NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

Similar documents
NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

Overcurrent Protection / 7SJ45

08/07/2015

Programmable AC Voltage Transducer MT416

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

08/07/2015

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

SWT 3000 Teleprotection technical data siemens.com

Programmable AC Current Transducer MT418

satech SynchroStar GPS 200 Series

Utility Communications Teleprotection Equipment TPT-200

MHCO MHCO-RI. General Characteristics The transducer MHCO provide a measurement of current or voltage fully isolated and safe.

SPECIFICATION FOR OVERCURRENT RELAYS

02/11/2015

Stabilized Differential Relay SPAD 346. Product Guide

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Power Meter Series PM9

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

AMIK 200 / 201 Technical Data Sheet

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Time over/underfrequency relay with protection assemblies

presentation contents application advantages

PART NUMBERING SYSTEM

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

IRIG-B Interface (De-modulated) External clock synchronization signal IRIG format B00X

Instantaneous Overcurrent Relay

02/11/2015

Power Meter Series PM3200 Functions and characteristics

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

PART NUMBERING SYSTEM

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

RE17LLBM asymmetrical flashing relay s V AC - solid state output

SAMSUNG ELECTRO-MECHANICS CO., LTD

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

ASHIDA Numerical 3OC + 1EF Protection Relay

02/11/2015

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Data Sheet. RISH Master Record %THD

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Type CP-S, CP-C & CP-A Switch mode

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

)HDWXUHV Voltage restraint overcurrent stage with five different inverse or definite time characteristics

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Digital Multifunction Instrument - Rish Master 3440

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Analog signal converters CC-E I/I

RENF22R2MMW Zelio Timer Relay - Modular

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

ASHIDA Numerical Directional 3OC + 1EF Protection Relay

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

02/11/2015

02/11/2015

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

SAMSUNG ELECTRO-MECHANICS CO., LTD

PLC-K506 Series FEATURES DESCRIPTION FEATURES

SPECIFICATION. Online UPS 3000VA

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

DOBLE F6150SV TECHNICAL SPECIFICATIONS

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Digital Grid Products. SICAM Fault Sensor Indicator (FSI) The Guardian for your Overhead Line Networks

VOLTAGE DETECTING SYSTEMS

DOBLE F6150e TECHNICAL SPECIFICATIONS

Transformer differential protection

RS Pro ENGLISH. Datasheet

05/09/2012

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

Protection components

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

22/10/2012

Customer: Standard type Page 1 of 7 Description Fluxgate current sensor with toroidal core PCB mounting

Type Nominal voltage (V) Code HSV V

Technical Data Sheet. x1000. kwh R Y B

RS Pro ENGLISH. Datasheet

SPAE 010, 011 High Impedance Protection Relay

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Protection and control. Sepam range Sepam 100 LA Self-powering protection. Merlin Gerin Square D Telemecanique

Introduction DIN rail mounted electricity meters

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

Network Analyzer for Low-, Medium- and High-Voltage Networks

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Technical Data Sheet AMIK 300 / 301

Transcription:

REGULATION AUTOMATIC SYNCHRONIZER for GENERATOR NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds a voltage adjustment function. These two devices also include CB time compensation allowing paralleling without phase shift. As well as the usual protection functions, NP800 relays provide monitoring, measurement and recording of the electrical quantities of the network. The relays can be set by the RS232 port, or remotely using the RS485 port. Reading, measurement and recording are all available locally or remotely. Multifunction Measurement Recording / event log Disturbance recording NPRG860 Local MMI NPRG870 Common functions Regulating device - [90] Synchrocheck for manual paralleling - [25] Anticipated closing time of the paralleling circuit breaker [TA] Dead Busbar paralleling Adjustment of the phase shift between GE and BB measurements (Step up transformer adaptation) Network configurable rated voltage Speed adjustment (NPRG860-NPRG870) ± speed order Boost pulsing Voltage adjustment (NPRG870) ± U order Multi-groups management function (NPRG870) 4 settings tables available for management of 4 generators

Auxiliary Supply Auxiliary supply ranges Typical burden Memory backup Analogue Inputs Phase voltage inputs Frequency (50Hz or 60Hz) 19 to 70 85 to 255 / Vdc or Vac 50 or 60 Hz 6 W (CC), 6 VA (CA) 72 hours Un: 55 to 120 V input impedance > 80 KΩ continuous rating 240 V, short duration withstand 275V - 1 min measurement from 3 to 240 V VT setting: primary value from 100 V to 30 kv measurement: 45-55 Hz or 55-65 Hz Digital Inputs (4 for NPRG860, 8 for NPRG870) Polarizing voltage 20 to 70 Vdc, range 19 to 70 V 37 to 140 Vdc, range 85 to 255 V Level 0 < 10Vdc range 19 to 70 V < 33Vdc range 85 to 255 V Level 1 > 20Vdc range 19 to 70 V > 37Vdc range 85 to 255 V Burden < 15 ma Relay Outputs (3* for NPRG860 + 1 WD, 7 for NPRG870 + 1 WD) Relays A*, B*, E, F double contact NO, permanent current 8 A closing capacity 12 A / 4 s short circuit current withstand 100 A / 30 ms breaking capacity DC with L/R = 40 ms: 50 W breaking capacity AC with cos φ = 0.4: 1250 VA Relays C*, WD, D, G changeover contact, permanent current 16 A closing capacity 25 A / 4 s short circuit current withstand 250 A / 30 ms breaking capacity DC with L/R = 40 ms: 50 W breaking capacity AC with cos φ = 0.4: 1250 VA Characteristics of the function [90] Accuracy of voltage measures 3% of Un Setting of voltage difference: ± U thresholds +/- : 1% to 15% Un, with step of 1% Un Voltage difference accuracy ± 5% of the set value Setting of angular difference: thresholds +/- : 1 to 20, with step of 1 Angular difference accuracy ± 2% Setting of frequency difference: ± F thresholds +/- : 0.01 to 1.5 Hz, with step of 0.01 Hz Frequency difference accuracy ± 2% Setting of rate of frequency change: thresholds +/- : 0.01 to 0.2 Hz/s, with step of 0.01 Hz/s F/dt Rate of frequency change accuracy ± 2% Threshold of amplitude U GE mini 50 to 100% Un, with step of 1% Threshold accuracy 2% of Un Closing time of the paralleling CB (TA) 0 ms to 600 ms, with step of 10 ms Anticipatory max (limitation / TA) 1 to 20, with step of 1 Accuracy of the time delays Accuracy of displayed measures 3% from 3 to 240 V Characteristics of the function [25] Accuracy of voltage measures 3% of Un Setting of voltage difference: ± U thresholds +/- : 1% to 15% Un, with step of 1% Un Voltage difference accuracy ± 5% of the set value Setting of angular difference: thresholds +/- : 1 to 20, with step of 1 Angular difference accuracy ± 2% Setting of frequency difference: ± F thresholds +/- : 0.01 to 1.5 Hz, with step of 0.01 Hz Frequency difference accuracy ± 2% Setting of rate of frequency change: thresholds +/- : 0.01 to 0.2 Hz/s, with step of 0.01 Hz/s F/dt Rate of frequency change accuracy ± 2% Time lag before authorisation 0 ms to 1 s, with step of 0.1 s Accuracy of the time delays Accuracy of displayed measures 3% from 3 to 240 V

Adjustment of the phase shift between GE and BB measurements GE voltage / BB voltage 0 to 360, with step of 1 Network rated voltage configuration Setting range 100 V to 30 kv Speed adjustment (NPRG 860/NPRG 870) Interval of the pulses ±f 0 to 30 s, with step of 1 s Mini duration time of the pulses ±f 0 to 0.5 s, with step of 0.1 s Proportional gain (KFP±*) ±f 0 to 200, with step of 1 Derivative gain for (KFD±**) ±f 0 to 100, with step of 1 Boost pulsing time-delay 10 to 200 s, with step of 1 s Accuracy of the time delay Duration of the pulses +f (boost pulsing) 0.5 to 10 s, with step of 0.5 s Orders stop if paralleling ok YES/NO *: 5 Hz correspond to 20 s **: 1 Hz/s correspond to 200 s Voltage adjustment (NPRG870) Interval of the pulses ±U 0 to 30 s, with step of 1 s Mini duration time of the pulses ±U 0 to 0.5 s, with step of 0.1 s Proportional gain (KUP±*) ±U 0 to 100, with step of 1 *: 10% de U correspond to 5 s Dead Busbar paralleling (NPRG 870) Dead busbar paralleling enabled by dedicated DI or setting software Info dead busbar paralleling enabled HMI, dedicated DI, communication and setting software Busbar voltage detection threshold 10% to 50% Un, with step of 1% Un Threshold accuracy 2% of Un Setting of frequency difference thresholds F< and F>: 0 to 1 Hz, with step of 0.1 Hz Angular accuracy / frequency difference ± 2% Setting of voltage difference thresholds U< and U>: 1 to 10% Un, with step of 1% Un Voltage difference accuracy ± 5% of the set value Time lag before paralleling 1 to 5 s, with step of 0.5 s Accuracy of the time delay Digital inputs assignment Input 1 paralleling of dead bus line Input 2 auto mode Input 3 order function enabled Input 4 synchrocheck mode Input 5 (NPRG870 only) selection generator 1 Input 6 (NPRG870 only) selection generator 2 Input 7 (NPRG870 only) selection generator 3 Input 8 (NPRG870 only) selection generator 4 Digital output assignment Relay A Relay B Relay C Relay D (NPRG870 only) Relay E (NPRG870 only) Relay F (NPRG870 only) Relay G (NPRG870 only) Signalling LEDs assignment LED 1 LED 2 LED 3 LED 4 +f order - f order paralleling order generator selection fault +U order - U order paralleling of dead bus line enabled auto mode activated paralleling of dead bus mode activated slip control paralleling order Setting Display English, French, Spanish, Italian Configuration and operating software compatible with Windows 2000, XP, Vista and 7 English, French, Spanish, Italian

MODBUS Communication (option) Transmission asynchronous series, 2 wires Interface RS 485 Transmission speed 300 to 115 200 bauds Disturbance recording Number of recordings 4 Total duration 170 cycles per recording (12 samples / cycle) Pre fault time adjustable from 0 to 170 cycles Climatic withstand in operation Cold exposure IEC / EN 60068-2-1: class Ad, -10 C Dry heat exposure IEC / EN 60068-2-2: class Bd, +55 C Damp heat exposure IEC / EN 60068-2-3: class Ca, 93 % HR, 40 C, 56 days Temperature variation with specified IEC / EN 60068-2-14: class Nb, -10 C à +55 C, 3 C/min variation rate Storage Cold exposure IEC / EN 60068-2-1: class Ad, -25 C Dry heat exposure IEC / EN 60068-2-2: class Bd, +70 C Electrical safety Ground bond test current Impulse voltage withstand Dielectric withstand: 50Hz Insulation resistance Clearances and creepage distances Enclosure safety Degrees of protection provided by Immunity Conducted disturbances Immunity to RF conducted disturbances Fast transients Oscillatory waves disturbance 1 MHz Surge immunity Supply interruptions IEC / EN 61010-1: 30 A IEC / EN 60255-5: 5 kv MC, 5 kv MD except outputs TOR, 1 kv MD except RS485, 3 kv MC IEC / EN 60255-5: common mode 2 kv rms 1 min differential outputs mode TOR 1 kv rms 1 min (open contact type) IEC / EN 60255-5: 500 Vcc - 1 s: > 100 MΩ IEC / EN 60255-5: rated insulation voltage: 250 V pollution degree: 2 overvoltage category: III IEC / EN 60529: IP51, with front face enclosures (IP code) IEC / EN 61000-4-6: class III, 10 V IEC / EN 60255-22-4 / IEC / EN 61000-4-4: class IV IEC / EN 60255-22-1: class III, 2.5 kv MC, 1 kv MD except RS485, class II, 1 kv MC IEC / EN 61000-4-5: class III IEC / EN 60255-11: 100% 20 ms Immunity Radiated disturbances Immunity to RF radiated fields IEC / EN 60255-22-3 / IEC / EN 61000-4-3: class III, 10 V/m Electrostatic discharges IEC / EN 60255-22-2 / IEC / EN 61000-4-2: class III, 8 kv air / 6 kv contact Power frequency magnetic field IEC / EN 61000-4-8: class IV, 30 A/m permanent, Immunity test 300 A/m 1 to3 s Mechanical robustness - energised Vibrations Shocks CEI / EN 60255-21-1: class 1, 0.5 Gn IEC / EN 60255-21-2: class 1, 5 Gn / 11 ms Mechanical robustness - not energised Vibrations IEC / EN 60255-21-1: class 1, 1 Gn Shocks IEC / EN 60255-21-2: class 1, 15 Gn / 11 ms Bumps IEC / EN 60255-21-2: class 1, 10 Gn / 16 ms Free falls IEC / EN 60068-2-32: class 1, 250 mm

Electromagnetic compatibility (EMC) Radiated field emissivity Conducted disturbance emissivity EN 55022: class A EN 55022: class A Presentation Height 4U Width ¼ 19" Brackets 19 rack mounting option (see drawing D37739) Display 2 lines of 16 characters Case H, W, D without connectors 173 x 106.3 x 250 mm (see drawing D37739) Net weight 3.6 kg Connection - codification NPRG860 NPRG870 see diagram S38894 see diagram S38895 SMARTsoft SMARTsoft, integrated software for the Industry, Railway and Transmission ranges, helps the User get the best from NP800 series relays. SMARTsoft User friendly Diagnosis Fault analysis Maintenance tools

Functionalities 2 ranges of auxiliary supply Storage of lack and the restoration of the auxiliary voltage (events recorded) Configuration and parameter setting by off-line / online PC Reading and recording of configuration by PC Measurement of electrical quantities: Phase voltages U GE, U BB Frequency F GE, F BB Voltage difference U (U GE U BB ) Angular difference Angular difference compensate (NPRG870) Frequency difference F (F GE F BB ) Rate of frequency change F/dt (Hz / s) CB closing time (ms) Phi anticipatory ( ) Display expressed in primary values 4 setting groups for management of several selectable groups remotely by logical input (NPRG870 only) Setting software compatible with Windows 2000, XP, Vista and 7 User interface with access to all functions Time stamping of internals events with 10ms resolution Time stamping of digital inputs with 10ms resolution Event recording: 250 locally recorded events, 200 saved in case of loss of the auxiliary supply Local / remote events acknowledgment Disturbance recording according to Comtrade format: storage of 4 recordings of 170 periods. Remote setting, remote reading of measurements, alarms and parameters settings Remote reading of disturbance recording and events log Self-diagnosis: Memories, output relays, A/D converters, auxiliary supply, cycles of execution of the software, hardware anomaly Options Communication by Modbus RS 485 Communication by Modbus RS 485 with redundancy (NPRG870 only) Functional diagram (For Synchrocheck and manual paralleling, Dead Busbar paralleling and Multi-groups management function, see NP800 application guide) { Only documents supplied with our acknowledgment are to be considered as binding. 11, rue Marcel Sembat - F94146 Alfortville cedex www.groupeice.com - contact@icelec.com Tel : +33 (0)1 41 79 76 00 - Fax : +33 (0)1 41 79 76 01 A425B