R&S ZV-Z5x Calibration Units Specifications

Similar documents
R&S ZV-Z5x Calibration Units Specifications

R&S ZN-Z5x Calibration Units Specifications. Data Sheet V03.00

Vector Network Analyzers ZVB

R&S ZN-Zxxx Calibration Units Specifications. Data Sheet V04.00

R&S ZVT Vector Network Analyzer Specifications

R&S RSC Step Attenuator Specifications

R&S ZNC Vector Network Analyzer Specifications

R&S ZNB Vector Network Analyzer Specifications

R&S ZVT Vector Network Analyzer Specifications

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

R&S ZV-Z135 Calibration Kit Specifications

R&S ZV-Z3xx T-Checker Specifications

R&S FSC Spectrum Analyzer Specifications

R&S EB500 Monitoring Receiver Specifications

R&S FSH4/8 Spectrum Analyzer Specifications

R&S CBT/R&S CBT32 Bluetooth Tester Specifications

R&S SMC100A Signal Generator Specifications

R&S FU129 Antenna Filter Unit Antenna switching, rotator control and signal attenuation, amplification and filtering

R&S ESCI/ESCI7 EMI Test Receiver Specifications

MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp

R&S ZVL Vector Network Analyzer Specifications

Spectrum Analyzer FSL

ENY81 Coupling Network

Signal Generator SMA 100A

Noise Figure Measurement Applications Specifications

RF Signal Generator SM300

R&S CMU-Z10/-Z11 Antenna Coupler/ RF Shielding Cover Simple interference-free testing of all mobiles

Complimentary Reference Material

R&S FSV Signal and Spectrum Analyzer Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Network analysis up to 500 GHz

R&S FSV Signal Analyzer Specifications

R&S ZNA Vector Network Analyzer Specifications

Voltage Sensors URV5-Z

Power Added Efficiency Measurement with R&S ZNB/ R&S ZVA

HF Transmit/Receive Broadband System XB 2900

Attenuators and Matching Pads, Terminations 75 mw to 1000 W, DC to 18 GHz

R&S FS-K112PC NFC Measurement Software Specifications

Analog Modulation Analysis (AM/FM/φM) Specifications


R&S FPC Spectrum Analyzer Specifications

Data Sheet Version R&S RT-ZVCxx Multi-Channel Power Probe Specifications

Noise Figure Measurement in the 60 GHz Range Application Note

FMU36 Baseband Signal Analyzer

Handheld Spectrum Analyzer R&S FSH3

R&S MNT100 RF Interference Locator Specifications

Application Firmware for Phase Noise Measurements FS-K40

Handheld Spectrum Analyzer R&S FSH khz to 3 GHz

ESU EMI Test Receiver

Signal Generator SML

R&S ESRP EMI Test Receiver Specifications

R&S TS8997 Regulatory Test System for Wireless Devices

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay

Spectrum Analyzer R&S FS300

Signal Generator SMA100A

Provided by R&S FSH4/FSH8 Spectrum Analyzer Specifications

R&S ZVH Cable and Antenna Analyzer Specifications

Complimentary Reference Material

Handheld Spectrum Analyzer R&S FSH3

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

R&S FSH Handheld Spectrum Analyzer Where mobility counts

SMA100A Signal Generator

R&S TS-PSAM Analog Source and Measurement Module Scanning multimeter and data acquisition unit

GSM/EDGE Application Firmware R&S FS-K5 for R&S FSP and R&S FSU

Handheld Spectrum Analyzer R&S FSH 3

Spectrum Analyzer FSU

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer

EMI Test Receivers ESIB

R&S SMB100N SIGNAL GENERATOR

R&S FSWP Phase Noise Analyzer Specifications

Signal Generator SMA100A

LabWindows/CVI, VXIpnp driver history for the R&S Radio Tester

R&S FPC-Z10 Teaching Kit Getting Started

R&S OSP Open Switch and Control Platform Specifications

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

HZ530 Near-Field Probe Set

Spectrum Analyzer R&S FSP

R&S FSWP Phase Noise Analyzer Specifications

R&S FSUP Signal Source Analyzer Specifications

R&S NRPC Calibration Kits Calibration of power sensors

Power Meter NRVS. Power, level and voltage measurements from DC to 40 GHz

R&S ZVH Cable and Antenna Analyzer Specifications

R&S UMS175 Compact Radiomonitoring System High performance for outdoor deployment

FSH3 100 khz to 3 GHz FSH6 100 khz to 6 GHz First Edition May 2004i

R&S TS-EMF EMF Measurement System Easy, frequency-selective measurement of EMF emissions

R&S OSP Open Switch and Control Platform Specifications

Frequency range 100 khz to 3 GHz 100 khz to 6 GHz 10 MHz to 18 GHz Reference frequency. 2 ppm in addition 2 ppm/10 C. 0 Hz, 100 Hz to 3 GHz

Guide Version Five techniques for fast, accurate power integrity measurements

Advanced Test Equipment Rentals ATEC (2832)

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc.

R&S NRP USB and LAN Power Sensors Specifications

Appendix A: Specifications

Spectrum Analyzer FSU

Measuring Receiver FSMR

Radio Network Analyzer TSMU/TSMU-H

R&S FSx-K91/-K91n, R&S FSW/FSQ-K91ac WLAN Application Firmware WLAN TX measurements with Rohde & Schwarz analyzers

TSMU/TSMU-H Radio Network Analyzer

R&S SMA100A Signal Generator The new standard of excellence in the analog signal generator class

Transcription:

R&S ZV-Z5x Calibration Units Specifications Test & Measurement Data Sheet 09.01

Specifications apply under the following conditions: Sufficient warm-up time (approx. 15 minutes) at ambient temperature, specified environmental conditions met, calibration cycle adhered to, and all internal calibrations and characterizations performed. Data designated overrange and data without tolerance limits is not binding. Measurement range Impedance Calibration port connector type Number of calibration ports Frequency range 50 Ω R&S ZV-Z51 type N, female or 3.5 mm, female R&S ZV-Z52 3.5 mm, female R&S ZV-Z53 type N, female or 3.5 mm, female R&S ZV-Z54 2.92 mm, female R&S ZV-Z55 2.4 mm, female R&S ZV-Z58 type N, female or 3.5 mm, female R&S ZV-Z59 3.5 mm, female R&S ZV-Z51 4 R&S ZV-Z52 4 R&S ZV-Z53 2 R&S ZV-Z54 2 R&S ZV-Z55 2 R&S ZV-Z58 8 R&S ZV-Z59 6 R&S ZV-Z51 300 khz to 8 GHz R&S ZV-Z52 10 MHz to 24 GHz R&S ZV-Z53 300 khz to 18 GHz or to 24 GHz R&S ZV-Z54 10 MHz to 40 GHz R&S ZV-Z55 10 MHz to 50 GHz R&S ZV-Z58 300 khz to 8 GHz R&S ZV-Z59 10 MHz to 20 GHz 2 R&S ZV-Z5x Calibration Units Version 09.01, February 2009

Calibration time Nominal input level range Damage level Damage DC voltage 4 ports, 201 points, and 1 khz bandwidth 27 s 401 points, and 1 khz bandwidth 34 s 201 points, and 100 Hz bandwidth 67 s 8 ports, 201 points, and 1 khz bandwidth 84 s 401 points, and 1 khz bandwidth 115 s 201 points, and 100 Hz bandwidth 210 s 45 dbm to +20 dbm +23 dbm 12 V Effective system data of the R&S ZV-Z51 This data is valid between +18 C and +28 C, at a measurement bandwidth of 10 Hz, and a nominal power of 10 dbm at the calibration ports. Directivity Source match Reflection tracking Load match Transmission tracking 300 khz to 10 MHz >40 db 10 MHz to 4 GHz >46 db 4 GHz to 8 GHz >40 db 300 khz to 10 MHz >23 db 10 MHz to 4 GHz >40 db 4 GHz to 8 GHz >36 db 300 khz to 10 MHz <0.1 db 10 MHz to 4 GHz <0.04 db 4 GHz to 8 GHz <0.1 db 300 khz to 10 MHz >40 db 10 MHz to 4 GHz >46 db 4 GHz to 8 GHz >40 db 300 khz to 10 MHz <0.2 db 10 MHz to 4 GHz <0.06 db 4 GHz to 8 GHz <0.1 db Version 09.01, February 2009 R&S ZV-Z5x Calibration Units 3

Effective system data of the R&S ZV-Z52 This data is valid between +18 C and +28 C, at a measurement bandwidth of 10 Hz, and a nominal power of 10 dbm at the calibration ports. Directivity Source match Reflection tracking Load match Transmission tracking 10 MHz to 700 MHz >36 db 700 MHz to 8 GHz >40 db 8 GHz to 20 GHz >36 db 20 GHz to 24 GHz >32 db 10 MHz to 700 MHz >30 db 700 MHz to 8 GHz >36 db 8 GHz to 18 GHz >30 db 18 GHz to 24 GHz >26 db 10 MHz to 700 MHz <0.2 db 700 MHz to 8 GHz <0.1 db 8 GHz to 24 GHz <0.15 db 10 MHz to 700 MHz >36 db 700 MHz to 8 GHz >40 db 8 GHz to 20 GHz >36 db 20 GHz to 24 GHz >32 db 10 MHz to 700 MHz <0.2 db 700 MHz to 24 GHz <0.15 db 4 R&S ZV-Z5x Calibration Units Version 09.01, February 2009

Effective system data of the R&S ZV-Z53 This data is valid between +18 C and +28 C, at a measurement bandwidth of 10 Hz, and a nominal power of 10 dbm at the calibration ports. Directivity Source match Reflection tracking Load match 300 khz to 10 MHz >40 db 10 MHz to 4 GHz >46 db 4 GHz to 8 GHz >40 db 8 GHz to 18 GHz >36 db 18 GHz to 20 GHz (3.5 mm only) >36 db 20 GHz to 24 GHz (3.5 mm only) >32 db 300 khz to 10 MHz >23 db 10 MHz to 4 GHz >40 db 4 GHz to 8 GHz >36 db 8 GHz to 18 GHz >30 db 18 GHz to 24 GHz (3.5 mm only) >26 db 300 khz to 10 MHz <0.1 db 10 MHz to 4 GHz <0.04 db 4 GHz to 8 GHz <0.1 db 8 GHz to 18 GHz <0.3 db 18 GHz to 24 GHz (3.5 mm only) <0.3 db 300 khz to 10 MHz >40 db 10 MHz to 4 GHz >46 db 4 GHz to 8 GHz >40 db 8 GHz to 18 GHz >36 db 18 GHz to 20 GHz (3.5 mm only) >36 db 20 GHz to 24 GHz (3.5 mm only) >32 db Version 09.01, February 2009 R&S ZV-Z5x Calibration Units 5

Transmission tracking 300 khz to 10 MHz <0.2 db 10 MHz to 4 GHz <0.06 db 4 GHz to 8 GHz <0.1 db 8 GHz to 18 GHz <0.3 db 18 GHz to 24 GHz (3.5 mm only) <0.3 db Effective system data of the R&S ZV-Z54 This data is valid between +18 C and +28 C, at a measurement bandwidth of 10 Hz, and a nominal power of 10 dbm at the calibration ports. Directivity Source match Reflection tracking Load match Transmission tracking 10 MHz to 20 GHz >36 db 20 GHz to 40 GHz >30 db 10 MHz to 700 MHz >30 db 700 MHz to 20 GHz >34 db 20 GHz to 40 GHz >30 db 10 MHz to 700 MHz <0.15 db 700 MHz to 8 GHz <0.1 db 8 GHz to 40 GHz <0.15 db 10 MHz to 20 GHz >36 db 20 GHz to 40 GHz >30 db 10 MHz to 700 MHz <0.15 db 700 MHz to 8 GHz <0.1 db 8 GHz to 40 GHz <0.15 db 6 R&S ZV-Z5x Calibration Units Version 09.01, February 2009

Effective system data of the R&S ZV-Z55 This data is valid between +18 C and +28 C, at a measurement bandwidth of 10 Hz, and a nominal power of 10 dbm at the calibration ports. Directivity Source match Reflection tracking Load match Transmission tracking 10 MHz to 20 GHz >36 db 20 GHz to 40 GHz >30 db 40 GHz to 50 GHz >26 db 10 MHz to 700 MHz >30 db 700 MHz to 20 GHz >34 db 20 GHz to 40 GHz >30 db 40 GHz to 50 GHz >26 db 10 MHz to 700 MHz <0.15 db 700 MHz to 8 GHz <0.1 db 8 GHz to 40 GHz <0.15 db 40 GHz to 50 GHz <0.2 db 10 MHz to 20 GHz >36 db 20 GHz to 40 GHz >30 db 40 GHz to 50 GHz >26 db 10 MHz to 700 MHz <0.15 db 700 MHz to 8 GHz <0.1 db 8 GHz to 40 GHz <0.15 db 40 GHz to 50 GHz <0.2 db Version 09.01, February 2009 R&S ZV-Z5x Calibration Units 7

Effective system data of the R&S ZV-Z58 This data is valid between +18 C and +28 C, at a measurement bandwidth of 10 Hz, and a nominal power of 10 dbm at the calibration ports. Directivity Source match Reflection tracking Load match Transmission tracking 300 khz to 4 GHz >40 db 4 GHz to 8 GHz >36 db 300 khz to 10 MHz >23 db 10 MHz to 4 GHz >36 db 4 GHz to 8 GHz >32 db 300 khz to 4 GHz <0.1 db 4 GHz to 8 GHz <0.2 db 300 khz to 4 GHz >40 db 4 GHz to 8 GHz >36 db 300 khz to 10 MHz <0.2 db 10 MHz to 4 GHz <0.15 db 4 GHz to 8 GHz <0.3 db 8 R&S ZV-Z5x Calibration Units Version 09.01, February 2009

Effective system data of the R&S ZV-Z59 This data is valid between +18 C and +28 C, at a measurement bandwidth of 10 Hz, and a nominal power of 10 dbm at the calibration ports. Directivity Source match Reflection tracking Load match Transmission tracking 10 MHz to 700 MHz for the R&S ZVT8 >34 db 10 MHz to 700 MHz for the R&S ZVT20 >34 db 700 MHz to 8 GHz >38 db 8 GHz to 20 GHz >32 db 10 MHz to 700 MHz for the R&S ZVT8 >28 db 10 MHz to 700 MHz for the R&S ZVT20 >28 db 700 MHz to 8 GHz >34 db 8 GHz to 20 GHz >28 db 10 MHz to 700 MHz for the R&S ZVT8 <0.3 db 10 MHz to 700 MHz for the R&S ZVT20 <0.3 db 700 MHz to 8 GHz <0.2 db 8 GHz to 20 GHz <0.3 db 10 MHz to 700 MHz >34 db 700 MHz to 8 GHz >38 db 8 GHz to 20 GHz >34 db 10 MHz to 700 MHz <0.3 db 700 MHz to 8 GHz <0.2 db 8 GHz to 20 GHz <0.3 db USB connector USB universal serial bus connector (type B) for connecting the calibration unit with a vector network analyzer of the R&S ZVA/B family, e.g. the R&S ZVB8 Version 09.01, February 2009 R&S ZV-Z5x Calibration Units 9

General data Temperature loading operating temperature range +5 C to +40 C permissible temperature range 0 C to +50 C storage temperature range 40 C to +70 C in line with IEC 60068-2-1 and IEC 60068-2-2 Damp heat +40 C at 85 % rel. humidity Mechanical resistance vibration test, sinusoidal 5 Hz to 150 Hz, in line with IEC 60068-2-6 vibration test, random 10 Hz to 300 Hz, in line with IEC 60068-2-64 shock test 40 g shock spectrum, in line with IEC 60068-2-27, MIL-STD-810 Calibration interval 1 year EMC, RF emission EMC, other emissions and immunity Safety In line with EN 61000-6-4, operation in residential, commercial, and business areas or in small-size companies is not covered. Thus, the instrument may not be operated in residential, commercial, and business areas or in small-size companies unless additional measures are taken to ensure that EN 61000-6-3 is complied with. in line with CISPR 11/EN 55011 group 1 class A (for a shielded test setup) The instrument complies with the emission requirements stipulated by EN 55011 class A. This means that the instrument is suitable for use in industrial environments. in line with IEC/EN 61326; emission: class B; immunity: industrial environment (excluding operating frequency) in line with IEC 61010-1, EN 61010-1, and UL 61010B-1, CSA C22.2 No. 61010.1 10 R&S ZV-Z5x Calibration Units Version 09.01, February 2009

Power supply Power consumption Dimensions (W H D) Weight Shipping weight R&S ZV-Z51, R&S ZV-Z52, 5 V, 500 ma via universal serial bus (USB) R&S ZV-Z53, R&S ZV-Z54, R&S ZV-Z55 R&S ZV-Z58 and R&S ZV-Z59 100 V to 240 V (AC) with tolerance ±10 %, 50 Hz to 60 Hz with tolerance ±5 %, safety class I in line with VDE 411 R&S ZV-Z51, R&S ZV-Z52, 2.5 W R&S ZV-Z53, R&S ZV-Z54, R&S ZV-Z55 R&S ZV-Z58 and R&S ZV-Z59 125 W, typ. 20 W R&S ZV-Z51, R&S ZV-Z52, R&S ZV-Z53, R&S ZV-Z54, R&S ZV-Z55 R&S ZV-Z58 and R&S ZV-Z59 R&S ZV-Z51, R&S ZV-Z52, R&S ZV-Z53, R&S ZV-Z54, R&S ZV-Z55 R&S ZV-Z58 and R&S ZV-Z59 R&S ZV-Z51, R&S ZV-Z52, R&S ZV-Z53, R&S ZV-Z54, R&S ZV-Z55 R&S ZV-Z58 and R&S ZV-Z59 121.0 mm 56.0 mm 155.0 mm (4.8 in 2.2 in 6.1 in) 465.1 mm 108.4 mm 350.0 mm (18.3 in 4.3 in 13.8 in) 750 g (1.7 lb) 5 kg (11 lb) 3 kg (6.6 lb) 13 kg (29 lb) Version 09.01, February 2009 R&S ZV-Z5x Calibration Units 11

Ordering information Designation Type Order No. Calibration Unit, 300 khz to 8 GHz, R&S ZV-Z51 1164.0515.70 4 ports, type N (f) Calibration Unit, 300 khz to 8 GHz, R&S ZV-Z51 1164.0515.30 4 ports, 3.5 mm (f) Calibration Unit, 10 MHz to 24 GHz, R&S ZV-Z52 1164.0521.30 4 ports, 3.5 mm (f) Calibration Unit, 300 khz to 18 GHz, R&S ZV-Z53 1164.0473.72 2 ports, type N (f) Calibration Unit, 300 khz to 24 GHz, R&S ZV-Z53 1164.0473.32 2 ports, 3.5 mm (f) Calibration Unit, 10 MHz to 40 GHz, R&S ZV-Z54 1164.0467.92 2 ports, 2.92 mm (f) Calibration Unit, 10 MHz to 50 GHz, R&S ZV-Z55 1164.0480.42 2 ports, 2.4 mm (f) Calibration Unit, 300 khz to 8 GHz, R&S ZV-Z58 1164.0638.78 8 ports, type N (f) Calibration Unit, 300 khz to 8 GHz, R&S ZV-Z58 1164.0638.38 8 ports, 3.5 mm (f) Calibration Unit, 10 MHz to 20 GHz, 6 ports, 3.5 mm (f) R&S ZV-Z59 1164.0450.36 12 R&S ZV-Z5x Calibration Units Version 09.01, February 2009

Version 09.01, February 2009 R&S ZV-Z5x Calibration Units 13

Service you can rely on J In 70 countries J Person-to-person J Customized and flexible J Quality with a warranty J No hidden terms Regional contact Europe, Africa, Middle East +49 1805 12 42 42* or +49 89 4129 137 74 customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia/Pacific Certified Environmental System +65 65 13 04 88 Certified Quality System ISO 9001 ISO 14001 DQS REG. customersupport.asia@rohde-schwarz.com NO 1954 QM DQS REG. NO 1954 UM For product brochure, Rohde see PD & 0758.2554.12 Schwarz GmbH & Co. KG and Mühldorfstraße www.rohde-schwarz.com 15 81671 München (search Phone term: +49 Typbezeichnung) 8941290 Fax +49 894129 121 64 www.rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners Printed in Germany (sv) PD 0758.2554.22 Version 09.01 February 2009 R&S ZV-Z5x Data without tolerance limits is not binding Subject to change *0.14 /min within German wireline network; rates may vary in other networks (wireline and mobile) and countries.