Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.)

Similar documents
ECT Applications. Features

INDUSTRIAL PRESSURE TRANSMITTER

Industrial Pressure Transmitter

Low Pressure NSL Applications. Features

NAT Applications. Features

NAT Applications. Features

DPS Applications. Features

FPT Applications. Features

Pressure transmitter for general industrial applications Model A-10

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

ED701 General Industry Pressure Transmitter

Pressure Transmitter SIL

Pressure transmitter For general industrial applications Model A-10

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Pressure transmitter for general industrial applications Model A-10

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

OEM pressure transmitter For mobile working machines Model MH-3

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

High-quality pressure transmitter For general industrial applications Model S-10

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

U5300 Industrial Pressure Transducer

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Your Global Automation Partner. PT2000 Pressure Transmitter

Electronic Pressure Switch Type MEP

Relative and absolute pressure transmitter type 528

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

Pressure transmitter For general industrial applications Model A-10

Electronic Temperature Transmitters

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

ph or ORP Transmitter

DTM.OCS.S/N - Modbus Level Transmitter

SUNSTAR 传感与控制 TEL: FAX: Relative and absolute pressure transmitter type 528

High-quality pressure transmitter For general industrial applications Model S-20

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Digital flow ELEMENT transmitter for continuous flow measurement

Pressure transmitter AKS 32 and AKS 33

Temposonics. Magnetostrictive Linear Position Sensors. EH Analog Data Sheet

Relative pressure transmitter type 522 for shipbuilding

Features. Picture. Specifications. Pressure Transmitter 4-20mA 2-wire MPG Type: MPGxxxxxxxx for level measurement Order No.: see Table 1 / Page 4

Digital conductivity transmitter

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

INSERTION paddle wheel flowmeter for continuous flow measurement

Temperature sensor with integrated transmitter for maritime applications, MBT 5560

XPC10 High temperature miniature pressure sensor

FLOAT LEVEL SENSOR TFC. Applications. Reference. Features

Miniature resistance thermometer Model TR33, thread-mounted

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

Heavy Duty Pressure Transducers

Digital inductive conductivity transmitter

Materials (other materials see WIKA diaphragm seal program) Model S-10

prosonic T FMU230, FMU231

M5200 Industrial Pressure Transducer

M5200 Industrial Pressure Transducer

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

Electronic temperature switch with display Model TSD-30

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Valve Island with Electronic I/O

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

INLINE flowmeter for continuous flow measurement

Temperature Sensors Types MBT 5250, MBT 5260 and MBT 5252

NOVOSTRICTIVE Transducer up to 4250 mm touchless. Series TH1

Relative and absolute pressure transmitter type 528

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Temposonics. Magnetostrictive Linear Position Sensors. EH IO-Link Data Sheet

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

NOVOTURN Multiturn Sensor non-contacting. Series RSM-2800

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

OEM Relativ- und Absolut-Drucktransmitter OEM Relative and absolut pressure transmitter OEM Transmetteur de pression relative et absolue

Grundfos Direct Sensor

LINEAR POTENTIOMETER. LMI12-SL / LMI12-SE Series. Key-Features:

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T Analog Data Sheet

Datalogger DL.OCS/N/RS485

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Conductivity Transmitter

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

OEM radar transmitter, for aggressive media level measurement

Digital flow transmitter for continuous flow measurement

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

XP5 Miniature pressure sensor

MICROMACHINED SILICON MODULAR PRESSURE SENSOR

Digital flow ELEMENT transmitter for continuous flow measurement

U5700 Submersible Liquid Level Pressure Transducer

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series Flexible MH Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Level switch Nivotemp NT-EL, NT-ELD

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm. Perfect data processing I 7 I

Flush pressure transmitter For viscous and solids-containing media Model S-11

INLINE flowmeter for continuous flow measurement

Phone: Fax: Web: -

Transcription:

ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economic transmitter ECT 87 is based on the tried and true ECT line of transmitters with the wide media temperature range from - to C. The enhanced accuracy and the low ranges down to 00 mbar in combination with a comprehensive set of of features, materials and options makes the ECT 87 transmitter an ideal and versatile solution suitable for a wide variety of applications. Applications Machine tools Hydraulics Water treatment Features Measuring ranges from 00 mbar Excellent media compatibility Relative or absolute measurement Titanium version optional Frontal membrane optional Data sheet H76aa 0/09 Technical Data Measuring principle Thick-film-on-ceramic Accuracy @ C typ. ± 0. % FS typ. (± 0. % FS typ., ± % FS typ.) Measuring range 0... 0. to 0... 0 bar 0.... to 0... 00 psi Media temperature - C... + C Output signal... 0 ma, 0... VDC,... 6 VDC, 0... 0 VDC, 0..... VDC ratiom. Ambient temperature - C... + C Cable PVC : - C... +60 C Cable PUR : -0 C... +70 C Cable Raychem 08: -0 C... +00 C Subject to change Trafag sensors & controls Switzerland Industriestrasse 8608 Bubikon Tel. + 9 Fax + 9 www.trafag.com trafag@trafag.com

ECT 87 Ordering information/type code Measuring range ) Sensor Pressure connection Electrical connection Output signal Pressure measurement range Over Burst 0... 0.. 66 0... 0.6. 67 0... 0.. 68 0... 0.. 69 0... 0.6. 70 0....0 7 0....6..8 7 0.... 7. 7 0... 8 76 0... 6 77 0... 0 0 78 0... 6 0 79 0... 0 7 80 0... 0 80 00 8 Relative, Material connection and housing:.0 (AISI0) Relative, Material connection and housing:.0/. (AISI6L) ) 6 Relative, Material connection and housing:.6 (AISI8LN) ) 0 Relative, titanium grade ) Pressure measurement range [psi] Over [psi] Burst [psi] 0.... 0 F6 0... 0 F7 0.... 0 F8 0... 0 F9 0... 7. 0 G0 0... 0 G 0... 0 0 60 G 0... 0 60 90 G 0... 0 00 0 G6 0... 00 00 0 G7 0... 0 00 7 G8 0... 0 00 6 G9 0... 00 800 00 H0 0... 00 000 0 H Absolute, Material connection and housing:.0 (AISI0) ) ) 8 Absolute, Material connection and housing:.0/. (AISI6L) ) ) 86 Absolute, Material connection and housing:.6 (AISI8LN) ) ) 80 Absolute, titanium grade ) ) 8 87. XX XX XX XX XX XX G/" female ) 0 G/" male 7 G/" male DIN8-A ) G/" male DIN8-E ) /" NPT male, ANSI B.0. ) 0 /8" NPT male, ANSI B.0. ) 0) 7/6"-0UNF male SAE (J96) ) R/" male, DIN88 ) 9 G/" frontal membrane ) ) Male electrical plug EN 70-80-A (DIN60-A), Mat. PA 0 Male electrical plug Mx, -pole, Mat. PA (Old shape), Mat. PBT (New shape) Male electrical plug industrial standard (contact distance 9. mm), Mat. PBT 0 Male electrical plug Packard Metri Pack, Mat. PBT Cable PUR (Screwed cable gland PA 6-), -0 C +70 C ) 6) Cable PVC (Screwed cable gland PA 6-), - C +60 C ) 6) 9) Cable Raychem (Screwed cable gland PA 6-), -0 C +00 C ) 6) 9) 08 Signal output Load resistance I (supply) U (supply)... 0 ma (Usupply-9 V) / 0 ma 9... 0 VDC 9 0... VDC. kω 0 ma 0... 0 VDC... 6 VDC.0 kω 0 ma 0... 0 VDC 6 0... 0 VDC.0 kω 0 ma... 0 VDC 7 0..... VDC.0 kω 0 ma VDC ± 0. VDC ratiom. H76aa page /8

ECT 87 87. XX XX XX XX XX XX Accessories Seal FKM (-0 C... + C) 6 Seal CR 00 bar (- C... +00 C) 7) 6 Seal EPDM (- C... + C) 6 Pressure peak damping element ø.0 mm, material.0 8) 0 Pressure peak damping element ø 0. mm, material.0 (sensors, 8) resp..0 (sensors 0,, 6, 80, 8, 86) 8) Female electrical connector EN 70-80-A (DIN60-A)/NBR, -0 C... +90 C 8 Female electrical connector EN 70-80-A (DIN60-A)/Silicone, -0 C... + C 6 Female electrical plug Mx, -pole Female electrical connector industrial standard Special electrical connection: Pin +, Pin - (only for output signal... 0 ma and male electrical plug EN70-80-A / DIN60-A) 9 Special electrical connection: Pin Out, Pin -, Pin + (only for output, 6, 7, and male electrical plug EN70-80-A / DIN60-A) 98 Special electrical connection: Pin +, Pin -, Pin Out (only for output signals, 6, 7, and male electrical plug EN 70-80-A / DIN 60-A) 97 Special electrical connection: Pin +, Pin - (only for output... 0 ma and male electrical plug Packard Metri Pack -poles) E Special electrical connection: Pin +, Pin Out, Pin - (only for output signals, 6, 7, and male electrical plug Packard Metri Pack -poles) 99 Special electrical connection: Pin +, Pin -, Pin Ground (only for output signal... 0 ma and male electrical plug, Mx, -pole) 9 Special electrical connection: Pin Out, Pin -, Pin +, Pin Ground (only for output signals, 6, 7, and male electrical plug 0, industrial standard) E Cable length. m M Cable length.0 m M Cable length.0 m M Housing nut for electrical connection EN70-80-A (DIN60-A) secured with Loctite (max. 8 C) L9 Multiple packaging ) VM ) Extended over as well as customized ranges upon request ) Upon request ) Only for ranges: 00 mbar or psi ) Not for sensors and 8, only for ranges bar or 00 psi ) Cable length see accessories (max. length 0 m, in -meter sections) 6) Protection IP68: Immersion depth max. m, Media +0 C + C 7) Only for connections 0, 0,,, 8,, 9 8) Not for connections 0, 9) Pressure ranges > 6 bar (Pressure ranges 6 bar upon request) 0) Only for sensors 6 and 86 and electrical connections 0,, (others on request) ) The order quantity must be a multiple of 0, only for electrical connections 0 and Ni Identical construction for refrigeration: Data sheet No. H7 H76aa page /8

ECT 87 Standard products (extra short lead time) Product Type Code No. Pressure range Over max. Pressure connection Signal output Accuracy @ C typ. [%] ECT0.A 87 66 7 0 0000 0000 9 8 6 0... 0.. G/" male... 0 ma.0 ECT0.6A 87 67 7 0 0000 0000 9 8 6 0... 0.6. G/" male... 0 ma.0 ECT0.A 87 68 7 0 0000 0000 9 8 6 0... 0.. G/" male... 0 ma 0. ECT0.A 87 69 7 0 0000 0000 9 8 6 0... 0.. G/" male... 0 ma 0. ECT0.6A 87 70 7 0 0000 0000 9 8 6 0... 0.6. G/" male... 0 ma 0. ECT0.V 87 66 7 0 0000 0000 7 8 6 0... 0.. G/" male 0... 0 VDC.0 ECT0.6V 87 67 7 0 0000 0000 7 8 6 0... 0.6. G/" male 0... 0 VDC.0 ECT0.V 87 68 7 0 0000 0000 7 8 6 0... 0.. G/" male 0... 0 VDC 0. ECT0.V 87 69 7 0 0000 0000 7 8 6 0... 0.. G/" male 0... 0 VDC 0. ECT0.6V 87 70 7 0 0000 0000 7 8 6 0... 0.6. G/" male 0... 0 VDC 0. ECTF0.A 87 66 6 0 0000 0000 9 8 6 0... 0.. G/" frontal membrane... 0 ma.0 ECTF0.6A 87 67 6 0 0000 0000 9 8 6 0... 0.6. G/" frontal membrane... 0 ma.0 ECTF0.A 87 68 6 0 0000 0000 9 8 6 0... 0.. G/" frontal membrane... 0 ma 0. ECTF0.A 87 69 6 0 0000 0000 9 8 6 0... 0.. G/" frontal membrane... 0 ma 0. ECTF0.6A 87 70 6 0 0000 0000 9 8 6 0... 0.6. G/" frontal membrane... 0 ma 0. ECTF.0A 87 7 6 0 0000 0000 9 8 6 0... G/" frontal membrane... 0 ma 0. ECTF.6A 87 7 6 0 0000 0000 9 8 6 0....6. G/" frontal membrane... 0 ma 0. ECTF.A 87 7 6 0 0000 0000 9 8 6 0.... G/" frontal membrane... 0 ma 0. ECTF.0A 87 76 6 0 0000 0000 9 8 6 0... 8 G/" frontal membrane... 0 ma 0. ECTF6.0A 87 77 6 0 0000 0000 9 8 6 0... 6 G/" frontal membrane... 0 ma 0. ECTF0.0A 87 78 6 0 0000 0000 9 8 6 0... 0 0 G/" frontal membrane... 0 ma 0. H76aa page /8

ECT 87 Specifications Electrical Data Output / supply voltage... 0 ma: (9... 0) VDC 0... VDC: (0... 0) VDC... 6 VDC: (0... 0) VDC 0... 0 VDC: (... 0) VDC 0..... VDC: VDC ratiom. Rise time Typ. ms / 0... 90 % nominal Switch-on-delay Max.. s Inverse-polarity protection, short-circuit strength @ C during min. Environmental conditions Media temperature - C... + C...0 ma: to U s = 0 VDC 0...0 VDC, 0... VDC,...6 VDC: to U s = 0 VDC 0... VDC ratiometric: to U s =. VDC Ambient temperature Protection ) Humidity Vibration Shock - C... + C Cable PVC : - C... +60 C Cable PUR : -0 C... +70 C Cable Raychem 08: -0 C... +00 C IP6, IP67, IP68 Max. 9 % relative g (0...000 Hz) 0 g / 8 ms EMC Protection Emission EN/IEC 6000-6- Immunity EN/IEC 6000-6- Mechanical Data Sensor (wetted parts) Ceramic, Al O (96 %) Pressure connection (wetted parts) Housing Sealing Male electrical plug Weight Mounting torque /8:.0 (AISI0) 6/86:.0/. (AISI6L) 0/80:.6 (AISI8LN) /8: Titanium Grade /8:.0 (AISI0) 6/86:.0/. (AISI6L) 0/80:.6 (AISI8LN) /8: Titanium Grade FKM 70 Sh, CR, EPDM See ordering information ~ 0 g... 0 Nm ) See electrical connection Accuracy Pressure measuring range [psi] > 0... 0. > 0... 0... 0. 0... 0. 0.... 0... 0... 0. 0... 0.6 0.... 0... TEB @ -... +8 C [% FS typ.] ±.0 ±.0 ±.0 Accuracy @ + C [% FS typ.] ± 0. ± 0. ±.0 NLH @ + C (BSL) [% FS typ.] ± 0. ± 0. ± 0. TC zero point and span [% FS/K typ.] ± 0.0 ± 0.0 ± 0.0 Long term stability year @ + C [% FS typ.] ± 0. ± 0. ± 0. H76aa page /8

Measuring accuracy.0 % Measuring accuracy 0. % ECT 87 Accuracy (%) 7 6 0 - - - - - -6-7 -0-0 -0-0 0 0 0 0 0 0 60 70 80 90 00 max. typ. TEB (-...+8) Temp. ( C) Measuring accuracy 0. % Accuracy (%) 7 6 0 - - - - - -6-7 -0-0 -0-0 0 0 0 0 0 0 60 70 80 90 00 max. typ. TEB (-...+8) Temp. ( C) Accuracy (%) 0 - - - - -0-0 -0-0 -0 0 0 0 0 0 0 60 70 80 90 00 max. typ. TEB (-...+8) Temp. ( C) Electrical connection Protection / electrical connection IP6* ) IP67* ) IP67* ) IP6 IP68 max. m Industrial standard EN70-80A ** ) 0 Mx ** ) -pole Packard Metri Pack ** ) -pole Industrial standard Contact distance 9. mm ** ) 0 Cable** ) / IP68 max. m Cable ** ) 08 Standard 9 Standard 9 E Output signal P -0mA I 87.xx.xxxx.xx.9 P U Us (pos. Supply) Us (neg. Supply) Earth (housing) Shield*** ) for DC Supply Output Common Earth (housing) Shield *** ) <e> <e> Standard 98 97 e e e 99 <e> E e e white brown yellow white green brown yellow red black green red white black green 87.xx.xxxx.xx./6/7/ * ) Provided female connector is mounted according to instructions ** ) Ventilation via male electric plug/cable end *** ) Only cable versions or female electrical plug with shield connection Additional information Documents Data sheet www.trafag.com/h76 Instructions www.trafag.com/h7 Flyer www.trafag.com/h7066 H76aa page 6/8

ECT 87 Dimensions 6 8 with male thread 8. 0. with female thread 0. Ø Ø 9.0 87.XX.XXXX.0.XX.XX 87.XX.XXXX..XX.XX 87.XX.X77..XX.XX 87.XX.X9..XX.XX 9... Ø 9.0 87.XX.XXXX..XX.XX 87.XX.X77..XX.XX 87.XX.X9..XX.XX 9 8.. 8. Ø 9.0 87.XX.XXXX.0.XX.XX 87.XX.X77.0.XX.XX 87.XX.X9.0.XX.XX 6 8 with male thread 8. 0. with female thread. customer spec. length 87.XX.XXXX.//08/68.XX.XX Ø /Ø. Ø.8 - Ø 6. H76aa page 7/8

Dimensions ECT 87. () 8 (8.). Ø G/. Ø.0xU G/" Seal DIN869 Ø9. G/" DIN8-A ø9. M x7 G/" DIN8-E Seal DIN869 87.XX.XX0.XX.XX.XX 87.XX.XX7.XX.XX.XX 87.XX.XX.XX.XX.XX 87.XX.XX.XX.XX.XX 7. 0 6.7 9. 0 / -8 NPT ANSI B.0. ø9. /8-8 NPT ANSI B.0. ø9. 7/6"-0UNF SAE (J96) R/" DIN88 87.XX.XX0.XX.XX.XX 87.XX.X6.XX.XX.XX 87.XX.XX.XX.XX.XX 87.XX.XX9.XX.XX.XX Bore M :..7 6 - with male thread G/" Ra.6 Ø H8 87.XX.XX.XX.XX.XX 0 R 6 G/" G/" ~Ø 0. O-Ring Ø0x. Sealing DIN/ISO 869.9x9.x. Ø 9 SW6 Ø Ø Ø 0 Welding flange for G/" frontal membrane (.0) Ordering No. C780 6. 7 0. 8.... 60.8. ~Ø0 max. mm 6 M ) M ) M ) Tightening torque 0...60 Ncm ) Tightening torque 0...60 Ncm 7 87.XX.XXXX.XX.XX.6 87.XX.XXXX.XX.XX.8 87.XX.XXXX.XX.XX. 87.XX.XXXX.XX.XX. H76aa page 8/8