ATEX CIE-2 x 2 x 0.75 mm 2 -Twisted Pair (TP)-Cable

Similar documents
Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Excel 15 S7760A COMMAND DISPLAY

Cable I.D. Live. Primary or Secondary In or Out of the Trench TX-Former to TX-Former TX-Former to Meter Energized or Grounded.

EDBEMV!PZi. Ä!PZiä. Electromagnetic compatibility. Global Drive Basic information on controller applications in plants and machinery

1 Introduction. 1.1 General installation information

via cable Route of signal interferences Shielding against radiation

OD4 PRODUCT NAME. user manual. user manual. Conditioning Module. Product Type

Installation instructions and notes on implementation of an intermeshed equipotential bonding system with EMClots

1) The diagrams in the section Assembly notes were provided by Rittal GmbH Co. KG, Herborn and by Invensys Systems GmbH EUROTHERM, Limburg/ Lahn.

Resistance Thermometers Model Series TR7X0, Sheathed Design

VSOF-CS201A. ODP Aerial Closure for Fiber Optic Cable User Manual Rev.1

Installing the 3 Indexer: PRS Standard Tools

EMC filters. Mounting instructions. Date: January 2006

MV protection relay. Installation assistance guide. Sepam ranges

Mineral-insulated resistance thermometers to EN

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome

HE693THM884/888 High Resolution Thermocouple Module Product Specifications and Installation

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

WHY YOU NEED A CURRENT BALUN

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02

B Operating Instructions V1.00/EN/

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

VSOF-BS403A. Splice Closure for Fiber Optic Cable User Manual Rev.3

MIL-STD B (SH) UPDATE

Solution of EMI Problems from Operation of Variable-Frequency Drives

Formula Suspension Fork RCC INSTALLATION AND ASSEMBLY INSTRUCTIONS

Installation guide 971 SmartRadar LTi

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

For Maximum Safety. KEEp it SaFE Even in the Control Cabinets. Single-phase. Three-phase

150Hz to 1MHz magnetic field coupling to a typical shielded cable above a ground plane configuration

Cabtite Cable entry system. Cable entries and Cabtite

Installation guide 873 SmartRadar Control Unit & Antenna Unit

High Resolution Thermocouple Module Product Specifications and Installation Data

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Fiber Splice Box (FSB-D) Installation Instructions

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

COWO. Customer Wall Outlet. 1 General. 2 Kit content. 3 Handling of the box. TC-1203-IP Rev A, Apr

670K9 SORtrax Level Transmitter

ED701 General Industry Pressure Transmitter

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel 0.5U:

Installation guide 877 FDI Field Display & Interface

DS 500/DT 500 Laser sensor measures distances to 18 m on black material in proximity mode

MANUAL HYDROBAR. Manufactured by: Fax: H/US/Hydrobar/ /00 Klay Instruments Page 1

HEAVY DUTY WEIGH FEET KIT. Installation Instructions

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

SKDG Cable Repair Kit Instructions

DO NOT PULL ON THE SHEATH.

Outdoor Enclosure. VIVOTEK Pan/Tilt & Fixed Dome Series. Installation Guide

Bel Stewart Connector

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

TxBlock-USB Transmitter

eye in hell CD 3002 Sensor Manual

SPB-TT and SPB-TS Linear Encoder For Pressbrake applications

Version: 1.0 Revised: 6/8/2011. CBU Assembly Instructions Manual

WELDING POSITIONER PARTS BREAKDOWN DRAWING GP-200

The transducer component converts the measured signal and displays the actual value.

Indumax CLS50/CLS50D. Technical Information

Angle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4..

Installation instructions Dec. 2002

Level Switch NRS 2-50 NRS Original Installation Instructions English

ALM42 ALM46 ALM48 ALM43

1. This is an integrated product combining a bearing with a rotation sensor that detects the speed and direction of rotation.

MANUAL HYDROBAR. Manufactured by: 7991 CZ DWINGELOO 7990 AA DWINGELOO The Netherlands

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Setting Standards Connectors M 16

Condumax W CLS15 and CLS15D

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Wind Transmitter compact xx

SUPERSEDED REVISION. Reasons for reissue of this instruction sheet are provided in Section 7, REVISION SUMMARY.

KNX Powerline PL 110. KNX Association

ph or ORP Transmitter

3 Instructions for Design of Drives in Conformance with EMC Regulations

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Ultramini clever reliability in confined quarters. Simple installation and operation

RADIO ANTI TWO-BLOCK SYSTEM

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

TBX-68S Isothermal Terminal Block

Built-in Amplifier Photoelectric Sensor

Telephone Cable Locating Techniques

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

AC AC AC

KING-GAGE KING. ES2 Liquid Level Transmitter. Installation and Operation Instructions ma Liquid Level Transmitter EX-1834

Instruction Sheet Tool Kit [ ] (for SL Series 110 Jack Connectors)

CONTENTS OVERVIEW. For a complete set of CAD drawing details, please visit LaminatorsInc.com. 1 Essential Equipment. 1 Essential Supplies

Manual. MOVITRAC LTE-B/LTP-B Accessories Braking Resistors, Filters, Chokes, Shielding * _0515*

Bill Ham Martin Ogbuokiri. This clause specifies the electrical performance requirements for shielded and unshielded cables.

Operating Manual. for CUTTING, PERFORATING, BENDING SLB120

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Electronic plugs for valves MSE

Digital Interface Option "OPC-E1-DIO"

LVDT. Inductive Position Transducer. SL Series. Key-Features:

(Assembling Guide supplied by imakr ) with the support of MyMiniFactory.com

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

B Operating Instructions /

LVDT 提夫自控技术 ( 上海 ) 有限公司. Series SL ø 20 mm. Inductive Position Transducer. ranges mm. linearity up to 0,20 % housing ø 20 mm

Transcription:

ATEX CIE-2 x 2 x 0.75 mm 2 -Twisted Pair (TP)-Cable Cable routing and connection instructions For signal transmission from PXD Sensors and/or AISC Equipment (Suppressors) to the Control Panel, preferably a shielded twisted pair cable (ATEX CIE) should be used. Connect the outgoing and return line (+/ -) to a twisted pair (see below). Example: a) PXD Sensor connection: ATEX CIE (TP) 2 x 2 x 0,75mm 2 NOTE: PXD circuits are intrinsically safe! Follow instructions for cable routing of intrinsic safe circuits. b) AIS-Suppressor-Connector:

All cable screens should be tied to high frequency ground (EN 60204-1) on both ends (*unless otherwise noted!) no pigtails! The cable screen should be continuous from the transmitter to the receiver. All the earthing connections should be as short as possible. Screen should be earthed on both ends. EMC cable glands are attached to all ATEX components. The screen has to be connected as shown in the pictures below (shield bonded 360 )! Connection Type Lapp Assembly instruction: 1) Cut off outer cable sheath and expose braided screen over a length of approx. 10 15 mm, depending on the cable diameter. 2) Push dome nut and lamellar insert with sealing ring on to the cable. 3) Bend braided screen outwards at a right angle (90 ). 4) Fold braided screen towards outer sheath, i.e. by another 180. 5) Push gland body up to braided screen and turn briefly around both sides of the cable axis. 6) Push lamellar insert with sealing ring into gland body and snap anti-rotation element into place. 7) Firmly screw on dome nut. Connection Type EVG (since July 2007)

High frequency grounds are not equal to safety grounds according to VDE 0100! EMC ground connectors provide only secondary protection against dangerous contact voltages. Avoid compensation current through the cable shield! Therefore: run separate grounding cable (min. 16mm 2 ) to all field components (see below) and connect it to the Common High Frequency Ground connector. Cable routing: Wiring diagram (example) for ATEX suppression system with high frequency ground network: High Frequency (HF) Ground Network (star configuration)

Cable routing is very important for the EMC suitability of an installation. The cables should be classified into four groups: I, II, III and IV Group I: Group II: Group III: Group IV: Very susceptible (analog signals, instrument lines) Susceptible (digital signals, sensor cables, 24 VDC switching signals, communication signals, e.g. field busses) Noise source (control cables for inductive loads, unswitched power cables, motor breakers, contactors) Strong noise sources (output cables of frequency converters, supply cables for welding equipment, switched power cables)

HF-Ground connection PXD Junction Box HF-Ground connection AIS-Suppressor HF-Ground connection Control Panel Type AE HF-Ground connection for Suppressor Junction-Box maintain sufficient distance between noise carrying and susceptible cables (> 10cm) Common High Frequency Ground connector

Avoid ground loops: Checklist: o Noise carrying and susceptible cables properly classified? o and never routed in the same cable duct? o Distance between noise carrying and susceptible cables > 10cm? o Do noise carrying and susceptible cables cross at right angle? o Are noise carrying and susceptible cables shielded? o Are metal cable ducts with cut-off bridges attached used? o Are metal cable ducts connected to each other and to high frequency ground with full contact? o Are unshielded cables routed in the corner of metal cable ducts? o Are long shielded cables grounded several times? o Are shielded cables grounded at both ends? o Are outgoing and return lines routed together over the entire length? o All connection cables straight (no pigtails)? o Contact points bare and grease-free? o Can HF compensation currents flow back through the construction frame? o Are compensation currents prevented from flowing through cable shields? o Are all electrical components routed to the same HF-Ground Network separately (star configuration)? Revision 0.0/06.2009