A NEW MAXIMUMPOWER POINT TRACKING METHOD FOR PV SYSTEM

Similar documents
Comparative Study of P&O and InC MPPT Algorithms

Parallel or Standalone Operation of Photovoltaic Cell with MPPT to DC Load

SIMULATION OF INCREMENTAL CONDUCTANCE BASED SOLAR MPPT SYSTEM

Converter Topology for PV System with Maximum Power Point Tracking

Load Controlled Adaptive P&O MPPT Controller PV Energy Systems

CHAPTER-3 Design Aspects of DC-DC Boost Converter in Solar PV System by MPPT Algorithm

Designof PV Cell Using Perturb &Observe and Fuzzy Logic Controller Based Algorithm

A Grid Connected Hybrid Fuel Cell-Po Based Mppt For Partially Shaded Solar Pv System

Finite Step Model Predictive Control Based Asymmetrical Source Inverter with MPPT Technique

ISSN Vol.07,Issue.01, January-2015, Pages:

A NEW APPROACH OF MODELLING, SIMULATION OF MPPT FOR PHOTOVOLTAIC SYSTEM IN SIMULINK MODEL

Photovoltaic Systems Engineering

Comparative study of maximum power point tracking methods for photovoltaic system

Keywords: Photovoltaic, Fuzzy, Maximum Power Point tracking, Boost converter, Capacitor.

Enhanced MPPT Technique For DC-DC Luo Converter Using Model Predictive Control For Photovoltaic Systems

ISSN: X Impact factor: (Volume3, Issue2) Simulation of MPPT based Multi-level CUK converter

A Fast Converging MPPT Technique for PV System under Fast Varying Solar Irradiation and Load Resistance

International Journal of Scientific & Engineering Research, Volume 7, Issue 4, April ISSN

Hardware Implementation of Maximum Power Point Tracking System using Cuk and Boost Converters

Sliding Mode MPPT Based Control For a Solar Photovoltaic system

Perturb and Observe Method MATLAB Simulink and Design of PV System Using Buck Boost Converter

Simulation of Perturb and Observe MPPT algorithm for FPGA

Simulation Analysis of Maximum power Point Tracking in Grid connected Solar Photovoltaic System

MEASURING EFFICIENCY OF BUCK-BOOST CONVERTER USING WITH AND WITHOUT MODIFIED PERTURB AND OBSERVE (P&O) MPPT ALGORITHM OF PHOTO-VOLTAIC (PV) ARRAYS

,, N.Loganayaki 3. Index Terms: PV multilevel inverter, grid connected inverter, coupled Inductors, self-excited Induction Generator.

A Single Switch DC-DC Converter for Photo Voltaic-Battery System

An Interleaved High Step-Up Boost Converter With Voltage Multiplier Module for Renewable Energy System

Implementation of Photovoltaic Cell and Analysis of Different Grid Connection

CHAPTER 4 FUZZY LOGIC BASED PHOTO VOLTAIC ENERGY SYSTEM USING SEPIC

A Survey and Simulation of DC-DC Converters using MATLAB SIMULINK & PSPICE

Voltage-MPPT Controller Design of Photovolatic Array System Using Fuzzy Logic Controller

OPTIMAL DIGITAL CONTROL APPROACH FOR MPPT IN PV SYSTEM

STUDY OF MAXIMUM POWER POINT TRACKING ALGORITHMS AND IDENTIFICATION OF PEAK POWER USING COMBINED ALGORITHM FOR PHOTOVOLTAIC SYSTEM

Comparison Of DC-DC Boost Converters Using SIMULINK

Selective Harmonic Elimination Technique using Transformer Connection for PV fed Inverters

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 2.114

Simulation based study of Maximum Power Point Tracking and Frequency Regulation for Stand-alone Solar Photovoltaic Systems

Model Predictive Control Based MPPT Using Quasi Admittance converters for photovoltaic system

Design And Analysis Of Dc-Dc Converter For Photovoltaic (PV) Applications.

Boost Half Bridge Converter with ANN Based MPPT

Sliding Mode Control based Maximum Power Point Tracking of PV System

Simulation of Standalone PV System Using P&O MPPT Technique in Matlab/Simulink

Voltage Based P&O Algorithm for Maximum Power Point Tracking using Labview

Series connected Forward Flyback converter for Photovoltaic applications

Abstract The performance of a photovoltaic (PV) array is affected by temperature, solar insulation, shading, and array

CHAPTER 3 CUK CONVERTER BASED MPPT SYSTEM USING ADAPTIVE PAO ALGORITHM

Solar Energy Conversion Using Soft Switched Buck Boost Converter for Domestic Applications

Design of Power Inverter for Photovoltaic System

Implementation of P&O MPPT for PV System with using Buck and Buck-Boost Converters

IMPLEMENTATION OF MAXIMUM POWER POINT TRACKING ALGORITHM USING RASPBERRY PI

Shunt Active Power Filter connected to MPPT based photo voltaic Array for PQ enhancement

Maximum Power Point Tracking Using Modified Incremental Conductance for Solar Photovoltaic System

Maximum Power Point Tracking Performance Evaluation of PV micro-inverter under Static and Dynamic Conditions

A Variable Step Size MPPT Method for Stand-Alone PV Energy Systems

Analysis of Photovoltaic Micro-Inverter System using MPPT

FUZZY LOGIC BASED MAXIMUM POWER POINT TRACKER FOR PHOTO VOLTAIC SYSTEM

Because the global warming is increasing and conventional

Development of a Fuzzy Logic based Photovoltaic Maximum Power Point Tracking Control System using Boost Converter

HYBRID SOLAR SYSTEM USING MPPT ALGORITHM FOR SMART DC HOUSE

International Journal of Engineering Science Invention Research & Development; Vol. II Issue VIII February e-issn:

Solar PV Array Fed Four Switch Buck-Boost Converter for LHB Coach

Analysis Of Mathematical Model Of PV Cell Module in Matlab/Simulink Environment

STUDY OF A PHOTOVOLTAIC SYSTEM WITH MPPT USING MATLAB TM

USE OF BY-PASS DIODE IN MAXIMUM POWER POINT TRACKING SYSTEM

Sliding-Mode Control Based MPPT for PV systems under Non-Uniform Irradiation

PHOTOVOLTAIC (PV) generation is becoming increasingly

Maximum Power Point Tracking of Photovoltaic Modules Comparison of Neuro-Fuzzy ANFIS and Artificial Network Controllers Performances

SIMULATION OF A SOLAR MPPT CHARGER USING CUK CONVERTER FOR STANDALONE APPLICATION

VERY HIGH VOLTAGE BOOST CONVERTER BASED ON BOOT STRAP CAPACITORS AND BOOST INDUCTORS USED FOR PHOTOVOLTAIC APPLICATION USING MPPT

MAXIMUM POWER POINT TRACKING OF PV ARRAYS UNDER PARTIAL SHADING CONDITION USING SEPIC CONVERTER

A Current Sensor-less Maximum Power Point Tracking Method for PV

MPPT CONTROL OF PHOTOVOLTAIC SYSTEM USING FLYBACK CONVERTER

Proceedings of 2nd International Multi-Disciplinary Conference December 2016, Gujrat

Design of MPPT Controller using ANFIS and HOMER based sensitivity analysis for MXS 60 PV module

Multiport Converter for Micro Grid Application

MPPT with Z Impedance Booster

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

Adaptive Fuzzy Pid Controller Based Maximum Power Point Tracking For PV Fed DC Motor Drive

DESIGN OF CUK CONVERTER WITH MPPT TECHNIQUE

Analysis of PV Array Solar Energy Using Advanced Hill Climbing Controller

HIGH STEP UP CONVERTER FOR SOLAR POWER USING FLC

MATLAB/Simulink Model of PV Integrated DC-DC Converter

Modeling of PV Interconnected Distribution System using Simulink

A Solar Powered Water Pumping System with Efficient Storage and Energy Management

PV Charger System Using A Synchronous Buck Converter

Sizing and Design of PV Array for Photovoltaic Power Plant Connected Grid Inverter

DESIGN AND IMPLEMENTATION OF SOLAR POWERED WATER PUMPING SYSTEM

Implementation of Buck-Boost Converter with Coupled Inductor for Photo-Voltaic System

A Pv Fed Buck Boost Converter Combining Ky And Buck Converter With Feedback

CHAPTER 5 MPPT OF PV MODULE BY CONVENTIONAL METHODS

Hybrid Power Control Concept for Grid Connected PV Inverter with Reduced Thermal Loading

Dual MPPT Control of a Photovoltaic System

G.Raja Sekhar, Ch.Sai Babu, J.Surya Kumari

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: ,p-ISSN: , PP

INCREMENTAL CONDUCTANCE BASED MPPT FOR PV SYSTEM USING BOOST AND SEPIC CONVERTER

A Variable Step Size Perturb and Observe Algorithm for Photovoltaic Maximum Power Point Tracking

Optimization of Different Solar Cell Arrangements Using Matlab/Simulink for Small Scale Systems

Photovoltaic Controller with CCW Voltage Multiplier Applied To Transformerless High Step-Up DC DC Converter

An Interleaved High-Power Fly back Inverter for Photovoltaic Applications

Speed control of Induction Motor Using Push- Pull Converter and Three Phase SVPWM Inverter

Transcription:

A NEW MAXIMUMPOWER POINT TRACKING METHOD FOR PV SYSTEM Abstract: Gangavarapu Mamatha Assistant Professor Electrical and Electronics Engineering Vignan s Nirula institute of technology and science for women mamatha.eee242@gmail.com Ph no:8106485711 Guntur In the past decades, there has been a huge growth in the use of the renewable energy sources. Photovoltaic energy is one of these sources but, the high cost and low conversion efficiency have limited the use of such endless energy source. Also the output power of a photovoltaic system (PV) is nonlinear and it is affected by weather conditions, therefore the maximum power point tracking (MPPT) was invented to extract the maximum power from each PV array. In this paper two methods are critically reviewed; Perturb & Observe method (P&O) and a new technique of tracking the maximum power point based on P&O are introduced in this paper. In this technique, from the available P-V curve[8]- [10] the present value i.e, power and voltage,obtained is compared with the prior and post value which decreases the probability of error as observed in conventional P&O method. The performance of the the modified P&O method is evaluated and compared with the conventional MPPT method in MATLAB. Keywords: [MPPT] maximum power point tracking; [P&O]Perturb and Observe; [PV] Photovoltaic panel. Introduction: As one of the prominent renewable energy resources, photovoltaic (PV) generation has been increasingly gaining considerable attention among industry players all around the world. In most of the PV applications, the key function of PV system is to extract maximum power from PV array during the daytime. The power-voltage characteristics have nonlinear characteristics that depend on environmental conditions like irradiance and temperature. At each irradiance level, there exists a unique maximum power point of power - voltage curve of PV array. Maximum Power Point Tracking (MPPT) control algorithm of PV power converter is the function to maximize the power generation efficiency by regulating the PV array voltage, i.e. the input voltage of the converter. There have been many algorithms developed for MPPT, e.g. perturbation and observation (P&O) method, the fractional open circuit voltage, short circuit current, 255

the fuzzy logic control among which P&O method is well preferred duo to its ease of implementation and low cost[1]-[4]. Instead of these advantages this method has the drawback of high time and low tracking speed. Therefore new proposed method eliminates these drawbacks by increasing the tracking speed and locating the exact maximum power point. Photovoltaic Module: It is a non-linear device and can be represented as a current source in parallel with diode as shown in the Fig1. Fig1: Equivalent circuit of PV cell The current source I ph represents the cell photocurrent. R sh and R s are the intrinsic shunt and series resistances of the cell, respectively. Usually the value of R sh is very large and that of R s is very small, hence they may be neglected to simplify the analysis. Module photo current, I ph I scr Ki T 298 *λ/1000 (1) Modules reverse saturation current, I rs I scr / exp qvoc / NskAT 1 (2) The module saturation current I o vary with the cell temperature, which is given by, 3 T q * Ego 1 1 I 0 I rs exp (3) Tr Bk Tr T The current output of PV module is I pv N p * I ph N p * I o exp q *( VPV I PV RS ) / Ns AkT 1 (4) Where V pv =V oc,n p 1and N s =36.And The model of PV module is implemented in MATLAB using eq. (1-4) The model yields the PV current I, using the electrical parameter of the module ( I sc,v oc,n ) and the variables Voltage, Irradiation (G ) and Temperature (T) as the inputs to the model. Solar make 36 W PV module is taken as the reference module for simulation and the name-plate details are given in Table 1. 256

Table1: electrical characteristics data of solar 36W PV module Rated power 36W Voltage at maximum power(v mp ) 16.56V Current at maximum power(i mp ) 2.25A Open circuit voltage(v oc ) 21.24V Short circuit current(i sc ) 2.55A Total number of cells in series(n s ) 36 Total number of cells in parallel(n p ) 1 Fig (a): P-V characteristics for different irradiation levels at constant temperature of 25 0 C. Fig (b): I-V characteristics for different irradiation levels at constant temperature of 25 0 C 257

Higher is the solar irradiation, higher would be the solar input to the solar cell and hence power magnitude would increase for the same voltage value. With increase in the solar irradiation the open circuit voltage increases. This is due to the fact that, when more sunlight incidents on to the solar cell, the electrons are supplied with higher excitation energy, thereby increasing the electron mobility and thus more power is generated Fig (c): P-V characteristics for different temperatures at constant irradiation of 1000w/sqm Fig (d): I-V characteristics for different temperatures at constant irradiation of 1000w/sqm On the contrary the temperature increase around the solar cell has a negative impact on the power generation capability. Increase in temperature is accompanied by a decrease in the open circuit voltage value. Increase in temperature causes increase in the band gap of the 258

material and thus more energy is required to cross this barrier. Thus the efficiency of the solar cell is reduced. Boost converter: A dc/dc converter is an integral part of any MPPT circuit system. When a direct connection is carried out between the source and the load, the output of the PV module is irregularly shifted away from the maximum power point. It is necessary to overcome this problem by adding an adaptation circuit between the source and the load. A MPPT controller circuit with a DC-DC converter circuit is used as an adaptive circuit. The boost circuit consist a energy storing element inductor, a capacitor, a diode, a load and a switching device like Mosfet, BJT etc. Circuit diagram of boost converter is shown in figure 2 below. Fig2: Boost Converter The control strategy is based on manipulation the duty cycle of the Mosfet causes the voltage change in Boost converter. Perturb & Observe: Perturb & Observe (P&O) is the simplest method. In this we use only one sensor, that is the voltage sensor, to sense the PV array voltage and so the cost of implementation is less and hence easy to implement. The time complexity of this algorithm is very less but on reaching very close to the MPP it doesn t stop at the MPP and keeps on perturbing on both the directions. When this happens the algorithm has reached very close to the MPP and we can set an appropriate error limit or can use a wait function which ends up increasing the time complexity of the algorithm.the flowchart of P&O algorithm is shown below. 259

Fig3: Flow chart of the P&O method The Perturb & Observe algorithm states that when the operating voltage of the PV panel is perturbed by a small increment, if the resulting change in power P is positive, then we are going in the direction of MPP and we keep on perturbing in the same direction. If P is negative, we are going away from the direction of MPP and the sign of perturbation supplied has to be changed. But, this method has the drawback of high time and low tracking speed. Therefore new proposed method eliminates these drawbacks by increasing the tracking speed and tracking the exact maximum power point Modified Perturb and Observe Method: In this modified P&O method from the available P-V curve the voltage value is increased step-wise corresponding to which the power value is also obtained. Here, with each step-wise incremental, power value is compared with prior and post obtained value, i.e, each time, comparison of three values is done.therefore,the overall comparison is used to track maximum power point. 260

Fig4: Flow chart of the Modified P&O method The major difference between the conventional P&O and MP&O is in the process of comparison. In P&O the post value obtained is compared with present value but not the prior value, hence MP&O compensates the drawback of conventional perturb and observe method, by increasing the tracking speed and decreasing the number of iterations Results and discussions: Tracking of Maximum Power Point P-V characteristics for different irradiation levels at constant temperature of 25 0 C. Fig(e): Tracking of Maximum Power Point using P&O And MP&O Methods for different irradiation levels and constant temperature i.e,25 0 C 261

ISSN:2229-6093 P-V characteristics for different temperatures at constant irradiation of 1000w/sqm. Fig(f): Tracking of Maximum Power Point using P&O And MP&O methods for different temperature levels and constant irradiation i.e,1000w/sqm Comparison of P&O and MP&O MPPT Techniques: MP&O P&O Without MPPT Technique 262

Table2: Comparison of P&O and MP&O: S.no. Technique Time to track MPP for different irradiations(sec) Time to track MPP for different temperatures(sec) Power Conversion Efficiency (%) 1 With perturb and observe 13.492 13.305 29 80.55 2 With modified perturb and observe 4.112 3.795 31 91.67 Conclusion: The comparison between the existing method perturb and observe and proposed method modified perturb and observe method has been done. Here,the results indicate that PV conversion system using modified perturb and observe method which has higher conversion efficiency and it tracks the exact maximum power point at less time with higher tracking speed than perturb and observe method.therefore, the modified Perturb and Observe method was best preferred due to its higher tracking efficiency References: [1] Bidyadhar Subudhi, Senior Member, IEEE, and Raseswar Pradhan. A Comparative Study on Maximum Power Point Tracking Techniques for Photovoltaic Power Systems IEEE Transactions on sustainble energy, vol. 4, no.1, Jan 2013. [2] A. K. Abdelsalam, A. M. Massoud, S. Ahmed, and P. N. Enjeti IEEE Member Highperformance adaptive perturb and observe MPPT technique for photovoltaic-based microgrids, IEEE Trans. Power Electron., vol. 26,no. 4, Apr. 2011. [3] J. Lopez-Seguel, S. I. Seleme, P. Donoso- Garcia, L. F. Morais, P.Cortizo and M. S. Mendes, 2010 IEEE International Conference, Comparison of MPPT Approaches in Autonomous Photovoltaic Energy Supply System Using DSP, Industrial Technology (ICIT), IEEE Transactions. [4] N. Femia, G. Petrone, G. Spagnuolo, and M. Vitelli, vol. 56, no. 11, Nov. 2009. A technique for improving P&O MPPT performances of double-stage grid-connected photovoltaic systems. IEEE Trans. 263

[5] K-J. Lee, B.-G. Park, R-Y. Kim, and D-S. Hyun, Non isolated ZVT two inductor boost converter with a single resonant inductor for high step-up applications. IEEE Trans. Power Electron., vol. 27, no. 4,,Apr. 2012. [6] J. Suryakumari, G. Sahiti, G. Sudhakar Analysis and Simulation of Perturb and Observe Mppt Techniqu International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 Vol. 3, Issue 4, Jul-Aug 2013. [7] M. Pavlov sky, G. Guidi, and A. Kawamura,. Buck/Boost Dc-Dc converter with simple auxiliary snubber and complete soft switching in whole operating region,. Exposition, in Proc. Energy Convers. Cong ECCE 2012. [8] J. Surya Kumari* and Ch. Sai Babu** Mathamatical modeling and simulation of photovoltaic cell using matlab-simulink environment International Journal of Electrical and Computer Engineering (IJECE) Vol. 2, No. 1, February 2012. [9] Paraskevadaki, E.V., Papathanassiou, S.A., Evaluation of MPP Voltage and Power of mc- Si PV Modules in Partial Shading Conditions, IEEE Trans on Energy Conversion,vol. 26 2011. [10] A. Bellini, S. Bifaretti, V. Lacovone, and C. Cornaro, Simplified model of a photovoltaic module, in International Conference on Applied Electronics, Pilsen, Czech Republic, 2009. [11] W. T. Chee, T. C. Green, and A. H.-A. Carlos, Analysis of perturb and observe maximum power point tracking algorithm for photovoltaic applications, presented at the 2008 IEEE 2nd Int. Power and Energy Conf. (PECon 2008), Johor Bahru, Malaysia, 2008. [12] Trishan Esram and Patrick L. Chapman, Comparison of Photovoltaic Array Maximum Power Point Tracking Techniques, IEEE Trans. on Energy Conversion, vol. 22, no. 2, pp. 439-449,June 2007. [13] A. Pandey, N. Dasgupta, and A. K. Mukerjee, A simple single-sensor MPPT solution, IEEE Trans. Power Electron., vol. 22, no. 6, pp. 698 700, Mar. 2007. [14] V. Salas, E. Olias, A. Barrado, and A. Lazaro, Review of the maximum power point tracking algorithm for stand-alone photovoltaic system, Solar Energy Mater. Solar Cells, vol. 90, no. 11, pp. 1555 1578, 2006 [15] Y. Chen, K. Smedley, F. Vacher, and J. Brouwer, A new maximum power point tracking controller, in Proc. 18th Annu. IEEE Conf. Appl. Power Electron. Conf. Expo., Florida, 2003. 264