FIELD DEVICES PRESSURE

Similar documents
11A Series Absolute Pressure Transmitters

FIELD DEVICES - PRESSURE

Pneumatic Instruments Catalog.

RCM DIRECT READING FLOWMETER

I/A Series Electronic Pressure Transmitters with 4 to 20 ma Analog Output for Absolute and Gauge Pressure Measurement

IAP10/IGP10 TRANSMITTER STRUCTURE CODES 52, 53, 60-63, D5, D6, S5, S6, SH, AND SJ

FIELD DEVICES PRESSURE

FIELD DEVICES CONTROLLERS

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

I/A Series Multivariable Transmitters Model IMV25 for P, DP, and T Measurements w/foxcom, HART, or FOUNDATION Fieldbus Communication

FIELD DEVICES - INDICATOR

Wireless Pressure Transmitter Differential Pressure Models Series XYR 6000 Specifications

Wireless Transmitter Gauge Pressure Models Series XYR 6000 Specifications

IP26 Series Current to Pneumatic Converter

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PRESSURE GAUGES, Section 15130

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f

I/A Series Electronic Pressure Transmitters with HART Communication Protocol for Absolute and Gauge Pressure Measurement

8000A Series Compact Magnetic Flowtubes Wafer Body, Ceramic- or pfa-lined 1.6 to 150 mm (1/16 to 6 in) Line Sizes

Ashcroft Digital Pressure Gauges

with HART Communication Protocol IDP10 Series for Differential Pressure Measurement

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

FUNCTIONAL SPECIFICATIONS

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

General Specifications

All Stainless Steel / SS Case Pressure Gauge

Preface WBPEEUI110504A0

Fisher 646 Electro-Pneumatic Transducers

Fisher 646 Electro Pneumatic Transducer

A New Generation of Pressure Transmitters

Technical Datasheet. Performance Series Pressure Difference Switch Models: 301, 303, 304, 381 & 384. Performance Series. Key Features.

Flow Measurement SITRANS F M

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Your Global Sales Partner

I/A Series Electronic d/p Cell Transmitters with FoxCom Communication Protocol IDP10 Series for Differential Pressure Measurement

Pressure transmitter for general industrial applications Model A-10

Note: Do not bury sulphur dioxide lines Use stainless steel pipe and fittings only where specified on project drawings.

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.

Ground Clamps Cable Tray

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

Pressure transmitter for general industrial applications Model A-10

FIELD DEVICES FLOW PSS 1-2B3 A. Product Specifications. Model CFS25 Coriolis Flowtubes FEATURES

ED701 General Industry Pressure Transmitter

Pressure transmitter For general industrial applications Model A-10

This specification describes the minimum requirements for piping systems for the following service:

IDP25 TRADITIONAL STRUCTURE IDP25 LOW PROFILE STRUCTURE LP2 IDP25 LOW PROFILE STRUCTURE LP1

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

ph or ORP Transmitter

Parts List 4 MODEL T-18 and T-27 Mark II Turbo-Meters

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

AT9000 Advanced Transmitter Gauge Pressure Transmitters

I-VICFLEX.VS1. Victaulic VicFlex Style VS1 Dry Sprinkler WARNING WARNING TECHNICAL DATA BEND CHARACTERISTICS INSTALLATION INSTRUCTIONS SIDEWALL

A New Generation of Pressure Transmitters

This specification describes the minimum requirements for piping systems for the following service:

SATRON VB Pressure Transmitter

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters

This specification describes the minimum requirements for piping systems for the following service:

Series 80 In-Line Mounted Centrifugal Pumps

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Materials (other materials see WIKA diaphragm seal program) Model S-10

Differential Pressure Transmitters

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Data Sheet SS/265VS-EN_1

MATERIAL AND EQUIPMENT STANDARD FOR PRESSURE INSTRUMENTS ORIGINAL EDITION MAY 1993

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Conductivity Analyzer

FIRE PROTECTION PRODUCTS

PAD - Heavy Duty Differential Pressure Trasmitter

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

This specification describes the minimum requirements for piping systems for the following service:

OPTIFLUX 5000 Technical Datasheet

Digital inductive conductivity transmitter

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Absolute Pressure Transmitters

Pressure transmitter For general industrial applications Model A-10

Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

PTG series Smart Pressure Transmitter

LGP Design. Can be ordered separately see specification 34-ST-03-55

Series Smart Pressure Transmitter

Repair Manual 12 PL PILOT

AT9000 Advanced Transmitter Differential Pressure Transmitters

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Electromagnetic flowmeters and switches DWM 1000/2000

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications

Miniature Steam Pty Ltd (Incorporating Live Steam Supplies)

Mid-West. Instrument. Model 142 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

Magnetic Flowmeter Systems

LGP Design. Can be ordered separately see specification 34-ST-03-55

SITRANS P. Transmitters for level. Introduction 1/42. Application

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple

Transcription:

FIELD DEVICES PRESSURE Product Specifications Models 11GM and 11GH Pneumatic Transmitters for Gauge Pressure Measurement 11GM TRANSMITTER 11GH TRANSMITTER The Foxboro brand Models 11GM and 11GH Transmitters accurately measure gauge pressure and transmit a proportional pneumatic output signal to receivers which may be several hundred metres or yards away. WIDE RANGEABILITY Spans are fully adjustable up to a 10:1 ratio, providing wide rangeability in a single instrument. Fewer stand-by transmitters are required. PROVEN DEPENDABILITY The Models 11GM and 11GH Transmitters use the same topworks as other Foxboro Pneumatic d/p Cell Transmitters. This mechanism has been the standard for differential pressure measurement since Foxboro introduced it over 50 years ago. Many thousands of successful, trouble-free installations have demonstrated the exceptional dependability of these outstanding transmitters. ON-LINE CALIBRATION These transmitters are equipped with a vernier range adjustment which allows the operator to select one of several predetermined ranges without removing the transmitter from the process. No other calibration apparatus is required for the predetermined ranges. PRECISE MEASUREMENT Since accuracy is a function of calibrated span, precision is retained even with highly elevated- or suppressed-zero ranges.

Page 2 OPERATING CONDITIONS EASE OF MAINTENANCE AND COMMONALITY OF PARTS The simple design of the topworks and the field-replaceable sensing capsules make servicing these transmitters exceptionally easy and economical. In addition, the topworks mechanism of these transmitters is virtually identical to that used in Foxboro pneumatic transmitters, minimizing spare parts inventories and simplifying maintenance routines. OPERATING CONDITIONS Influence Reference Operating Conditions Normal Operating Conditions Operative Limits Ambient Temperature 24 2 C (75 3 F) -40 to +120 C (-40 to +250 F) -45 and +140 C (-50 and +280 F) Process Temperature 24 2 C (75 3 F) 24 2 C (75 3 F) -40 to + 20 C (-40 to +250 F) -40 to + 20 C (-40 to +250 F) -45 and + 90 C (a) (-50 and +357 F) (a) -45 and + 20 C (-50 and +250 F) Supply Pressure 140 1.4 kpa, 20 0.2 psi, or 1.4 0.014 bar 120 to 150 kpa, 18.0 to 22.0 psi, or 1.2 to 1.5 bar 240 kpa, 35 psi, or 2.4 bar a. Topworks temperature must not exceed 120 C (250 F). FUNCTIONAL SPECIFICATIONS Table 1. Span, Range, and Overrange Limits Capsule Span Limits (a) Range Limits (a) (b) Maximum Overrange Pressure Limit Model Code MPa psi MPa psi MPa psi 11GM A 0.07 and 0.56 10 and 80-0.1 and +0.6-15 and +90 0.7 100 B 0.14 and 1.4 20 and 200-0.1 and +2.4-15 and +350 3.5 500 C 0.3 and 2.8 40 and 400-0.1 and +5-15 and +750 7 1,000 D 0.7 and 7 100 and 1,000-0.1 and +10-15 and +1,500 14 2,000 E 1.4 and 14 200 and 2,000-0.1 and +20-15 and +3,000 28 (c) 4,000 (c) 11GH K 7 and 40 1,000 and 6,000-0.1 and +40-15 and +6,000 62 9,000 N 14 and 80 2,000 and 12,000-0.1 and +80-15 and +12,000 124 18,000 a. For values in bar or kg/cm2, multiply MPa values by 10. b. Non-zero based ranges may requires the optional zero elevation kit or suppression kit. See Elevation and Suppression. Upper and lower range-values must not fall outside the range-limits. c. With Monel capsule, maximum overrange pressure limit is reduced to 21 MPa (3,000 psi; 210 bar or kg/cm 2 ).

FUNCTIONAL SPECIFICATIONS (CONT.) Page 3 FUNCTIONAL SPECIFICATIONS (CONT.) Elevation and Suppression With Optional Kits The sum of zero suppression plus calibrated span must not exceed the upper range limits shown in Table 1. Zero may be elevated to provide lower range values down to the lower range limit. Zero may be suppressed to a maximum of 900% of minimum span (700% for Capsule Code A). Zero may be suppressed to a maximum of 500% of minimum span. Typical Range for Zero Suppression 0.14 to 0.7 MPa, 20 to 100 psi, or 1.4 to 7 bar or kg/cm 2. Typical Range for Zero Elevation -0.07 to +0.07 MPa, -10 to +100 psi, -0.7 to +7 bar or kg/cm 2. Output Signal 20 to 100 kpa, 3 to 15 psi, or 0.2 to 1.0 bar or kg/cm 2, as specified. Air Consumption Under Normal Operation 0.42 m 3 /h (0.25 cfm) at standard conditions. Mounting Bracket for mounting on a vertical or horizontal nominal 50 mm (2 in) diameter pipe. Mounting Position These transmitters may be mounted in any position. Air Connections The supply and output connections are tapped for 1/4 NPT. Process Connections Refer to MODEL CODE - 11GM TRANSMITTER and MODEL CODE - 11GH TRANSMITTER. Without Optional Kits Using the zero adjustment, zero may be elevated or suppressed to 10% of span. Zero elevation or zero suppression requires the appropriate optional kit.

Page 4 PERFORMANCE SPECIFICATIONS Accuracy 0.5% of span See Table 1 Dead Band 0.15% of span 0.1% of span PERFORMANCE SPECIFICATIONS Under Reference Operating Conditions Unless Otherwise Specified 0.15% of span Position Effect Zero shifts caused by tilting these transmitters about the centerline of the process connection may be corrected with the zero adjustment screw. Supply Pressure Effect These transmitters are designed to operate at 140 kpa, 20 psi, or 1.4 bar or kg/cm 2 supply pressure. There is a zero shift of less than 0.2% of span for each 5% change in supply pressure within normal operating limits. Repeatability 0.1% of span with AISI Type 316 stainless steel capsule. 0.2% of span with Monel capsule. 0.15% of span Hysteresis 0.1% of span with capsule codes A, B, C, and D. 2% of span with capsule code E. Ambient Temperature Effect Zero shift in percent of span per 55 C (100 F) change. Span Adjustment (Percent of Model Maximum Span) 11GM 80 to 100 50 to 80 20 to 50 10 to 20 Maximum Zero Shift (Percent of Span) 1.0 1.5 2.5 3.0 11GH Up to 100 3.0 Table 2. Accuracy in % of Span Spans Between Capsule Code K Capsule Code N Accuracy (Percent of MPa psi bar or kg/cm 2 MPa psi bar or kg/cm 2 Span) 7 and 20 1,000 and 3,000 70 and 200 14 and 40 2,000 and 6,000 140 and 400 0.5 20 and 40 3,000 and 6,000 200 and 400 40 and 80 6,000 and 12,000 400 and 800 1.0

PHYSICAL SPECIFICATIONS Page 5 PHYSICAL SPECIFICATIONS Table 3. Material of Construction - Wetted Parts Wetted Parts Materials For Item 11GM-S (a) 11 GM-M (b) 11GM-D (b) 11GH Bourdon Tube Ni-Span C Capsule 316 ss Monel 404 Monel 404 Ni-Span C Connection Block 316 ss Monel 404 316 ss 316 ss Connector Gasket Silicone Elastomer Viton-A Viton-A None a. 11GM-A, -B, -C, -D, or -E. b. 11GM-B, -C, -D, or -E. Material of Construction - Nonwetted Parts Body () Forged 316 ss Cover (Topworks) Blue, high-impact, glass-filled polycarbonate. Case () Cast iron with die-cast low copper aluminum cover. The finish is green urethane paint. Bolting () Alloy steel per ASTM A193 grade B7 or equivalent. See OPTIONAL FEATURES section for 17-4 PH stainless steel bolting. Data Plate Stainless steel data plate fastened to topworks with tapping screws. Includes space for customer tag data up to a maximum of 67 characters and spaces. For additional space, see Optional Customer Tag in Table 4. Approximate Mass 4.5 kg (10 lb) 5 kg (11 lb) Environmental Protection The transmitter has the dust-resistant and weatherproof rating of IP54 as defined by IEC 60529, and, with its constant air purging, provides the environmental protection rating of NEMA 3.

Page 6 OPTIONAL FEATURES OPTIONAL FEATURES When ordering an option, add AS Reference to Model Code. Example: 11GM-CS5-L, AS Reference OS-W. Table 4. AS References Optional Feature Description AS Reference Reverse Output 100 to 20 kpa, 15 to 3 psi, or 1.0 to 0.2 bar or kg/cm 2, as specified TR 15-3 Output Signal Output signal is 3 to 27 psi. Air supply pressure is between 29.5 and 30.5 psi. TR 3-27 Oxygen Service Preparation Transmitter is cleaned, assembled, calibrated, and packaged, in a clean room or using other acceptable alternative facilities. Nuclear Service Cleaning Transmitter is cleaned, assembled, calibrated, and packaged, same as above. Air Supply Sets A wide selection of air supply sets is available to provide filtered, regulated supply air to the transmitter. Test Tee A T-connector tapped for 1/4 NPT and fitted with a shut-off valve is mounted on the transmitter for monitoring the output signal. Pressure Seals Transmitters are available with a variety of field-replaceable filled pressure seal systems. Viton-A Process Wetted Gaskets ptfe Process Wetted Gaskets Lower Spans Stainless Steel Bolting Stainless Steel Mounting Bracket Bolting Ermeto Connectors Air Regulator For only. Capsule and force bar gaskets of Viton-A for chemical resistance. For only. Capsule and force bar seal gasket of ptfe for corrosion resistance. For only. Provides for minimum span of 35 kpa, 5 psi, or 0.35 bar or kg/cm 2. The standard performance specifications and operating condition effects are degraded by factors of up to three. This option cannot be used with the optional Output Signal feature (AS Reference TR 3-27). For only. Type 17-4 PH stainless steel cap screws and nuts for the process connector. For only. 316 ss bolting through the mounting brackets to the transmitter. Permits connecting 6 m tubing to 1/4 NPT air connections: Brass 316 ss For only. Permits connecting 6 mm tubing to 1/4 NPT process connections: Carbon Steel 316 ss For only. Permits connection 12 mm tubing to 1/2 NPT process connections: Carbon Steel 316 ss A wide selection of air supply regulators is available, assembled to the transmitter by Foxboro, to provide filtered, regulated supply air to the transmitter. Suffix letters denote the type (fixed or adjustable) and whether or not the range is included. (Refer to Foxboro.) OS-W NS-C Refer to Foxboro OTT Refer to PSS 3-2C1 A DG-6 DG-7 LD SSB SSB-A ERM-A1BR ERM-A1SS ERM-1CS ERM-1SS ERM-2CS ERM-2SS IAS-XX

MODEL CODE - 11GM TRANSMITTER Page 7 Compliance to NACE Standard MR-01-75 Non-Process Wetted Bolting Compliance with Class II or Standard MR-01-75 Customer Tag Table 4. AS References (Continued) Optional Feature Description AS Reference For with Monel (Code M or D) capsule only. The National Association of Corrosion Engineers (NACE) Standard MR-01-75 (1980 revision) covers metallic requirements for resistance to sulfide stress cracking. This option includes process wetted parts selected to comply with the standard. This option provides non-process wetted bolting in compliance with NACE MR-01-75, Class II. Stainless steel tag wired to transmitter for customer tag data that doesn t fit on data plate. There can be a maximum of 10 lines of data with 40 characters and spaces per line. MR-01 B7M MTS Description MODEL CODE - 11GM TRANSMITTER Model Transmitter 11GM Span Limits 0.07 and 0.56 MPa (10 and 80 psi, 0.7 and 5.6 or kg/cm 2 ) -A 0.14 and 1.4 MPa (20 and 200 psi, 1.4 and 14 bar or kg/cm 2 ) -B 0.3 and 2.8 MPA (40 and 400 psi, 3 and 28 bar or kg/cm 2 ) -C 0.7 and 7 MPa (100 and 1,000 psi, 7 and 70 bar or kg/cm 2 ) -D 1.4 and 14 MPa (200 and 2,000 psi, 14 and 140 bar or kg/cm 2 ) -E Capsule Material 316 ss S Monel (Not available with Span Limits Code A) M Monel Element with 316 ss Connection Block (Not available with Span Limits Code A) D Process Connection Tapped for 1/4 NPT 1 Tapped for 1/2 NPT 2 Tapped for R 1/4 3 Tapped for R 1/2 4 Machined for 9/16-18 Aminco fitting 5 (Not available with Span Limits Code -A or Capsule Material Code M) Optional Selections Elevated-Zero Range Kit -L Suppressed-Zero Range Kit -R Example: 11GM-CS5-L

Page 8 MODEL CODE - 11GH TRANSMITTER Description MODEL CODE - 11GH TRANSMITTER Model Transmitter 11GH Capsule Code and Span Limits 7 and 40 MPa (1000 and 6000 psi, 70 and 400 bar or kg/cm 2 ) -K 14 and 80 MPa (2000 and 12 000 psi, 140 and 800 bar or kg/cm 2 ) -N Wetted Parts Ni-Span C Element with 316 ss connection C Process Connection Tapped for 1/2 NPT 2 Tapped for R 1/2 4 Machined for 9/16-18 Aminco Fitting 5 Optional Selections Elevated-Zero Range Kit -L Suppressed-Zero Range Kit -R Example: 11GH-KC2-R

DIMENSIONS-NOMINAL Page 9 DIMENSIONS-NOMINAL Figure 1. 11GM Transmitter mm in 11GM TRANSMITTER 119 4.7 ALLOW CLEARANCE 150 mm (6 in) FOR COVER REMOVAL 110 4.3 368 14.5 229 9.0 165 6.5 ALLOW CLEARANCE 150 mm (6 in) FOR ZERO ADJUSTMENT PNEUMATIC CONNECTIONS TAPPED FOR 1/4 NPT PRESSURE CONNECTIONS 1/4 NPT 1/2 NPT 9/16-18 AMINCO ATMOSPHERIC VENT SUPPLY OUT 25 1.0 MOUNTING BRACKET HORIZONTAL NOMINAL 50 mm (12 in) PIPE (SUPPLIED BY USER) 51 2.0 102 4.0 VERTICAL NOMINAL 50 mm (12 in) PIPE (SUPPLIED BY USER)

Page 10 DIMENSIONS-NOMINAL Figure 2. 11GH Transmitter mm in 11GH TRANSMITTER ALLOW CLEARANCE 150 mm (6 in) FOR ZERO ADJUSTMENT 340 13.4 159 6.3 119 4.7 PNEUMATIC CONNECTIONS TAPPED FOR 1/4 NPT 110 4.3 SUPPLY OUT 25 1.0 SUPPLY OUT ALLOW CLEARANCE 150 mm (6 in) FOR COVER REMOVAL HORIZONTAL NOMINAL 50 mm (12 in) PIPE (SUPPLIED BY USER) PRESSURE CONNECTION TAPPED FOR 1/4 NPT R1/2 9/16-18 AMINCO FITTING 84 3.3 VERTICAL NOMINAL 50 mm (12 in) PIPE (SUPPLIED BY USER) BLOW-OUT PLUG

NOTES Page 11 NOTES

Page 12 ORDERING INSTRUCTIONS 1. Model Number 2. Output Signal 3. Calibrated Pressure Range 4. Optional Selections 5. Tag OTHER FOXBORO PRODUCTS The Foxboro product lines offer a broad range of measurement and instrument products, including solutions for pressure, flow, analytical, temperature, positioning, controlling, and recording. For a list of these offerings, visit our web site at: www.fielddevices.foxboro.com Invensys Systems, Inc. 10900 Equity Drive Houston, TX 77041 United States of America http://www.invensys.com Global Customer Support Inside U.S.: 1-866-746-6477 Outside U.S.:1-508-549-2424 Website: http://support.ips.invensys.com Copyright 1987-2015 Invensys Systems, Inc. All rights reserved. Invensys, Foxboro and d/p Cell are trademarks of Invensys Limited, its subsidiaries, and affiliates. All other trademarks are the property of their respective owners. Invensys is now part of Schneider Electric. 0115