Maharashtra State Electricity Distribution Co. Ltd.

Similar documents
Maharashtra State Electricity Distribution Co. Ltd.

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Technical Specification. for 1.1 KV Copper Control Cable

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

TECHNICAL SPECIFICATION

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Plant Client Contract Code Document ID Contract No. TECHNICAL SPECIFICATIONS DC SHUNT Rev 00 Page 1 of 2

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

50-SDMS-01 SPECIFICATIONS FOR

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

POTENTIAL TRANSFORMER

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

TECHNICAL SPECIFICATION OF 11 KV THREE PHASE FOUR WIRE, THREE CTs COMBINED METERING CTPT SET OF ACCURACY CLASS 0.5s

SPECIFICATION FOR 11 KV CLASS, 24/15.7, 30/19.7 & 45/29.5 AMPS SPECIAL DESIGN TRANSFORMERS.

Technical Specifications for Portable 3-Ø Power Analyzer

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

TECHNICAL SPECIFICATION OF 11 KV AND 22 KV THREE PHASE FOUR WIRE, THREE

MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. TECHNICAL SPECIFICATION FOR. 36 kv (PROTECTION CUM METERING) INSTRUMENT TRANSFORMERS

TECHNICAL SPECIFICATION FOR 22 KV CURRENT TRANSFORMERS

MANUFACTURING GUIDELINES FOR PLC (LEVEL-1 AUTOMATION)

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES... 4

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

SPECIFICATION FOR SAFETY POLE SIGNS & ACCESSORIES

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

LIGHTNING ARRESTOR. September 2017 WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

1.0 mh, 3150 A LINE TRAP

The RSM shall be extensively used in field & laboratory for verification of the accuracy of all types of single-phase energy meters.

SUPPLY OF CARRIER PROTECTION COUPLER TYPE NSD-50

CAPACITOR VOLTAGE TRANSFORMER

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type

THE KENYA POWER AND LIGHTING CO. LTD. SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT

TECHNICAL SPECIFICATION FOR SELF PROTECTED SINGLE PHASE DISTRIBUTION TRANSFORMERS ( SPECIFICATION NO: DIST/01-N/2004 )

TECHNICAL SPECIFICATIONS

PROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

TECHNICAL SPECIFICATION FOR. CONTACT WIRE HARD-DRAWN COPPER 161mm2

SOUTHERN ELECTRICITY SUPPLY COMPANY OF ODISHA LIMITED (SOUTHCO UTILITY)

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

Maharashtra State Electricity Distribution Company Limited

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

001: 2007 CEB STANDARD

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

GENERAL TECHNICAL SPECIFICATION (Turnkey Work)

SHARDA Make Harmonics Filter

REPORT OF PERFORMANCE TIC

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

TECHNICAL SPECIFICATION FOR G. I. WIRE (4MM)

INTERPLANT STANDARD - STEEL INDUSTRY

Reference Number PPS 05 - (RIC Standard: EP SP)

Technical Specification For 33 KV, Single Phase, Dead Tank Type Out Door Current Transformer Of Different Ratio

MESP TECHNICAL SPECIFICATION FOR BARE FLEXIBLE ANNEALED COPPER JUMPER WIRE 37/7/ mm 2

VI 3 - i TABLE OF CONTENTS

DISTRIBUTION TRANSFORMER 11 / kv

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

TECHNICAL SPECIFICATION OF STAY WIRE FOR TRANSMISSION LINES AND SUB STATIONS

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

(TECHNICAL SPECIFICATIONS & GTP FORMATS) 11KV METERING UNITS

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

ASSEMBLY TOOLS FOR SCREWS & NUTS. Part 1: Insulated hand operated socket drive wrenches and screw drivers


Technical Specifications SECTION C

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

SI.No Parameters CPRI Specification/Requirements To be Completed by the Bidder Guaranteed Technical

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations

Maharashtra State Electricity Distribution Company Limited

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

MILITARY SPECIFICATION TRANSFORMERS, POWER, STEP-DOWN, SINGLE-PHASE, 60-HERTZ, 1-KILOVOLTAMPERE APPROXIMATE MINIMUM RATING, DRY TYPE, NAVAL SHIPBOARD

page 2 of 86 Report reference No:

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

Standard. Extra High Voltage (EHV) Current Transformer Standard R Version 1.0, June Tasmanian Networks Pty Ltd (ABN )

TECHNICAL SPECIFICATION OF 630 KVA, 11/ KV DRY TYPE OUTDOOR TRANSFORMERS.

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

TECHNICAL SPECIFICATION OF LT SHACKLE BOLT (G. I. BOLT) WITH NUT AND SPRING WASHER

GENERAL TECHNICAL SPECIFICATION

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

TECHNICAL SPECIFICATION FOR LEVEL CONTROL VALVE HANDLING WATER

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

VariSTAR Type AZL heavy-duty distribution-class MOV arrester

Annexure - V. Specifications, Typical Drawing & Data Sheet for Split TEE (Hot Tapping Material)

MESP TECHNICAL SPECIFICATION FOR FLEXIBLE DROPPER WIRE TIN-BEARING COPPER 7/7/ mm 2

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

SECTION-I (G.I.PLAIN WIRE) TECHNICAL SPECIFICATION FOR G. I. WIRE

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA TECHNICAL SPECIFICATIONS

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS 400KV, 8800PF LINE CVT FOR EXISTING & NEW SUB- STATIONS

TECHNICAL SPECIFICATION FOR G.I. WIRE AND G.I. STAY WIRE

DISTRIBUTION TRANSFORMER kv

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Transcription:

Maharashtra State Electricity Distribution Co. Ltd. Draft SPECIFICATION NO. MSEDCL/ DIST:MSC-III/LT MPP CAP/11/2009/R0 SPECIFICATIONS FOR MPP TYPE L.T. CAPACITOR UNITS OF 25 / 30 KVAR CAPACITY (FOR 63 / 100 KVA DISTRIBUTION TRANSFORMERS) (Approved on 28.10.2009) Page 1 of 15

TECHNICAL SPECIFICATION FOR LOW TENSION (FIXED) SHUNT CAPACITOR UNITS (MPP TYPE) FOR DISTRIBUTION TRANSFORMERS (Spec. No. MSEDCL/Dist:MSC-III/ LT MPP CAP/11/2009/R0) INDEX Sr.No Particulars Page No 1. Scope 3 2. Operating Conditions 3 3. Electrical Characteristics & Features 4-7 4. Tests & Inspection 7 5. Type Tests 7-8 6. Acceptance Tests 8 7. Routine Tests 9 8. Qualifying Requirements 9 9. Drawings and Catalogues 9 10. Guarantee 9-10 11. Packing 10 12. Schedules 10 13. Guaranteed Technical particulars Schedule A 11-12 14. Schedule of deviation from Specification Schedule 'B' 13 15. Schedule of Tenderer s experience Schedule 'C' 14 16. Schedule of deviation from specified test requirement Schedule 'E' 15 Page 2 of 15

TECHNICAL SPECIFICATION FOR LOW TENSION (FIXED) SHUNT CAPACITOR UNITS (MPP TYPE) FOR DISTRIBUTION TRANSFORMERS 1.0 SCOPE The specification covers supply of 440 V, 3 Phase delta connected 50 Hz, outdoor, MPP type LT capacitor units of ratings 25 & 30 KVAr intended for improvement of power factor and to be installed on LT side of Polyphase Distribution Transformer of rating 63/100 KVA. It is not the intent to specify completely herein all the details of design and construction of the capacitor unit. However, the capacitor shall conform to the high standards of design and workmanship mentioned in Clause no. 3 & 4 and be capable of performing continuous and satisfactory operations in the actual service conditions at site and shall have sufficiently long life in service as per statutory requirements. The purchaser shall have power to reject any work or material which in his judgment is not in accordance therewith. The capacitor offered shall be complete with all parts necessary for their effective & trouble free operation. Such components shall be deemed to be within the scope of supplier s supply irrespective of whether they are specifically brought out in the specification and commercial order or not. The tenderer/ supplier shall bind himself to abide by these considerations to the entire satisfaction of the purchaser and will be required to adjust such details at no extra cost to the purchaser over & above the tendered rates and prices. In actual practice, not withstanding any anomalies, discrepancies, omissions, incompleteness, etc. in these specifications, the design and constructional aspects, including materials and dimensions, will be subject to good engineering practice in conformity with the required quality of the product, and to such tolerances, allowances and requirements for clearances etc. as are necessary by virtue of various stipulations in that respect in the relevant Indian Standards, IEC standards, I.E. Rules, I.E. Act and other statutory provisions. 2.0 OPERATING CONDITIONS: 1) Installation Outdoor (to be located on LT side of 63/100 KVA Distribution Transformer) 2) Ambient temperature - 10 C to +50 C 3) Altitude Not exceeding 1000 meters above sea level. Page 3 of 15

3.0. ELECTRICAL CHARACTERISTICS & FEATURES: 3.1 GENERAL REQUIREMENT: Capacitors of rating 25 & 30 KVAR shall be of three phase having metalized (Silver, Zinc, Aluminum) polypropylene (MPP) type material complying with IS: 13340/1993, IS 13341/1992, or IEC 831-1 (with latest version amendments). Capacitors shall be protected by internal fuses as per IS 12672/1989. Capacitors shall be ISI marked. The capacitor unit shall be Heavy Duty with modular construction and provided with suitable device per module (inductor coil) to control the inrush current. The capacitor shall have self-healing property & each module shall have the pressure sensitive safety device/ internal fuse elements and shall be suitable for 200 times rated current to take care. The capacitor unit shall be self-cooled totally vermin proof & suitable for outdoor use. The material used in the capacitor unit shall be of superior quality. Three terminals of the capacitor unit shall be covered with suitable enclosure cover on which MCB of suitable ratings will be clamped/fixed. Connections from the capacitor unit shall be brought out to the MCB. There should be provision for cable entry from bottom for connection of MCB to LT side of the Distribution Transformer. Three Nos. LED indicators shall be provided on the container to be connected between MCB and capacitor for indicating the working status on each phase of the capacitor unit. LED indicators may be provided across a suitable series resistance to indicate failure of capacitor. The capacitor container shall be provided with a clearly marked earth terminal. The capacitor shall be provided with discharge resistor, which will discharge capacitor when switched off to less than 50V in one minute. In addition a suitable mechanism should be provided for verifying the status/working condition of Capacitor unit. (LED's etc). General requirement is as follows. Sr. No. Particulars Requirements 1 Rated voltage 440 Volts 2 Rated frequency 50 Hz 3 Rated KVAR 25, 30 KVAR, 440V (poly phase) 4 Phase & Connections 3-phase Delta connected. 5 Maximum over voltage 1.1 times Rated Voltage for Max. duration 12 hrs. in every 24 hrs 1.15 times Rated Voltage for Max. duration 30 min. in every 24 hrs 6 Maximum over current. 1.43 times Rated Current. 7 Capacity tolerance. -5% to 10% 8 Temperature. - 25 C to 50 C 9 Loss (Watts/KVAr) 0.5 Watts/KVAr (Max.) 10 Max. ambient temperature 50 C Page 4 of 15

Sr. No. Particulars Requirements 11 Max. average temperature 40 C value over 24 hrs. 12 Discharge devices. Discharge voltage less than 50V within one minute. 13 Life expectancy 100000 Hrs. 14 Insulation level 3 KV 15 Reference standards. IS: 13340/1993, IS 13341/1992, IS12672/1989, IEC 831-1 3.2 RATED VOLTAGE: The rated voltage shall be 440 volts with fluctuation in supply voltage as specified in IS: 585/ 1962 and IS: 12360/ 1951 (with latest amendment) and shall not affect the normal working of the equipment. 3.3 PERMISSIBLE OVERLOADS: 1) Permissible overload should be as per IS: 13340/1993. i) Voltage: Capacitor shall be suitable for prolonged operation at RMS voltage between terminals not exceeding 1.10 times the rated voltage as per IS13340/1993. ii) Current: Capacitor shall be suitable for continuous operation at R.M.S. line current of 1.30 times, the current that occurs at rated sinusoidal voltage and rated frequency excluding transit. 3.4 DIELECTRIC: The capacitor elements should be wound in Metalized polypropylene film. The capacitor unit shall be self-cooled. Dielectric consists of three layer metalized (Silver, Zinc, Aluminum) polypropylene (MPP) with heavy edge. 3.5 IMPREGNATION: The elements shall be impregnated with a impregnant which has been completely refinished and degasified so as not to have any deterioration of the dielectric material. The impregnant used shall have high dielectric constant, low viscosity and high chemical stability. The impregnant should be NPCB (Non - poly chlorinated Biphenyl) with low RAPID BIO DEGRADATION AND LOW TOXICITY and should be non oxidizing and especially suitable for capacitors. 3.6 A. HOUSUNG FOR CAPACITOR UNIT The Housing in CRCA sheet steel (Square Type or Cylindrical type ) enclosures fully metal with 2 mm thick & shall be coated with weather proof & corrosion resistant paint of dark admiral grey shade OR the housing with SMC box conforming to IS-13410 with thickness of enclosure not less than 2 mm. Page 5 of 15

B. HOUSING ASSEMBLY: Where more than one units are used these individual units should be housed in metallic enclosure (square type) made of minimum 2 mm thick CRCA sheet with proper ventilation and with front-hinged door to enable the easy maintenance and replacement in case of damage of any units. Only three terminals shall be brought to the individual MCB of suitable ratings, which are clamped in the enclosure on the back sheet. There should be provision for cable entry. The outside of the enclosure should have smooth and tidy look and shall be coated with weather proof & corrosion resistant paint of dark admiral grey shade. There should be proper provision for clamping so as to mount the metallic enclosure on the transformer pole structure. Copy of GA drawing is enclosed for reference. Proper cable glands wherever necessary should be provided. The maximum length of the cable required shall be 5 mtrs/ Installation & the same shall be supplied by the supplier. Lugs of proper size shall be crimped to the cable. 3.7 MCBs: TP type MCBs being provided shall be of appropriate rating as per the rating of the capacitor. The MCBs shall be suitable for capacitor switching duty ( D Curve ) & shall conform to IS:8828/1995 / IEC: 60898. Approved make of MCB s shall be Siemens / Havells / Schnieder / Hagger (L&T) / Indo Asian etc. Type test for MCB shall be submitted before supply. Interconnection wire between capacitor to MCB shall be of flexible copper wire of suitable size. The typical rating of MCB and PVC Cable are as given below Rating of capacitors Rating of MCB 25 KVAR 63 Amps,3P, 10KA MCB ( D Curve) 30 KVAR 63 Amps,3P, 10KA MCB ( D Curve) 3.8 BUSHINGS: Interconnection wire between capacitor to MCB 10 SQ. MM, Copper, FR Grade wire (ISI marked) 10 SQ. MM, Copper, FR Grade wire (ISI marked) Connection between MCB to Transformer 16 Sq. mm PVC insulated, Unarmored Aluminum. 3 core, Cable (ISI marked) 25 Sq. mm PVC insulated, Unarmored Aluminum. 3 core, Cable (ISI marked) Ceramic /porcelain or FRP fiberglass to ensure good insulation with threaded M.S Tin terminals are to be provided. Also to provide copper cable of length 5 metres, 16 sq.mm for connections. 3.9 RATING PLATE: The following information shall be marked indelibly, either directly or by means of a plate, on each capacitor unit in accordance with clause 10.1 of IS: 13340/1993. Page 6 of 15

a) Reference IS : b) Name of manufacturer : c) Type of capacitor : d) Serial No. & year of manufacture : e) Rated output in KVAr : f) Rated voltage in Volts : g) Rated frequency : h) Temperature Category: i) Discharge device shall be indicated by wording or the symbol --------------- or by the rated resistance in kilo-ohms or megaohms; the symbols I or E shall be used for internal or external discharge device and IC for inductive coil when provided in the capacitor. j) Reference to self healing design; SH or / # and type of dielectric MPP/MP k) Connection Symbol as per Cl. 10.2 of IS:13340 /1993 l) Internal fuses, if included shall be indicated by wording or by symbol. m) Insulation level Ui in kv n) Symbol for over pressure disconnector o) The words "PROPERTY OF M.S.E.D.C.L" shall be marked cautiously on the outer enclosure of capacitor unit with legible marking along with details of Purchase Order No., date, rating etc. 3.10 SAFTY REQUIRMENTS: 1) Capacitor unit shall be provided with directly connected discharge device as per IS: 13340/1993.(with latest amendment) 2) The discharge devise shall reduce the residual voltage from the crest value of the rated voltage to 50 V or less within one minute after the capacitor is disconnected from the source of supply. 3) Earth Connection: The Capacitor Container shall be provided with as suitable earth terminal clearly marked. It should be suitable to take up a lug suitable for 10 Sq.mm conductors with a bolt hole dia. of 10 mm 4.0 TESTS AND INSPECTION: 4.1 TYPE TESTS: All the tests indicated at Clause 12.2.2 of IS: 13340/1993 with latest amendments shall constitute the type tests. All the type tests shall be carried out at the laboratories accredited by National Accreditation Board of Testing and Calibration Laboratories (NABL) in accordance with the IS: 13340/1993 & the requirements specified in IS : 13341/1993 for ageing test, self healing test & destruction tests. The detailed Type test reports have to be submitted to CE (Dist) for approval prior to the commencement of supply. Type tests shall comprise of the following. i) Voltage Test between Terminals Page 7 of 15

ii) A. C. Voltage Test between Terminals and Container iii) Thermal Stability Test iv) Capacitor Loss Tangent (Tanδ) measurement at elevated temperature. v) Self healing test vi) Lightning Impulse Voltage Test between Terminals & Container vii) Short Circuit Discharge Test. In addition to the above following Special tests as per amendment 1 to IS:13340/ 1993 shall be carried out & submitted for approval. i) Ageing test ii) Destruction test The tenderer shall furnish copies of type test reports as per relevant, IS, or the confirmatory tests as per the equivalent international standard as the case may be, for the equipments material offered along with the tender. The tenderer should note that the offers received without type test reports shall stand rejected. The equipment offered shall be fully type tested as per the relevant standards for all the type tests specified in the IS at the testing laboratories accredited by National Accreditation Board of Testing and Calibration Laboratories (NABL). The offered equipments should be type tested prior to maximum five years before the date of opening of tender. In case the Tender is not accompanied by the type test Certificates Board reserves the right of cancel / reject the Tender. 4.2 ACCEPTANCE TESTS: All the tests specified at Clause 12.3.1 of IS: 13340/1993 (with latest amendments) for MPP type capacitors shall constitute the acceptance tests as follows. i) Visual examinations. ii) Test for output and capacitance iii) Capacitor loss tangent (tan delta) measurement. iv) Insulation Resistance Test. v) A. C. Voltage test between terminals vi) A. C. Voltage test between terminals & container. vii) Test for discharge device. viii) Sealing test. Sampling plan shall be as per Annex F Clause 12.3 table 5 of IS: 13340/1993. The same is reproduced bellow. SAMPLE SIZE & PERMISSIBLE NUMBER OF DEFECTIVES Lot Size Sample Size Permissible no. of defectives (1) (2) (3) Up to 100 8 0 101 to 300 13 0 301 to 500 20 1 501 to 1000 32 2 1001 and above 50 3 Page 8 of 15

4.3 ROUTINE TESTS: All individual capacitor units shall be subjected to the routine tests at the manufacturer s Works (at the cost of the manufacturer) for the detail tests specified in Clause 12.1.1 of IS: 13340/1993. A certificate detailing the results of such tests shall be furnished by the supplier along with inspection call to the purchaser. 4.4 TESTS AT SITE: The purchaser/chief Engineer (Dist) reserves the right to conduct all or any of tests on LT shunt capacitors after arrival at stores/site and the contractor shall guarantee test certificate figures under actual service condition. The capacitor loss should not be more than 0.5 watts/kvar. The bidder must indicate the loss of the capacitors offered without fail. 5.0 QUALIFYING REQUIREMENT FOR BIDDER The bidder should fulfill following qualifying requirements for participation in the tender and submit relevant document and evidence supporting each qualifying requirement along with the offer, failing which the offer shall be liable for rejection. 1. The bidder should have proven experience of not less than 2 years for supply of capacitors / materials offered for equal or higher KVAr rating and 50 % of the quantity supplied shall be in successful operation for more than 1 year. Documentary evidence duly audited by chartered accountant shall be enclosed along with offer. 2. The bidder shall furnish valid type test certificate for 25 KVAr or above rating, 440 V, 3 phase capacitors, as per IS: 13340/1993 carried out from the NABL accredited laboratory. Type test certificate should not be older than 5 years as on the date of opening the tender. 6.0 DRAWINGS AND CATALOGUES: The tender must accompany relevant catalogues and sectional drawings showing necessary details of equipments offered. One copy of dimensional drawing and internal construction drawing (on A3/A4 paper size only) should be submitted with tender. The successful tenderer will have to submit the detailed dimensions and internal construction drawings along with the samples to the C.E. (Dist) for his approval before the bulk supply. No extra period will be allowed in period and delivery schedule given to the tenderer. 7.0 GUARANTEE: Capacitor/MCB offered shall be guaranteed for a period of 12 months from the date of commissioning or 18 months from the date of supply whichever is earlier. Page 9 of 15

The contractor should keep sufficient stock at stores so that complaint can be attended within one week from the date of reporting. The capacitor/mcb found defective within the above guarantee period shall be replaced/ repaired by the supplier free of cost; within one week of receipt of intimation. If the defective stores/material are not replaced/repaired within the specified period as above, the board shall recover an equivalent amount plus 15% supervision charges from any of the bills of the suppliers. 8.0 PACKING: The material shall be suitably packed for the safe dispatch to the consignee. The supplier shall be responsible for all the damages/losses due to improper packing. Replacement shall be made free of cost regarding material pointed out defective by consignee. 9.0 SCHEDULES: The tenderer shall fill in the following schedules, which form the part of tenderer specification and after. If the schedules are not duly filled in with the offer, the offer shall be liable for rejection. Schedule A Guaranteed Technical particulars. Schedule 'B' Schedule of deviation from Specification. Schedule 'C' Schedule of Tenderer s experience. Schedule 'E' Schedule of deviation from specified test requirement. Page 10 of 15

SCHEDULE-A GUARANTEED TECHNICAL PARTICULARS OF MPP TYPE L. T. FIXED CAPACITOR UNITS Sr. No. Parameter Name Parameter type 1. Type of capacitor Text 2. Rated out put in KVAR Text 3. Name of the Manufacturer & Trademark Text 4. Country of manufacture Text 5. Country of origin of Equipment Text 6. Manufacturer s type & description Text 7. Whether ISI Marked Boolean 8. Reference Standard (IS: 13340/1993) with latest amendment if any Text 9. Rated Voltage of each capacitor unit in Volts (440)) Numeric 10. Rated Current in Amp Numeric 11. Rated Frequency in Hz (50) Numeric 12. Phase and connection Text 13. Type of protection (Internal Fuses) Text 14. Maximum over voltage Text 15. Maximum over current Text 16. Insulation level Text 17. Dielectric used Text 18. Type of impregnate used Text 19. Max. temperature rise Text 20. Hot spot temperature rise Text 21. Capacitor loss in Watts/KVAR including Discharge resistor Text (Max. 0.5 watts/ KVAr) 22. Material of container Text 23. Shape of container Text 24. Dimensions of metallic enclosure Diameter (mm) Numeric 25. Dimensions of metallic enclosure Length (mm) Numeric 26. Dimensions of metallic enclosure Breadth (mm) Numeric 27. Dimensions of metallic enclosure Height (mm) Numeric 28. Thickness of metallic enclosure (mm) Numeric 29. Shape of Basic element Text 30. Is capacitor having self healing property (Yes) Text 31. Thickness of film (Microns) Text 32 No of film layers Numeric 33. Voltage Stress (Volts/Microns) Text 34. Voltage rating of each pack Text 35 Type of impregnant used Text 36. Capacitance of Capacitor Unit in microfarad Text 37. Device used per module to control In rush current Text 38 Voltage Proof test (Test Voltage between terminals) Text Page 11 of 15

Sr. No. Parameter Name Parameter type 39. Voltage Proof test (Test Voltage between terminals and container) Text 40. Rating plate provided as per specification & relevant IS Boolean 41. Weight of each capacitor unit Text 42. Whether all the Type test reports as per clause 4.1 of the Boolean specification are submitted 43 Whether submitted drawings Text 44 Whether submitted Quality Assurance Plan Text 45 Whether submitted Test Certificate for raw material Text 46 Any other particulars which the bidder may like to give File Page 12 of 15

SCHEDULE B DEVIATIONS FROM SPECIFICATION Sr. No. Clause No Details of Deviation Page 13 of 15

SCHEDULE C SCHEDULE OF TENDERER's EXPERIENCE The tenderer shall furnish here the list of the similar orders executed/under execution by him to whom a reference may be made by the purchaser in case he considers such reference necessary. Sr.No. Name of the client & description of the order Value of order Period supply & commissioning Name and address to whom ref can be made NAME OF THE FIRM-------------------------------------------------------------------------------------- NAME & SIGNATURE OF THE TENDERER-------------------------------------------------------- DESIGNATION---------------------------------------------------------------------------------------------- DATE----------------------------------------------------------------------------------------------------------- Page 14 of 15

SCHEDULE E SCHEDULE OF DEVIATION FROM SPECIFIED TEST REQUIREMENTS SPECIFIED IN PRESENT SPECIFICATIONS. Sr.No Name of Test Standard No. and Clause No. 1 TYPE TEST 2 ADDITIONAL TEST 3 ACCEPTANCE TEST 4 ROUTINE TEST Requirement of standards Proposed Deviation Reasons for deviation NAME OF THE FIRM-------------------------------------------------------------------------------------- NAME & SIGNATURE OF THE TENDERER-------------------------------------------------------- DESIGNATION---------------------------------------------------------------------------------------------- DATE----------------------------------------------------------------------------------------------------------- Page 15 of 15