ESR-1129 Reissued June 1, 2011 This report is subject to renewal in two years.

Similar documents
ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF PANELS REPORT HOLDER:

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: IKO INDUSTRIES LIMITED

ICC-ES Evaluation Report Issued February 1, 2011 This report is subject to re-examination in one year.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER:

TECHNICAL BULLETIN NEW ICC ES EVALUATION REPORT

ES Report GAF-Elk Shingle Roof Covering Systems ESR-1475

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054

eco-shake INSTALLATION INSTRUCTION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054

PROJECT INSTRUCTIONS Roofing

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF EVALUATION SUBJECT:

Star Performance in Every Respect. STRENGTH. BEAUTY. EFFICIENCY. YOU CAN HAVE IT ALL WITH METALWORKS.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: CERTAINTEED CORPORATION EVALUATION SUBJECT:

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

ROOFING City of Grand Rapids Building Safety Division

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

RED DIAMOND SHINGLES Roof Installation Introduction:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

ESR-1271* Reissued September 1, 2013 This report is subject to renewal July 1, 2015.

REPORT HOLDER: JAACO CORPORATION NORTHEAST 68 TH STREET, SUITE C-130 REDMOND, WASHINGTON EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: CERTAINTEED CORPORATION

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

ESR-1799 Reissued June 1, 2009 This report is subject to re-examination in one year.

ROOFING APPLICATION STANDARD (RAS) No. 130

ESR-1799 Reissued April 2014 This report is subject to renewal June 1, 2015.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: MiTek USA, INC.

SG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application

ICC-ES Evaluation Report Reissued June 1, 2011 This report is subject to renewal in one year.

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Joint Evaluation Report

Trusted ICC ES PASLODE, Evaluation. report, or as to any. ICC-ES Evaluation

B. Related Sections: The following Sections contain requirements that relate to this Section:

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Revised September 2003

Turada Hardwood Shingles and Shakes Installation instructions

ICC-ES Evaluation Report

Steel Shingle Installation Guide

SECTION SLATE SHINGLES. 1.1 SUMMARY A. Section Includes: 1. Slate shingles over underlayment nailed to roof sheathing.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: ASTROTECH STEELS PRIVATE LIMITED

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

REPORT HOLDER: INTERCORP DBA OF U.S. NITTO 641 NORTH POPLAR ORANGE, CALIFORNIA EVALUATION SUBJECT: STRONG POINT SCREWS

WOODSTART STARTER SHINGLE, STARTER STRIP PLUS, STARTER STRIP SHINGLE, AND TRI BUILT STARTER STRIP

DIRECTIONS FOR APPLICATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: SCREW PRODUCTS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FASTENINGS DIVISION: FINISHES SECTION: FASTENERS REPORT HOLDER:

*Revised September 1, 2003

ENDUREED VIVA SERIES Specifications

REPORT HOLDER: SENCO BRANDS INC IVY POINTE BOULEVARD CINCINNATI, OHIO EVALUATION SUBJECT: SENCO SELF-DRILLING AND SELF-PIERCING SCREWS

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

A P P L I C A T I O N I N S T R U C T I O N S

PRODUCT EVALUATION Effective July 1, 2009 RC-204

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

ESR-2024* Reissued September 1, 2011 This report is subject to renewal September 1, 2013.

HERITAGE LAMINATED ASPHALT SHINGLES Frederick, MD

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

ESR-3042* Reissued August 1, 2012 This report is subject to renewal September 1, 2014.

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

REPORT HOLDER: SFS INTEC 1045 SPRING STREET WYOMISSING, PENNSYLVANIA EVALUATION SUBJECT:

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

CITY OF LOS ANGELES CALIFORNIA

StormMaster Slate General Instructions 1.) GENERAL INSTRUCTIONS 2.) ROOF DECK VENTILATION 3.) ROOF DECK

DECRA Shingle Installation Guidelines

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIRECTIONS FOR APPLICATION

PREMIUM LAMINATED ASPHALT SHINGLES Frederick, MD

DIRECTIONS FOR APPLICATION

Brava Old World Slate Installation Guide

1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights

ASPHALT T E C H N O L O G I E S

The new steep-slope manual

Oklahoma Uniform Building Code Commission 2401 NW 23 rd, Suite 2F Oklahoma City, OK Phone: Fax:

Slate Shingle Specifications

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.

SECTION WOOD SHINGLES

IRONWOOD SHAKE & FLASHING SPECIFICATIONS

RESIDENTIAL ROOFS ADDENDUM NUMBER ONE. August 28, 2017

Product Evaluation Report

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: ELCO CONSTRUCTION PRODUCTS 1032 KERR DRIVE DECORAH, IOWA 52101

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

1.04 QUALITY ASSURANCE

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

b) Symphony comes pre-packaged in color and width blends. There is no need to mix Symphony at the job site. Currently Symphony is available in the

HERITAGE LAMINATED ASPHALT SHINGLES Tuscaloosa, AL

Installation Guide. Titan Old World Slate REV Titan Manufacturing Phone: (407) Fax: (866)

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

ICC-ES Evaluation Report

Installation Guide. Cedar Shake. Distributed by: BEST MATERIALS LLC, Phoenx AZ

IRONSTONE SLATE & FLASHING SPECIFICATIONS IRONSTONE SLATE

4. Metal roof jacks at penetrations and attachments

F-WAVE REVIA SYNTHETIC ROOFING SHINGLES

Hatteras Shingles. CertainTeed Shingle Applicator s Manual. YOUR OBJECTIVE: To learn the correct procedures for installing Hatteras shingles

Transcription:

ICC-ES Evaluation Report ESR-1129 Reissued June 1, 2011 This report is subject to renewal in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 31 16 Metal Shingles REPORT HOLDER: TAMKO BUILDING PRODUCTS, INC. POST OFFICE BOX 1404 JOPLIN, MISSOURI 64802 (417) 624-6644 www.tamko.com EVALUATION SUBJECT: METALWORKS STEEL ROOFING SHINGLES: ASTONWOOD, STONECREST SLATE AND STONECREST TILE 1.0 EVALUATION SCOPE Compliance with the following codes: # 2006 International Building Code (IBC) # 2006 International Residential Code (IRC) # 1997 Uniform Building Code (UBC) Properties evaluated: # Roof covering fire classification # Wind uplift resistance # Weather resistance 2.0 USES The MetalWorks Steel Roofing Shingles (AstonWood, StoneCrest Slate and StoneCrest Tile) covered in this report comply with IBC Section 1507.5, IRC Section R905.4 and UBC Section 1507.8. The shingles are recognized as Class A or Class C roof covering assemblies on new or existing roofs, when installed in accordance with this report. 3.0 DESCRIPTION 3.1 General: The MetalWorks AstonWood, StoneCrest Slate and StoneCrest Tile metal shingles are pressure-formed from nominally 0.0135-inch-thick (0.34 mm) sheet steel complying with ASTM A 653, Grade CS, Type B, having a G90 galvanized coating complying with ASTM A 90. The exterior face is coated with an anticorrosive primer plus a polymer top coat. The interior is coated with an anticorrosive primer plus a wash coat. The shingles are formed by an automated multistage die and have factoryformed interlocking edges at the perimeter. See Figure 1 for additional details. 3.2 AstonWood Shingles: The AstonWood shingles are nominally 12 5 / 8 inches (321 mm) long by 39 3 / 4 inches (1010 mm) wide, and are textured to resemble wood shakes. Each shingle has a nominal weight of 2 pounds (0.9 kg), and an installed weight of 0.61 pound per square foot (2.98 kg/m 2 ). 3.3 StoneCrest Slate and StoneCrest Tile Shingles: The StoneCrest shingles are nominally 12 5 / 8 inches (321 mm) long by 39 3 / 4 inches (1010 mm) wide. The StoneCrest Slate shingles are textured to resemble slate and the StoneCrest Tile shingles are textured to resemble tile. Each shingle has a nominal weight of 2.5 pounds (1.13 kg) and an installed weight of 0.74 pound per square foot (3.61 kg/m 2 ). 3.4 Accessories: Accessories are formed from the same material and include ridge/hip cap, starter/eave flashing, J-channel, sidewall flashing, gable/rake flashing, and valley flashing. See Figure 2 for additional details. 3.5 Nailing Clips: Nailing clips used to fasten the shingles to the sheathing are formed from G90 galvanized 0.015-inch-thick (0.4 mm) steel. See Figure 1 for additional details. 3.6 Fasteners: Fasteners used with the nailing clips to attach the shingles and flashing to the sheathing shall be minimum No. 11 gage [.0120-inch-diameter shank (3.05 mm)], smooth or ring-shank, galvanized roofing nails having a minimum 3 / 8 - inch (9.5 mm) head diameter. Fasteners shall be long enough to penetrate 3 / 4 inch (19 mm) into or through the thickness of the plywood sheathing. 3.7 Underlayment: Underlayment must comply with ASTM D 226, Type II (IBC or IRC) or Type 30 (UBC), asphalt-saturated felt, or must be TAMKO s TW Metal and Tile Underlayment (ESR-2531) or TAMKO s TW Underlayment (ESR-1252). 4.0 INSTALLATION 4.1 Roof Slope: The shingles are installed on minimum roof slopes of 3:12 (25% slope). 4.2 Installation New Construction Class C: The MetalWorks shingles are installed in accordance with the manufacturer s published installation instructions. The shingles are installed over code-complying, minimum 15 / 32 - inch-thick (11.9 mm) plywood sheathing installed in accordance with the applicable code. A full-width layer of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2011 Page 1 of 6

ESR-1129 Most Widely Accepted and Trusted Page 2 of 6 Type II (Type 30) underlayment is installed over the sheathing at the eaves, along the roof perimeter. The eave/starter flashing is installed over the underlayment using 1 1 / 2 -inch-long (38 mm), galvanized roofing nails spaced 36 inches (915 mm) on center. A second layer of Type II (Type 30) underlayment is installed over the eave/starter flashing and continued up the roof with overlaps of 2 inches (51 mm) horizontally and 4 inches (102 mm) vertically, and is fastened with 7 / 8 -inch-long (22 mm), corrosion-resistant roofing nails spaced 12 inches (305 mm) on center on the overlaps and in the field. Gable and rake flashing is installed over the underlayment using 1 1 / 2 -inch-long (38 mm), galvanized roofing nails spaced 36 inches (914 mm) on center. The first row of shingles is started at the lower-left eave and interlocks with the eave flashing. Subsequent courses are installed similarly, with staggered patterns as shown in Figure 3. Shingles are attached to the deck using a minimum of three nailing clips per full-width shingle, equally spaced from each end. The nailing clips are fastened to the deck using fasteners described in Section 3.6. See Figure 4 for typical installation details. Valleys are flashed with TAMKO TW Metal and Tile Underlayment or TW Underlayment, beneath the metal valley flashing, in addition to the underlayment required for the field of the roof. The metal valley flashing is fastened to the deck using nailing clips on each side of the flashing, spaced 36 inches (915 mm) on center. Shingles are cut to fit into the valley flashing. Hip and ridge pieces are installed in accordance with the manufacturer s installation instructions. 4.3 Installation New Construction Class A: Installation is as noted in Section 4.2 except that a barrier consisting of minimum 1 / 4 -inch-thick (6.4 mm) Georgia Pacific Dens Deck overlayment board or 1 / 2 -inch-thick (12.7 mm) gypsum sheathing is installed, over the plywood sheathing, with all joints staggered a minimum of 6 inches (152 mm), both horizontally and vertically, from the plywood joints. The Georgia Pacific Dens-Deck or gypsum sheathing is attached with a minimum of six roofing nails per 4-foot-by-8-foot (1219 mm by 2438 mm) sheet, and is installed over the plywood sheathing and under the underlayment. Fasteners used to attach the shingles and the barrier board must be as described in Section 3.6. 4.4 Severe Climate Areas: In areas subject to wind-driven snow, ice buildup, or winddriven dust or sand, or in other areas designated by the code official, both of the following conditions shall apply: Solid sheathing with two layers of ASTM D 226, Type I (IBC and IRC) or Type 15 (UBC) felt for the field of the roof. Solid sheathing with two layers of ASTM D 226, Type I (IBC and IRC) or Type 15 (UBC) felt applied shinglefashion and solid-cemented together with approved cementing material between the plies, extending from the eave up the roof to a point 24 inches (610 mm) inside the exterior wall line of the building under the IBC and the IRC, and 36 inches (914 mm) under the UBC. TAMKO TW Metal and Tile Underlayment or TW Underlayment may be used in lieu of two layers of Type I or Type 15 underlayment solid-cemented together over the eave area noted above. 4.5 Wind Resistance: 4.5.1 IBC and IRC: When installed in accordance with this report, the MetalWorks shingles are limited to installation in Exposure B areas where the maximum basic wind speed is 100 mph (161 km/h) (3-second gust) on structures with a maximum roof height of 40 feet (12 192 mm) or less. 4.5.2 UBC: When installed in accordance with this report, the MetalWorks shingles are limited to Exposure B areas subjected to a maximum basic wind speed (fastest mile) of 80 mph (129 km/h) on structures having a mean roof height of 40 feet (12 192 mm) or less. 4.6 Reroofing Installation: 4.6.1 General: If the existing roof covering is completely removed, installation must be in accordance with Sections 4.1 through 4.4 of this report. For the shingles to be installed over existing roofing materials without removal of the existing roof covering, installation must be in accordance with Section 1510 of the IBC, Section R907 of the IRC or Appendix 15 of the UBC. Prior to installation of the new roof covering, the existing hip and ridge materials must be removed and the roof cleaned of any loose gravel or debris. 4.6.2 Reroofing Classification: 4.6.2.1 Class A: When the Class A assembly described in Section 4.3 of this report is installed over an existing Class A, B, or C roof covering, the existing roof covering classification remains unchanged. 4.6.2.2 Class C: When the Class C assembly described in Section 4.2 of this report is installed over an existing Class A, B, or C roof covering that is installed over minimum 15 / 32 -inch-thick (11.9 mm) plywood sheathing, the new roof is a Class C. 4.6.2.3 Installation over Wood Shakes or Shingles: MetalWorks shingles installed over existing wood shingles or shakes is limited to buildings permitted by the applicable code to have nonclassified or nonrated roofing. 5.0 CONDITIONS OF USE The MetalWorks Steel Roofing Shingles described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Products are identified and installed in accordance with this report and the manufacturer s published installation instructions. If there is a conflict between the manufacturer s installation instructions and this report, this report shall govern. 5.2 Only Metalworks steel roof shingle accessories and specified fasteners shall be used in the installation of the roof covering system. 5.3 MetalWorks steel shingles are manufactured in Joplin, Missouri, under a quality control program with inspections by Underwriters Laboratories Inc. (AA- 668). 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Metal Roof Coverings (AC166), dated February 2007. 7.0 IDENTIFICATION Each package of MetalWorks steel roofing shingles shall be labeled with the report holder s name (TAMKO Building Products, Inc.) and address, the product name, the evaluation report number (ESR-1129) and the name of the inspection agency.

ESR-1129 Most Widely Accepted and Trusted Page 3 of 6 FIGURE 1 PANEL/CLIP DETAIL

ESR-1129 Most Widely Accepted and Trusted Page 4 of 6 FIGURE 2 TRIM AND FLASHING DETAILS

ESR-1129 Most Widely Accepted and Trusted Page 5 of 6 FIGURE 3 LAYOUT PATTERNS FIGURE 4 TYPICAL INSTALLATION DETAILS

ESR-1129 Most Widely Accepted and Trusted Page 6 of 6. FIGURE 4 TYPICAL INSTALLATION DETAILS (Continued)