Automatic Monitoring and Controlling of Distribution Transformer using Power Line Communication

Similar documents
Automatic Load Sharing of Transformers using Microcontroller

DISTRIBUTION TRANSFORMER MONITORING AND CONTROL SYSTEM FOR REMOTE ELECTRIC POWER GRIDS THROUGH GSM

High Impedance Fault Detection and Location in a Power Transmission Line Using ZIGBEE

Design and Implementation of Loss Reduction of Transmission and Distribution Line Using GSM Technology and ZIGBEE

Monitoring and Protection of Distribution Transformer Using GSM Module Jenifer A 1, Bharathi B R 2, Shanthi Mounika B 3

Monitoring the Transformer Oil Temperature and Load Sharing Using Gsm

GPS and GSM Based Transmission Line Monitoring System with Fault Detection Introduction:

WIRELESS THREE PHASE LINE FAULT MONITORING

Power Line Carrier Communication Based Data Transmission for Tele-Operation of Devices

GSM BASED TRANSFORMER HEALTH MONITORING SYSTEM

AUTOMATED WATER METER READING

International Journal for Research in Applied Science & Engineering Technology (IJRASET) DTMF Based Robot for Security Applications

Mobile Agent Based Intelligence Power Distribution Control System

Remote controlled Waiter Robot for Restaurant Automation

Universal Protection System for Ac Industrial Motors

Fig.1. LCD panel on the loco indicating fault. Keywords data capturing, filtering, RS422, RS232, GSM SIM900, sensors.

Automated Mobility and Orientation System for Blind

Feeder Protection From Over Load and Earth Fault Relay

MONITORING OF DISTRIBUTION TRANSFORMER PARAMETERS USING PLC

Electrical Equipment Condition Assessment

Energy Meter Tempering and Power Tapping Detection System for Effective Power Theft Control

AUTOBOOK The Messaging Machines (Using GSM and Arduino)

Real-time Visualization, Monitoring and Controlling of Electrical Distribution System using MATLAB

ARM BASED DISTRIBUTED ELECTRICITY MONITORING AND CONTROL USING GSM MODEM

Wireless Sensor Network for Intra-Venous Fluid Level Indicator Application

Design and Implementation of Integrated Smart Township

ARTIFICIAL INTELLIGENCE BASED SELF PROTECTION DEVICE FOR WOMEN PROJECT REFERENCE NO: 38S0037

International Journal of Engineering Research ISSN: & Management Technology March-2016 Volume 3, Issue-2

Prashant Sangulagi Assistant Professor, E&CE Dept. BKIT Bhalki, INDIA

DESIGN OF A DEVICE FOR CHECKING THE CONTINUITY IN ELECTRICAL CIRCUIT

Modern Electricity Billing System and Fuse Detection Using GSM

Automatic USB Controlled Power Switch

RFID- GSM- GPS Imparted School Bus Transportation Management System

GREEN RADIO: ENERGY EFFICIENT MOBILE TOWER NETWORK COMMUNICATION

ELECTRICITY BILLING BY USING POWER LINE CARRIER COMMUNCIATION

International Journal of Advance Engineering and Research Development ADVANCED NAVIGATOR AND MONITORING SYSTEM FOR FISHERMAN

Design And Application Of A Control System For DC Motors Over Power Line

ARTIFICIAL ROBOT NAVIGATION BASED ON GESTURE AND SPEECH RECOGNITION

INTELLIGENCE HOME AUTOMATION SYSTEM USING LDR

Automatic Transfer Switch (ATS) Using Programmable Logic Controller (PLC)

IMPLEMENTATION OF EMBEDDED SYSTEM FOR INDUSTRIAL AUTOMATION

Transient Detection in Industrial Grids and Compensation Using FCL DVR

sdevelopment OF COAL MINE SAFETY SYSTEM USING WIRELESS SENSOR NETWORKS

Smart Monitoring and Power Factor Correction of Distribution Transformer using IOT

Prototype Model of Li-Fi Technology using Visible Light Communication

sensors ISSN

Automatic Gadget Control System Using Arduino And PIR Sensor

Automatic EB Billing Using GSM Technique

Charles Kim, Ph.D. Department of Electrical and Computer Engineering Howard University Washington, DC

Management of Home Appliances with Variation in Environment Aisha Jilani, Sahar Sultan, Intesar Ahmed and Sajjad Rabbani


GSM Based Automatic Wireless Energy Meter Reading System P. Harish M.Tech, S. Sandeep M.Tech,

Design of WSN for Environmental Monitoring Using IoT Application

XBee based Remote-Controllable and Energy-Saving Room Architecture

International Journal of Modern Trends in Engineering and Research GSM based fault alert system for BTS (Mobile tower)

Keyword: - GSM kit, Transformer, sensors, rectifier, microcontroller, power supply, LCD.. Vol-3 Issue INTRODUCTION

UPGRADING SUBSTATION RELAYS TO DIGITAL RECLOSERS AND THEIR COORDINATION WITH SECTIONALIZERS

Power Theft Identification system using Power Line Carrier Communication (PLCC) technique in Distribution system based on Binary Search Algorithm

HIGH POWER TRANSMITTER MONITORING & CONTROL USING GSM

International Journal of Current Research and Modern Education (IJCRME) ISSN (Online): & Impact Factor: Special Issue, NCFTCCPS -

Hardware Implementation of an Explorer Bot Using XBEE & GSM Technology

Single Line Diagram of Substations

Microcontroller Based Three Phase Fault Analysis for Temporary and Permanent Fault

Implementation of Smart Home System Using Wireless Technology

Substation Monitoring System

DISTRIBUTION LINE FAULT DETECTION AND INTIMATION USING GSM

Design and Implementation of High Precision Automated Online Monitoring of Distribution Transformer (OMDT) Device

DESIGN AND SIMULATION OF WIDE AREA MONITORING WITH SMART GRIDS USING PHASOR MEASUREMENT UNIT WITH DISTRIBUTED GENERATION

Director General Engineering, Planning and Standards Branch (JETN, Room 1943B) Industry Canada 235 Queen Street, Ottawa, Ontario, K1A 0H5

ELECTRICITY THEFT MONITORING AND ITS CONSUMPTION SAVINGS

Design and Development of Pre-paid electricity billing using Raspberry Pi2

Power Line Communication Based Fault Monitoring And Control

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

Implementation of a Self-Driven Robot for Remote Surveillance

AUTOMATIC ELECTRICITY METER READING AND REPORTING SYSTEM

Charge Pump Phase Locked Loop Synchronization Technique in Grid Connected Solar Photovoltaic Systems

Transformer Protection by Using Arduino with GSM Modem

ECET 211 Electric Machines & Controls Lecture 3-1 (Part 1 of 2) Motor Transformers and Distribution Systems

M.Sinduja,S.Ranjitha. Department of Electrical & Electronics Engineering, Bharathiyar Institute of Engineering For Women, Deviyakurichi.

GSM Based Automated Embedded System for Monitoring and Controlling of Smart Grid

A novel autonomous monitoring system for distributed leakage current measurements on outdoor high voltage insulators

International Journal of Advance Engineering and Research Development. UART implementation using FPGA with configurable baudrate

Large-Area Time-of-Flight System for STAR

Multiple Target Tracking For Indoor Environment Using WPIR

POWER PLANT PARAMETER MONITORING ANDCONTROLLING SYSTEM BASED ON WIRELESS TECHNOLOGY

Design and Implementation of Modern Digital Controller for DC-DC Converters

EMI DUE AND ALCOHOL DETECTION BASED AUTOMATIC VEHICLE LOCKING SYSTEM

COMMUNICATION THROUGH POWER LINES

3D ULTRASONIC STICK FOR BLIND

LOAD SHARING OF TRANSFORMERS BASED ON MICROCONTROLLER

AMBULANCE TRACKING AND ALTERNATE ROUTING

International Research Journal in Advanced Engineering and Technology (IRJAET)

GSM Based Water Billing System

M.Tech: Industrial Automation & Robotics The National Institute of Engineering, Mysore-08. (Established in 1946) Department of Mechanical Engineering

Security Management System for Oilfield Using GSM & Zigbee Communication

An Optical Version of WIFI for Indoor Application

Simulation Of Radar With Ultrasonic Sensors

Wireless Energy Meter Using Handheld Reader

ROM/UDF CPU I/O I/O I/O RAM

A Scheme for the Application of Smart Message Language in a Wireless Meter Reading System

Transcription:

Automatic Monitoring and Controlling of Distribution Transformer using Power Line Communication Harshitha Keshav1, Dr. B. Yogesha2 1PG student of ME Dept., Malnad College of Engineering. 2Professor of ME Dept., Malnad College of Engineering. Abstract The load monitoring and protection of distribution transformers are vital element of the power distribution infrastructure, they should be observed habitually to keep any potential shortcomings. Failure in transformer can without much of a stretch expense from a few thousands to lakhs of rupees to either repair or supplant, and will likewise bring about a loss of service to client's until the manifestations is discovered and repaired. This paper work portrays the mechanization of the transformer utilizing ARM 7 microcontroller. Different parameters for example, temperature, current, and voltage, oil level of the transformer, over load and short circuit conditions are observed. Indeed, even the sparkle around the transformer will be identified. The power line modem uses the power line cable as communication medium. All the information will be correspondence through the existing PLC (Power Line Communication) which provides a communicating medium. In case of any abnormal condition the buzzer will beep indicating faulty condition and causes the microcontroller to trip the relay and disconnect the load automatically. Consequently the transformer is shielded from serious harm and makes the distribution more strong, solid, and precise and spares enormous economic misfortunes. This framework can supplant existing physically checking of the transformer. In this paper Keil µvision4 software is used to code the microcontroller for controlling and monitoring the system. Index Terms ARM7, Sensors, GSM, GPS I. INTRODUCTION A distribution transformer is a transformer that gives the last voltage change in the energy conveyance system, going down the voltage utilized within conveyance offering of the level utilized toward those clients. Distribution transformers are a standout amongst the most imperative hardware in power system, due to the substantial number of transformers circulated more than a wide range in power frameworks. The information procurement and condition observing of distribution transformer is a vital issue, since it is a necessary piece of substation, strategic bottle necks happen in the event if we neglect to screen the transformer. A few parameters of the transformer operation are level of oil, electrical burden levels, voltage and current level and temperature variety. This work demonstrates the continuous observing and control of framework utilizing sensors for perusing the estimation of diverse parameters of distribution transformers. In this paper the voltage, current, temperature and oil level as the parameters to be checked as the transformer demonstrates its top affectability also the short circuit condition and over load condition are detected. Consequently, a mechanization framework in view of microcontroller which continuously screens the transformer is designed. PLC is used as a conveying medium between microcontroller and the computer. Microcontroller monitors and controls all the parameters of the distribution transformer and all the monitored and controlled data and status of the distribution transformer is sent from microcontroller to the computer through the existing power line without compelling reason to introduce any additional link. II. POWER LINE COMMUNICATION PLC is in view of electrical signals, conveying data, engendering over the power line. A communication channel is characterized as the physical way between two communication hubs on which the communication sign is spread. PLC as the name recommends, gives network utilizing existing power line as the correspondences medium. In this paper power line communication is utilized as a communicating medium between microcontroller and the computer. X-10 is a communication protocol intended for sending signals over 230V AC wiring. Power Line Communications for automatic transformer monitoring and controlling of distribution transformer applications applies the modulation of frequency signals in a carrier wave between 20 khz-200 khz into the 230V AC wiring at the transmitter. This carrier is modulated by digital signals. The IJIRT 142489 INTERNATIONAL JOURNAL OF INNOVATIVE RESEARCH IN TECHNOLOGY 255

recipient in the framework has a particular address and can be separately charged by signs transmitted more than 230V AC wiring and decoded at the collector. The gadgets can be either connected to customary electrical plugs, or forever wired set up. III. METHODOLOGY IV. FLOWCHART Fig. 1. Block Diagram The distribution transformer monitoring and controller developed in the present is designed to work autonomously. The framework is based on ARM7 microcontroller that is utilized to screen and control the various parameters of the transformer like temperature, oil level, and voltage and overload and short circuit conditions. The composed framework screens all the said above parameters alongside over-load and short out conditions routinely all through its operation. Thus the distribution transformer protection can be accomplished, consequently making the distribution transformer more robust, secure, dependable and proficient. Fast response and accurate fault detection can be obtained. In this work power line communication modem is utilized where all the information is corresponded with the existing power line. Fig. 2. Flowchart of the system Figure 2 demonstrates the working of the power line communication based automatic monitoring and controlling of distribution transformer. The framework will consistently screen the voltage and current appraisals of the transformer. If there should be an occurrence of over-burden condition the current of the transformer increments. When the current increases the buzzer beeps showing defective condition and outings the transfer. The microcontroller will be observing temperature of the transformer. If the temperature 40 0 the cooling fan will turn on and if the temperature increments over 50 0 the buzzer will beep again and trips the relay in this manner separating the load. Oil level will be observed consistently, if the oil level is under 25% the signal will beep demonstrating defective condition. Likewise spark IJIRT 142489 INTERNATIONAL JOURNAL OF INNOVATIVE RESEARCH IN TECHNOLOGY 256

across the transformer will be detected and the load will be disconnected. V. HARDWARE INPLEMENTATION VI. FUNCTIONAL OUTPUT Fig. 3. Hardware Implementation of the system As shown in the figure 3, the framework comprises of a distribution transformer, ARM7 microcontroller, voltage regulator, PLC modem, UART, LCD display, relays, different sensors like temperature sensor, fire sensor, voltage and current sensors. Additionally it also contains oil level indicator, cooling fan and buzzer. The distribution transformer is connected to ARM7 microcontroller. Microcontroller persistently screens the parameters of the distribution transformer displaying the readings in LCD and sends all the information to computer through PLC modem. The PLC modem comprises of transmitter end and receiver end. Transmitter end is connected to microcontroller board and the receiver end is connected to communication port. In this paper all the information is communicated using existing power line without introducing additional cable. The buzzer is also included in the system so that whenever there is any faulty condition the buzzer will beep automatically demonstrating the defective condition and giving a caution. Fig. 4. Voltage detected The microcontroller will continuously monitor the voltage and current values of the transformer and the data is sent to computer using power line communication. Figure 4 shows the voltage of the distribution transformer. Fig. 5. Oil level too low Fig. 6. Oil level detected at 65% IJIRT 142489 INTERNATIONAL JOURNAL OF INNOVATIVE RESEARCH IN TECHNOLOGY 257

VII. CONCLUSION Fig. 7. Oil Level detected at 80% The oil level of the transformer will be detected at three levels, when the oil level is too low, when the oil level is at 65% and when the oil level is 80%. Figure 5 shows the oil level when it is too low, figure 6 shows the oil level at 65% and figure 7 shows the oil level at 80%. When the oil is too low the buzzer will beep indicating the fault condition. In this paper, the distribution transformer is monitored and controlled using ARM7 microcontroller and the data is communicated using power line communication. The microcontroller based system continuously monitors the voltage, current, and temperature and oil level of a distribution transformer and automatically. The faulty conditions like over load and short circuit conditions are also screened. The system is also designed to sense if there is any fire across the transformer and immediately shut down the system. The readings of the transformer are continuously recorded and are displayed on the LCD. All the data in the system are communicated to the computer through the existing power line communication without installing extra cables. Whenever the fault occurs or there is any increase in the above mentioned parameters the relay automatically disconnects the load and with the help of the data displayed in the computer further actions can be taken. This system provides fast response and accurate fault. REFERENCES Fig. 8. Fire detected Various other conditions detected by microcomputer across the transformer like over load condition, short circuit condition, increase in temperature and fire across the transformer will be displayed in the computer. Figure 8 shows the fire detected across the transformer and figure 9 shows the short circuit condition of the transformer displayed in the computer. Whenever the faulty conditions occur in the transformer the buzzer will beep and microcontroller trips the relay and disconnects the load. Thereby we can protect the transformer from further damage. The parameters will be continuously measured by the microcontroller and displayed in the computer. With the help of the displayed data the operating personnel can take further actions during faulty conditions. [1] Vivek Akarte, Nitin Punse and Ankush Dhanorkar, Power Line Communication Systems, International Journal of Innovative Research inn Electrical, Electronics, Instrumentation and Control Engineering, January 2014, Vol. 2, Issue 1, pp. 2321 5526. [2] Davide Della Giustina, Paolo Ferrari, Alessandra Flammini, Stefano Rinaldi and Emiliano Sisinni, Automation of Distribution Grids With IEC 61850: A First Approach Using Broadband Power Line Communication, IEEE Transactions on Instrumentation and Measurement, 2013. [3] Mallikarjun Sarsamba, Prashant Sangulagi and Raju Yanamshetty, The Load Monitoring and Protection on Electricity Power lines using GSM Network, International Journal of Advanced Research in Computer Science and Software Engineering, September 2013 Volume 3, Issue 9, pp. 1131-1136. [4] Wenfei Zhu, Xu Zhu, Enggee Lim and Yi Huang, State-of-art Power Line Communications Channel Modelling, Information Technology and QuantitativeManagement, 2013, pp. 563 570. [5] Aaron St. Leger, John James and Dean Frederick, Smart Grid Modeling Approach for Wide Area Control Applications, IEEE, 2012. [6] A. Cataliotti, D. Di Cara, R. Fiorelli, and G. Tine, Power-line communication in medium-voltage system: Simulation model and on field experimental tests, IEEE Trans. Power Del., Jan. 2012, vol. 27, no. 1, pp. 62 69. IJIRT 142489 INTERNATIONAL JOURNAL OF INNOVATIVE RESEARCH IN TECHNOLOGY 258

BIOGRAPHY Author 1: Harshitha Keshav is pursuing her M.Tech under Industrial Automation and Robotics branch in Malnad College of Engineering, Hassan and completed B.E (EEE) in Vidya Vikas Institute of Technology under Visvesvaraya Technological University (VTU), Karnataka. Areas of interest are robotics, automation and power line communication. Author 2: Prof. Dr. B. Yogesh obtained his B.E degree (1986) in Mechanical Engineering from AIT, Chikkamagluru and M.Tech degree (1998) from IIT Kharagpur. He has completed his Ph.D degree (2006) from IIT Madras, Chennai. At present working as Professor, in the department of ME, MCE, Hassan. His areas of interest include manufacturing, metal forming and composite materials. He has twenty seven years of teaching experience, published twenty journals and attended sixteen conferences. IJIRT 142489 INTERNATIONAL JOURNAL OF INNOVATIVE RESEARCH IN TECHNOLOGY 259