Mini Clamp Meter Model:

Similar documents
Model: &

Digital Clamp Meter Model: &

True RMS Digital Multimeter Model:

MODEL: D03128 CLAMP METER

Digital Multimeter, Pen Type

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

AC/DC CLAMP METER USER S MANUAL

DIGITAL MULTIMETER AUTORANGING

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

UT207A/208A/209A Operating Manual. Table of Contents

Pocket Size Digital Multimeter Models: and

CONTENTS MS2033A. 1.Introduction Safety Information...01

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Multifunction Digital

Digital Multimeter with Backlight

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

DCM730. Digital Clamp Meter User s Manual

NOTE: Fully read and understand this manual before using this Digital Multimeter.

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

400Amp True RMS AC/DC Clamp Meter Model EX613

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

KMD-S04 Multímetro de bolsillo

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

AMM-1022 Digital Multimeter USER`S MANUAL

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

USER'S MANUAL DMR-6700

Pen-type DIGITAL MULTITESTER

ET-3888 True RMS Clamp Meter. User Manual

The Meter Structure The Figure 2-1 shows the Meter structure.

User Manual. All rights reserved. Specifications are subject to change without notice.

User Manual Digital Clamp Multimeter. model no.: MSR-C600

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Pocket Size Digital Multimeter with USB Model: A & A

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

LCR METER Model:

DVM1190 DIGITAL MULTIMETER

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

LCR METER Model:

User Manual. All rights reserved. Specifications are subject to change without notice.

R/C SMD Tweezers Multimeter Model RC200

OPERATOR S INSTRUCTION MANUAL

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

METRAVI. Table of Contents

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

Model UT10A: OPERATING MANUAL Table of Contents (1)

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

312, 316, 318. Clamp Meter. Users Manual

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Digital automotive analyser 13 function with ic

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

Digital Automotive Analyser 14 Function With IC

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

400Amp True RMS AC Clamp Meter + NCV

ProfiScale MULTI Multimeter

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

OPERATOR S INSTRUCTION MANUAL

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

User s Guide. 400A AC/DC Clamp Meter. Model MA220

MS8223A. CAT.IIi 600 V

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Sales: Technical: Fax:

200Amp AC Clamp Meter + NCV Model MA250

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

MS2109A AC/DC Clamp Meter. User Manual. Contents

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

Dawson DDM190. Digital Multimeter User s Manual

IDM 98-III & IDM 99-III Digital Multimeters

MS2030 CAT III 600 V A V AUTO RS232

Not for Reproduction

Autoranging Multimeter Extech EX503

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Model : OPERATING MANUAL Table of Contents (1)

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

DIGITAL MULTIMETER INSTRUCTION MANUAL

DM-46 Instruction Manual

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

79/26 Series III Multimeter

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

DDM350 Pen-Type Digital Multimeter User s Manual

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

Transcription:

Mini Clamp Meter Model: 72-2985 1

CONTENTS Page Number Details 2 What s Included 3 Important Safety Information 3 Technical Specification 4 Product Overview 5 LCD Overview 6 Operation - AC/DC Voltage Measurement 6 Resistance/Circuit On-Off/Diode/Capacitance 6 AC/DC Current Measurement 7 NCV Non-contact Electric Field Measurement 7 Other Functions 8 Technical Index 8 DC Voltage Measurement 8 AC Voltage Measurement 8 Resistance Measurement 9 Circuit On-Off, Diode Measurement 9 Capacitance Measurement 9 DC Current Measurement 9 AC Current Measurement 10 Cleaning & Maintenance WHAT S INCLUDED One mini clamp meter One pair of probe assemblies One zip case One user manual 2

Please read these instructions carefully before use and retain for future reference. IMPORTANT SAFETY INFORMATION When using electrical appliances basic safety precautions should always be followed. Use the meter only as specified in this manual, or the protection provided may be impaired. Do not operate the meter or use test leads if they appear damaged, or if the meter is not operating properly. Check before each use. There are no user-serviceable parts in this product. Refer servicing to qualified personnel. Do not use the clamp meter in a circuit with voltage higher than 600V or frequency higher than 400Hz. Be cautious when working in an environment with exposed conductors. Contact with conductors may result in electric shock. Use caution with voltages above 60V DC, 30V AC rms or 42V AC (peak value). These voltages pose a shock hazard. Before removing the battery cover, remove the clamp meter from all energized circuits and disconnect the lead. Replace the batteries as soon as the low battery indicator appears on the display. Fit a full set of batteries at one time. Remove dead batteries from the meter or if it is not going to be used for a long time. Never mix old and new batteries together, or different types of batteries. Never dispose of batteries in a fire, or attempt to recharge ordinary batteries. TECHNICAL SPECIFICATION Max. voltage between input terminal and earthing 600V Max. overload protection for clamp head terminals 100A Max. display 2000 counts, update 2-3 times per second Over range display Displays OL Diode (approx) 3.2V Range Automatic Polarity Automatic Work temperature 0 C ~ 40 C Relative humidity 0 C ~ 30 C: 75%, 30 C ~ 40 C: 50% Storage temperature -10 C ~ 50 C 3

Electromagnetic compatibility (In 1V/m radio frequency field) Overall frequency = designated precision + 5%, radio frequency field above 1V/m has no designated index Working altitude 0~2000m Built-in batteries 2 x AAA 1.5V Low battery LCD displays Dimensions (approx.) 175 x 60 x 33.5mm, max. clamp head size is 17mm Weight (approx.) 170g (including batteries) PRODUCT OVERVIEW 1. Clamp head 2. Protective barrier 3. Clamp head trigger: press the trigger to open the clamp head. 4. NCV Indicator: when the induced AC electric field intensity and induction distance satisfy the designated value, the indicator will flash. 5. Function selection button: rotate to select the functions indicated. 6. HOLD/backlight key: press and hold to turn on or off the display backlight. 7. ZERO key: used for DC current zero, capacitance/ voltage measurement relative value. 8. SELECT key: select function mode, such as ACV/ DCV, resistance/on-off/diode/capacitance, ACA/DCA etc. in AC voltage and current gear. Press and hold for more than 2 seconds to enter or exit VFC function. 9. LCD screen 1 2 3 6 7 9 10 11 10. Positive terminal input jack: when measuring voltage, resistance/on-off/ capacitance/diode, insert the red meter plug into this jack. 11. Input jack at COM terminal: when measuring voltage, resistance/on-off/ capacitance/diode, insert the black meter plug into this jack. 12. Indication mark for geometric centre of clamp head. 72-2985 12 4 5 8 4

LCD OVERVIEW Indicator TRMS AC/DC Ω kω MΩ Hz, khz, MHz mv, V ma, A nf, µf, mf (EF) NCV Auto ZERO/REL VFC Meaning True valid value measurement status AC/DC voltage measurement Negative reading Diode measurement Circuit continuity measurement Data hold Resistance unit Frequency unit Voltage unit Current unit Capacitance unit Non-contact AC voltage induction Auto range Zero/relative measurement Variable frequency voltage/current measurement Low battery Auto power-off 5

OPERATION - AC/DC VOLTAGE MEASUREMENT Select AC voltage or DC voltage range. Insert the red meter plug into the red jack (positive terminal) and the black meter plug into the black jack (COM terminal). Touch the test piece with the red and black meter plugs. Read the measurement value from the LCD. WARNING: When measuring voltage, the maximum input voltage is 600V (AC/DC). Do not exceed this limitation, otherwise it may cause an electric shock. RESISTANCE/CIRCUIT ON-OFF/DIODE/CAPACITANCE Insert the red meter plug into the red jack (positive terminal) and the black meter plug into the black jack (COM terminal). Connect the meter plug in parallel to the test piece for measurement. Read the measurement value from the LCD screen. WARNING: When measuring resistance/on-off/ capacitance/diode range, do not input voltage over DC 60V or AC 30V to avoid injury. AC/DC CURRENT MEASUREMENT AC Select AC range (2A~, 20A~, 100A~). Open the clamp head, insert the electric wire and close the clamp head. Ensure the electric wire is held in the geometric centre, indicated on the clamp head and make sure the clamp heads are closed. Read the measurement data from the LCD. DC Press SELECT to enter DC range (2A, 20A, 100A ). Press ZERO before measurement to set the reading to zero. If it does not return to zero after one press, then press it several times until the reading is zero. Note: As the product is highly sensitive, to ensure correct data measurement, the orientation of the meter during measurement should be the same as when zeroed. 6

Open the clamp head, insert the electric wire and close the clamp head. Ensure the electric wire is held in the geometric centre, indicated on the clamp head and make sure the clamp heads are closed. Read the measurement data from the LCD. When the reading is positive it means the current flows from the positive side to the negative side and vice versa. NCV NON-CONTACT ELECTRIC FIELD MEASUREMENT If you want to measure whether there is AC voltage/ electromagnetic field, place the front end of the clamp head 8~15mm close to the test piece. When the amplitude of the inductive AC voltage is approximately 100V, it displays EF. If the detected voltage is > 100V, it displays - and it has four ---- levels based on voltage with different buzzing at each level with NCV light flashing to proportionate to the field intensity. WARNING: When ranges switch to NCV measurement, unplug the test plug to avoid electric shock. OTHER FUNCTIONS Press and hold the HOLD button for two seconds to turn on or off the LCD backlight function. Automatic power-off: If the rotary button has not been moved for 15 minutes the instrument will automatically switch off to save energy. Turn the rotary button to OFF, then select the required range, or press any button. To turn off the automatic power-off function, press and hold the SELECT key, then turn the instrument on. You will hear five buzzing sounds, which means the automatic power-off function has been cancelled. Turn off and restart the meter, and the automatic power-off function will be reenabled. The buzzer will send out five warnings one minute before the automatic power-off. A long buzz will then be heard before turning off. When the automatic power-off function is cancelled, you will hear five continuous warnings every 15 minutes. Buzzer: press any button or rotate the function switch. If such function key is valid, the buzzer will beep once. When the circuit under test is conductive (<10Ω), the buzzer will sound continuously. When measuring voltage or current out of range, the buzzer will beep to indicate this. - When AC or DC voltage is >600V, the buzzer will beep. - When AC or DC current is >100A, the buzzer will beep. Low voltage detection: when the battery voltage is lower than 2.5V, the low battery symbol appears. Measurement accuracy may be lower once this symbol shows, so replace the battery as soon as possible. If it is lower than 2.2V, only the low battery symbol will show after starting up and the instrument will not work. When the battery supply voltage lowers to 2.6V, the LCD backlight will be in weak or non-functional state, but the measurement functions will still work. 7

TECHNICAL INDEX Accuracy: ± (a% reading + b count). Environment temperature: 23 C ± 5 C (73.4 F ± 9 F), relative humidity: 75%. DC VOLTAGE MEASUREMENT 200.0mV 0.1mV ± (0.7% + 5) 2.000V 1mV 20.00V 10mV 200.0V 100mV ± (0.7% + 3) 600V 1V Input impedance: approx. 10MΩ. As the input impedance on the meter is high, when measuring a source of lower voltage and lower impedance (less than 10MΩ), the measurement may be unstable for a short time, but will stabilize. Warning: Maximum input voltage: ±600V AC VOLTAGE MEASUREMENT 2.000V 1mV 20.00V 10mV ± (1.0% + 3) 200.0V 100mV ± (1.0% + 3) VFC mode: ± (4.0% + 3) 600V 1V ± (1.2% + 3) VFC mode: ± (4.0% + 3) RESISTANCE MEASUREMENT Input impedance: approx. 10MΩ. Show true virtual value: frequency response: 45~400Hz. Accuracy guarantee range: 5-100% range, short circuit allows <10 residue readings. Non-sinusoidal wave counts add error by crest factor: - When crest factor is 1~2, add 3%. - When crest factor is 2~2.5, add 5%. - When crest factor is 2.5~3, add 7%. Warning: Maximum input voltage: 600Vrms. 200.0Ω 0.1Ω 2.000kΩ 1Ω 20.00kΩ 10Ω ± (1.0% + 2) 200.0kΩ 100Ω 2.000MΩ 1kΩ 20.00MΩ 10kΩ ± (1.2% + 3) Range: measured value = measurement display value - meter pen short circuit value. Open circuit voltage is about 1V. Overload protection: 600Vrms. 8

CIRCUIT ON-OFF DIODE MEASUREMENT Range Resolution Remarks 0.1Ω 1mV Resistance value for circuit disconnect: >150Ω, buzzer makes no sound. Open circuit voltage is 3.2V: normal voltage for silicon PN junction is 0.5~0.8V. Overload protection: 600V rms CAPACITANCE MEASUREMENT 2nF 1pF ± (4.0% + 10) 20.00nF~200.0µF 10pF~100nF ± (4.0% + 5) 2.000mF~20.00mF 1µF~10µF ± 10% Overload protection: 600V rms 1µF measured capacitance. It is suggested to use ZERO measurement mode to ensure accuracy. DC CURRENT MEASUREMENT 2.000A 1mA ± (2.0% + 8) 20.00A 10mA ± (2.0% + 3) 100.0A 100mA ± (2.0% + 3) AC CURRENT MEASUREMENT Overload protection: 100A. Due to the presence of external electromagnetic fields, press ZERO before measurement to ensure accuracy of measurement. Note: If the reading does not zero after the initial press, press it several times until the reading is zero. The orientation of the meter during measurement should be the same as when zeroed. 2.000A 1mA ± (3.0% + 10) VFC mode: ± (4.0% + 10) 20.00A 10mA ± (2.5% + 8) VFC mode: ± (4.0% + 10) 100.0A 100mA ± (2.5% + 5) VFC mode: ± (4.0% + 10) Overload protection: 100A. Accuracy warranty coverage: 5~100% range, 2A open circuit allows <20 residue readings. Displays are rms value. Frequency response: 50~60Hz. Non-sinusoidal wave counts add error by crest factor: - When crest factor is 1~2, add 3%. - When crest factor is 2~2.5, add 5%. - When crest factor is 2.5~3, add 7%. 9

CLEANING & MAINTENANCE WARNING: Before removing the rear cover of the instrument, make sure that the meter is switched off, the meter plugs have been removed from the input port and the lead disconnected from the circuit under test. To clean the instrument, use a clean damp cloth and a mild detergent. Do not use any chemicals, abrasives or solvents that could damage the meter. If any maintenance is required, refer to qualified personnel. Replacing the Batteries When the LCD displays the low battery symbol, replace the batteries immediately to preserve measurement accuracy. Move the rotary switch to the OFF position and remove the meter plug from the input jack. Unscrew the screw on the rear cover of the battery and remove the old batteries. Replace both batteries with replacements of the same specification (AAA 1.5V). INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT. This symbol indicates that separate collection of Waste Electrical and Electronic Equipment (WEEE) or waste batteries is required. Do not dispose of these items with general household waste. Separate for the treatment, recovery and recycling of the materials used. Waste batteries can be returned to any waste battery recycling point which are provided by most battery retailers. Contact your local authority for details of the battery and WEEE recycling schemes available in your area. 10 Made in China. www.premierfarnell.com V.1.0