ODEON APPLICATION NOTE Measurements with a Smart P hone

Similar documents
ODEON APPLICATION NOTE ISO Open plan offices Part 2 Measurements

IE-35 & IE-45 RT-60 Manual October, RT 60 Manual. for the IE-35 & IE-45. Copyright 2007 Ivie Technologies Inc. Lehi, UT. Printed in U.S.A.

ODEON APPLICATION NOTE Calculation of Speech Transmission Index in rooms

Airborne Sound Insulation

creation stations AUDIO RECORDING WITH AUDACITY 120 West 14th Street

ENGINEERING STAFF REPORT. The JBL Model L40 Loudspeaker System. Mark R. Gander, Design Engineer

Validation of lateral fraction results in room acoustic measurements

Case study for voice amplification in a highly absorptive conference room using negative absorption tuning by the YAMAHA Active Field Control system

Acoustic Calibration Service in Automobile Field at NIM, China

Click on the numbered steps below to learn how to record and save audio using Audacity.

Additional Reference Document

MUS 302 ENGINEERING SECTION

Acoustical Testing 1

79 First Avenue Mob: FIVE DOCK NSW 2046 VENTILATED ACOUSTIC ENCLOSURE NOISE EMISSION ASSESSMENT ACOUSTIC SERVICES & ADVICE

Measuring procedures for the environmental parameters: Acoustic comfort

Reverberation time and structure loss factor

BETTER SOUND FOR MOBILE APP. MicW i-series Mics Applications

How To... Commission an Installed Sound Environment

Dodecahedron Speaker Set

Introduction to Equalization

What you Need: Exel Acoustic Set with XL2 Analyzer M4260 Measurement Microphone Minirator MR-PRO

Technique for the Derivation of Wide Band Room Impulse Response

Pre- and Post Ringing Of Impulse Response

Application of a smartphone for introductory teaching of sound environment: Validation of the precision of the devices and examples of students work

Digitally controlled Active Noise Reduction with integrated Speech Communication

Impulse response. Frequency response

Figure 1. SIG ACAM 100 and OptiNav BeamformX at InterNoise 2015.

CHAPTER ONE SOUND BASICS. Nitec in Digital Audio & Video Production Institute of Technical Education, College West

AMPLITUDE MODULATION CASE STUDY AT THE LEONARDS HILL WIND FARM, VICTORIA, AUSTRALIA

PRODUCT DATA. DIRAC Room Acoustics Software Type Photo courtesy of Muziekcentrum Frits Philips, Eindhoven, The Netherlands

WinMLS I very much like the convenience of the tool and how quickly measurements can be made - Christopher Pye, Integral Acoustics, Canada

Genelec 1034B Control Room Monitoring System. Operating Manual

Operation Manual. LYD Series

Creating an urban street reverberation map

PD002. Product Data ZIRCON. Loudspeaker-Microphone Probe

APPLICATION NOTE MAKING GOOD MEASUREMENTS LEARNING TO RECOGNIZE AND AVOID DISTORTION SOUNDSCAPES. by Langston Holland -

Technical Guide. Installed Sound. Recommended Equalization Procedures. TA-6 Version 1.1 April, 2002

Digital Signal Processing Audio Measurements Custom Designed Tools. Loudness measurement in sone (DIN ISO 532B)

guitarfinetune User's guide Rev Eigil Krogh Sorensen

ACOUSTICS IN THE MULTIPURPOSE HALLS OF THE NEW MAIN LIBRARY AND THE NEW MUNCH MUSEUM IN OSLO

3D Intermodulation Distortion Measurement AN 8

L1 Model 1S TECHNICAL DATA SHEET. portable line array system. Key Features. Product Overview. Technical Specifications

DESIGN OF ROOMS FOR MULTICHANNEL AUDIO MONITORING

Product Information TLM 127. Large Diaphragm Microphone

SOUND FIELD MEASUREMENTS INSIDE A REVERBERANT ROOM BY MEANS OF A NEW 3D METHOD AND COMPARISON WITH FEM MODEL

29th TONMEISTERTAGUNG VDT INTERNATIONAL CONVENTION, November 2016

Primary Calibration of Solar Photovoltaic Cells At the National Metrology Centre of Singapore

Acoustic Measuring System

1037C and 1038B. Operating Manual Genelec 1037C and 1038B Tri-amplified Monitoring Systems

PRODUCT DATA. DIRAC Room Acoustics Software Type 7841

Measurement of weighted harmonic distortion HI-2

Lavalier microphone for smartphones USER MANUAL

Causes for Amplitude Compression AN 12

data sheet MS-HM.01 AUDIO SYSTEM FOR INTEGRATION INTO MEDIA BOARDS

CONTENTS. How to get started FINEQC calibration procedure 3

Making a Recording in the Booth

EQ s & Frequency Processing

SigCal32 User s Guide Version 3.0

ROOM SHAPE AND SIZE ESTIMATION USING DIRECTIONAL IMPULSE RESPONSE MEASUREMENTS

Surround: The Current Technological Situation. David Griesinger Lexicon 3 Oak Park Bedford, MA

THE ACOUSTICS OF A MULTIPURPOSE CULTURAL HALL

EBU UER. european broadcasting union. Listening conditions for the assessment of sound programme material. Supplement 1.

creation stations AUDIO RECORDING WITH AUDACITY 120 West 14th Street

INFLUENCE OF COAXIAL CABLE ON RESPONSE OF HIGH- VOLTAGE RESISTIVE DIVIDERS

Application Note. Airbag Noise Measurements

8000 Series. Operating Manual Genelec 8040A and 8050A Monitoring Systems

CHAPTER 3 THE DESIGN OF TRANSMISSION LOSS SUITE AND EXPERIMENTAL DETAILS

ONLINE TUTORIALS. Log on using your username & password. (same as your ) Choose a category from menu. (ie: audio)

New ON/OFF Absorption Technology That Includes Low Frequencies

Control of sound fields with a circular double-layer array of loudspeakers

Measurement at defined terminal voltage AN 41

F1 Model 812 Flexible Array Loudspeaker

Chapter 7: Signal Processing (SP) Tool Kit reference

PROFESSIONAL. EdgeMax EM90 and EM180 In-Ceiling Loudspeakers. Design Guide

datasheet TCS-40 TCS SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Dual 8 LF drivers Wide dispersion High power rating Down-fill enclosure

DESIGN OF VOICE ALARM SYSTEMS FOR TRAFFIC TUNNELS: OPTIMISATION OF SPEECH INTELLIGIBILITY

AUDIO INSTRUCTIONS CAPTURE STUDIO ONE PRO TOOLS

User Manual. This User Manual will guide you through the steps to set up your Spike and take measurements.

Okay, that s enough talking. Let s get things started. Here s the photo I m going to be using in this tutorial: The original photo.

Real time spectrum analyser sound level meters

SPECIFICATION OF ELECTRET CONDENSER MICROPHONE ( TO : ) All Parts are Halogen Free Material. Microphone Technology Leadership

group D DSA250 Specifications 2-WAY FULL-RANGE DIGITALLY STEERABLE ARRAY See TABULAR DATA notes for details CONFIGURATION Subsystem Features

NT1-A Instruction Guide

HT330A. Operating Manual Genelec HT330A Three-Way Active Loudspeaker

SigCalRP User s Guide

EFFECT OF STIMULUS SPEED ERROR ON MEASURED ROOM ACOUSTIC PARAMETERS

VENUE Full Isolation D.I.

UBL S119 LOUDSPEAKER SYSTEM

CLIO 10, by Audiomatica, is the new measurement software for the CLIO System. The CLIO System is the easiest and less expensive way to measure:

Low Cost Mobile Robotics Experiment with Camera and Sonar Sensors

T L Audio. User Manual EQ1 VALVE EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

1039A. Operating Manual Genelec 1039A Control Room Monitoring System

Transfer Function (TRF)

MOTIV TM. USB/iOS Microphones RECORD YOUR SOUND, YOUR WAY.

20 VOICE COIL. Figure 7: BlieSMA T34A-4 SoundCheck CSD waterfall plot

CONTENTS PREFACE. Chapter 1 Monitoring... 1 CHAPTER 2 THE MICROPHONE Welcome To The Audio Recording Basic Training...xi

Audacity Basic Podcast Tutorial

Loudspeaker Data Sheet

Technical Note Vol. 1, No. 10 Use Of The 46120K, 4671 OK, And 4660 Systems in Fixed instaiiation Sound Reinforcement

Suppose you re going to mike a singer, a sax, or a guitar. Which mic should you choose? Where should you place it?

Transcription:

Application note Measurements with a Smart Phone ODEON APPLICATION NOTE Measurements with a Smart P hone CLC, GK and JHR - Octoer 2013 Toys can e tools Scope This application note shows how to otain snap- shot measurements for further analysis on a PC using any edition of ODEON 12 with highly portale measurement equipment all you need is: 1. A smart phone. 2. A recording app (e.g. the Pfitzinger Voice Design field recorder (http://pfitzingervoicedesign.com/). 3. An omni directional microphone (i436 y MicW, www.micwaudio.com/ ). 4. Some alloons or even lighter some hand claps. 5. Any edition of ODEON version 12. The measurement equipment is extremely light weight and easy to set up compared to a full featured measurement system (dodecahedron loudspeaker, amplifier, PC, cales etc. ) yet it can provide decent measurement results for room acoustics parameters such as EDT, T20, T30, C80 (C80 is only availale in ODEON Auditorium and Comined). Therefore, there is little excuse not to make measurements when it may e useful. When visiting a site, while taking a few snap- shots for documentation using the camera in the Smart phone, y all means, as a room acoustician why not making a few acoustic snap- shots of the room? The main limitations of this method are that the very low frequencies may not e measurale, and a caliration of the sound source is not possile; thus the strength parameter (G) cannot e measured using this method, as this requires a calirated measurement system. 1

Equipment In contrast to a fully featured sweep- ased measurement using a PC with ODEON installed, a snap- shot measurement is carried out using an external impulsive stimulus, such as a hand clap or popping of a alloon. The external stimulus acts as the source, while the phone with microphone acts as the receiver. Smart phone An Android smart phone, Samsung Galaxy S2 plus, was used for this application note. Most smartphones (Android, iphone, Windows moile ) should e suitale for snap- shot measurements as the frequency response of the input and output of the device is not very critical for parameters like T 30 and C 80, which do not rely on calirated levels. Microphone For the measurements in this application note we have used the inexpensive omnidirectional microphone i436 y MicW (http://www.micwaudio.com/), which offers professional recording quality on a moile device. The microphone is availale in a package which includes cales and adapter that allows mounting it on a tripod. The directional characteristics and the frequency response of the microphone are shown in figure 1. Figure 1: The i436 microphone is a measurement microphone that complies with the IEC 61672 Class 2 sound level meter standard [1]. In contrast to the microphone in a Smart- phone which may not e a decent measurement microphone the i436 is omni directional, has an almost flat frequency response and has a Signal to noise ratio of 62 db. 2

Application note Measurements with a Smart Phone The recording app ODEON analyses.wav files. In order to record such files an app, which support this format, must e installed on the Smart- phone the app should also e capale of indicating if overload (clipping) occurs during the recording. Mono Figure 2: Screenshot of the Pfitzinger Voice Design field recorder. The Mono setting has to e used instead of Stereo. We have used the Pfitzinger Voice Design (PVD) Field recorder application that was purchased and installed from the Smart- phone through Google Play (https://play.google.com). This application runs on Android Smart- phones. Similar applications are availale for iphones, ipads and other talets. One of those is the Hindenurg Field Recorder (Version Moile): http://hindenurgsystems.com/products/hindenurg- field- recorder. The sound source As sound source, we used alloons that are capale of emitting an impulse with sustantial sound power when popped y a sharp oject e.g. a needle. The sound power can e adjusted y filling the alloon with more or less air. If the alloon is pumped very hard it can e extremely loud use hearing protectors to prevent hearing damage! For small rooms the impulse created y a alloon might cause overload. In that case a lower level impulse can e created simply y clapping hands. Other stimuli that may e used are popping of a paper ag or the gunshot of a starting pistol. Hard footsteps on floor can also e used for low frequencies. Balloons are usually quite capale of producing high sound power, which can sufficiently cover the middle and high frequency range. Big alloons are etter at the low frequencies (63 and 125 Hz). 3

Using handclaps as the sound source, the power is quite limited. For achieving a satisfactory signal to noise ratio with handclapping the ackground noise should e as low as possile and the room should not e very large. ODEON may not e ale to derive results at all octave ands, ut still measurements at the middle frequency ands are normally not so difficult. Occasionally, a hard footstep can e used to fill the gap for low frequency measurements that cannot e achieved with the previous types of stimuli. Method When the microphone connection and the application have een tested measurements can egin. If you are two persons one can make the recording with the microphone and the other may create the impulse (e.g. popping the alloon). If you are on your own, place the microphone on a tripod (using the tripod adapter for the i436) or, as an alternative option, place the microphone on a stale surface. Settings in the PVD Field Recorder application The type of recording should e set to mono when using the i436 microphone (in fact we did not succeed using the stereo setting). In this case and for all room acoustic measurements in ODEON - a mono type microphone should e used. It is important to have a recording application that provides overload or clipping indication so you get a warning if overload occurs during a recording. If overload exists you may adjust the recording level/input gain. In Pfitzinger Voice Design field recorder the input gain can e controlled y adjusting the Boost value. Another option is to make the next recording using a less pumped alloon (or a softer hand- clap). Even though you are only using one microphone input, different microphone inputs can e chosen from the In: list (MicA to MicE). For the Smart- phone used in this application note MicB gave the est results (we tried the MicA setting too ut it gave overload at very low sound pressure levels). It is recommended to experiment using the different microphone inputs, ut always make sure that the selected microphone is the external one there may e multiple internal microphones in some smart phones even if they cannot record in stereo. The Bandpass filter center setting must e off. Export to ODEON Normally a recording application such as the Pfitzinger Voice Design field recorder saves its recordings into.wav files that can e directly used in ODEON using the Load impulse response tool [2]. If the recording application derives a different audio format, the files must e converted to.wav in an external application, efore loading into ODEON. Case study A numer of snap- shot measurements were carried out in the lunch area at Scion DTU in Lyngy, Denmark (figure 3). The lunch area is part of a large coupled space and is separated from the rest of the space y a wooden screen. The lunch area has the approximate dimensions: 21 meters y 7 meters and the height is around 4 meters. 4

Application note Measurements with a Smart Phone Figure 3: Lunch Room at Scion DTU Lyngy, Denmark and our snapshot- recording equipment. We popped four alloons as the excitation stimuli. The distance etween the source (alloon) and the microphone varied from aout 8 meters to 3 meters. All four explosions were recorded at the same.wav file. The measured impulse response as displayed in ODEON is shown in figures 4 and 5. Figure 4 shows the roadand pressure impulse response, while figure 3 shows the same impulse response squared (energy impulse response). Since the sound power emitted y different alloons is not stale and reproducile, the strength of the impulse response cannot e fully controlled[3]. This is why there is not a monotonic ehaviour for the strength of the impulse response while moving closer to the source. ODEON automatically detects the onset time (vertical dashed- pink line) of the response and automatically truncates the response at the noise floor (vertical dashed- red line). The truncation is performed for each and individually (figures 4 and 5). Using the crop function availale in the measuring system (Measured response Crop) we can isolate further the selected impulse response and save it to a new.wav file[4]. In order to crop an impulse response we can just drag a rectangle around the desired area (from left upper corner to right lower corner of the area of interest) then we can press the C shortcut to save the selected time rage as a separate file. (Continues on page 7) 5

Figure 4: A recording containing 4 impulse responses using alloon explosions in the room of Fig. 3. The roadand signal is shown. The distances etween microphone and alloon were 8, 7, 5 and 4 meters, respectively. The impulse responses were recorded in a single.wav file which has duration of approximately 40 seconds. The file was further analysed in ODEON. C :\Odeon12C omined\measurements\pvd\131010-142436.wav Raw decay curve (road and) SPL(dB) -2-4 -6-8 -10-12 -14-16 -18-20 -22-24 -26-28 -30-32 -34-36 -38-40 -42-44 -46-48 -50-52 -54-56 -58-60 E, Measured Noise floor Onset time Truncation time Chair moved accidentally during the recording. -30-25 -20-15 -10-5 0 time (seconds) Odeon 1985-2013 Licensed to: Odeon A/S 5 10 Figure 5: Broadand impulse responses of figure 4 squared. ODEON will automatically isolate the impulse response that gives the highest signal to noise ratio. The onset time is indicated y a vertical pink- dashed line while the truncation time due to noise floor is indicated y a vertical red- dashed line. 6

(Continues from page 5) The selection does not need to e very precise ecause ODEON will re- detect the onset and truncation times. However, the tail should e long enough to allow an estimate of the ackground noise. Figure 6 shows the cropped (isolated) impulse response for the 1000 Hz octave and and figure 7 shows the squared impulse response. The noise floor is clearly visile at the squared impulse response display. C:\Odeon12Comined\Measurements\PVD\131010-142436Cropped.w av Ray Impulse response at 1000Hz p 13 12 cef Omni microphone 11 Onset time 10 9 8 7 6 5 4 3 2 1 0-1 -2-3 -4-5 -6-7 -8-9 -10-11 -12-13 cef Truncation time -0.15-0.1-0.05 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 0.8 time (seconds) Odeon 1985-2013 Licensed to: Odeon A/S Figure 6: Cropped impulse response from Fig. 4, filtered at 1000 Hz. 7

Figure 7: Same impulse response as for Fig. 6, ut squared and displayed in db. The noise floor detected y ODEON is indicated y a horizontal dotted line. Figure 8 shows the energy decay curves for the eight octave ands (63Hz to 8 khz) availale in ODEON. The decay curves are used for the derivation of the room acoustic parameters. C :\Odeon12C omined\measurements\pvd\131010-142436.wav Decay curcves 46 SPL(dB) 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0-2 -4-6 -8-10 -12 T(30)=*.** s at 63Hz T(30)=0.75 s at 125Hz T(30)=0.65 s at 250Hz T(30)=0.68 s at 500Hz T(30)=0.57 s at 1000Hz T(30)=0.51 s at 2000Hz T(30)=0.48 s at 4000Hz T(30)=0.41 s at 8000Hz 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6 time(seconds) Odeon 1985-2013 Licensed to: Odeon A/S Figure 8: Energy decay curves of the eight ands from 63 Hz to 8000 Hz, for the selected cropped impulse response in figures 6 and 7. Room acoustic parameters The Room acoustic parameter list in the ODEON software provides a list of room acoustic parameters calculated from the impulse response (truncated where the decay enters the noise floor). Depending on the edition of ODEON, different parameters are availale. ODEON Auditorium and ODEON Comined editions provide the full set of parameters, which can e modified or extended y the user. Figure 9 shows the default set of room acoustic parameters for the impulse response of figures 6 and 7, as displayed in ODEON Comined edition when the wave file is loaded using the Load impulse response tool. Some parameters may not e correctly derived due to the lack of information. For example SPL does not have a meaningful value ecause the system of the alloon (source) and the microphone (receiver) cannot e calirated and LF 80 is not correct either as there is no figure- 8 microphone involved in the measurement. It is possile to exclude such parameters from eing displayed as part of a result display y unchecking the Measured field in the Room acoustic parameter list. In a similar way other parameters can e selected or deselected for display. 8

Tale 1 shows a collection of room acoustic parameters at 1 khz for the four different positions four different impulse responses (see figure 4). Even using the simple equipment descried in this application note it seems we are ale to capture the sound filed quiet accurately, with all the variations included. Figure 9: Room Acoustic parameters derived from the impulse response shown in Fig.6 and 7. Wherever the * character is displayed the parameter cannot e calculated, due to lack of sufficient dynamic range or due to insufficient length of the impulse response. Parameters 8m distance 7m distance 5m distance 4m distance EDT,1kHz(s) 0.53 0.48 0.36 0.29 T 30,1kHz(s) 0.55 0.55 0.57 0.51 Ts,1kHz(ms) 35 32 26 19 C 80,1kHz(dB) 9.4 10.1 11.9 14.6 Peak/Noise 69.95 65.61 72.42 66.95 Tale 1: Selected room acoustic parameters for the four different receiver positions in the room (figure 4). Warning against overload As already mentioned it is important to e aware of overload when recording impulse responses, so no clipping occurs in the recorded impulse responses. Clipping is est spotted looking at the roadand squared impulse response recording, while octave- and filtered versions of the response may hide the prolem. In 9

figures 10 and 11 an example of a clipped impulse response is shown for the roadand signal. Even though the 1000 Hz and looks OK (figure 10), the measurement cannot e trusted ecause of clipping (figure 11). Conclusion In this application note we presented an alternative room acoustic measuring method that provides fast and effortless documentation of a case during the first visit on site. Nowadays, the acoustic consultant can make use of a smart phone to take pictures of the room and make some audio recordings of impulse responses at the same time, without using heavy and slow to set- up equipment, such as dodecahedron speakers, external amplifiers, cales and portale PCs. A few alloon explosions or some hand clapping are enough to create some impulse responses and record them in audio files. Later, the files can e loaded into ODEON 12 and e processed to derive the ISO 3382 room acoustic parameters of interest. Even if a fully equipped measurement is required in a later stage of the project, the initial assessment of the acoustic prolem with a smart phone can e extremely time efficient, even though the accuracy might not e the est. C :\Odeon12C omined\measurements\pvd\131002-140802cropped.wav Raw decay curve at 1000Hz SPL(dB) 26 24 22 20 18 16 14 12 10 8 6 4 2 0-2 -4-6 -8-10 -12-14 -16-18 -20-22 -24-26 -28-30 -32 E, Measured Noise floor Onset time Truncation time -0.1 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 time (seconds) Odeon 1985-2013 Licensed to: Odeon A/S Figure 10: Same impulse response as in figure 10, ut filtered at the 1000 Hz and. Clipping is not visile in this display, ut still this measurement should e discarded. 10

C :\Odeon12C omined\measurements\pvd\131002-140802cropped.wav Raw decay curve (road and) 0 SPL(dB) -2-4 -6-8 -10-12 -14-16 -18-20 -22-24 -26-28 -30-32 -34-36 -38-40 -42-44 -46-48 -50-52 -54-56 -58 Clipping E, Measured Noise floor Onset time Truncation time -0.1 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 time (seconds) Odeon 1985-2013 Licensed to: Odeon A/S Figure 11: Clipping at the roadand impulse response, due to overload during the recording. References 1. IEC 61672-1, Electroacoustics- Sound Level Meters. 2002-05. 2. C.L. Christensen & G. Koutsouris. ODEON Room Acoustics Software, manual, version 12, Odeon A/S, Denmark 2013 (http://www.odeon.dk/pdf/odeonmanual12.pdf). 3. Claus Lynge Christensen, George Koutsouris and Jens Holger Rindel. The ISO 3382 parameters. Can we measure them? Can we simulate them? International Symposium on Room Acoustics, Toronto, Canada. June 2013 (http://www.odeon.dk/pulications#pap). 4. Claus Lynge Christensen. Impulse Response Measurements, ODEON video tutorials: http://www.odeon.dk/impulse- response- measurements 11