Finer Points of ICP-OES Setup and Operation

Similar documents
Stop Worrying About Interferences With These ICP-OES Solutions

AutoMax Fast, automated method optimization

The Latest Advances in Axially Viewed Simultaneous ICP-OES for Elemental Analysis

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design

Diode Laser Systems In Gas Measurement

Simplicity. Reliability. Performance. ProdigyPlus

Directions for running IC samples on the Shimadzu TOC analyzer. (5/18/2015 DER)

Aurora Group of Companies

For Client Review Only. All Rights Reserved. Advanstar Communications Inc. 2005

Preparing Remote Sensing Data for Natural Resources Mapping (image enhancement, rectifications )

True simultaneous ICP-OES for unmatched speed and performance

Superior ICP-OES optical design for unmatched speed and performance

New fraction collection features with the Agilent 220 micro plate sampler and micro plate sampling software rev. A.03. Technical Note.

DESIGN AND OPERATION OF A WIDE RANGE SEGMENTED GAMMA RAY SCANNING ASSAY INSTRUMENT FOR THE MEASUREMENT OF BOTH LOW AND INTERMEDIATE LEVEL WASTE

Determination of the N-Nitrosamine Content in Rubber Articles Using the Agilent 7000A Triple Quadrupole GC/MS System

Prodigy DC Arc. The Ultimate Solution for Elemental Analysis of Solid Samples

Chem466 Lecture Notes. Spring, 2004

Application note: A10-011A The Effect of Filter Selection on the LOD in the Fluorometric Determination of Histamine in Seafood

RFID Systems: Radio Architecture

30 Plex Human Luminex (Invitrogen Kit, Single Plate)

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

QUANTOF. High-resolution, accurate mass, quantitative time-of-flight MS technology

Long Range Acoustic Classification

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

The FTNIR Myths... Misinformation or Truth

Thermo Scientific SPECTRONIC 200 Education

Understanding Mixers Terms Defined, and Measuring Performance

Sodium Thiosulphate and hydrochloric acid

CHARACTERISTICS OF REMOTELY SENSED IMAGERY. Radiometric Resolution

contraa Hit the Mark! High-Resolution Continuum Source AAS

X-Supreme8000. A powerful innovative XRF analytical solution combining performance with flexibility

Ultrasensitive LC MS/MS: Agilent 6470 and 6495 LC-QQQ

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect. teaching instrument

Advancing EDS Analysis in the SEM Quantitative XRF. International Microscopy Congress, September 5 th, Outline

Technical Specifications for the procurement of Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Polymer Comparisons for the Storage and Trace Metal Analysis of Ultrapure Water with the Agilent 7500cs ICP-MS Application

Wide-Band Imaging. Outline : CASS Radio Astronomy School Sept 2012 Narrabri, NSW, Australia. - What is wideband imaging?

Approaches to highest sensitivity analysis of selected Dioxin / Furan congeners:

Receiver Performance and Comparison of Incoherent (bolometer) and Coherent (receiver) detection

LC/MS/MS. Page Header. triple quadrupole mass spectrometer.

Test Report. Report No.: A001R Date: Dec.08,2016 Page 1 of 13. Applicant: Address: Report on the submitted sample(s) said to be:

Ozone Absorption Cross Sections Laboratory Measurements

WIDE ANGLE GEOMETRY EDXRF SPECTROMETERS WITH SECONDARY TARGET AND DIRECT EXCITATION MODES

Walk Input Method. DesignShop V9 Basic Digitizing Quick Reference Guide

Durham Model Aquifer- Pumping test March 23, 2018

Fully Demountable Torch Installation Instructions (Axial Version)

High collection efficiency MCPs for photon counting detectors

Digital Image Processing. Lecture # 6 Corner Detection & Color Processing

Application of optical measurement techniques for experimental modal analyses of lightweight structures

file://c:\all_me\prive\projects\buizentester\internet\utracer3\utracer3_pag5.html

Keysight Technologies Using a Wide-band Tunable Laser for Optical Filter Measurements

S1 TITAN Alloy LE Calibrations (P/N: )

The Multivariate Optical Element Platform. Technology Overview

Processing of MA(or µ)-xrf Data with the M6 software

Thermo Scientific SPECTRONIC 200

ELEC E7210: Communication Theory. Lecture 11: MIMO Systems and Space-time Communications

CRL MASS SPECTROMETRY FACILITY INSTRUMENT USER MANUAL MALDI MICRO. Operating Instructions. Basement Spec Lab:

User s Guide. Windows Lucis Pro Plug-in for Photoshop and Photoshop Elements

The Zeiss AiryScan System, Confocal Four.

Submillimeter (continued)

SUSIM UARS Calibration and Measurements of Solar UV Spectral Irradiance Variation ( )

Webinar Organizers. Ryan Shea. Don Miller. Joe Ryan. Support Specialist. Applications Specialist. Product Manager. Precision Digital Corporation

KNOW TRAINING MORE WITH. PerkinElmer Training Catalogue 2013 Relevant, interactive, rich in content.

Ray Detection Digital Image Quality and Influential Factors

TESTING FLAT-PANEL IMAGING SYSTEMS: What the Medical Physicist Needs to Know. JAMES A. TOMLINSON, M.S., D.A.B.R. Diagnostic Radiological Physicist

Optimized Semi-Flexible Matrix Array Probes for Large Rotor Shafts and DGS Sizing Diagram Simulation Tool

What is a WQSensor? Software Installation. Uninstalling WQSensors Software. NexSens Technology, Inc. TABLE OF CONTENTS

Introducing the Agilent 7000A Triple Quadrupole GC/MS

Physics 4C Chabot College Scott Hildreth

Very Long Baseline Interferometry

12 Projectile Motion 12 - Page 1 of 9. Projectile Motion

Pixel Response Effects on CCD Camera Gain Calibration

Software for Electron and Ion Beam Column Design. An integrated workplace for simulating and optimizing electron and ion beam columns

Optimizing Instruments for Modern HPLC Columns

Noise Analysis of AHR Spectrometer Author: Andrew Xiang

The SS6000 Gold Mate Series For analyzing all precious metals and other elements from Mg to U

Target Temperature Effect on Eddy-Current Displacement Sensing

Fast Raman Spectral Imaging Using Chirped Femtosecond Lasers

Qualitative analysis tutorial for Tracer III SD and V+ data

Introduction of a Single Chip TLD System for Patient Dosimetry

Abstract No. 32. Arne Bengtson and Tania Irebo. Swerea KIMAB AB, Isafjordsgatan 28A, SE Kista, Sweden

FLASH LiDAR KEY BENEFITS

Residual Gas Analyzers

Name: Lab Partner: Section:

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

Surface Analysis of one Pound from the Egyptian Coins

Compliance Engineering Ireland Ltd RAYSTOWN, RATOATH ROAD, ASHBOURNE, CO. MEATH, IRELAND Tel: Fax:

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

TCXO Application vs. OCXO Application Dave Kenny

brief history of photography foveon X3 imager technology description

Zone. ystem. Handbook. Part 2 The Zone System in Practice. by Jeff Curto

CHEMOMETRICS IN SPECTROSCOPY Part 27: Linearity in Calibration

RECOMMENDATION ITU-R SM Method for measurements of radio noise

OPTICS AND LASER PHYSICS LABORATORY #10 INSIDE A LASER CAVITY -- EXPLORING STABILITY, POLARIZATION, AND MODES with Mark Chawla and Chris Baird

CHEM*3440 Instrumental Analysis Mid-Term Examination Fall Duration: 2 hours

Callidus quickstart. Introduction. Program Download and installation

Southern African Large Telescope. RSS CCD Geometry

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect tool. for routine measurements

Red/Far-Red Sensor SKR 110. Skye Instruments Ltd., 21 Ddole Enterprise Park, Llandrindod Wells, Powys LD1 6DF UK Tel: +44 (0)

A New Noise Parameter Measurement Method Results in More than 100x Speed Improvement and Enhanced Measurement Accuracy

Transcription:

Finer Points of ICP-OES Setup and Operation (Part 1) James Bartos Office of Indiana State Chemist

Challenges with Fertilizers Broad conc ranges from low ppm to upper % level Want to test all nutrient elements at the same time in a single extract Avoid multiple methods Avoid multiple dilutions Easily ionized and difficultly ionized elements in the same digest/extraction solutions Range of matrices from simple water or dilute acids to difficult organic solvents and high salts Investigational allowances (IA s) were created with method(s) optimized for a single analyte ICP is simultaneous, so conditions aren t necessarily optimized for each element

Challenges with Instruments Operation is now completely computer controlled Good: almost anyone can operate Bad: mostly just pointing and clicking; what's going on in background may not be fully understood or watched? e.g. are you looking at intensities or just concentrations? Often configured for robust middle-of-the-road analysis, but one-size-fits-all results in compromises MANY different instrument options, but most have some limitations

Concentration range Wavelength selection Calibration Select Topics Multiple wavelengths per range Line Splitting Rationale General principles Your ICP may have slightly different properties

Calibration Options 1. Single Wavelength per element Easier and less confusing Data/LIMS processing advantages (i.e. one result/element) Can still get good data May not optimize MDL s Can require more secondary dilutions 2. Multiple Wavelengths per element More targeted approach Strong lines for low conc and weaker lines for expanded range Potential for better data (not compromising) Offers confirmation of result More comprehensive use of advanced ICP features Requires more standards as multiple points per curve Potentially large/confusing data output file

Concentration Range Selection Example Fe Similar approach for B, Ca, Cu, Mn, P, K, S, Zn, etc. Limitations for some elements (e.g. As, Pb, Se) Goal: measure from low ppm up to % levels 0.02% = 1 ppm in solution (@ 0.5 g to 100 ml) 20% = 1,000 ppm in solution (@ 0.5 g to 100 ml) Ask vendor 1 to 1,000 ppm? no problem May not mean one wavelength or single calibration Are you willing to do dilutions? How many? How often? Do the samples need to be more concentrated for SUIP or heavy metals analyses?

Wavelength Selection Note: may have fewer wavelength selections with some ICP s

Strategically Select Wavelengths Most intense/sensitive wavelength(s) (e.g. 238.204), may have best MDL, but also narrowest working range Weaker lines will allow for expanded working range, but at the expense of MDL Watch for spectral interference

Basic Considerations Wavelength selection table values are a relative intensity estimate (e.g.1 ppm solution), but that is dependent upon system configuration Rule-of-thumb decent linearity generally up to about 1 million counts Fe wavelength 238.204 = 41,000 counts, so may be linear to about 25 ppm (i.e. 41,000 * 25 ~ 1M) Instrument and detector dependent Data from Agilent 5100 and 720 ICP-OES Suggest making a standard (e.g. 10 ppm), select wavelengths of interest, then start screening

Fe 10 ppm scans 238 Axial is strongest (500K); lowest detection likely; minimal spectral interference; ~ linear to 20 ppm 259 Axial is next strongest line (125K), use to confirm 238?, ~ linear to 80 ppm 238 Radial is ~ 1/10 th the signal of axial view; consider starting calibration at 20 or 80 ppm; ~ linear to 200 ppm 259 Radial is ~ 1/8 th the signal of axial view; consider starting calibration at 80 ppm; ~ linear to 600 ppm

Fe 10 ppm scans 260 Axial ~ 14K net counts; linear to about 700 ppm; could go to 1,000 ppm with quadratic 261 Radial ~ 7K net counts; linear to about 1,400 ppm Strategy: 0 to 20 ppm with Fe 238 Axial 0 to 80 ppm with Fe 259 Axial 20 to 200 ppm Fe with 238 Radial 80 to 600 ppm Fe with 259 Radial 600 to 1,000 ppm Fe with 260 Axial (quadratic) 600 to 1,000 ppm (+) Fe with 261 Radial Evaluate other possibilities

Example of How to Implement: Set Min and Max conc for each wavelength Note: Values are in % with some extrapolation Have to set up a Mean or average column Mean will average appropriate results and can serve as the single result processed by LIMS

Additional Options to Alter Range Pump tube configuration sample vs. internal standard flow rates create a dilution effect Introduction systems and nebulizer type Quadratic curve fit (be careful) Others?

Concerns with Broad Calibration Range? Higher points on curve have disproportionate influence Not just relative value, but the squared term Mainly concern about linear curve fit as quadratic has curvature Misleading: correlation coefficient may look good, but lower concentrations could be compromised Quadratic curve fit may help some Can get better low-level data if split up broad calibration range into segments 1. Can use multiple line approach previously described 2. Can even do this with the same wavelength Select twice and rename

Concern with Point Distribution Serial dilutions can create some problems 10 fold dilutions: 500 ppm, 50, 5, 0.5, 0 Easy, quick and meets 5 points per curve criteria Intense signal linear? Great R 2 = 0.99999 Essentially drawing a straight line from 50 to 500 as lower points have minimal impact on curve

Reality? More points with more even distribution can indicate curvature In this case, selected concentration range is too broad or select different curve fit

Apply Quadratic

Concerns with Dynamic Range Demonstrate that higher points on calibration have disproportionate influence Can apply greater weighting to lower standards, but using what criteria? May not be allowed? 0 to 400 ppm curve Bottom 3 stds (i.e. 3, 5 & 10 ppm) deliberately diluted by 50% Still decent R 2 = 0.9998

Alter Top Standard What happens if alter just top standard by 10%? Can more easily see the curve is bad R 2 = 0.998 What s the point? Higher standards primarily influence the curve and therefore may not best represent the lower calibration range Small errors in the higher standards can negatively impact the accuracy of the lower concentrations

Recommendation? Line splitting Example 0 to 800 ppm using same wavelength Select same wavelength three times Rename: 1. LO Ca183, 2. MID Ca183 3. HI Ca183 (example)

Mid Ca183 Lo Ca183 Good low recoveries, may be even better if use narrower curve

Some Topics for Future? Different introduction systems Exposure length and number Pump tube selection and condition Matrix matching e.g. what about cumulative matrices from stock standards Dilutions - do you compensate for matrix contribution from sample? Internal standards and selection Spectral deconvolution Uptake and rinse times Others??

Summary ICP-OES instruments are well suited for fertilizer analysis, with only limited exceptions Multiple options to cover a broad dynamic concentration range and get both low detection capability and minimize the need for dilutions Requires using ICP features at a higher level Instrument software manages most of this Can always try different options and run in the background Compare results from different configurations Don t need to include result in your mean until validated Doesn t take any extra analysis time Can result in improvement in data quality