxx RN3xxx RN7xxx /02 08/2015

QUINT-PS-24DC/24DC/10

Online data sheet UE43-3AR3D2 UE43-3AR SAFETY RELAYS

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

MINI-PS AC/24DC/1.3

Product Information ECI 1319S EQI 1331S. Absolute Rotary Encoders without Integral Bearing and with DRIVE-CLiQ Interface.

Type CP-S, CP-C & CP-A Switch mode

Tube Facing Tool.

Inductive sensor slot-type SI2-K08-AP7

Installation instructions BasicController CR0401 CR / / 2012

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

Online data sheet UE48-3OS2D2 UE48-3OS SAFETY RELAYS

QUINT-PS/ 3AC/24DC/10

Operating instructions. RFID UHF antennas Low range / ultra-low range Mid range / short mid range Wide range

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

Installation Instructions Electronic pressure sensor. PTD25-10-xxxxx PTD25-20-xxxxx

Operating instructions Magnetic-inductive flow meter SM6050 SM7050 SM / / 2016

Operating instructions Magnetic-inductive flow meter FMM FMM FMM

PHOTOELECTRIC SENSORS. Online data sheet

Electronic timer CT-TGD.22

QUINT-PS AC/24DC/40

PHOENIX CONTACT - 09/2009

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

User and Safety Manual ProLine P224xx P1

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Online data sheet UE48-2OS2D2 UE48-2OS SAFETY RELAYS

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

QUINT-PS/ 3AC/24DC/40

Optical laser distance sensors. Dimensioned drawing

Magnetic Inductive Flow Sensor induq

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

Power supply CP-D 24/1.3

New Products Catalogue 2009 Safety Relays ESR5

MINI-PS AC/2X15DC/1

Distance-setting Photoelectric Sensor

Miniature resistance thermometer Model TR33, thread-mounted

Power supply CP-D 24/4.2 Primary switch mode power supply

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

1000 SERIES INSTALLATION SUPPLEMENT Rev. 7/1/10

Safety light curtain to safeguard the hinge edge IMPORTANT NOTE

Power supply CP-E 24/0.75

Operating instructions. RFID UHF reader DTE800 DTE810 DTE900 DTE910 DTE / / 2017

T22. Torque transducer. Special features. Data sheet

Cylindrical Photoelectric Sensor

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

3B SCIENTIFIC PHYSICS

1000 SERIES INSTALLATION SUPPLEMENT Rev

Inductive Proximity Detectors Technical Guide

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

REV-201М OPERATING MANUAL MULTIFUNCTIONAL TWO-CHANNEL TIME DELAY RELAY. «NOVATEK-ELECTRO» Ltd Intelligent industrial electronics

Laser contrast scanner. Dimensioned drawing

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Antenna Splitter ASA 1. Instruction manual

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

QL55 Series Luminescence Sensor

SINEAX B 811 Power Pack with additional Functions

NA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects

Power supply CP-D 12/2.1

Transcription:

Original operating instructions Fail-safe inductive sensor GM705S 80236832 / 00 09 / 2016

Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related requirements regarding the application...4 3 Items supplied...5 4 Functions and features...5 5 Function...6 5.1 Enable zone...6 5.2 Protection against simple defeating...7 6 Installation...8 6.1 Alignment of the sensing face...8 6.2 Installation conditions...8 7 Electrical connection...10 8 Set-up...10 8.1 Setting aid...10 8.2 Determine the enable zone...10 8.3 Deactivate setting aid... 11 9 Operation...12 9.1 Switching state of the outputs...12 9.1.1 The safe state...12 9.1.2 The switched state...12 9.1.3 Output characteristics...12 9.1.4 Cross faults...12 9.2 Operating mode...13 9.2.1 Delayed switching of the LED...13 9.2.2 Switching of the LED without delay...14 9.3 Response times...14 9.4 LED display...16 10 Technical data...17 11 Troubleshooting...19 2

12 Maintenance, repair and disposal...19 13 Terms and abbreviations...20 1 Preliminary note The instructions are part of the unit. They are intended for authorised persons according to the EMC, Low Voltage and Machinery Directives and safety regulations. The instructions contain information about the correct handling of the product. Read the instructions before use to familiarise yourself with operating conditions, installation and operation. Follow the safety instructions. 1.1 Symbols used Instructions Cross-reference Important note Non-compliance can result in malfunction or interference. Information Supplementary note. LED on LED off LED flashes (2 Hz) LED flashes quickly (5 Hz) 1.2 Warning signs used WARNING Warning of serious personal injury. Death or serious irreversible injuries may result. 3

2 Safety instructions Follow the operating instructions. Improper use may result in malfunctions of the unit. This can lead to personal injury and/or damage to property during operation of the machine. For this reason note all remarks on installation and handling given in this document. Also adhere to the safety instructions for the operation of the whole installation. In case of non-observance of notes or standards, especially when tampering with and/or modifying the unit, any liability and warranty is excluded. If the sensor is damaged, the safety function cannot be guaranteed. Errors caused by damage cannot be detected by the sensor. The unit must be installed, connected and put into operation by a qualified electrician trained in safety technology. The applicable technical standards for the corresponding application must be complied with. For installation the requirements according to EN 60204 must be observed. In case of malfunction of the unit please contact the manufacturer. Tampering with the unit is not allowed. Disconnect the unit externally before handling it. Also disconnect any independently supplied relay load circuits. After installation, maintenance or repair of the system perform a complete function check. Use the unit only in specified environmental conditions ( 10 Technical data). In case of special operating conditions please contact the manufacturer. Use only as described below ( 4). 2.1 Safety-related requirements regarding the application It must be ensured that the safety requirements of the respective application correspond to the requirements stated in these instructions. 4

WARNING Failure of the safety function When used outside of the defined environmental conditions, the safety-related function of the sensor cannot be guaranteed. Use only in accordance with the defined environmental conditions ( 10 Technical data). Use of the sensor in the vicinity of chemical and biological media (solid, liquid, gaseous) as well as ionising radiation is not permitted. Observe the following requirements: Take measures to avoid metallic objects being placed on the sensing face unintentionally. Adhere to EN 14119 for interlocking devices associated with guards. Adhere to the principle of normally closed operation for all external safety circuits connected to the system. In case of faults within the fail-safe sensor which result in the defined safe state: take measures to maintain the safe state when the complete control system continues to be operated. Replace damaged units. 3 Items supplied 1 fail-safe sensor GM705S with premounted angle bracket, 1 Allen key for fixing the fail-safe sensor onto the angle bracket 1 original operating instructions GM705S, ident no. 80236832. If one of the above-mentioned components is missing or damaged, please contact one of the ifm branch offices. 4 Functions and features The fail-safe inductive sensor GM705S detects metal without contact. Safety function SF: the safe state (output stage switched off; logic "0") is achieved when undamping greater than or equal to the safe switch-off distance s ar. ( 10 Technical data). Also observe the notes on installation of the sensor ( 6 Installation). 5

The fail-safe inductive sensor is a proximity device with defined behaviour under fault conditions (PDDB) to IEC 60947-5-3. The fail-safe sensor conforms to Performance Level e according to EN ISO 13849-1 as well as to the requirements SIL 3 to IEC 61508 and meets SILcl 3 to IEC 62061. The unit corresponds to the classification I2C40SP2 to IEC 60947-5-2 for nonflush installation ( 6 Installation). The fail-safe inductive sensor has been certified by TÜVNord. 5 Function "1" "0" 1: dual LED: signal (yellow); power (green) 2: close zone 3: enable zone 4: safe switch-off distance s ar 5: target 5.1 Enable zone The outputs (OSSD) are only enabled when a damping target is present in the enable zone. Outside this enable zone the outputs remain switched off. The safe switch-off distance s ar is > 45 mm. The enable zone is different if damping elements which deviate from the standard target plate in terms of material, form and size are used. Enable zone for selected materials*: Material FE360 (= mild steel) Stainless steel Enable zone 4...20 mm 2.0...17.6 mm 6

Material AIMg3G22 AI 99 % CuZn37 Copper Enable zone 0...9.6 mm 0...8.6 mm 0...10.0 mm 0...7.0 mm * Typical values for damping with a reference target of 60 x 60 x 1 mm and non-flush installation to IEC 60947-5-2 at an ambient temperature of 20 C. Depending on the characteristics of the damping element there may be no close zone. 5.2 Protection against simple defeating The fail-safe sensor reacts to metal objects, e.g. the frame of a safety door. Other metal objects that are not intended to enable the sensor must not be allowed to enable the fail-safe sensor unintentionally. Take measures to prevent metal objects, except the designated target, from being placed on the sensing face or in the enable zone unintentionally. In addition, the sensor has the following switching characteristics to make simple defeating of its safety function more difficult: 1. By slowly introducing a metallic object into the enable zone, the outputs are immediately switched, but displayed by the LED with a delay of approx. 3 s ( 9.2.1 Delayed switching of the LED). By doing so, the object is generally in the close range before the LED indication is lit. The technical instructions concerning the restart of the installation must be observed. 2. If the object remains in the close zone for over approx. 2 s, the outputs are completely disabled and no longer enabled in case of damping in the enable zone. If the object stays in the close range for longer than approx. 5 s, the setting aid is activated ( 8.1). Release of the enable zone can be carried out either by undamping (> 45 mm) for a time of more than 2 s or by a voltage interruption ( 8.3 Deactivate setting aid). 7

6 Installation 6.1 Alignment of the sensing face 1 2 3 4 The socket is rotatable: 5 6 7 Tighten the socket according to the manufacturer's indications. Observe the tightening torque for the ifm socket (e.g. EVxxxx: 0.6...1.5 Nm). 6.2 Installation conditions The unit is non-flush mountable according to IEC 60947-5-2, type I2C40SP2. 8 Flush installation of the fail-safe sensor is not permitted since this can result in an increase of the sensing range up to enabling of the outputs (OSSDs).

Ensure the unit cannot work loose. Tighten captive screws with 1 Nm. Limit the use of oblong holes to the initial setting. Adhere to the installation conditions in accordance with the figures 1 to 5: 1 3 80 280 105 2 20 80 80 Angle mounting Channel mounting 4 5 80 80 80 80 80 9

7 Electrical connection Wiring diagram 10 Technical data Disconnect power. Also disconnect any independently supplied relay load circuits. Supply voltage: connect L+ to pin 1 and L- to pin 3 of the connector. The nominal voltage is 24 V DC. This voltage may vary between 19.2 V and 30 V incl. 5 % residual ripple to EN 61131-2. A safe industrial power supply with overvoltage protection must be used. In case of a fault, 42 V AC / 60 V DC must not be exceeded. 8 Set-up 8.1 Setting aid For easy and reliable installation the sensor features an optical setting aid to visualise the enable zone. The setting aid is activated by placing a metal object in front of the fail-safe sensor (close range). 0 1: close zone 2: enable zone > 5 s 45 mm 8.2 Determine the enable zone After approx. 5 s the yellow LED starts to flash: the setting aid is active. While this mode is active, the output remains in the safe state ("0"). When the setting aid is active, the enable zone can be determined by moving the target (or the sensor if the target is fixed). 10

0 45 mm As soon as the target enters the enable zone, the yellow LED goes out. If the target is just outside the enable zone in either direction the LED starts to flash again. 1: close zone 2: enable zone 8.3 Deactivate setting aid If the sensor is undamped for more than 2 s (> 45 mm), the setting aid is switched off and the yellow LED goes out. 0 45 mm This can also be achieved by power off. < 2 s > 2 s 1: close zone 2: enable zone 11

9 Operation 9.1 Switching state of the outputs 9.1.1 The safe state The safe state is when at least one of the outputs A1 or A2 (OSSDs) is switched off (zero-current state: logic "0"). If one of the outputs A1 or A2 is switched off, the subsequent safety-related logic unit must bring the complete system into the state defined as safe. 9.1.2 The switched state If the damping element is in the enable zone and if there is no sensor error, both outputs A1 and A2 (OSSDs) are enabled (logic "1"). 9.1.3 Output characteristics The output characteristics are compatible with the input characteristics to EN 61131-2 type 1 or 2: Logic "1" 15 V 2...15 ma 11 V 15...30 ma Logic "0" 5 V leakage current 0.2 ma *) *) pull-down current typ. 30 ma The interface corresponds to interface type C class 0 according to the ZVEI position paper "Klassifizierung binärer 24-V-Schnittstellen mit Testung im Bereich der Funktionalen Sicherheit" (Classification of binary 24V interfaces tested with regard to functional safety). 9.1.4 Cross faults A cross fault between both outputs (A1 and A2) is detected by the fail-safe sensor and results in the outputs (OSSD) being switched off at the next safety request. The outputs A1 and A2 remain switched off until the error has been removed. A cross fault between one of the two outputs (A1 or A2) and the supply voltage leads to switching off the other output (A2 or A1) in case of a safety request. 12

9.2 Operating mode The length of the preceding undamping determines whether the yellow LED comes on with a delay ( 9.2.1) or without delay ( 9.2.2) when a target moves into the enable zone. In any case, the outputs switch on without delay. In case of undamping the outputs switch off and the yellow LED goes out without delay. In case of damping in the close range the outputs switch off immediately whereas the yellow LED goes out with a delay of approx. 2 s. When the LED goes out the outputs are maintained in the safe state ("0"). Thus, switching on again in the enable zone is not possible. Enabling is done by undamping (> 45 mm) of more than 2 s or by interrupting the voltage ( 5.2 Protection against simple defeating). 9.2.1 Delayed switching of the LED Undamping > 2 s: 0 45 mm > 3 s If the target was away from the sensor for more than approx. 2 s (> 45 mm), the yellow LED goes on with a delay of approx. 3 s in case of damping in the enable zone. This is also the case if the target is in the enable zone when the voltage is switched on. 1: close zone 2: enable zone 13

9.2.2 Switching of the LED without delay Undamping < 2 s: If the target was away from the sensor for less than 2 s (> 45 mm), the yellow LED comes on without delay in case of damping in the enable zone. 0 0 s *) 45 mm 1: close zone 2: enable zone *) except for the first start-up 9.3 Response times Response time on safety request (removal from the enable zone) Response time when approaching the close range (non safetyrelated zone) Response time when approaching the enable zone (enable time) Risk time / response time for safety-related faults Permissible dwell time in the close range Delay time to activate the setting aid ( 8.1) Dwell time in the undamped condition ( 45 mm) to return into the operating mode ( 8.3 Deactivate setting aid) Simultaneity of switching on and off of the outputs in case of a safety request Test pulse duration t i_max on A1/A2(1) Test pulse interval T p (2) [pulse package] 50 ms 100 ms typ. 100 ms 200 ms 100 ms approx. 2 s approx. 5 s approx. 2 s 50 ms max. 1 ms min. 2 ms max. 5 ms 14

1 0 t 1 0 t 1: Test pulse duration 2: Test pulse interval T p (pulse package) 3: Test pulse interval T Test pulse interval T (repetition pulse package) min. 30 ms max. 50 ms 15

9.4 LED display LED Operating status Outputs A1 (OSSD) A2 (OSSD) No voltage supply Both outputs switched off 0 0 Undervoltage 0 0 Overvoltage Both outputs switched off 0 0 Taget outside the enable zone (operating mode) or in the enable zone (setting aid) Target in the enable zone (operating mode) Target outside the enable zone (setting aid) Both outputs switched off 0 0 Both outputs enabled 1 1 Both outputs switched off 0 0 Internal or external fault ( 11 Troubleshooting) 0 0 1 0 1 0 16

10 Technical data GIMC-4045-US/2OSSD Inductive sensors Product characteristics Fail-safe inductive sensor Rectangular, plastics M12 connector Enable zone 4...20 mm; [nf] non-flush mountable Complies with the requirements: EN ISO 13849-1: 2015 category 4 PL e IEC 61508: SIL 3 IEC 62061: SILcl 3 Application Type of operation Electrical data Electrical design continuous operation (maintenance-free) DC PNP Operating voltage [V] 24 DC (19.2...30 DC) Rated insulation voltage [V] 30 Current consumption [ma] < 30 Protection class Reverse polarity protection Outputs Output function 2 x OSSD (A1 and A2) Output data Interface type C class 0 Output voltage at 24 V compatible with EN 61131-2 inputs type 1, 2, 3 Voltage drop Short-circuit protection [V] < 2.5; (100 ma) yes Max. capacitive load CL_max [nf] 20 III yes 17

Range Enable zone [mm] 4...20 Safe switching off distance s(ar) [mm] 45 Reaction times -on delay time [s] 5 Response time to safety request [ms] 50 Response time when approaching [ms] the enable zone (enable time) 200 Risk time (response time for safety [ms] -related faults) 100 Environment Applications Class C to EN 60654-1 weatherproof application Ambient temperature [ C] -25...60, for service life 87600 h 10...40, for service life 175200 h Rate of temperature change [K/min] 0.5 Max. relative air humidity [%] 5...95, briefly 5...70, permanently Air pressure [kpa] 80...106 Height above sea level [m] 2000 Ionising radiation not permissible Salt spray no Protection IP 65 / IP 67 Tests / approvals EMC IEC 60947-5-2 IEC 60947-5-3 EN 60947-5-2 EN 61000-4-2 ESD: 6 kv CD / 8 kv AD EN 61000-4-3 HF radiated: 20 V/m EN 61000-4-4 Burst: 2 kv EN 61000-4-6 HF conducted: 10 V EN 61000-4-8: 30 A/m EN 55011: class B Shock resistance IEC 60947-5-2 Vibration resistance IEC 60947-5-2 Safety classification Mission time TM [h] 175200, (20 years) Safety-related reliability PFHd [1/h] 2.5E-09 Mechanical data Mounting non-flush mountable Housing materials PPE; diecast zinc Weight [kg] 0.355 Displays / operating elements Display Electrical connection Connection LED yellow (signal), LED green (power) M12 connector; Gold-plated contacts ifm electronic gmbh Friedrichstraße 1 45128 Essen We reserve the right to make technical alterations without prior notice. GB GM705S-03 25.05.2016 18

Wiring 1: Safety-related logic unit Remarks Remarks Unless stated otherwise, all data refer to the 60x60x1 mm reference target plate to IEC 60947-5-2 (FE360 = mild steel) over the whole temperature range. Pack quantity [piece] 1 ifm electronic gmbh Friedrichstraße 1 45128 Essen We reserve the right to make technical alterations without prior notice. GB GM705S-03 25.05.2016 11 Troubleshooting LED display 9.4 Problem Possible cause Troubleshooting No LED display No voltage supply Apply voltage LED flashes and sensor does not switch Sensor does not switch, not even after undamping and redamping Undervoltage Overvoltage Sensor was brought into the safe state (logic "0"). Cause: cross fault between both outputs A1 and A2 cross fault between one output (A1 or A2) and the supply voltage error in the sensor detected Correct the voltage ( 10 Technical data) Switch the operating voltage off and on again Check wiring and connections Check external electronics (e.g. PLC) Remove the cross fault Replace the unit 12 Maintenance, repair and disposal If used correctly, no maintenance and repair measures are necessary. Only the manufacturer is allowed to repair the unit. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. 19

13 Terms and abbreviations OSSD Output Switch Device PDDB PFH (PFH D ) Proximity devices with defined behaviour under fault conditions Probability of (dangerous) Failure per Hour PL Performance Level PL to EN ISO 13849-1 SIL Safety Integrity Level SIL 1-4 to IEC 61508. The higher the SIL, the lower the probability that a safety function will fail. SIL cl Safety Integrity Level claim limit According to IEC 62061 T M Mission time Lifetime to EN 60947-5-3 (= max. service life) 20

21