NONLINEAR C-SCAN ACOUSTIC MICROSCOPE AND ITS APPLICATION TO CHARACTERIZATION OF DIFFUSION- BONDED INTERFACES OF DIFFERENT METALS

Similar documents
Ultrasonic Imaging of Tight Crack Surfaces by Backscattered Transverse Wave with a Focused Transducer

Detectability of kissing bonds using the non-linear high frequency transmission technique

Recent developments in nonlinear ultrasonic NDE. Thomas Grimsley Ritec, Inc., Warwick, RI USA

Ultrasonic Nonlinearity Parameter Analysis Technique for Remaining Life Prediction

Measurement of phase velocity dispersion curves and group velocities in a plate using leaky Lamb waves

STUDY ON SAW ATTENUATION OF PMMA USING LASER ULTRASONIC

ACOUSTIC AND ELECTROMAGNETIC EMISSION FROM CRACK CREATED IN ROCK SAMPLE UNDER DEFORMATION

THE ANALYSIS OF ADHESIVE BONDS USING ELECfROMAGNETIC

NUMERICAL MODELING OF AIR-COUPLED ULTRASOUND WITH EFIT. D. E. Chimenti Center of Nondestructive Evaluation Iowa State University Ames, Iowa, USA

Professor Emeritus, University of Tokyo, Tokyo, Japan Phone: ;

Rayleigh Wave Interaction and Mode Conversion in a Delamination

Transducer degradation and high amplitude behavior of broadband piezoelectric stack transducer for vibrothermography

AN AUTOMATED ALGORITHM FOR SIMULTANEOUSLY DETERMINING ULTRASONIC VELOCITY AND ATTENUATION

Aging Wire Insulation Assessment by Phase Spectrum Examination of Ultrasonic Guided Waves 1

CRACK SIZING USING A NEURAL NETWORK CLASSIFIER TRAINED WITH DATA OBTAINED FROM FINI1E ELEMENT MODELS

vibro-acoustic modulation

ACOUSTIC MICRO IMAGING ANALYSIS METHODS FOR 3D PACKAGES

Fundamental Study on Nonlinear Ultrasonic Imaging Method for Closed Cracks Using Subtraction of Responses at Different External Loads

NONDESTRUCTIVE EVALUATION OF CLOSED CRACKS USING AN ULTRASONIC TRANSIT TIMING METHOD J. Takatsubo 1, H. Tsuda 1, B. Wang 1

EFFECT OF SURFACE COATINGS ON GENERATION OF LASER BASED ULTRASOUND

Research Center for Advanced Science and Technology The University of Tokyo Tokyo 153, Japan

LASER GENERATION AND DETECTION OF SURFACE ACOUSTIC WAVES

Ginzton Laboratory, W. W. Hansen Laboratories of Physics Stanford University, Stanford, CA 94305

Module 2 WAVE PROPAGATION (Lectures 7 to 9)

Acoustic Resonance Analysis Using FEM and Laser Scanning For Defect Characterization in In-Process NDT

DETECTION AND SIZING OF SHORT FATIGUE CRACKS EMANATING FROM RIVET HOLES O. Kwon 1 and J.C. Kim 1 1 Inha University, Inchon, Korea

A NEW APPROACH FOR THE ANALYSIS OF IMPACT-ECHO DATA

ULTRASONIC SIGNAL CHARACTERIZATIONS OF FLAT-BOTTOM HOLES IN

ULTRASONIC DEFECT DETECTION IN BILLET USING TIME- OF-FLIGHT OF BOTTOM ECHO

THE LONG RANGE DETECTION OF CORROSION IN PIPES USING LAMB WAVES

High contrast air-coupled acoustic imaging with zero group velocity Lamb modes

A Numerical study on proper mode and frequency selection for riveted lap joints inspection using Lamb waves.

DISBOND DETECTION AND CHARACTERIZATION USING HORIZONT ALL Y

1813. Two-way collinear interaction of longitudinal waves in an elastic medium with quadratic nonlinearity

ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS

Generation Laser Scanning Method for Visualizing Ultrasonic Waves Propagating on a 3-D Object

REFLECTION AND TRANSMISSION OF LAMB WAVES AT DISCONTINUITY IN PLATE Z. Liu NDT Systems & Services AG, Stutensee, Germany

Ultrasonic Guided Wave Testing of Cylindrical Bars

Nonlinear Ultrasonic Damage Detection for Fatigue Crack Using Subharmonic Component

ULTRASONIC GUIDED WAVES FOR AGING WIRE INSULATION ASSESSMENT

FATIGUE CRACK DETECTION IN METALLIC MEMBERS USING SPECTRAL

Liquid sensor probe using reflecting SH-SAW delay line

Proceedings of Meetings on Acoustics

A SELF-COMPENSATING TECHNIQUE FüR THE CHARACTERIZA TION OF A

RECENT ADVANCEMENTS IN THE APPLICATION OF EMATS TO NDE

ENHANCEMENT OF B- AND C-SCAN IMAGES OF C-SAM WITH AN

NDI Techniques Supporting Steel Pipe Products

Acquisition and Analysis of Continuous Acoustic Emission Waveform for Classification of Damage Sources in Ceramic Fiber Mat

Excitation and reception of pure shear horizontal waves by

Light diffraction by large amplitude ultrasonic waves in liquids

OPTIMIZATION OF THE DELTA TECHNIQUE AND APPLICATION TO THE EVALUATION OF ELECTRON- BEAM WELDED TITANIUM AIRCRAFT PARTS

Application of Ultrasonic Guided Waves for Characterization of Defects in Pipeline of Nuclear Power Plants. Younho Cho

The Development of Laser Ultrasonic Visualization Equipment and its Application in Nondestructive Inspection

Assessment of lamination defect near the inner surface based on quasi-symmetric circumferential Lamb waves

XYZ Stage. Surface Profile Image. Generator. Servo System. Driving Signal. Scanning Data. Contact Signal. Probe. Workpiece.

WAVES. Chapter Fifteen MCQ I

Guided wave based material characterisation of thin plates using a very high frequency focused PVDF transducer

Ultrasonic Air-Coupled Non-Destructive Testing of Aerospace Components

Adhesive Thickness Measurement on Composite Aerospace Structures using Guided Waves

ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING

INTERNAL CONCRETE INSPECTION AND EVALUATION METHODS FOR STEEL PLATE-BONDED SLABS BY USING ELASTIC WAVES VIA ANCHOR BOLTS

ACOUSTIC MICROSCOPY INSPECTION OF GLASS REPAIR TECHNIQUES

Non-linear acoustics techniques for NDT

MATERIALS CHARACTERIZATION USING LASER ULTRASONIC GUIDED WAVES

Acoustic emission signal attenuation in the waveguides used in underwater AE testing.

Pre Test 1. Name. a Hz b Hz c Hz d Hz e Hz. 1. d

Spectrum and Energy Distribution Characteristic of Electromagnetic Emission Signals during Fracture of Coal

ABSTRACT 1. INTRODUCTION

ULTRASONIC DETECTION AND CHARACTERIZATION OF MICROSPHERICAL DEFECTS IN. Arthur Stockman, Patrick Mathieu, and Patrick S. Nicholson

Effect of coupling conditions on ultrasonic echo parameters

FATIGUE CRACK CHARACTERIZATION IN CONDUCTING SHEETS BY NON

Theory and Applications of Frequency Domain Laser Ultrasonics

DAMAGE DETECTION IN PLATE STRUCTURES USING SPARSE ULTRASONIC TRANSDUCER ARRAYS AND ACOUSTIC WAVEFIELD IMAGING

MEASUREMENT OF SURFACE ACOUSTIC WAVE USING AIR COUPLED TRANSDUCER AND LASER DOPPLER VIBROMETER

Recommendation of RILEM TC 212-ACD: acoustic emission and related NDE techniques for crack detection and damage evaluation in concrete*

Waves Q1. MockTime.com. (c) speed of propagation = 5 (d) period π/15 Ans: (c)

Lift-off Performance of Receiving EMAT Transducer Enhanced by Voltage Resonance

A STUDY ON NON-CONTACT ULTRASONIC TECHNIQUE FOR ON-LINE INSPECTION OF CFRP

NONDESTRUCTIVE EVALUATION OF ADHESIVE BONDS USING LEAKY LAMB WAVES* Cecil M. Teller and K. Jerome Diercks. Yoseph Bar-Cohen and Nick N.

Factors Affecting Ultrasonic Waves Interacting with Fatigue Cracks

Kissing bonds monitoring using nonlinear vibro-acoustic wave modulations

Capabilities of Flip Chip Defects Inspection Method by Using Laser Techniques

The Development of a High Sensitive Micro Size Magnetic Sensor Named as GSR Sensor Excited by GHz Pulse Current

2010 ULTRASONIC BENCHMARKS

ACOUSTO-ULTRASONIC EVALUATION OF HYBRID COMPOSITES USING

Investigation of Woven Fiber Reinforced Laminated Composites Using a Through Transmission Ultrasonic Technique

BENDING FRACTURE BEHAVIOR OF 3D-WOVEN SiC/SiC COMPOSITES WITH TRANSPIRATION COOLING STRUCTURE CHARACTERIZED BY AE WAVELET ANALYSIS

Ultrasonic pulse propagation in a bonded three-layered structure

Penn State University ESM Ultrasonics R&D Laboratory Joseph L. Rose Research Activities

DEVELOPMENT OF MEASUREMENT SYSTEM USING OPTICAL FIBER AE SENSORS FOR ACTUAL PIPING

Sound, acoustics Slides based on: Rossing, The science of sound, 1990.

BRAZING OF TIC CERMET TO STEEL Laansoo, A.; Kübarsepp, J. & Vainola, V.

Ultrasonic Time-of-Flight Shift Measurements in Carbon Composite Laminates Containing Matrix Microcracks

Method of Determining Effect of Heat on Mortar by Using Aerial Ultrasonic Waves with Finite Amplitude

Hiding In Plain Sight. How Ultrasonics Can Help You Find the Smallest Bonded Wafer and Device Defects. A Sonix White Paper

Physical mechanism of ultrasonic machining

Development of Automatic Neural Network Classifier of Defects Detected by Ultrasonic Means

Borehole vibration response to hydraulic fracture pressure

Sound velocity measurement using transfer function method

ULTRASONIC GUIDED WAVE FOCUSING BEYOND WELDS IN A PIPELINE

Transcription:

NONLINEAR C-SCAN ACOUSTIC MICROSCOPE AND ITS APPLICATION TO CHARACTERIZATION OF DIFFUSION- BONDED INTERFACES OF DIFFERENT METALS K. Kawashima 1, M. Murase 1, Y. Ohara 1, R. Yamada 2, H. Horio 2, T. Miya 3 and F. Fijita 3 1 Nagoya Institute of Technology, Nagoya, Japan, 2 Daido Steel Co., Nagoya, Japan, 3 SONIX K. K., Tokyo, Japan Abstract: A nonlinear C-scan acoustic microscope for industrial application has been developed to image the second harmonic amplitude excited at semi-closed microcracks, kissing bonds, or bonded interfaces of different materials, which are impossible by the conventional C-scan acoustic microscope. The second harmonic images have high spatial resolution compared with the conventional C-scan images. The contrast of the second harmonic images is confirmed by FFT analysis of the received waveforms. Introduction: The conventional C-scan acoustic microscope is useful for imaging of internal voids and cracks of finite volumes. However, imaging of semi-closed cracks and kissing bonds is very difficult due to partial transmission of ultrasonic waves across the closed cracks or gaps. Nonlinear ultrasonic technique, in particular the measurement of the second harmonic amplitude, has been used for evaluation of dislocation density 1, fatigue cracks 2, precipitations 3, adhesive joint 4, sintered steel powder 5 and diffusion bonded interfaces 6,7. Incident wave of finite amplitude, about ten times greater than the wave amplitude used for the conventional ultrasonic testing, can excite the second harmonic in solid materials by dislocation movement, nonlinear stress-strain response in compressive or tensile phase at bonded surface, clapping of closed crack surfaces. The second harmonic amplitude generated in metals by these mechanism is an order of 0.1~1% of the fundamental, incident, wave amplitude, therefore, piezo elements of a particular resonance frequency have been bonded to measure the second harmonic wave amplitude. Recently, the development of digital signal acquisition and signal processing make possible the second harmonic measurement with the conventional piezo transducers pressed on samples tested. This direct contact measurement, however, is not extended to image the second harmonic amplitude due to difficulty in scanning. Several pioneering works on the second harmonic imaging have been reported 8,9,10 for nondestructive characterization of bonded parts. To obtain the second harmonic images of bonded areas in water immersion, the reduction or separation of strong acoustic nonlinearity of water is very important. The second harmonic generated in water could mask the variation of the second harmonic of bonded interfaces. In the present paper, an approach to reduce the nonlinear effect of water is proposed. A nonlinear C-scan acoustic microscope of reflection as well as transmission mode is built. With the nonlinear acoustic microscope, we have visualized the second harmonic amplitude of diffusion- bonded interfaces of different metals. Basic theory: Assume that a nonlinear elastic stress strain relation shown in Fig.1 is given by. = K 2 2 K3 / 2 (1) The corresponding solution of wave equation is expressed by u = U expi( kx ωt) + ((3K 2 2 + K3) /(8K 2)) U t exp(2i( kx ω )) (2) where U is the fundamental wave amplitude, K 2 and K 3 are elastic stiffness of the second and third order, β=(3+k 3 /K 2 ) is the nonlinear parameter of the second harmonic. Equation (2) tells us that the second harmonic amplitude is proportional to the square of the fundamental wave amplitude and wave number as well as the propagation distance and β. When we use a burst wave of a fixed frequency, the second harmonic amplitude divided by U, the second harmonic ratio, is proportional to U, β and x. For an elastic solid including planar gaps comparable to the incident wave amplitude, plane longitudinal wave will close the gap surfaces when the gap is smaller than the incident wave amplitude, as shown in Fig.2. In gap free area, the stress-strain relationship will be linear as shown in Fig.2 (a). In a gap of which opening is

smaller than incident wave amplitude, tensile stress will not be transmitted, while compression stress will be transmitted after closing the crack in compression phase as shown in Fig.2 (b and c). In gap area which opening is larger than ultrasonic amplitude, ultrasonic wave will not be transmitted as shown in Fig.2 (d). Thus, the stress-strain response passing through micro gaps is expressed by superposition of stress-strain relations shown in Fig. 2 (e). The elastic modulus is higher in compression than in tension, therefore, elastic wave propagates at higher velocity in compressive phase as shown in Fig.3 and, considering this waveform distortion in frequency domain, higher harmonics appear as shown in Fig.4. Thus, the clapping brings in marked nonlinearity in the transmitted wave as that of acoustic nonlinearity of nonlinear continuum. It should be noted that the stress-strain relation shown in Fig.2 is extremely simplified. Namely, the real gaps or cracks have rough surface of the grain size order, therefore, the gap or crack surfaces will contact at some Compression Tension Fig. 1 Nonlinear elastic stress-strain curve. Plane wave δ1<a δ2<a δ3>a A Compression Tension No gap (a) No gap (b) δ1<a (c) δ2<a (d) δ3>a (e) Fig. 2 Stress-strain response around minute gaps comparable to incident wave amplitude.

Compression Displacement Incident wave Transmitted wave Time Amplitude A 1 A 2 Tension f 2f Frequency Fig.3 Waveform distortion. Fig.4 Generation of second harmonics. points at first. Under compressive stress, the contact points extend to microscopic contact areas with local plastic deformation. Also, the plastic deformation accompanies hysteresis loop under crack clapping. Experimental procedure: A schematic diagram of the nonlinear C-scan acoustic microscope is shown in Fig. 5. A conventional C-scan imaging system is extended to excite a tone-burst pulser and to extract the second harmonic components. Tunable analog bandpass filters are used to reduce the fundamental frequency component. In water immersion test, the acoustic nonlinearity of water is generally much higher than that of the solid materials tested. The second harmonic amplitude of water increases as a quadratic function of the incident wave amplitude as well as incident frequency. To minimize the second harmonic of water, we should use lower fundamental frequency and incident wave amplitude. This, however, brings in low spatial resolution and weak second harmonic generation in samples. Depending on required spatial resolution and the expected amplitude of the second harmonic generated in samples, we should select appropriate frequency and amplitude of incident wave. Also, tuning of bandpass filters is important. To demonstrate the effectiveness of the second harmonic imaging, we applied the nonlinear C-san acoustic microscope to examination of diffusion bonded 11 interfaces. Between steel and gamma titanium aluminide bars, Ni-based amorphous film was inserted. The bonding temperature was chosen lower than the melting point of base metal and higher than that of amorphous film. Bonding time is quite short, about 1 min., compared to Signal processing &imaging Burst wave pulser & Amp. Scanning controller Short wave pulser & amp. Scanning mechanism Water bath Tranmitter Sample Receiver

Fig. 5 Schematic diagram of a nonlinear C-scan acoutic microscope. diffusion bonding because the amorphous film aids the diffusion for bond. Shielding gas is Argon to protect the generation of oxide film on bonding surface. Compressive stress of several MPa is applied to both bars, and only bonding part is heated by induction coil to minimize the heat influence of base metal. The samples are cylinders of 15 mm in diameter and 18 mm in length. Experimental results and discussion: In the following, we show the conventional C-san image and the second harmonic images captured by reflection mode. A 5 MHz transducer of 1/4 in diameter and focal length of 2 was used for linear and nonlinear C-scan imaging. For the second harmonic imaging, we used bandpass filters to reduce the fundamental 3.5MHz component by 40dB. Figures 6 and 7 show the image of the same bonded interface at the identical gate position. Compared with the conventional C-scan image shown Fig. 6, the second harmonic image in Fig. 7 gives high spatial resolution. At present, the reason of the image contrast is not clear, however, there may be some variation in filler components and distribution of minute gaps at diffusion bonded interface. To confirm the validity of the second Fig. 6 Linear C-scan image. Fig. 7 The second harmonic Image. Fig. 10 Waveform and spectrum at point 3. Fig. 11 Waveform and spectrum at point 4. harmonic image, we captured time domain signals and their amplitude spectra at various positions, as shown in Figs. 8 to 11. The white + denotes the position where time domain signal was captured. In Fig.8, + is located in the brightest point, the lowest part in the bright ring.

The right upper widow shows the received signals, in which 7MHz component is amplified by 40 db. The red horizontal line denotes the gate interval. In Figs. 8 and 9, the signal from the bonded interface is much higher than those in Figs. 10 and 11. The amplitude spectrum in lower right window shows large amplitude at 7 MHz in Figs. 8 and 9, but does comparable amplitude in 3.5 and 7 MHz in Figs. 10 and 11. These amplitude spectra prove that the second harmonic images are valid. Conclusions: A nonlinear C-scan acoustic microscope has developed to visualize the distribution of the second harmonic amplitude. By selecting appropriate incident frequency and wave amplitude as well as tuning bandpass filters, we obtain the second harmonic images of high resolution. The validity of the harmonic images is confirmed by amplitude spectra at various positions. Acknowledgement: This research has partly been supported by Grant in Aids for Scientific Research from Japanese Ministry of Education, Science and Culture (B 10450047, B 12555024) and Cooperative Research Grant from SONIX K.K. and Daido Steel Co. References: 1. A. Hikata, B. B. Chick, and C. Elbaum, Appl. Phys. Lett., 3, 195(1963) 2. O. Buck, W. L. Morris, and J. M. Richardson, Appl. Phys. Lett., 3371, (1978). 3. J. H. Cantrell and W.T. Yost, Philos. Mag. A 69, 315 (1994). 4. M. Rothenfusser, M.Mayr and J. Baumann, Ultrasonics, 38, 322 (2000). 5. Y. Ohara, K. Kawashima, M. Murase, N. Hirose, Review of Progress in QNDE, eds. D. O. Thompson and D. E. Chimenti, 22B, 1257 (2003). 6. D. J. Barnard, G. E. Dace, D. K. Rehbein, and O. Buck, J. NDE, 16-2, 77(1997). 7. Y. Ohara, K. Kawashima, R. Yamada and H. Horio, Review of Progress in QNDE, eds. D. O. Thompson and D. E. Chimenti, 23B, in press (2004). 8. T. P. Berndt and R. E. Green Jr., Nondestructive Characterization of Materials IX, 394 (1999). 9. F. M. Severin, B. O nail and R. Maev, Review of Progress in QNDE, eds. D. O. Thompson and D. E. Chimenti, 19A, 881(2000). 10. C. Mattei and P. Marty, Review of Progress in QNDE, eds. D. O. Thompson and D. E. Chimenti, 23A, 989 (2003). 11. T.Shimizu, H.Horio, J. Japan Weld. Soc., 66-6, 14(1997).