Product Requirements Document: Automated Cosmetic Inspection Machine Optimax

Similar documents
Software Assisted Scratch Visibility Measurements. The SavvyInspector TM

April, 2013 Revision 2.0 Dave Aikens

Understanding Optical Specifications

Devices & Services Company

Exercise 8: Interference and diffraction

Practical Guide to Specifying Optical Components

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

ECEN 4606, UNDERGRADUATE OPTICS LAB

Automatic inspection for surface imperfections: requirements, potentials and limits

Low-Cost Single Mirror Telescope Product Requirements Document Team Z-Telescope

Exam 3--PHYS 102--S10

BEAM HALO OBSERVATION BY CORONAGRAPH

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

Quality assurance. OEM Custom Services. comaroptics.com

Image Formation. Light from distant things. Geometrical optics. Pinhole camera. Chapter 36

Aberrations of a lens

Some of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design)

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

Spotlight 150 and 200 FT-IR Microscopy Systems

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Mechanical Engineering Department. 2.71/2.710 Final Exam. May 21, Duration: 3 hours (9 am-12 noon)

INTERFEROMETER VI-direct

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

Using Stock Optics. ECE 5616 Curtis

Burton's Microbiology for the Health Sciences

Fein. High Sensitivity Microscope Camera with Advanced Software 3DCxM20-20 Megapixels

The End of Thresholds: Subwavelength Optical Linewidth Measurement Using the Flux-Area Technique

flexible lighting technology

Developing a more useful surface quality metric for laser optics

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

Practice Problems for Chapter 25-26

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Microscopy. The dichroic mirror is an important component of the fluorescent scope: it reflects blue light while transmitting green light.

Applications of Optics

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

ECEN 4606, UNDERGRADUATE OPTICS LAB

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH

Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera

Alex Lyubarsky OPTI 521 December 8, 2013

nanovea.com PROFILOMETERS 3D Non Contact Metrology

Optical design of a high resolution vision lens

Mirrors. Plano and Spherical. Mirrors. Published on II-VI Infrared

WITec Alpha 300R Quick Operation Summary October 2018

PROCEEDINGS OF SPIE. Automated asphere centration testing with AspheroCheck UP

Figure 3.4 Approximate size of various types of cells. ~10 um. Red Blood Cells = mm 1500 um. Width of penny Pearson Education, Inc.

OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop

Submersible Microscope User Guide

ADVANCED OPTICS LAB -ECEN Basic Skills Lab

The Importance of Wavelengths on Optical Designs

Beamsplitter Product Specification

LENSES. INEL 6088 Computer Vision

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

The old adage seeing is believing is appropriate when

This experiment is under development and thus we appreciate any and all comments as we design an interesting and achievable set of goals.

Make Machine Vision Lighting Work for You

IMPROVING AUTOMOTIVE INSPECTION WITH LIGHT & COLOR MEASUREMENT SYSTEMS

PHYS 202 OUTLINE FOR PART III LIGHT & OPTICS

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)

Design Description Document

Microscopy: Fundamental Principles and Practical Approaches

Vocabulary: Description: Materials: Objectives: Safety: Two 45-minute class periods (one for background and one for activity) Schedule:

Zeta-300 3D OPTICAL PROFILER

PROCESS SPECIFICATION SURFACE FINISH REQUIREMENTS

Chapter 34 The Wave Nature of Light; Interference. Copyright 2009 Pearson Education, Inc.

Laser Speckle Reducer LSR-3000 Series

Section 5 ISO Drawings ISO 10110

Phys 531 Lecture 9 30 September 2004 Ray Optics II. + 1 s i. = 1 f

EXC500p-- PATHOLOGY MICROSCOPE. EXC500hd -- HD DIGITAL PATHOLOGY MICROSCOPE. EXC500r -- RESEARCH MICROSCOPE EXC500-LABORATORY SCOPE

Motorized Axio Observer Start-up instructions

NAME SECTION PERFORMANCE TASK # 3. Part I. Qualitative Relationships

Vol. Validation of FTIR Systems AIM-9000 Infrared Microscope Infrared Microscope. Convenience of a Wide-View Camera

Physics 102 Exam 3 Fall Last Name: First Name Network-ID

R.B.V.R.R. WOMEN S COLLEGE (AUTONOMOUS) Narayanaguda, Hyderabad.

PICO MASTER 200. UV direct laser writer for maskless lithography

1 Detection of Latent Fingerprints. 2 The Latentmaster System. 3 The Latentmaster Software. 4 Latentmaster Components

Optical Precision. Optimal Outcome.

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 1: THE LIGHT MICROSCOPE

Bandpass Edge Dichroic Notch & More

OptiSpheric IOL. Integrated Optical Testing of Intraocular Lenses

BIG PIXELS VS. SMALL PIXELS THE OPTICAL BOTTLENECK. Gregory Hollows Edmund Optics

Radial Polarization Converter With LC Driver USER MANUAL

Assembly and Experimental Characterization of Fiber Collimators for Low Loss Coupling

Detailed Scientific Barrier Filter Discussion

Correlation of Wafer Backside Defects to Photolithography Hot Spots Using Advanced Macro Inspection

A LEADER IN OPTICAL TECHNOLOGY. GRADIUM Lenses.

COURSE NAME: PHOTOGRAPHY AND AUDIO VISUAL PRODUCTION (VOCATIONAL) FOR UNDER GRADUATE (FIRST YEAR)

StarBright XLT Optical Coatings

OPTIV CLASSIC 321 GL TECHNICAL DATA


Tolerances. WikiOptics. WikiOptics

ASM Webinar Digital Microscopy for Materials Science

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

MICROSCOPY MICROSCOPE TERMINOLOGY

KNIFE-EDGE RIGHT-ANGLE PRISM MIRRORS

Improving the Collection Efficiency of Raman Scattering

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

CHARA AO Calibration Process

Lens Design I. Lecture 5: Advanced handling I Herbert Gross. Summer term

Characterization Microscope Nikon LV150

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

Transcription:

Product Requirements Document: Automated Cosmetic Inspection Machine Optimax Eric Kwasniewski Aaron Greenbaum Mark Ordway ekwasnie@u.rochester.edu agreenba@u.rochester.edu mordway@u.rochester.edu Customer: Optimax Inc/ Patrick Augino Document Number 00004 Revisions level Date E 12-08-2016

Table of Contents Revision History 2 Vision 2 Team Roles 3 Environment 3 Support 3 Target Users 3 Regulatory Issues 3 Design Schedule 4 Fitness for use 4 Preliminary Design Draft #1 6 Preliminary Data 7 Appendix 11 Revision History Revision Description Date A First revision: 10/29/16 Defined the general idea of what our customer wanted our design to do. Mostly entailed the Vision section and the first few bullets of the Fitness for Use section. B Second Revision: 11/13/16 Defined quantitative specifications such as range of test piece diameter. Added Environment, target users C Third Revision: 12/01/16 Added What we are not required to do section D Fourth Revision: 12/14/16 Included preliminary design and preliminary data. Added spring semester design schedule, team roles, revision history, and Appendix F Final Revision: 12/17/16 Added finishing touches and number tweaks.

Vision: Our customer wants a device that can find defects on a polished spherical surface and quantitate them automatically. The device must be able to output in the ISO 10110 standard, where the smallest defect size is 0.7 um. The device cannot be destructive towards the optic, and thus cannot touch the surface in any way. We are responsible for designing the device itself, and the code to process the images and output. Team Roles: Eric Kwasniewski- Aaron Greenbaum- Mark Ordway- Project Coordinator Customer Liaison Scribe Environment: This device will likely be placed somewhere in the testing center at optimax. It is prefered that the optic is not required to be in complete darkness as the testing center will have standard industrial lighting. Temperature and Humidity At room temperature and humidity (22 C and 50% humidity) Will have access to outlet power Will be in shop floor environment, likely to be dust and vibrations Support: Optimax will provide a robotic arm to assist in any translational needs. The robotic arm can carry up to 3000 pounds. The robotic arm is able to move with precision of up to 2 micrometers. Target Users As of now, this device is to be used only by Optimax inspectors. They should be able to easily setup the optical piece and be able to leave the device running by itself. Regulatory Issues: Need to make sure that no patent infringement is made on the SAVVY Optics Inspector. Aside from that no other types of issues. Design Schedule

Month What we will have done December - Complete preliminary design draft - Acquire experimental data on effects of different illumination on surface imperfection - Obtain copy of Chapter 7 of ISO 10110 international standard January - Communicate with our adviser and customer to schedule weekly meetings - Begin programming the detection and analysis software - Come up with prototype designs in CAD February - Design details (pick out components for the prototype) - Begin prototype assembly - Finish up programming of detection software, continue working on analysis software March - Finish up the prototype - Finish up all programing of both detection and analysis software April - Have a working prototype (at least on an optical bench) - Tested data from this system - A planned method of how this system will be mounted

Fitness for Use: The System must meet the required conditions and numerical specifications. Locate defects on a polished spherical Optical surface Quantize said defects according to the ISO 10110 standard Find number and size of defects Do so automatically Do so non-destructively Measure coated and uncoated optics Be able to measure both reflective and transmissive optics. It is prefered that: The system is able to measure the defects in the Mil spec as well as the ISO 10110. The system be able to measure a wide range of radii of curvature (number not specified) The optical system itself be attached to the robotic arm while the optic be in place Numerical Requirements Comments Smallest Measurable Imperfection Test Optic Diameter < 0.7 um 10-300 mm Test Optic R number > 0.75 The R number is the ratio between the radius of curvature and the diameter of the lens Spectrum 400-700 nm The optics will either reflect or transmit at this spectrum Maximum measure time 1 hour What we are not required to do Design the translation mechanism Program the translation mechanism Have the system mount the optic Have the system find sub-surface damage Have the system be able to measure aspherical or freeform optics Preliminary Design Draft #1

Darkfield illumination for increased contrast Darkfield source: possibly a white light ring illuminator. Light from dark field source scatters when it hits a surface imperfection System scans optic and finds location of all defects System images defects and then sends image to computer to quantize defects according to ISO 10110 standard, a completely objective standard. Uses a CCD detector Preliminary Data This data is used to understand the effects of different illumination settings on a surface imperfection in a similar environment to the Optimax environment. Environment At room temperature and humidity (22 C and 50% humidity) Industrial lighting overhead Test piece Uncoated optic, poor surface quality, 1 inch diameter, Convex spherical, unknown material, radius of curvature of 70 mm.

Microscope Opti-tekscope, Model OT-HD 5-30 mm focal distance, 1-300x mag, 1 cm clear aperture. Figure 1: Opti-Tekscope imaging a lens surface. The industrial lighting is present and adding ambient light into the system. Black masking tape is used to absorb light from our improvised light source (Not in picture). Light source The first light source is a brightfield light source that has been integrated into the microscope. A ring of 8 LED lights surrounds the objective piece. The second light source is a dark field light source meant to imitate the source shown in design draft #1. The light source is a cell phone light held at various angles similar to how it is depicted in design draft #1. Data Using this microscope, and test piece, the same spot on the lens was imaged under different lighting conditions at 20x magnification. First with no source, using only the ambient lighting to image. Then using the brightfield source that came with the microscope. Lastly, using a phone to imitate a white light dark field source with the phone being held at different angles. In each image there is a 500um wide scratch and a 1-7 um wide scratch-like imperfection to the left of the 500um wide one.

There are also many small surface imperfections (not dust) scattered across the lens surface. Picture 1: x20 mag picture of lens under Darkfield at 0 degrees. Ambient lighting still present. Picture 2: x20 mag picture of lens under integrated bright field.

Picture 3: Picture of lens with no additional lighting present. Only ambient light. Picture 4: Picture of lens under darkfield lighting with source angled at 30 degrees above the ground. Less contrast of small features.

Picture 5: Picture of lens under darkfield lighting with source at 60 degrees from the ground. The light from the source can be seen at the bottom of the picture. Picture 1 visibly shows the most surface imperfections out of all the other illumination methods. Picture 1 is a dark field source at 0 degrees from the ground. Using a darkfield source at a low angle may be the best approach to finding surface imperfections. One interesting thing to note is the presence of ambient light in picture 1. This is the light from the industrial overhead lighting. Despite its noticeable presence in the image, the surface imperfections are still clearly visible. The background lighting may make it harder to write the program to detect/quantize the imperfections.

Appendix A SavvyInspector TM SIF-4E The SavvyInspectorTM model SIF-4E is the new, high resolution version of our popular SIF-4 software assisted scratch/dig evaluation of flat optical surfaces. Both instruments are designed specifically to reproduce the conditions of an in-reflection visual inspection described in Appendix C of MIL-PRF-13830B, General specification governing the manufacture, assembly, and inspection of optical components for fire control instruments. The factory calibrated inspection head of the SavvyInspector uses invariant illumination and detection optics and proprietary analysis software, allowing objective, repeatable, and recordable evaluation of scratch/dig surface quality. The SIF-4E uses a 1.4 megapixel camera and higher resolution to perform more precise measurements and grading on very small features. It is recommended for micro-optics, and for components that are specified to 20-10 or tighter. Product Description: SavvyInspectorTM SIF-4E is a complete flat-optics inspection system consisting of: 1. A custom LED-based illumination assembly. 2. A detection assembly with a digital megapixel camera. 3. A manual z-stage for focusing to different part thicknesses. 4. A manual, encoded 100 mm x-y stage platform with rails for part holding and positioning. 5. Light baffles, base-stand assembly, and cabling. 6. A stand-alone computer with proprietary SavvyInspectior analysis software. Scratch/Dig Standards Supported MIL-PRF-13830B MIL-C-675C ANSI/OEOSC OP1.002:2009 Visibility Method ISO 10110 general and coating imperfections (but not L-type imperfections) Version 5 Software The SavvyInspectorTM operator interface in the new version 5 software is designed for easy factory-floor operation, while expanding its application in the role of Master Inspector for QA, QC and MRB decisions. The operator enters the inspection level required, and then uses the manual x-y stage to locate the desired defect on the real time viewing

screen. The software reports the scratch grade or dig value automatically. Scratch lengths are measured with the click of the mouse. The always on inspection mode and programmable grade bars allow the operator to get real-time feedback on whether a selected imperfection is acceptable or not with a simple visual interface. There is no subjectivity; the grade is reported and the grade bar turns red if the imperfection is greater than the specification. When a careful review and documentation of a surface is required, the version 5 software provides data management tools to properly collect and file screen shots and inspection grades for each imperfection on a surface, including a summary log in CSV format for easy uploading into Excel or an inspection report. Accumulation rules can be applied using the SavvyAccumulator spreadsheet. Custom calibration files can be created for specific project or customer needs by the Quality Engineer as needed. The calibration data can then be saved and accessed from the inspection mode. Appendix B Angular Spectrum Visibility of surface imperfections (SI) is dependant on the viewing angle, wavelength of source, and width of the surface imperfection.