ISOMETER IRDH575. Approvals

Similar documents
isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

The Power in Electrical Safety

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

ISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet

ISOMETER iso685- Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

Measuring current transformers of the W, W series

ISOMETER iso685-d-p. Device features

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Measuring current transformers of the W AB(P) series

RCMS460 and RCMS490 Series

ISOMETER IR Headline. Version V004. Vorläufiges Datenblatt

Power Quality and Energy Measurement PEM533

ISOMETER Headline IR /IR

Measuring current transformers of the W B series

Power Quality and Energy Measurement PEM575

PEM353. Universal measuring device

Technical data Insulation fault location system Device components

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Insulating fault locator to locate insulation faults in ungrounded DC, AC and three-phase power supplies (IT systems)

Power Quality and Energy Measurement PEM735

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Installation / Monitoring Technique

DEIF A/S. Insulation monitor. Type SIM-Q

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/020

CM-IWM.11 Insulation monitoring relay

A-ISOMETER IR / IR

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

27/04/2015

Power Quality and Energy Measurement PEM575

Insulation Guard IW 1000 Monitoring of ungrounded AC- and DC voltage systems up to 690V

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Product overview Insulation monitoring devices A-ISOMETER Insulation fault location systems EDS

Installation- / Monitoring Technique

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

Electronic Circuit Breaker with reset input ESS20-1..

Power Quality and Energy Measurement PEM330/PEM333

SINEAX B 811 Power Pack with additional Functions


BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Type Nominal voltage (V) Code HSV V

Electronic Circuit Breaker ESS20-0..

Transformers, Power Supply Units and Socket Outlets

Electronic Circuit Protector ESX10-T

Thermistor motor protection relays

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

The Power in. Electrical Safety. Product presentation isohr685w-d/s-i-b. Updated: BENDER > isohr685 Mumtaz Farooqi

02/11/2015

PHOENIX CONTACT - 09/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

Installation- / Monitoring technique

Operating Instruction

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Protection components

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Datasheet. Electronic Circuit Protection ESX10-T

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

XUA1 - AC Voltage and phase balance relay

Datasheet - PROTECT-IE-02

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

PCB relay for DC voltage, polarized, monostable or bistable

Protection components

E-STOP relays, safety gate monitors

Subject to changes 11/2003 Page 1/7

Thermistor motor protection relays

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

PSR-SCP- 24DC/ESD/5X1/1X2/300

Trip amplifier, 1 channel

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Solid-state Timer H3DS

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Temperature Input Module for Zone 1 Series 9482/32

DIGEM f 96 x 48 EK. Applications. Description

Product overview. ISOMETER Insulation monitoring devices ISOSCAN Insulation fault location systems EDS

Electronic Circuit Breaker ESS1 for System SVS1

Transcription:

Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018

Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems Product description The ISOMETER of the IRDH575 series monitors the insulation resistance of unearthed power supplies (IT systems). It is suitable for universal use in (N)AC, AC/DC and DC systems. AC systems may include extensive DC-supplied loads, such as converters or thyristor-controlled DC drives. The IRDH575 in combination with EDS4 series insulation fault locators and the appropriate measuring current transformers is designed to set up the respective equipment for insulation fault location. ISOMETER IRDH575 Device features Universal application in (N)AC, AC/DC and DC IT systems 20 575 V/40 760 V Response range 1 kω 10 MΩ Info button for the indication of various parameters and the system leakage capacitance Comprehensive self-monitoring function including system fault alarm relay Internal/external test and reset button Two separate alarm relays, N/C or N/O operation selectable Backlit plain text display 4 x 16 characters RS-485 interface Data memory, disconnection from supply and 0/4 20 ma current output Can be extended to an insulation fault location system for max.1080 circuits Adjustable locating current for insulation fault location Appropriate for EDS4 insulation fault location systems AMP measurement method Approvals Function insulation monitoring When the insulation resistance between the system conductors and earth falls below the set response value, the alarm relays switch and the alarm LEDs light up. Two separately adjustable alarm relays (N/C or N/O operation) allow a distinction to be made between prewarning and alarm. The measured value is indicated on the LC display or an externally connectable measuring instrument. In this way any changes, for example when circuits are connected to the system, can be recognised easily. The fault message can be stored. The fault memory can be reset by pressing the internal or external reset button. By pressing the test button, the function of the device as well as the connections to system and earth can be tested. Pressing the Info key provides additional information, such as the existing system leakage capacitance or device settings. Function insulation fault location Insulation fault location is carried out with EDS4 series insulation fault locators and the respective measuring current transformers. When the IRDH575 detects an insulation fault, the insulation fault location process is started automatically or manually. The IRDH575 generates a locating current the amplitude of which is dependent on the existing system voltage and the insulation fault. When low-resistance insulation faults occur, the locating current is limited by the IRDH575. This limit value can be set via an appropriate menu. The locating current pulse flows from the IRDH575 via the live parts, taking the shortest path to the location of the insulation fault. From there, it flows via the insulation fault and the PE back to the IRDH575. This locating current pulse is then detected by the measuring current transformers located in the insulation fault path, and is evaluated by the EDS insulation fault locators. When the locating current in the measuring current transformer exceeds the response value, the associated alarm LED at the EDS47 lights up indicating the faulty subcircuit. This information is also indicated on the LC display of the IRDH575. By assigning the measuring current transformers to the respective circuit, the point of fault can easily be detected. Additional functions 99 alarm messages with date and time can be stored in the data memory of the IRDH575. The device also includes Isometer disconnecting relays when several ISOMETER s are operated in (coupled) IT systems. An integrated RS-485 interface (BMS protocol) allows information exchange with other Bender devices. Via the 0/4-20mA interface details about the insulation resistance can be transferred to higher-level control systems. The function of the IRDH575 is continuously monitored. When a system fault occurs, the associated alarm LED lights up and the respective alarm relay switches. System design Basically, an EDS system consists of an IRDH575 and one or several EDS4 insulation fault locators with the associated measuring current transformers. Information exchange between the EDS4 and the IRDH575 takes place via a time and cost-saving RS-485 interface. Such a system may include up to 90 EDS4 so that a total of 1080 circuits can be monitored. Standards The ISOMETER of the IRDH575 series complies with the requirements of the device standards: DIN EN 61557-8 (VDE 041-8), EN 61557-8, IEC 61557-8, IEC 6126-2-4, DIN EN 60664-1 (VDE 0110-1), DIN EN 60664-, DIN EN 61557-9, VDE 041-9, IEC 61557-9, ASTM F1669M-96 (2007), ASTM F1207M-96 (2007) 2 IRDH575_D00089_02_D_XXEN/09.2018

Operating elements Wiring diagram (N)AC-System Un AC-System Un DC-System Un 7 8 9 1 11 12 1 2 4 6 7 8 9 5 1 2 4 5 6 10 11 17 16 15 12 1 - INFO button: to query standard information ESC button: back (menu function), confirms parameter changes 2 - TEST button: to call up the self test (Isometer function only) Arrow up button: parameter change, to move up in the menu - RESET button: to delete insulation fault alarms (Isometer function only) Arrow down button: parameter change, to move down in the menu 4 - MENU button: to call up the menu system. Enter button: to confirm parameter changes 5 - EDS LED lights: Insulation fault location has been started 6 - EDS alarm LED lights: Insulation fault localised 7 - Alarm LED 1 lights: insulation fault, first warning level reached 8 - Alarm LED 2 lights: insulation fault, second warning level reached 9 - LED lights: Device error 10 - Indication of the insulation resistance in kω 11 - Additional information about the insulation resistance: + = Fault at L+, - = Fault at L-, s = A new measuring process has been started. 12 - Bus address of the testing EDS46 (indication in case of fault detection) 1 - Channel being monitored by EDS4 (indication in case of fault detection) 14 - Locating current in ma or µa (indication in case of fault detection) 15 - EDS in AUTO mode und just running. Further modes are: on, off, pos: address and channel of the EDS can be predefined (in the Master mode only). 1 cycle: When all the channels have been checked once, the EDS will be deactivated. 16 - Polarity of the locating current. Point = valid BMS traffic, H = a new entry is made in the history memory. 17 - Plain text fault messages 1 14 10 1 - For external indicating instrument Current output 0 20 ma or 4 20 ma *2 - External test button T1, T2 (N/O contact) * - External reset button R1, R2 (N/C contact or wire jumper), (with the terminals open and the ISO-SETUP setting Memory:off, insulation faults will not be stored) *4 - STANDBY, when the contact is closed, no insulation measurement is carried out; disconnection from the IT system being monitored 5 - S1 = ON : Termination of the serial RS-485 interface (A/B) with 120 Ω S2 = not wired 6 - Serial RS-485 interface (BMS bus) 7 - Alarm relay K (device error and EDS alarm) (addr.: 1) 8 - Alarm relay K2 (insulation fault 2); available changeover contacts 9 - Alarm relay K1 (insulation fault 1); available changeover contacts 10 - Supply voltage U S (see nameplate) via 6 A fuse; for UL and CSA applications, it is mandatory to use 5 A fuses. 11 - Connection to the AC system to be monitored: Connect terminals L1, L2 L to conductor L1, L2, L 12 - Connection to the AC system to be monitored: Connect L1 to conductor L1and terminals L2, L to conductor L2 1 - Connection to the DC system to be monitored: Connect L1 to conductor L+ and terminals L2, L to conductor L- 14 - Separate connection of and KE to PE 14 * The terminal pairs 2, and 4 have to be wired electrically isolated and must not be connected to PE! IRDH575_D00089_02_D_XXEN/09.2018

ISOSCAN EDS195P ISOMETER IRDH575 Characteristic curve Max. AC voltage between system and earth in the frequency range < 50 Hz U n [V] Characteristic curve response times t an [sec] R f f n [Hz] C e [µf] Wiring diagram rear view System structure Example 1 2 1 - ISOMETER IRDH575 2 - RS-485/BMS protocol - EDS460/EDS461 4 - EDS090/EDS091 4 4 IRDH575_D00089_02_D_XXEN/09.2018

Typical circuit EDS460 insulation fault location system with IRDH575 1 Typical circuit EDS461 insulation fault location system with IRDH575 1 4 4 U S 2 4 4 U S 2 5 6 5 6 EDS system with IRDH575, EDS460 and measuring current transformers W in a AC system 1 - AC, NAC, DC 20 575 V bzw. AC, NAC, DC 40 760 V 2 - U S see ordering information, 6 A fuse recommended. Note: Supply voltage US in the IT system requires two fuses. - Measuring current transformers W 4 - Outgoing circuits to the loads 5 - ISOMETER IRDH575 6 - Insulation fault locator EDS460 1 - AC 20 265V/DC 20 V 08 V 2 - U S see ordering information, 6 A fuse recommended. Note: Supply voltage US in the IT system requires two fuses. - Measuring current transformers W /8000 4 - Outgoing circuits PLC: inputs and outputs 5 - ISOMETER IRDH575 6 - Insulation fault locator EDS461 Design of an insulation fault location system with EDS461 The example above shows an EDS461 system in a DC system for the supply of a programmable logic controller (PLC). Due to the fact that the inputs of PLC systems are very sensitive, the use of an EDS461 is recommended. The locating current of the IRDH575 is to be set to max. 2.5 ma or as necessary to 1 ma, in order to avoid influences on the PLC system. IRDH575_D00089_02_D_XXEN/09.2018 5

Technical data Insulation coordination acc. to IEC 60664-1 Rated insulation voltage Rated impulse voltage/pollution degree Voltage ranges AC 800 V 8 kv/ IRDH575B1-425: Nominal system voltage Un AC, /(N)AC 20 150 V* Nominal frequency fn 50 460 Hz Nominal system voltage Un DC 20 150 V* IRDH575B1-45: Nominal system voltage Un AC, /(N)AC 20 575 V* Nominal frequency fn 50 460 Hz Nominal system voltage Un DC 20 575 V* IRDH575B2-45: Nominal system voltage Un AC, /(N)AC 40 760 V* Nominal frequency fn 50 460 Hz Nominal system voltage Un DC 40 575 V* IRDH575B1-45: Supply voltage US (also see nameplate) AC 88 264 V* Frequency range US 42 460 Hz Supply voltage US (also see nameplate) DC 77 286 V* IRDH575B1-427: Frequency range US 42 460 Hz Supply voltage US (also see nameplate) DC 19.2 72 V* Power consumption 14 VA Response values Response value Ran1 (Alarm1) 1 kω 10 MΩ Response value Ran2 (Alarm2) 1 kω 10 MΩ Relative uncertainty (20 kω 1 MΩ) (acc. to IEC 61557-8) ±15 % Relative uncertainty (1 20 kω) +2 kω/+20 % Relative uncertainty (1 10 MΩ) 0.2 MΩ/+20 % Measuring time see characteristic curves Hysteresis (1 10 kω) +2 kω Hysteresis (10 kω 10 MΩ) 25 % Measuring circuit for insulation measurement Measuring voltage Um 40 V Measuring voltage Um (IRDH575B1-4227) 10 V Measuring current Im (at RF = 0Ω) 220 μa Internal DC resistance Ri 180 kω Impedance Zi at 50 Hz 180 kω Permissible extraneous DC voltage Ufg (variant B1) DC 810 V Permissible extraneous DC voltage Ufg (variant B2) DC 1060 V System leakage capacitance Ce 500 µf Factory setting Ce 150 μf Measuring circuit for insulation fault location (EDS) Locating current IL DC Test pulse/break 1/2.5/10/25/50 ma 2/4 s Displays Display, illuminated four-line display Characters (number of characters) 4 x 16 Display range measured value 1 kω 10 MΩ Operating uncertainty (20 kω 1 MΩ) (acc. to IEC 61557-8) ±15 %** Operating uncertainty (1 20 kω) ±1 kω/15 %** Operating uncertainty (1 10 MΩ) ±0.1 MΩ/15 %** Outputs/Inputs Test/reset button internal/external Current output for measuring instrument SKMP (scale centre point = 120 kω): Current output IRDH575 (max. load) 0/4 20 ma ( 500 Ω) Accuracy current output (1 kω 1 MΩ) ±10 %, ± 1 kω Serial interface Interface/protocol RS-485/BMS Max. cable length 1200 m Cable (twisted in pairs, one end of shield connected to PE) recommended: J-Y(St)Y min. 2 x 0.8 Terminating resistor 120 Ω (0.5 W) Switching elements Switching components changeover contacts: K1 (Alarm 1), K2 (Alarm2), K (device error, additionally selectable EDS alarm) Operating principle K1, K2 N/O or N/C operation Factory setting (Alarm 1/Alarm 2) N/O operation Operating principle K N/C operation Electrical endurance, number of cycles 12000 Contact class IIB (DIN IEC 60255-2) Rated contact voltage AC 250 V/DC 00 V Making capacity AC/DC 5 A Breaking capacity 2 A, AC 20 V, cos phi = 0.4 0.2 A, DC 220 V, L/R = 0.04 s Contact rating at DC 24 V 2 ma (50 mw) Environment/EMC EMC acc. to IEC 6126-2-4 Ed. 1.0 Shock resistance IEC 60068-2-27 (device in operation) 15 g/11 ms Bumping IEC 60068-2-29 (transport) 40 g/6 ms Vibration resistance IEC 60068-2-6 (during operation) 1 g/10 150 Hz Vibration resistance IEC 60068-2-6 (transport) 2 g/10 150 Hz Ambient temperature (during operation) -10 +55 C Ambient temperature (during storage) -40 +70 C Climatic class acc. to DIN IEC 60721-- K5 Connection Connection screw-type terminals Connection properties rigid/flexible 0.2 4 mm²/0.2 2.5 mm² flexible with ferrules without/with plastic sleeve 0.25 2.5 mm² Conductor sizes (AWG) 24 12 Other Operating mode continuous operation Mounting display-oriented Distance to adjacent devices 0 mm Degree of protection, internal components (DIN EN 60529) IP0 Degree of protection, terminals (DIN EN 60529) IP20 Degree of protection, for door mounting (DIN EN 60529) IP40 Degree of protection, for door mounting with panel sealing (DIN EN 60529) IP42 Degree of protection, for mounting the transparent front plate cover (DIN EN 60529) IP65 Type of enclosure: suitable for panel mounting free from halogen Flammability class UL94 V-0 Documentation number D00089 Weight 900 g Option W Shock resistance IEC 60068-2-27 (device in operation) 0 g/11 ms Bumping IEC 60068-2-29 (transport) 40 g/6 ms Vibration resistance IEC 60068-2-6 1.6 mm/10 25 Hz 4 g/25 150 Hz Ambient temperature, during operation -25 +70 C Ambient temperature, during operation > 55 C (not for continuous operation in the insulation fault location mode with 50 ma) Ambient temperature for storage -40 +85 C The data labelled with an * are absolute values ** = Under EMC test conditions in accordance with IEC 6126-2-4 the specified tolerances can double 6 IRDH575_D00089_02_D_XXEN/09.2018

Ordering information Permissible extraneous Nominal system voltage Un Supply voltage US DC voltage U fg Type Art. No. DC AC DC AC DC 19.2 72 V IRDH575B1-427 B91065502 20 575 V 20 575 V 77 286 V 88 264 V IRDH575B1-45 B91065500 810 V 19.2 72 V IRDH575B1-4227 1) B91065505 20 150 V 20 150 V 77 286 V 88 264 V IRDH575B1-425 B91065504 1060 V 40 760 V 40 575 V 19.2 72 V IRDH575B2-427 B91065506 77 286 V 88 264 V IRDH575B2-45 B9106550 1) Measuring voltage Um 10 V (version -4227) for usage in control circuits Device Option-W with increased resistance to shock and vibrations: Indicated by the letter W at the end of the order number. Suitable system components Designation Type Art. No. Dimension diagram X500 Dimensions in mm Panel seal for IP 42 B98060006 Transparent cover for IP 65 B98060007 Adapter for DIN rail mounting B98060010 Measuring instruments 9620-1421 B986841 9620S-1421 B986842 IRDH575_D00089_02_D_XXEN/09.2018 7

Bender GmbH & Co. KG P.O. Box 1161 501 Gruenberg Germany Londorfer Strasse 65 505 Gruenberg Germany Tel.: +49 6401 807-0 Fax: +49 6401 807-259 E-Mail: info@bender.de www.bender.de BENDER Group IRDH575_D00089_02_D_XXEN / 09.2018 / pdf / Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the edition valid until 09.2018 unless otherwise indicated.