METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

Similar documents
METRISO G1000+ High-Precision Insulation, Low Resistance and Voltage Measurement Instrument

METRISO G1000+ Insulation resistance. and Voltage Measurement Instrument. Application

PROFiTEST C Test Instrument per DIN VDE /8.14

METRATESTER 5+ Tester for DIN VDE /6.15

PROFiTEST C Test Instrument per DIN VDE /11.10

METRAClip87 and 88 Clamp Multimeters

METRAClip85 and 86 Clamp Multimeters

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2.

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:

METRAHIT WORLD. International TRMS Multimeter /2.16. Features

METRAHIT T-COM Cable Multimeter for Measurements in Symmetrical Copper Cable Networks

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

METRISO G500/G1000 and METRISO G500MM

METRISO INTRO, BASE, TECH Insulation, Low Resistance and Voltage Measurement Instrument

METRISO 5000 D-PI Digital High-Voltage Insulation Tester

METRAHIT ISO TRMS Multimeter with Insulation Measurement /2.13

METRAHIT ISO TRMS Multimeter with Insulation Measurement

Operating Instructions METRA HIT 1A/2A /1.10. Analog Multimeter

METRISO 5000 A/AK. High-Voltage Insulation Tester With Battery or Crank Generator Operating Mode. Option Z580A Crank Generator. Operating Instructions

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

METRAHIT 27M and METRAHIT 27I Milliohm Resistance Meter and Digital Multimeter, Insulation Tester and Data Logger

GOSSEN METRAWATT. Testers

METRAHIT X-TRA PRO BASE TRMS Digital Multimeters

Data Sheet. RISH Max-14 Analog-Digital Multimeter. RISH Max-14 Analog-Digital Multimeter. Page 1 of 5. Rishabh Instruments 1 / 05 / IX / 1210 / B

METRISO 5000 D-PI Digital High-Voltage Insulation Tester

METRAHIT ULTRA High Resolution TRMS System Multimeter

METRAHIT X-TRA OUTDOOR TECH PRO. TRMS Digital Multimeters. Applications. Features

MAVOWATT 4 Multifunction Power Meter

METRAHIT EXTRA ETECH ESPECIAL EBASE TRMS Digital Multimeters

METRISO B530 High Ohmic Resistance Tester for resistance to ground & surface resistance measurements

Operating Instructions. METRAport 3A /6.09. Analog Multimeter

METRAHIT ULTRA High Resolution TRMS System Multimeter

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

METRAHIT EXTRA ETECH ESPECIAL EBASE TRMS Digital Multimeters

GAMMA 20 DIGITAL MULTIMETER

RISH Max-12 and 14 Analog-Digital Multimeter. Data Sheet. RISH Max-12 and 14 Analog-Digital Multimeter. Rishabh Instruments

3B SCIENTIFIC PHYSICS

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Warning, refer to accompanying documents V CAT II Overvoltage category II device. CSA Canadian Standards Association

QUICK SETUP GUIDE SECULIFE HITAM

POINTAX 6000L2 Point Recorder

METRA HIT 27M and 27I Milliohm Resistance Meter and Digital Multimeter, Insulation Tester and Data Logger

METRAHIT WORLD International TRMS Multimeter

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Installation Tester BENNING IT 115. Operating Manual

PROFiTEST 0100S-II Test Instrument for DIN VDE 0100

METRAHIT EXTRA ETECH ESPECIAL EBASE TRMS Digital Multimeters

METRA HIT 22 26S/M Analog-Digital Multimeters with Signal Generator

METRA HIT 28C Calibrator, Multimeter and Milliohmmeter

Fluke and

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

METRA 28C Calibrator, Multimeter and Milliohmmeter

METRA 22 26S/M Analog-Digital Multimeters with Signal Generator

LINAX 4000L Continuous-line recorder

Fluke 1623 and GEO Earth Ground Testers. Technical Data. Stakeless testing

Power supply CP-E 24/2.5

PROFITEST. Testing of Safety Measures MASTER TESTER INSTALLATION

Installation Tester BENNING IT 130. Operating Manual

QUICK SETUP GUIDE SECULIFE IP

Data Sheet. Analog - Digital Multimeter. RISH Multi RISH Multi Analog-Digital Multimeter. Page 1 of 6. Rishabh Instruments

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1507/1503. Insulation Testers. Technical Data. Features and benefits:

Operating Instructions METRA HIT 16I/L/T. Analog Digital Multimeter with Insulation Measurement /5.06

Power supply CP-E 24/20.0

1587/1577 Insulation Multimeters

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Testboy TV 416/432(A) CEE adapter*

METRAHIT MULTICAL Multimeter, Calibrator

PROFITEST 0100S-II+ Tester DIN VDE 0100

Operating Instructions. METRAport 40S /1.13. Digital Multimeter

Technical Data Sheet. Zeta 20

INSULATION TESTER SERIES

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Power supply CP-E 24/0.75

Earth 2/3 MI 2126 Instruction Manual Version 1.0, Code No

Installation / Monitoring Technique

METRAHIT 28C Calibrator, Multimeter and Milliohmmeter

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 24/2.5

METRAHit 30M Precision Digital Multimeter

SECULIFE HIT METRAHIT X-TRA OUTDOOR TECH PRO BASE TRMS Digital Multimeter

Technical Datasheet. Delta Power 1000A / 400A AC-DC

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Operating Instructions CAMILLE BAUER METRAWATT METRAOHM /9.97. Low impedance resistance meas. instrument

QUINT-PS AC/24DC/40

Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Power supply CP-T 24/20.0 Primary switch mode power supply

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

CP-T range Benefits and advantages

Power supply CP-D 12/2.1

CP-T range Product group picture

SUBJECT TO CHANGE WITHOUT NOTICE

Power supply CP-D 24/1.3

Measure voltage without test leads. Product Highlights

MS2030 CAT III 600 V A V AUTO RS232

Transcription:

3-349-813-3 1/9.14 Insulation measurement per EN 61557-2/VDE 413, part 2 Test voltages: 5 V, 1 V, 25 V, 5 V and 1 V Analog display of measured values and limit values Intelligent filter precise and measurement-dependent activation for the measurement of very high resistances Indication of dangerous touch voltage by means of LED Indication of limit value violations by means of LED Detection of interference voltage in switch position OFF Surge protection: protects the instrument in the event of inadvertent connection to mains power Fuse link for all resistance measuring ranges Electronic fuse for the protection of low resistance and resistance measurement Voltage measurement to 1 V Low-resistance measurement per EN 61557-4/VDE 413, part 4 Guard terminal for compensating surface current Compact and rugged: for service calls under harsh conditions One measuring point self-test with test resistance of 1 M per IEC/HD 6364-6 / EN 511 Applications The insulation and resistance measuring instrument allows for quick and efficient testing of protective measures in accordance with DIN VDE 1, ÖVE-EN 1 (Austria), NIV/NIN SEV 1 (Switzerland), and regulations specific to other countries as well. The instrument complies with IEC/EN 61557 / VDE 413 regulations: Part 1: General requirements Part 2: Part 4: Insulation resistance Resistance of earth connection, protective conductors and equipotential bonding Part 1: Electrical safety in low-voltage systems up to 1 V AC and 15 V DC Equipment for testing, measuring or monitoring of protective measures As well as requirements per VDE 71-72: Repair, modification and testing of electrical devices, The insulation measuring instrument is suitable for the following tasks: Measurement of insulation resistance at voltage-free devices and systems, up to 1 V depending upon variant Checking of test objects for absence of voltage in systems with up to 1 kv Testing of the resistance of earthing conductors, protective conductors and equipotential bonding Testing of electrostatic discharge capacity for floor coverings (using shielded measurement cables) EN 181 Intelligent filter Precise and measurement-dependent activation for the measurement of very high resistances with beating, i. e. compensation of 16 2 / 3 Hz and 5 Hz interference attenuation of capacitive influences from power cables, etc. suppression of electric field influences Overview of Included Features METRISO PRO Article number M55R Measurements R INS U = 5, 1, 25, 5, 1 V 3 R LO.17... 4 3 U 1... 1 V 3 Display Functions Scale illumination 3 Limit value LED (green/red) for: additional acoustic signal, R INS R LO limit values per VDE 1 LED for dangerous contact voltage in the off state and for active test voltage 3 Battery level display 3 Special Functions Discharge capacitive devices under test 3 Safety shutdown (UBatt < 8 V) 3 Features Measuring category CAT II 1 V / CAT III 6 V / CAT IV 3 V 3 Test resistor: 1 M 3 Factory calibration certificate 3 Discharging Capacitive Devices Under Test Capacitive devices under test such as cables and coils, which may be charged with test voltage, are discharged by the measuring instrument. The falling voltage value can be observed at the display. GMC-I Messtechnik GmbH

Characteristic Values Meas. Qty. Scale / Standard R INS VDE 413 Measuring Range 1 k... 1 M 1 k... 1 T Nominal range of use 1 k... 1 M 1 k... 1 G Nominal / Open- Circuit Voltage 5 V /1 V: 1.25 U ISO 25 V /5 V / 1 V: 1.1 U ISO Nominal Current I N Short- Circuit Current I K 1 ma 5 ma Intrinsic Uncertainty under Reference Conditions 2 2.5% 2.5% 1 R LO 3 to 5.17 to 4 4 4 V < U < 6 V Test current I N 2 ma 2.5% U AC/DC 2 1 4 Measuring Uncertainty 3 3% of the measured value 1% 5 of the measured value... 1 V 1... 1 V 2.5% U BAT 5 8... 12 V 8.5... 12 V Overload Capacity 1 V AC/DC TRMS 1 V AC/DC TRMS 1 V AC/DC TRMS 1 Accuracy specified here is only achieved with the following optional accessory: shielded high-resistance measurement cable KS-C (article number Z541F). 2 Relative to scale length: Scale 1: 83.13 mm Scale 2: 75.5 mm Scales 3 and 4: 67.2 mm 3 Within the identified range on the respective scale (nominal range of use) 4 with ZERO balancing 5.17... 2 2% 5 1 2 3 4 Reference Conditions Reference temperature + 23 C 3 K Relative atmospheric humidity 4... 75% Measured quantity frequency 45 Hz... 65 Hz Measured quantity waveform Sine, deviation between TRMS and rectified value < 1% Battery voltage 9.5 V.1 V Test resistance 1 M 1% Normal position of use 3 Power Supply Displays Analog Display Measuring movement Scale length Limit LED! LED Moving-coil mechanism with core magnet 83.13 mm (longest scale) LED lights up red to indicate an exceeded limit value LED lights up green to indicate adherence to the limit value LED lights up red to indicate the presence of interference voltage (when instrument is switched off), test voltage during insulation measurement or residual voltage after insulation testing (U > 5 V), Batteries Nominal range of use Battery test Battery saver circuit Service life Safety shutdown 8 ea. 1.5 V mignon cell (8 ea. size AA) (alkaline manganese per IEC LR14) or 8 rechargeable NiMH batteries (must be recharged externally) 8.5... 12 V Battery capacity display via the Bat. TEST key Standby function For R INS (1 V / 1 M ) and R LO with 2 s on-time and 1 measurement each for a duration of 5 s With batteries (alkaline manganese): 9 measurements With rechargeable batteries (2 mah): 85 measurements If supply voltage is too low, the instrument is switched off, or cannot be switched on. When the rotary switch is set to the OFF position, the instrument is completely disconnected from the batteries (after approximately 1 seconds). 2 GMC-I Messtechnik GmbH

Electrical Safety Standard VDE regulation VDE 411, part 1, 1994-3 Protection class II Pollution degree 2 Measuring category CAT II 1 V / CAT III 6 V / CAT IV 3 Fuses Fuse link FF315mA/1V, effective in all resistance measuring ranges, 1 additional replacement fuse in the battery compartment Electronic fuse protects low-resistance measurement R LO Voltage at Device Under Test During Insulation Resistance Measurement Measuring voltage U x at the device under test depending upon its resistance R x at nominal voltage U N = 5 V, 1 V, 25 V, 5 V and 1 V: 1 8 6 4 2 1 U N = 1 V R x /k Electromagnetic Compatibility (EMC) Interference emission EN 61326-1:26 class B Interference immunity EN 61326-1:26 25 2 U N = 25 V 15 1 Ambient Conditions Accuracy temp. range Operating temperature Storage temp. range Relative humidity Elevation Calibration interval... +4 C 1... +5 C 25... +7 C (without batteries) Up to 75% (max. 85% during storage/ transport), no condensation allowed Max. 2 m 1 year (recommended) 5 5 4 3 25 R x /k U N = 5 V 2 Mechanical Design 1 5 R x /k Dimensions Weight Protection 225 x 13 x 14 mm Approx. 1.5 kg with batteries Housing: IP 52, measurement cables and connectors: IP 4 per DIN VDE 47, part 1 / EN 6529, housing category 2 1 8 6 4 U N = 1 V Excerpt from Table on the Meaning of IP Codes IP XY Protection Against IP XY Protection Against (1 st digit X) Foreign Object Entry (2 nd digit Y) Penetration by Water 2 12.5 mm dia. 2 Dripping (at 15 angle) 3 2.5 mm dia. 3 Spraying water 4 1. mm dia. 4 Splashing water 5 Dust protected 5 Jet-water 6 Dust-proof 6 Powerful water jets 2 1 R x /M GMC-I Messtechnik GmbH 3

Applicable Regulations and Standards Scope of Delivery IEC 611-1/ EN 611-1 VDE 411-1 IEC 61557/ EN 61557/ VDE 413 EN 181 EN 6529 VDE 47-1 DIN EN 61326-1 VDE 843-2-1 Safety requirements for electrical equipment for measurement, control and laboratory use Part 1: General requirements (IEC 611-1:21 + Cor. :211); German version of EN 611-1:21 Part 31: Safety requirements for hand-held probe assemblies for electrical measurement and test (IEC 611-31:22 + A1:28); German version of EN 611-31:22 + A1:28 Part 1: General requirements (IEC 61557-1:27); German version of EN 61557-1:27 Part 2: Insulation resistance (IEC 61557-2:27); German version of EN 61557-2:27 Part 4: Resistance of earth connection and equipotential bonding (IEC 61557-4:27); German version of EN 61557-4:27 Part 1: Electrical safety in low voltage distribution systems up to 1 V AC and 15 V DC Equipment for testing, measuring or monitoring of protective measures (IEC 61557-1:2); German version of EN 61557-1:21 Testing of electrostatic discharge capacity for floor coverings in potentially explosive atmospheres Test instruments and test procedures Degrees of protection provided by enclosures (IP code) Electrical equipment for measurement, control and laboratory use EMC requirements Part 1: General requirements 1 Insulation and resistance measuring instrument 1 Factory calibration certificate 1 Set of batteries 1 Carrying strap 1 Alligator clip 1 KS17-4 cable set 1 Condensed operating instructions 1 Supplement Safety Information Detailed operating instructions for download from our website at www.gossenmetrawatt.com 4 GMC-I Messtechnik GmbH

Accessories (not included) ISO Calibrator 1 Calibration adapter for rapid, efficient testing of the accuracy of measuring instruments for insulation resistance and lowvalue resistors TR25 Reel KS-C Cable Set Cable set consisting of measurement cable and high-resistance measurement cable for measurements in the G range KS24 Cable Set The KS24 cable set includes a 4 m long extension cable with a permanently attached test probe at one end and a contact protected socket at the other end, as well as an alligator clip which can be plugged onto the test probe. TR5 Drum with 5m Measurement Cable 5 m measurement cable coiled onto a plastic drum. Connection to the inside end of the cable is made possible with a socket integrated into the drum. The other end is equipped with a banana plug. The drum axle with handle can be removed for space saving storage. Cable resistance can be compensated for with the rotary selector switch in the R LO position. Z55A Test Probe for Remote Triggering Connection example: module slot for INTRO / BASE / TECH / PRO / XTRA Telearm 1 Floor Probe The 181 floor probe makes it possible to measure the resistance of insulating floors in accordance with DIN VDE 1, part 61, and EN 181. Measurement Key Key for Measuring Point Illumination Test Probe Safety Collar Measuring Point Illumination Safety Cap GMC-I Messtechnik GmbH 5

Magnetic Test Probes (patented) with Magnetic Strain Relief (Z52U) Order Information Description Type Article number Insulation measuring instrument for DIN VDE 1, ÖVE-EN 1 (Austria), NIV/NIN SEV 1 (Switzerland), complies with IEC/EN 61 557/VDE 413, parts 1, 2, 4 and 1 Test voltages to 1 V, voltage measurement to 1 V, low-resistance measurement METRISO PRO M55R METRISO PRO with test probe for remote triggering (Z55A) and everready case (Z55C) METRISO PRO-Set M551R Magnetic Strain Relief Z55C Ever-Ready Case Moving touch protection reliably covers the magnetic contact pin by means of spring force. Accessories (not included) Calibration adapter for testing the accuracy of instruments used for measuring insulation resistance and low-resistance for test voltages of up to 1 V (per VDE 413, parts 1, 2 and 4). ISO calibrator 1 M662A Cable set consisting of measurement cable and high-resistance measurement cable for measurements in the G range KS-C Z541F Cable set consisting of a 4 m long extension cable with a permanently attached test probe at one end and a contact protected socket at the other end, and 2 alligator clips which can be plugged onto the test probe KS24 GTZ321R1 Triangular probe for floor measurements per EN 181, DIN VDE 1 181 probe GTZ3196R1 Test probe with START/STOP key and an additional key for illuminating the measuring point, including shielded connector cable and test probe holder for the carrying strap Test probe for remote triggering METRISO Z55A Telescoping rod for PE measurement Telearm 1 GTZ3232R1 Reel with 25 m measurement cable TR25 Reel GTZ333R1 Drum with 5 m measurement cable TR5 drum GTY1414E34 Magnetic test probes with touch protection set including magnetic holder Contact diameter: 5.5 mm, insulated, CAT III 1 V / 4 A, temperatures from -1 to 6 C, holding power under standard conditions with flat head screws: 12 g perpendicular to the contact surface; instrument connection: angled multilam plug for instruments from the METRISO INTRO / BASE / TECH / Set 1 magnetic test PRO / XTRA series probes Ever-ready case for METRISO INTRO / BASE / TECH / PRO / XTRA with external pocket for measurement cable METRISO ever-ready case Z52U Z55C For additional information regarding accessories please refer to: www.gossenmetrawatt.com Edited in Germany Subject to change without notice PDF version available on the Internet GMC-I Messtechnik GmbH Südwestpark 15 9449 Nürnberg Germany Phone: +49 911 862-111 Fax: +49 911 862-777 E-mail: info@gossenmetrawatt.com www.gossenmetrawatt.com