User s Guide. Model MA A AC Mini Clamp-on Meter

Similar documents
USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

200Amp AC Clamp Meter + NCV Model MA250

User s Guide. Digital AC/DC Clamp Meter Model 38394

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

True RMS AC / DC Power Clamp Meter Model

User Guide. AC/DC Mini Clamp Meter. Model

400Amp True RMS AC Clamp Meter + NCV

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

400Amp True RMS AC/DC Clamp Meter Model EX613

Autoranging Multimeter Extech EX503

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Pen Multimeter. Model

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

R/C SMD Tweezers Multimeter Model RC200

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

Pen Multimeter. Model

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

High Temperature InfraRed Thermometer with Laser Pointer

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

User s Manual. Ground Resistance Clamp On Tester MODEL

User's Manual. Clamp-on Power Datalogger. Model

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

USER'S MANUAL DMR-6700

User's Manual. Model f/1f Power Clamp-on Meter

Compact MultiMeters + Voltage Detector

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Non-contact Forehead IR Thermometer

User s Guide. Combination Photo-Tachometer Stroboscope Model

AUTORANGING TRUE RMS MULTIMETER USER GUIDE. INST151 Doc 1.00

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Passive Component LCR Meter

Dawson DDM190. Digital Multimeter User s Manual

Operating Instructions 22070T True RMS AC/DC CLAMP METER Instrucciones de uso. Pinza amperimétrica de CA/CC de RMS verdadera

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Passive Component LCR Meter

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

PCMT20 PYLE C;",D J WWWPYLEAUDIO.COM

AC Clamp Meter + Phase Rotation Tester

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

MS2030 CAT III 600 V A V AUTO RS232

DDM350 Pen-Type Digital Multimeter User s Manual

DM-46 Instruction Manual

ET-3888 True RMS Clamp Meter. User Manual

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

USER MANUAL. UV AB Light Meter. Model UV505. Additional User Manual Translations available at

User Guide. EasyView Digital Light Meter. Model EA31

Heavy Duty Meter Model

AC/DC CLAMP METER USER S MANUAL

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

User s Guide Shop online at omega.com For latest product manuals: omegamanual.info

Not for Reproduction

USER'S MANUAL TBM061 TBM062 TBM063 TBM065

Multifunction Digital

OPERATOR S INSTRUCTION MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

USER MANUAL. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

User Manual 4 wire Earth Resistance Tester Model GRT300

OPERATING INSTRUCTION

DM-46 Instruction Manual

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

Pen-type DIGITAL MULTITESTER

312, 316, 318. Clamp Meter. Users Manual

INSTRUCTION MANUAL UTL260

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

CONTENTS MS2033A. 1.Introduction Safety Information...01

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

Model Digital Light Meter

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

DM-45 Digital Multimeter

USER'S MANUAL DMR-4350

600A Clamp Meters w/tightsight Display

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

Transcription:

User s Guide Model MA150 200A AC Mini Clamp-on Meter

Introduction Congratulations on your purchase of Extech s MA150 AC Mini Clamp Meter. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Meter Description 1. Current sense jaw 2. Non-contact AC voltage indicator light 3. Flashlight button 4. Rotary function switch 5. MAX hold and Backlight key 6. LCD display 7. Clamp trigger 8. MODE key 9. COM input jack 10. V Ω input jack 9 10 Safety Information! Caution! Refer to the explanation in this Manual Double Insulation This meter has been designed to be safe in use, but the operator must use caution in its operation. The rules listed below should be carefully followed for safe operation. 1. NEVER apply voltage or current to the meter that exceeds the specified maximum: 2. USE EXTREME CAUTION when working with voltages greater than 60VDC or 25VAC rms. These voltages are considerd a shock hazard. 3. NEVER operate the meter unless the back cover and the battery/fuse door are in place and fastened securely. Function AC Current AC/DC Voltage Resistance, Diode, Continuity Test Input Limits Maximum Input 200A 600V AC/DC 600V AC/DC 2

Operation AC Current Measurements 1) Set the Function switch to the 200A AC range. 2) Press the jaw trigger and clamp around, fully enclosing a single conductor. Do not allow a gap between the two halves of the jaw. Refer to the diagram at right for the correct way to enclose a single conductor. 3) Read the ACA value on the LCD. AC/DC Voltage Measurements 1) Insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal. 2) Set the function switch to the V position. 3) Select AC or DC with the MODE button. 4) Connect the test leads in parallel to the circuit under test. 5) Read the voltage measurement on the LCD display. Resistance and Continuity Measurements 1) Insert the black test lead into the negative COM terminal and the red test lead into the positive V Ω terminal. 2) Set the function switch to the Ω position. 3) Use the MODE button to select resistance. The MΩ icon will appear in the display. 4) Touch the test leads across the circuit or component under test. It is best to disconnect one side of the device under test so the rest of the circuit will not interfere with the resistance reading. 5) For Resistance tests, read the resistance on the LCD display 6) For Continuity, use the MODE button to select continuity ))). The display icons will change when the MODE button is pressed. 7) If the resistance is <120 Ω a tone will sound. Yes No Diode Test 1) Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V Ω jack. 2) Set the function switch to the Ω position. 3) Press the MODE button to indicate on the display. 4) Touch the test probes to the diode under test. Forward voltage will typically indicate 0.400 to 0.700V. Reverse voltage will indicate OL. Shorted devices will indicate near 0V and an open device will indicate OL in both polarities. 3

Non-Contact AC Voltage Detection WARNING: Risk of Electrocution. Before use, always test the Voltage Detector on a known live circuit to verify proper operation 1) AC Voltage detection operates on any of the three Function switch positions. 2) Touch the probe tip to the hot conductor or insert into the hot side of the electrical outlet. 3) If AC voltage is present, the detector light will illuminate. NOTE: The conductors in electrical cord sets are often twisted. For best results, slowly slide the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor. NOTE: The detector is designed with high sensitivity. Static electricity or other sources of energy may randomly turn the detector light on. This is normal operation MAX Hold To hold the highest reading on the LCD, momentarily press the MAX key. The meter reading will not change as readings change, rather it will only display the highest reading encountered since the MAX hold button was pressed. Press the MAX hold button again to return the meter to normal operation. Backlight Press and hold the MAX key for more than one second to turn the backlight on. This will also activate the MAX Hold function. To release the MAX Hold function and return the meter to normal operation, press the MAX key momentarily. The backlight will automatically turn off after 15 seconds. To manually turn off the backlight, press and hold the MAX key for more than 1 second. Flashlight Press and hold the top button to turn the flashlight on. Release the button to turn the flashlight off. 4

Specifications General Specifications Display Polarity Jaw opening Current sensor AC Current Bandwidth AC Voltage Bandwidth Overload indication Display rate Battery Low Battery indication Auto Power off Operating conditions Storage conditions Altitude Weight Dimensions Standards 2000 count Digit LCD with white LED backlight Minus sign (-) indicates negative polarity 0.7 (18mm) Hall effect sensor type 50/60Hz 50/400Hz OL displayed on the LCD 2 readings/second, nominal Two 1.5V AAA batteries BATT displayed on the LCD approx. 15 minutes 32 to 86 º F (0 to 30 º C) 90%RH; 86 to 104 º F (30 to 40 º C) 75%RH; 104 to 122 º F (40 to 50 º C) 45%RH - 14 to 140 º F (-30 to 60 º C); < 90% Relative Humidity Operate at less than 3000 meters 6.2 oz. (176g) including battery 6.5 x 2.6 x 1.3 (164 x 65 x 32mm) (HWD) For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (1995): EN61010-1 (1995) Overvoltage Category III 300V and Category II 600V, Pollution Degree 2. CC 5

Range Specifications Function Range Resolution Accuracy (of reading) AC Current 200.0A 0.1A ± (2.5% rdg + 10 digits) DC Voltage 200.0mV 0.1mV ±(0.5% rdg + 5 digits) 2.000V 1mV 20.00V 10mV ±(1.2% rdg + 3 digits) 200.0V 0.1V 600V 1V ±(1.5% rdg + 3 digits) AC Voltage 2.000V 1mV 20.00V 10mV ±(1.5% rdg + 3 digits) 200.0V 0.1V 600V 1V ±(2.0% rdg + 4 digits) Resistance 200.0Ω 0.1Ω ±(1.0% rdg + 4 digits) 2.000kΩ 1Ω 20.00kΩ 10Ω ±(1.5% rdg + 2 digits) 200.0kΩ 100Ω 2.000MΩ 1kΩ ±(2.0% rdg + 3 digits) 20.00MΩ 10kΩ ±(3.0% rdg + 5 digits) Non-Contact AC Voltage 100VAC to 600VAC 50/60Hz Test current: 0.3mA typical; Diode Test Open circuit voltage: 1.5VDC typical Continuity Threshold <120Ω Test current <1mA 6

Maintenance Battery Replacement 1) When the low battery symbol appears on the LCD the batteries must be replaced. 2) Power down and remove the rear battery compartment Phillips screw. 3) Lift off the battery compartment cover and replace the two 1.5V AAA cells. 4) Replace compartment cover and secure the screw. You, as the end user, are legally bound (EU Battery ordinance) to return all used batteries, disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle Cleaning Caution: Use only a dry cloth to clean the plastic case. Warranty EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department for authorization. Visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Support lines: U.S. 877-439-8324, Intl. 603-324-7800 Technical support: Option 3; E-mail: support@extech.com Repair & Returns: Option 4; E-mail: repair@extech.com Product specifications subject to change without notice Visit our website: www.extech.com Extech Instruments Corporation, 9 Townsend West, Nashua, NH 03063 ISO 9001 Certified since 1995 7