Electrosurgery Units (ESU s) and their variants

What tests should be done?

perioperativecpd.com The basics of diathermy

J-470 ELECTROSURGE. Radio Frequency Electrosurgery Unit. Operation Instructions

Andy Falconer. Principles of surgical diathermy

RAISING THE LEVEL OF PROTECTION IN YOUR ORS

Application Notes. Electrosurgical Analyzer Primer

RF leakage current in electrosurgical units: Influence of the layout in taking measurements

ELECTROSURGICAL GENERATOR USER S GUIDE

White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe

ESU-2000 Series Product Overview

EXCELL NHP/T. A new step AheAd to the future ELECTROSURGICAL UNITS FOR MONOPOLAR AND BIPOLAR USE ISO ALSA IT ISO

User s Guide Aaron 950

Low / Medium Power Electrosurgery Review 2002

MICROWAVE DIATHERMY AND SURGICAL DIATHERMY DIATHERMICS

USER S GUIDE. User s Guide Bovie IDS-400

surtron.com SURTRON ELECTROSURGICAL units

Electrosurgery. KLS Martin ME MB 2 SAFETY BY EASY USE

MINIMAL ENERGY. MAXIMUM PRECISION. 1,2, The newest addition to Valleylab energy made to enhance the performance of your electrosurgical handpieces1,2,

HF- GENERATORS.

BOVIE SURGI-CENTER PRO. Electrosurgical Generator. User's Guide

QA-ES III Electrosurgical Analyzer

Meg1 (with Ligasmart)

User s Guide Aaron 940

PULSAR Generator Operator s Manual

QA-ES III Electrosurgical Analyzer

DIATERMO MB 122 AND MB 160 MONO-BIPOLAR W W

ELECTROSURGICAL UNIT ANALYZER

Operator s Manual E L E C T R O S U R G I C A L U N I T

Instruction Manual. (English-English)

LEEP System 1000 Table of Contents

DERM 941 DERM 942 High-Frequency Desiccators

ARC 200 HF SURGICAL GENERATOR SIMPLY SAFE

Innovating Together. An introduction to Electrosurgery

Electrosurgical Generator and Smoke Evacuation System Service Manual. Utah Medical Products, Inc. Catalog Numbers ESU-110 & ESU-220

Crossfire Footswitch. User Guide

INSTRUCTIONS ESG-400

Radio Frequency Electrosurgical System Specialist

D C 01/2019 3

ALSATOM SU MPC SU 50 MPC SU 100 MPC SU 140 MPC SU 140/D MPC SU 140/BD MPC

Endoscopy Equipment. D. J. McMahon rev cewood

DSL# EC 2009 Ethicon Endo-Surgery. All rights reserved PRODUCT CATALOG

Electrosurgery. KLS Martin ME 102. The compact Electrosurgical Unit with high Capacity

An Alternative Technique to Perform Surgeriesin Hospital by Surgical Diathermy

DIATERMO MB 122 AND MB 160 MONO-BIPOLAR W W

WHALETEQ. ESU Neutral Electrodes Impedance Tester. Model: HFPA150. User Manual

BENNING. CM7 Electrical Tester. Service Information

ERBE ERBOTOM ICC 300. Instruction manual 08.00

ERBE. ERBOTOM ICC 80 / 50 Instruction manual 08.00

Medical Video 2. Endoscopy Equipment. Bronchoscopy. Colonoscopy. Gastroscopy. Key Points Medical Video 2 - Endoscopy:

OPERATING MANUAL ELECTROSURGICAL UNIT

Surgitron Dual Frequency 4.0 MHz Radiowave Technology

U.S. ARMY MEDICAL DEPARTMENT CENTER AND SCHOOL FORT SAM HOUSTON, TEXAS ELECTROSURGICAL APPARATUS SUBCOURSE MD0363 EDITION 100

OPERATING MANUAL ELECTROSURGICAL UNIT

QUICK SETUP GUIDE SECULIFE ESPRO

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

troubleshooting LEVEL 1 training

Aquamantys 3 Pump Generator User Guide. Revision F

79/26 Series III Multimeter

Journal of Hepatology and Gastroenterology

GET MORE. WITH LESS. Less sticking. 1, Less cleaning. 2, Less eschar buildup. 2, More benefits. LigaSure Maryland jaw device with nano-coated jaws

ARC 350 HF ELECTROSURGICAL GENERATOR SIMPLY SAFE

radiosurg One device for all surgical treatments!

# Digital Multimeter

ELEKTROTOM 610. Operating Instructions. Valid from version 1130

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

LEEP PRECISION TM Generator

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

Lecture 4 Biopotential Amplifiers

Current-Programmed Mode Control Strategies for Electrosurgical Generators

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Multi range AC current clamps (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

GFL-1000 User Manual Ground Fault Locator

Fluke 125. Getting Started. Industrial ScopeMeter

Frequently Asked Question on Isolated Power Supply(IPS)

SureTest Model ST-1THD & ST-1THDC Instructions

Current Probes. User Manual

Rigel 377. Instruction Manual 367A550 Issue 2.0. Electrosurgical Analyser. August Seaward Group Issue 2.0

Model 4007DDS. 7 MHz Sweep Function Generator

BM VET 80, 120, 140, 180 W

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

(12) United States Patent (10) Patent No.: US 6,830,569 B2

maxium electrosurgery unit with maxium Beamer

USER MANUAL. Maxwell Technologies BOOSTCAP Energy Storage Modules. User Manual for 15V Modules: 20 F, 23 F, 53 F, 58 F 15 Volts DC

RF Amplifiers and RF Heating for Medical Applications FTF-IND-F0690

Voltage Probe Manual and Data North Star High Voltage, Inc. Rev January 2016

Owner s Manual 7000 WATTS RMS WATTS RMS COMPETITION D HIGH CLASS D AMPLIFIER HIGH CLASS D AMPLIFIER MADE IN KOREA

M30 SPOT WELDER INSTRUCTION MANUAL 230V 1PH.

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

LEAK CURRENT HiTESTER ST5540/ST Washington Street Melrose, MA Phone Toll Free

Electrical Multimeter

Model: &

Introduction to Medical Electronics Industry Test Analysis and Solution

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

5700A/5720A. Operator Guide. Series II Multi-Function Calibrator

Transcription:

Electrosurgery Units (ESU s) and their variants D. J. McMahon 150107 rev cewood 2017-12-23

Key Points Electrosurgical Units: - typical output frequency of modern ESU s (450-500 khz, but can be up to 5 MHz) higher frequency makes finer cut with less ancillary damage - difference in return circuit of monopolar and bipolar modes - difference in waveforms between Cut, Coag, and blend modes - principle of Return Electrode Monitoring (REM) - fulguration, desiccation, ablation, ligature (fulguration = sparking ESU to ablate tissue) - know what the crest factor is (indicates 'quality' of waveform; higher number = noisier) - Argon beam coagulators - hazards of return electrodes - know the principle of the harmonic scalpel - know where these units are used: - khz & MHz - Ω (REM resistance & impedance of tissue) - W (RF power output for cut & coag modes) - ma (RF leakage) not 60 Hz chassis leakage! - μa & Ω (electrical safety testing) - 'four' essentials of maintenance of ESU s: - REM, power, RF leakage, EST, and of course, document!

A little history: William T. Bovie, PhD Dr. Harvey Cushing

Electrosurgical Theory - Electrosurgery: application of a high-frequency electrical current to tissue to stop bleeding or to cut tissue. Desiccation: to dry-up (in the sense of removing fluid & blood) Ablation: removal of a layer of tissue Fulguration: use of sparking electrosurgery to remove (ablate) tissue Ligature: tying or binding something tightly; sealing a vessel with ESU Cautery: any application of heat to seal bleeding tissue Coagulation: formation of clot to seal bleeding tissue Hemostasis: the stopping of a flow of blood 9

Electrosurgical units are radio frequency (RF) generators: Typically 450-500 khz, but may be as high as 5 MHz (plastic surgery) higher frequency finer cut & less ancillary damage

The basic idea: ESU s are RF generators ESUs are little radio stations

Modulation of the RF for electrosurgical uses: Most usage is either Cut or Coag

Typical power range: 0-300 watts Typical power range: 0-120 watts

Cutting action - 100% duty cycle

Coagulation - highest voltage, lowest duty cycle. Higher voltage creates more heat, causing hemostasis.

Crest Factor or Peak-to-Average Ratio : Crest Factor = V peak V RMS ( eg, for a sine wave, CF = 1.41 pure DC would be 1.0) Crest Factor indicates the quality of a waveform. A high CF indicates a less efficient or noisier waveform. (because of the waveform, coag will have a high value)

Different tissues offer different impedances to RF: newer automatic ESU typical older ESU

Basic Monopolar Electrosurgery:

Bipolar mode cautery - (typical for neuro) (No need for a return pad) Current flows through insulated forceps Typical power range: 0-70 watts

RF Ablation: removal of a layer of tissue by use of localized RF (typical for heart, liver) also called fulguration

Safety Issues in ESU s: > External second site RF burns > Internal second site RF burns > RF interference on adjacent devices > Smoke plume > Fire

Effective distribution of RF energy to the return pad Tissue is burned where desired, but not on exit

Faulty contact of the return pad Tissue is burned where desired, and at the pad.

BAD: Alternate Site Burns in a Basic Monopolar System

CAUTION; GRAPHIC IMAGES AHEAD

BETTER: The Isolated Electrosurgical System

Isolated system is deactivated if the return path is opened, but burns can still occur if there is a path to ground.

BEST: the Return Electrode Monitoring (REM) system: Typical REM signal is 80 khz @ ~10µA Return pad has two conductive plates, which are monitored by the ESU for continuity. aka Contact Quality Monitoring

Internal second site burns during endoscopy:

Hazardous practices to be aware of: > Buzzing the hemostat: touching the active electrode to a hemostat (or several hemostats) clamped to tissue in order to save time. Can result in shocks or burns. > Wrapping the active lead wire around metallic instruments. > Stacking other medical electronics on or under the ESU. RF from the ESU can trigger or alter the function of other equipment.

ESUs are the primary source of ignition for O.R. fires. O.R. personnel are expected to take appropriate precautions: - Eliminate the use of alcohol-based prep solutions - Minimize fuel loading (flammable materials on & near the site) - Minimize oxygen flooding around the surgical site. - Have a fire extinguisher within ready access.

Smoke plume Smoke plume from electrosurgery is just as much a hazard to staff as is plume from lasers. - Gases and particulates are toxic and carcinogenic. OSHA and the AORN both encourage the routine use of smoke evacuators, high-filtration masks, and eye protection when using electrosurgical units. - Compliance has not been universal.

Smoke-evacuation for ESU s: older Valleylab

current Valleylab

Buffalo ViroVac

Megadyne Vac Plus

Variations on Electrosurgery: Argon Beam Coagulators - Essentially an enhanced ESU - still has cut, coag, bipolar - Use high voltage from the ESU to ionize a stream of Argon gas - Resulting plasma provides a cleaner, wider coagulating effect

Conmed s Argon Beam Coagulator model 7500

Valleylab s Force Argon argon beam coagulator used with their Force-FX

Variants on the ESU: Valleylab s Ligasure vessel-sealing system

electro-ligature

Proprietary Variants on Electrosurgery > Specific to a surgical procedure > Often use a higher frequency > 500kHz > Usually a surgeon s preference > Usually use a unique disposable

Arthrocare Corp: Coblator II for ENT surgery

Elmed 50-P: for Gynecological surgery

Medtronic Corp: Cardioblate for ablation of heart tissue

Hologic Corp: NovaSure for thermal ablation of the uterus http://www.novasure.com/info/novasure-and-heavy-periods/novasure-patient-animation.cfm

Somnus: Somnoplasty (for snoring)

Conmed s Hyfrecator - Low energy cautery, without a grounding pad - Often used in clinics, for smaller lesions

Hyfrecator output modes: Bipolar mode Monopolar with return pad Monopolar without pad

Variants on the ESU: The Harmonic Scalpel (Ethicon / Johnson & Johnson) -- NOT an electrosurgical unit -- Uses piezoelectric component to create an axial vibration (at ~56 KHz) at the surgical tip -- Use a variety of surgical probes and extensions specific to the surgical procedure -- Technically elegant; calibration pretty simple

Testing ESU s: (usually 500 Ω) Generic ESU tester > Derives a small DC voltage from the RF from the ESU > DC value is proportional to the output power

Functional Check: 1) Return Electrode Monitor (Ω) - Measure the resistance from the REM connector to ground: should be >20M Ω. - For single conductor return electrodes, verify that the unit alarms and does not deliver power if the resistance across the REM leads is >10 Ω. - For split pad return electrodes, verify that the unit alarms and does not deliver power if the resistance across the REM leads is < 5 Ω or >150 Ω. (Depends on the model - check the manual!)

Functional Check: 2) RF Power Output (W) - Use your analyzer or external non-inductive resistors as appropriate load impedances for Bipolar, Cut and Coag modes, (typically 100Ω, 300Ω, and 500Ω, resistive). - Test the unit in the Cut, Coag, and Bipolar modes, at a low power and at maximum power. - 5 watts for the low end - maximums typically 300W for Cut, 120W for Coag 70W for Bipolar - Power readings should be ±5W or ±15%

Functional Check: 3) RF Leakage (ma) (not 60 Hz current) - Configure the analyzer for RF Leakage - For any monopolar output, with appropriate load, RF leakage should be < 100mA (not µa!) - For the bipolar output, RF leakage should be < 60 ma. (Check the manual - some models allow 150mA)

Thorough testing an ESU includes power output tests at a variety of load impedances, in order to simulate the variable loads in the different types of tissue encountered by the active electrode during surgery. Current ESU analyzers enable the user to test in each mode and power setting at several impedances sequentially.

Functional Check: 4) Electrical Safety Check (Ω & μa) - per your department protocol and finally, Document! - the ESU control number is entered in the surgical record by nursing staff for each surgery. If there is any sentinel event, your maintenance record can be used in a legal action.

ESU Test Equipment - Fluke 454A (legacy)

ESU Test Equipment - Fluke QA-ES

ESU Test Equipment - BC Group s ESU-2300 Test setup with load resistors

Typical Troubleshooting - - Surgeons complain about poor output - Active lead wires increase resistance with age - Foot pedals fail from abuse - ESU signals cause interference on video displays - REM pad connectors break and become intermittent

Major Players in: General Electrosurgery: - Valleylab - Conmed - Erbe Argon Beam Coags: - Valleylab - Conmed Harmonic Scalpels: - Ethicon - Olympus

Valleylab Force 2 (legacy)

Valleylab Force FX

Valleylab switch for simple or split return pad

Valleylab s Force Triad : combines a Force FX with a Ligasure

Valleylab Surgistat II

Entermed ESG -01-01-21: 4.0 MHz, 130W Atmos RS 221 2.2MHz, 100W

Conmed

More information: Non-Valleylab ESU service website: www.servicingvalleylabgenerators.lefora.com Valleylab tech reference site: http://energysolutions.covidien.com/content/biomedconnect Nice history of electrosurgery: http://www.electrotherapymuseum.com/museum.htm Very nice review of electrosurgery principles, safety issues, and surgical video: http://www.youtube.com/watch?v=zehnjsyrlpk