Honeywell. Overload protection is provided for the transformer. Large 38 VA transformer to power heatingcooling low voltage control systems.

Similar documents
Honeywell. Overload protection is provided for the transformer. Large 38 VA transformer to power heatingcooling low voltage control systems.

General Purpose Relays Types K, R, N, and C

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

OPEN STYLE POWER RELAYS

Spring Return DuraDrive Proportional Actuator

Michigan State University Construction Standards WIRING DEVICES PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Open Type Without Enclosure

DPC F - P3-24. Part Number Scheme. Dimensions

RU Series Universal Relays

Magnecraft Printed Circuit Board & Reed Relays. Catalog

W7100A-E Discharge Air Controller

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Open Type Without Enclosure

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Steps for Selecting the Proper Transformer

Customer witness testing guide

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

G2RL-1A G2RL-1 G2RL-2A G2RL-2

SECTION 1 SOCKET COMPATIBLE AND FLANGE MOUNTED RELAYS 1 TO 30 AMPERES

GENERAL PURPOSE RELAYS

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

SPST-NO SPDT DPST-NO DPDT

INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY

www. ElectricalPartManuals. com Basler Electric -.. BE1-810/U DIGITAL FREQUENCY RELAY ADDITIONAL INFORMATION INSTRUCTION MANUAL

KRPA, KRP, KA, KR series

NEMA Contactor and Starter Specifications

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

Power Supplies for every application

FDM Medium Voltage Controller

3.0 CHARACTERISTICS. Type CKO Overcurrent Relay. switch, which allows the operation indicator target to drop.

3RA13, 3RA14 Contactor Assemblies

Legacy Printed Circuit Board & Reed Relays. Catalog

OUTDOOR TRACK (PATENT PENDING)

3RH1 contactor relays, 4- and 8-pole

BDC30A SERIES BRUSHLESS SERVO AMPLIFIERS Models: BDC30A8, BDC40A20

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

62 Series - Power relays 16 A. Features / /

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Variable Transformers Product Design & Engineering Data

SPST-NO SPDT DPST-NO DPDT

Contents. Volume 7 Motor Controls, Logic and Connectivity CA E April V7-T40-187

Legacy Printed Circuit Board & Reed Relays. Catalog

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.

FEATURES OPTIONAL FEATURES

PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED

Section 2 Outdoor Voltage Transformers

MODEL 421 Over/Under Motor Load Monitor

Table of Contents. CII Mid-Range Relays

alternating relays catalog a of products com

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

m m m Secondary RMS Rating Series Output

General Specifications for Unit Substations

Sealed Interface Control: EC20300

24 HOUR TIME CONTROLS

VE 12 H M S E K HV VD (a) ( * ) (b) (c) (d) (e) (f) (g) (h) (i)

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Fan and Pump AC Inverter

LA-5000 SERIES LINEAR VALVE ACTUATORS


7000 Series Bronze Globe Valves Two-Way Normally Open

POWER RELAYS CONTINUOUS DUTY, TYPE II, UNSEALED INTERMITTENT DUTY, TYPE III, UNSEALED

Flag indicator. Units. V Resistive Resistive Resistive HP HP Pilot Duty ma ~ ~ ~ ~ V V VA W. (Resistive) ms Vrms Vrms Vrms. C C g-n g-n. grams 1.

Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty.

SENSOTEC UNIVERSAL INLINE TRANSDUCER AMPLIFIER BIPOLAR VOLTAGE MODEL. $!}~ f?(' 7. ()ept 1200 CHESAPEAKE AVE" COLUMBUS OHIO (614)

ESC11 SCOOP PROOF SERIES PRODUCT CATALOG

HARTMAN Lightweight High Performance DC Contactors

! CAUTION D TABLE 1

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

Wiring Information. Blinds & Shades

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Electro-Mech Scoreboard Co. Product Guide

B15A SERIES BRUSHLESS SERVO AMPLIFIERS Models: B12A6, B15A8

NEMA Size 1 Cat. No. CN55DN3AB

DPDT MJN2CF-IN* MJN2C-IN 3PDT MJN3CF-IN* MJN3C-IN Latching Plug-in DPDT MJN2CK

Electricity Fundamentals Training System

SmartZone-2 & SmartZone-4

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc

DX450 Red-D-Arc PARTS LIST FOR RETURN TO MAIN INDEX

Safety Relay Unit. OFF-delay time

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

MA-1400 MA Professional Power Amplifier: MA Operating Instructions MA-1200 CH 2 CH 1 CH 1 CH 2 I I I I I I I I I I I I I I I I I I I I

- Wiring Brochure Universal Reset Module 423e

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors

All drive and motor parameters are stored in nonvolatile. Features

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

Power Supplies 3. SDN-C Compact DIN Rail Series

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

62.22 Copper side view

Subminiature Automotive Relays Type CV20 Monostable

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

DU3 Ultrasonic Vehicle Detector

Transcription:

Honeywell R829 FAN CENTER OR AT72H,J TRANS- FORMER (WTH APPROPRATE RELAY), PROVDES LOW VOLTAGE CONTROL OF LNE VOLTAGE FAN MOTORS AND AUX- LARY CRCUTS N HEATNG, COOLNG, OR HEATNG-COOLNG SYSTEMS. AT72H,J Transformer provides for addition of cooling at later date without expensive rewiring by simply plugging in an R8222 (/4 hp) or an R8228 ( hp) Switching Relay. Overload protection is provided for the transformer. Large 8 VA transformer to power heatingcooling low voltage control systems. Low voltage terminal board provides convenient connections for thermostat, and heating and cooling equipment control circuit wiring. o Mounts on standard 4 inch square junction box. Relay in R829 is mounted in a receptacle and can easily be replaced without disturbing wiring. R829, with completely enclosed relay, can be mounted in any indoor location without additional enclosure. Meets NEMA ST2-97 Standard Residential Controls-Class 2 Transformers, marked NEMA Type D. R.E. REV. 6-78 (.08)

TRADELNE MODELS TRADELNE models are selected and packaged to provide ease of stocking, ease of handling and maximum replacement value. TRADE LNE model specifications are the same as standard models. TRADEL NE models: hp fan application. R829A Fan Center spdt switching; 8 VA trans- R829H Fan Center spdt switching; 8 VA former. For single-speed or 2-speed fan transformer. For - or 2-speed, hp fan application. application. R829B Fan Center dpdt switching; 8 VA trans- Q6AOO7 Plate Mounted Relay Receptacle for former. For total comfort application with installing R8222 and R8228 relays on J-boxes. electronic air cleaner, humidifier and blower ncludes leadwires for dpdt relay, metal relay motor. cover, and labels for spst, spdt, and dpdt R829D Fan Center dpst switching; normally relays. A knockout allows mounting a SUPER open power pole, and normally open pilot TRADELNE AT72D transformer. See Table or duty pole; 8 VA transformer. For l-speed fan TRADELNE Catalog to order appropriate application with an auxiliary circuit. relay. R829G Fan Center spst switching; normally ADDTONAL FEATURES: TRADELNE pack with open pole; 8 VA transformer. For l-speed, cross reference label and special instruction sheet. STANDARD MODELS TABLE R829 MODEL SPECFCATONS R829 REPLACEMENT COMPONENTSa RELAY NPUT SEE FAN TRANSFORMER HORSE- SWTCHNG VOLTAGE WRNG CENTER AND RELAY POWER (V AC) DAGRAM RECEPTACLE R829A AT72H R8222B /4 Spdt Fig. 5 R829B AT72J R8222D /4 Dpdt Fig. 6 R829C AT72H R8222A /4 Spst r N.O. Contact Fig. 7 R829D AT72J R8222U /4 R829E AT 72J R8222F /4 Dpst, N.O. Power Contact, N.O. Pilot DutV Contact 20 or Dpst, N.O. Contact, N.C. Contact R829F AT72J R8222C /4 Dpst, both Contacts N.0. R829G AT72H R8228A lb Spst, N.O. Contact RR7WH ------.... AT77-...... R8228B lb Sr)dt aat72h,j and appropriate relay can be ordered separately. 208/240 bl hp at 20v ac; 2 hp at 240V ac. kfig. 8 Fig.9 Fig. 8 Fig. 7 Fig. 5 * (continued on page ) WHOLESALER OR YOUR DSTRBUTOR, REFER TO THE TRADE LNE CATALOG OR PRCE SHEETS FOR COMPLETE ORDERNG NUMBER, OR SPECFY-. Order number. 2. Transformer primary voltage.. Accessories, if required. F YOU HAVE ADDTONAL QUESTONS, NEED FURTHER NFORMATON, OR WOULD LKE TO COMMENT ON OUR PRODUCTS OR SERVCES, PLEASE WRTE OR PHONE:. YOUR LOCAL HONEYWELL RESDENTAL DVSON SALES OFFCE (CHECK WHTE PAGES OF PHONE DRECTORY). 2. RESDENTAL DVSON CUSTOMER SERVCE HONEYWELL NC., 885 DOUGLAS DRVE NORTH Ml NNEAPOLS, MNNESOTA 55422 (62) 542-7500 (N CANADA HONEYWELL CONTROLS LMTED, 740 ELLESMERE ROAD, SCARBOROUGH, ONTARO MP 2V9) NTERNATONAL SALES AND SERVCE OFFCES N ALL PRNCPAL CTES OF THE WORLD. 2

STANDARD MODELS: AT72H Plate-mounted Transformer-Relay Receptacle use when cooling will be added later. ncludes receptacle and leadwires for spst or spdt relay circuit; less R8222 or R8228 relay and relay cover. See Table to order appropriate relay. AT72J Plate-mounted Transformer-Relay Receptacle use when cooling will be added later. ncludes receptacle and leadwires for dpdt or dpst relay circuit; less R8222 or R8228 relay and relay cover. See Table to order appropriate relay. TRANSFORMER RATNGS: Power Rating 8 VA. Primary Voltage either 20 or 208/240V ac. Open Circuit Secondary Voltage 26 ~.5 volts. Overload Protection nternal. Voltage Frequency 50/60 Hz. CONTACT RATNGS: Contact ratings are for both normally open and normally closed contacts. R829A F. VOLTAGE 20V AC 240V AC Full Load (amp).8 6.9 Locked Rotor (amd) 82.8 4,4 Horse~ower /4 /4 R829G and H. VOLTAGE 20V AC 240V AC Full Load (am~) 6 2 Locked Rotor (amp) 96 72 Horsepower 2 RELAY COL RATNGS: nrush 20 VA maximum. Sealed-9 VA. Wattage 5 watts. Pickup Voltage must pick up below 8 volts. LEADWRE COLOR CODE: FG. 8 VA TRANSFORMER REGULATON CURVES. PLOT DUTY RATNGS FOR R829D PLC)T DUTY POLE: Minimum VA at 24, 20, 240, and 480V ac. Maximum 25 VA at 24V ac, 25 VA at 20, 240, and 480V ac. Resistive amps at 277V ac (0.75 power factor). Powerpile (millivoltage ) The normally open pilot duty contacts are rated for Powerpile (millivoltage) applications: 0.25 amp at 0.25 to 2V dc. TRANSFORMER PRMARY LEADWRE COLOR CODE : 20V Black and white. 208/240V black common: Red 208V. Orange 240V. MODEL SWTCHNG ] POLE LEADWRE COLOR Black common R829A Spdt Red N.O. contact AT72H Black common Red N O. contact R829B Dpdt AT72J Violet common Pole 2 Red/Yellow N.O. contact Yellow N.C. contact R829C %st R829D D pst (power pole) Pole 2 (pilot duty pole) Both leadwires red N.0. contact R829E Dpst Pole 2 Both leadwires red N.C. contact R829F Dpst Pole 2 Both leadwires red N.O. contact R829G Spst R829H Spdt Black common Red N. O. contact 60-202 7

;79 LEADWRES: 9 inch color-coded leadwires. RELAY COL LEADWRE COLOR CODE: 2 blue leads connected to C and G terminals. POWER CONSUMPTON: 7.0 watts maximum. CONTACTS: Silver cadmium oxide. MOUNTNG: Mounts on standard 4 inch square junction box. DMENSONS: See Figs. 2 and. UNDERWRTERS LABORATORES NC. LSTED (for R829A-H): File No. E446, Guide No. XAPX. (R8222A-H): File No. E59779, Guide No. NLDX2. CANADAN STANDARDS ASSOCATON COMPO- NENT RECOGNZED: R829A-H File No. LR620. R8222 (all models) File No. LR5066. EXTERNAL LOAD: R829 and AT72H,J (with R8222 or R8228 relay) will operate the following typical Honeywell relay and/or contactor loads with up to 00 feet of No. 8 gauge wire (50 ft run). The maximum load for each application is: 2 R820 Switching Relays. 2 R850 Contractors. R820 Switching Relay and one R850 Cfmtactnr. --. -. --- -. R850 Contactor and one R809 Thermal Delay Relay. R82O, R822, or R824 Contactor and one R820 Relay. R82O, R822, or R824 Contactor and one R809 Thermal Delay Relay. 4+ [4] t [20 5] [67) ; [86] 4r$l 06 7 =79,48. 2 APPROXMATE R829 AND AT72H WTH RELAY COVER NSTALLATON DMENSONS N NCHE [MLLMETRES]. 4; [4],, A :[86] %[ 06 ( - ;[86,4,,. FG. APPROXMATE AT72+,J NSTALLATON DMENsloNs N NCHES [M LLMETREs. 4

6 [62] 2;[57] ;[86] 4iz[ 06 TRANSFORMER L MOUNTNG HOLE (COVERED) ~DA. [22 _ FG. 4 APPROXMATE Q6Ao0 NSTALLATON DMENSONS N NCHES [Mi LLiMETREs]. MEETS NEMA ST2-97 RESDENTAL CONTROLS- an appropriate R8222 or R8228 relay into an AT72H,J CLASS 2 TRANSFORMER, classification marked tran~forrner. The wiring hookups are similar to Figs. 5-9 NEMA Type D. with the exception of some leadwire colors. Order the ACCESSORES: appropriate relay, using Table. The metal cover, Part The R829 function can be achieved by plugging No. 8705, is available to enclose the relay.. Disconnect power supply to prevent electrical shock and equipment damage. 2. nstaller must be a trained, experienced service technician.. Always conduct a thorough checkout when installation is complete. MOUNTNG The R829, AT72H,J and Q6AOO7 mount on a standard 4 inch square junction box. Make wiring connections in the junction box; then fasten the fan center to the box, placing the junction box screws through notches in the fan center mounting plate. On receptacles without relays, select and mount the appropriate relay (Table ) and attach the relay cover. A label identifying the relay used (furnished with TRADE LNE models) should be applied to the relay cover. NOTE: Relay may be mounted in any position. With the terminals pointing down, pickup voltage is increased by 2 percent. WRNG All wiring must comply with local codes and ordinances. Refer to information furnished with the system equipment or refer to Figs. 5-8 showing internal schematics and typical hookups for the fan centers. For R829F, see Fig. 8; for Q6AOO7, see Fig. 0. When making external connections to the line Underwriters Laboratories nc. listed connectors. ~ SOLATON RELAY ~ i [ : Ll----l PLENUM SWTCH OR OTHER SWTCHNG Al DEVCE ~RMARJ BROWN HEATNG CONTROL RED ~. R829A, H T, L J (l ~,!BLACK~,l[HOT)+ - TWO-SPEED FAN MOTOR [ ~ PROVDE DSCONNECT MEANS AND OVERLOAD PROTECTON AS REQuRED. ~ USE OPTONAL HOOKUP WTH SOLATNG RELAY (DASHED LNE) F HEATNG CONTROL HAS A SEPARATE PDWER suw.ly, SOLATON OF THE POWER SUPPLY MAY ALSO BE ACCOMPLSHED BY USNG SPECAL THERMOSTAT SUB. BASE COMBNATONS WTH SOLATED CRCUTS (SUCH AS T87F-QS9A 47, T84A.Q64A09, T822A.Q6 A07]. REFER TO SpeCifiCatiOn SHEETS FOR DETALS. G. 5 R829A,H TYPCAL HOOKUPWTH 2-SPEED FAN N HEATNG-COOLNG SYSTEM. 60-202 7