Nailed Structural-Use Panel and Lumber Beams

Similar documents
THE ENGINEERED WOOD ASSOCIATION

APA Performance Rated Rim Boards

Glulam Connection Details

Introduction. to Wall Bracing

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA

LP SolidStart Laminated Strand Lumber and Laminated Veneer Lumber Louisiana-Pacific Corporation Revised May 6, 2011

Building for High Wind Resistance in Light-Frame Wood Construction

LP SolidStart Laminated Strand Lumber (LSL) and Laminated Veneer Lumber (LVL) Louisiana-Pacific Corporation Revised July 21, 2017

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year.

LP SolidStart Laminated Strand Lumber and Laminated Veneer Lumber Louisiana-Pacific Corporation Revised May 6, 2018

ROOF-CEILING CONSTRUCTION

Joint Evaluation Report

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS

PART II ENGINEERED BASIS OF RIDGE AND EAVE VENT DETAILS

Featuring TJ Rim Board and TimberStrand LSL

MAT105: Floor Framing

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs

ROOF-CEILING CONSTRUCTION

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

Sections & Details. WOOD SILL and FLOOR CONSTRUCTION NOTES

ROOF-CEILING CONSTRUCTION

ROOF-CEILING CONSTRUCTION

VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA

Product Information & Installation Instructions

Re-Roofing Policy SPECIAL REQUIREMENTS AND NOTES

A. Rough carpentry includes but is not limited to the following:

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

LP SolidStart LSL. LP SolidStart LSL Prescriptive Roof Framing Technical Guide 2500F b-1.75e, 2360F b -1.55E and 1730F b -1.

SECTION ROUGH CARPENTRY

ROOF-CEILING CONSTRUCTION

T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY

Structural Criteria for Residential Rooftop Solar Energy Installations

1.03 QUALITY ASSURANCE A. Inspection Agencies: 1. SPIB: Southern Pine Inspection Bureau; for all structural framing of roof joists and headers.

nineteen Wood Construction 1 and design APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS FALL 2016 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

Sections & Details VOCABULARY

Structural Criteria for Residential Rooftop Solar Energy Installations

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

VERSA-LAM. An Introduction to VERSA-LAM Products

Structural Criteria for Residential Flush-Mounted Solar Arrays

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016

Trusted ICC ES PASLODE, Evaluation. report, or as to any. ICC-ES Evaluation

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

Forming and Shoring Product Selector

TYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:

Exterior Wall Fastener Schedule

3.1 General Provisions

Floor Squeaks: Causes, Solutions and Prevention

ESR-2913* Reissued August 1, 2011 This report is subject to renewal August 1, 2013.

installation Guide What you don t Safety I-Joist Storage and Handling United states Installation Instructions for Residential Floor Systems


UL Construction No. 254

REINFORCEMENT DESIGN FOR METAL BUILDING SYSTEMS

PV System Structural Criteria

ICBO ES ER-5598 n HUD MR 1310 DSA PA-123 n LAC RR25448 n CCMC R. Limit States Design

Ash Brook Golf Course Scotch Plains, New Jersey

ForceField Air & Water Barrier System. installation instructions

Overdriven Nails in Structural Sheathings. Overview Revised 3/22/2017

A. Product Data: For each type of process and factory-fabricated product indicated.

DIVISION 6 WOOD AND PLASTICS

REPORT HOLDER: JAACO CORPORATION NORTHEAST 68 TH STREET, SUITE C-130 REDMOND, WASHINGTON EVALUATION SUBJECT:

Carpentry Canadian 3rd Edition Vogt TEST BANK Full download at:

Description. Lesson Outcomes. Assumptions. Build a Floor. Carpenter

Wood Connections. Presented by: Karyn Beebe, P.E.

SECTION CARPENTRY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

Connection Design Examples

Load Tables, Technical Data and Installation Instructions

Chapter 33: Lofts (Or Second Floors)

Expressed Hardwood Structures

SDWH TIMBER-HEX Screw

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER SECTION: LAMINATED STRAND LUMBER REPORT HOLDER:

Unit 9. Wall and Ceiling Framing

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: IKO INDUSTRIES LIMITED

SECTION ROUGH CARPENTRY

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

Hurricane Shutter Designs Refer to Form No. T460 for design considerations for Florida

Residential I-Joist & LVL INSTALLATION GUIDE

Wall Form Design Part I

Field Notching and Drilling of Glued Laminated Timber Beams

eb^sv=qfj_bo UNIVERSITY OF WISCONSIN - STOUT COLLEGE OF SCIENCE TECHNOLOGY ENGINEERING & MATHEMATICS Architectural Technology AEC 233

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Garage Design Guide. October 2018

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

Unit 2 Engineered Panels

Fine Homebuilding. Cottage Shed Plans

Wall bracing is one of the most important structural elements of

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER:

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

Wood structures Copyright G G Schierle, press Esc to end, for next, for previous slide 1

Connection Philosophy. p NDS Chapter-by-chapter description Changes from previous editions Examples. Part 1: Member Design Webinar.

4) Verify that the size of the supporting member can accommodate the connector s specified fasteners.

STRUCTURAL TIMBER DESIGN

Transcription:

D A T A F I L E Nailed Structural-Use Panel and Lumber Beams When roof load or span requirements are too great to allow use of commonly available dimension lumber or timbers, a box beam constructed of lumber and APA trademarked structural-use panels can solve the problem. It offers an inexpensive alternative to steel or glued laminated wood beams. Nailed structural-use panel and lumber beams have many other advantages, too. Among them are: Stiffness and strength Light weight No shrinkage, warping, or twisting Ease of fabrication Materials availability Speedy, easy installation Easily insulated, where necessary Parts of a box beam are shown in the diagram. The lumber flanges carry most of the bending stresses and the structural panel webs transmit the shear stresses. Vertical stiffeners between the flanges act as shear splices at panel butt joints, distribute concentrated loads and end reactions, and resist web buckling. The fasteners transfer the stresses between the lumber and panel parts. BASIC COMPONENTS Upper flange Panel joint Panel web Stiffener End stiffener Panel web Panel joint Lower flange A P A The Engineered Wood Association

1999 APA THE ENGINEERED WOOD ASSOCIATION ALL RIGHTS RESERVED. ANY COPYING, MODIFICATION, DISTRIBUTION OR OTHER USE OF THIS PUBLICATION OTHER THAN AS EXPRESSLY AUTHORIZED BY APA IS PROHIBITED BY THE U.S. COPYRIGHT LAWS. These tables show allowable loading for two typical thicknesses and Span Ratings of structural panels. The Span Rating, a set of two numbers separated by a slash (for example, 32/16), is contained in the APA trademark for structural panel sheathing grades. In the first column of each table, the minimum nominal panel thickness is given first, followed by the Span Rating number. The cross-sections A, B, and C refer to the constructions shown in the sketches. The loads in the tables are given in pounds per linear foot. The lumber and structural panel grades used for calculating the tables are: Lumber: 2 x 4 or 2 x 6 No. 1 Douglas-fir or No. 1 southern pine (unless otherwise noted, reduce allowable loads by 15% for No. 2 Douglas-fir or No. 2 southern pine). ALLOWABLE LOAD (a) FOR 12"-DEEP ROOF BEAM OR HEADER (lb/lin ft) 15/32" 32/16 A 6 8 278* 232* 192 147 116 94 78 64 15/32" 32/16 B 9 12 339* 283* 242* 212 176 143 118 91 23/32" 48/24 B 11 14 408* 340 291 223 176 143 118 95 23/32" 48/24 C 13 17 234 198 160 133 105 ALLOWABLE LOAD (a) FOR 16"-DEEP ROOF BEAM OR HEADER (lb/lin ft) 15/32" 32/16 A 8 10 393* 328* 274 210 166 134 111 93 15/32" 32/16 B 10 13 475* 396* 340* 297 264 219 181 152 23/32" 48/24 B 13 16 569* 474* 406 342 270 219 181 152 23/32" 48/24 C 15 19 295 266 219 184 ALLOWABLE LOAD (a) FOR 20"-DEEP ROOF BEAM OR HEADER (lb/lin ft) 15/32" 32/16 A 9 11 515* 429* 357 273 216 175 144 121 15/32" 32/16 B 12 15 610* 509* 436* 381* 339* 297 246 207 23/32" 48/24 B 15 18 728* 607* 520* 455* 367 297 246 207 23/32" 48/24 C 17 22 385* 346 312 262 ALLOWABLE LOAD (a) FOR 24"-DEEP ROOF BEAM OR HEADER (lb/lin ft) 15/32" 32/16 A 11 13 643* 536* 439 336 266 215 178 149 15/32" 32/16 B 13 16 744* 620* 531* 465* 413 372 312 262 23/32" 48/24 B 16 20 885* 738* 632* 553 465 377 312 262 23/32" 48/24 C 18 24 474* 427 388 342 (a) Includes 15% snow loading increase. *Lumber may be No. 2 Douglas-fir or No. 2 southern pine without reduction of tabulated capacity. 2 Structural Panels: APA RATED SHEATHING Exposure 1, oriented strand board (OSB), composite panels (COM-PLY ), 4- or 5-ply plywood. Three-ply plywood may be used if regraded for core gap restrictions (see item 3 in the Fabrication section). Substitution of higher grades or thicknesses may not result in higher allowable loads, depending upon what limitation controls the design. Also, the calculations assume full-length flange lumber. For this reason, beam length is usually limited to that of available lumber. CROSS SECTIONS A B C

Tables are also based on the following: Deflection: Less than 1/240 of span under total load. Nailing: 8d common 1-1/2" o.c. each flange member (spacing may be doubled in middle half of beam). Design In order to build a box beam that will do the job, you must first determine the load requirements. Here is an example. 1. Figure the load on a beam. Assume that a header using 2 x 4 lumber is to span an 18-foot garage door opening, where the roof is supported by 20-foot-long trusses, including a 1-foot eave on each end. The total roof load consists of 25 psf design snow load (check your local building code) plus 10 psf dead load, which is the weight of the materials in the roof. This total load of 35 psf is carried to the garage-door header and to the back wall of the garage. Thus, the design load on the header is: 35 psf x 20 ft = 350 plf 2 2. Find the appropriate beam design. Look in the 18-foot-span column of the load-span tables and find a beam adequate to support 350 plf plus the weight of the beam. Such a beam is 24 inches deep and consists of two 2 x 4 flange members top and bottom (cross section B), and 15/32" structural panel webs. This beam has an allowable load of 413 plf. The total load on this beam will be 350 plf plus 13 plf, or 363 plf. Fabrication There are just three simple steps in constructing a structural panel-and-lumber box beam. 1. Determine the width of framing lumber necessary to match wall thickness and layout of stiffeners and the panel butt joints. The panel joint locations illustrated in the sketches provide the required minimum 2-foot stagger between panel butt joints on opposite sides of the beam. They also locate all butt joints within the DESIGN EXAMPLE: GARAGE DOOR HEADER Garage door header 20' 1 3

middle half of the beam. This technique allows the stiffeners to act as web shear splices. Vertical stiffeners should be added in the layouts so that they are no farther apart than 4 feet. The 6 inches (0.5 foot) added to the clear spans shown in the load-span tables represent the bearing length of both double end stiffeners. 2. Build the framework of lumber flanges and stiffeners. Dry lumber should be used (not over 19% moisture content). Select full-length flange lumber which is free of warp or characteristics that would produce gaps greater than 1/8" between lumber and structural panel. Lay out stiffeners and flanges accurately in the pattern selected in Step 1. Fasten the flanges to the stiffeners with 8d common nails. Double end stiffeners may be installed between flanges. Frequently, however, it is desirable to extend the end stiffeners through the depth of the beam to allow use of shorter-length flange lumber. On other occasions, it may be desirable to extend the top flange lamination beyond the beam end to tie into the wall framing. 3. Fasten the panel webs to the framework. If 3-ply plywood is to be used, inspect the plywood panels within 15% of each end of the box beam to assure that no core gap exceeds 1/4" width. The flanges should be marked to show location of stiffener centerlines. The panel should be installed with its strength axis in the same direction as the flanges, and with the butt joints occurring over the stiffeners, as determined in Step 1. All beams in the load-span tables function with 8d common nails spaced 1-1/2" on center on each side of each flange lamination. The spacing may be doubled to 3" on center in the middle half of the beam. Use corrosion-resistant nails if the beam is exposed to moisture. If staples, or nails of other sizes or types are used, the spacing must be adjusted in proportion to the allowable lateral load for the fasteners selected. For instance, fasteners allowed half the lateral load of WEB JOINT LAYOUTS 10' to 10-1/2' 1 to 18-1/2' 5' 5' to 5-1/2' 12' to 12-1/2' to 4-1/2' 2'' to 2-1/2' 20' to 20-1/2' 5' to 5-1/2' 7' to 4-1/2' 7' 5' to 5-1/2' 1 to 14-1/2' 22' to 22-1/2' 6' to 4-1/2' to 4-1/2' 6' 16' to 16-1/2' to 4-1/2' 2 to 24-1/2' 6' 1/2' 6' 4

NAILING LAYOUT 1-1/2" Nail spacing* 1/2" Stagger 3" 1/2" Stagger *When end stiffeners extend through the beam, nail spacing is the same as for flanges, except space nails 1 in. on center when double end stiffeners are used in beams with three members per flange (cross-section C). When end stiffeners are inserted between flanges, nails may be spaced 3 inches on center. 8d common nails would be spaced half as far apart. For staples, the closer spacing can be used because there is less tendency to split the lumber. Although the nailing shown is structurally adequate for loads presented in the tables, additional stiffness can be developed by including glue at the interfaces. Any type of available wood adhesive will contribute to performance, but do not use it instead of any of the nails required in the design. APA: the Mark of Quality The trademarks of APA The Engineered Wood Association appear only on products manufactured by APA member mills. The marks signify that the manufacturer is committed to APA s rigorous quality inspection and testing program and that panel quality is subject to verification through APA audit a procedure designed to assure manufacture in conformance with APA performance standards or Voluntary Product Standard PS 1-95 for Construction and Industrial Plywood. Always insist on panels bearing the mark of quality the APA trademark. HEADER ATTACHMENT DETAILS APA THE ENGINEERED WOOD ASSOCIATION Sheathing or siding over; or set beam out thickness of sheathing and butt sheathing to web. RATED SHEATHING 15/32 INCH 32/16 SIZED FOR SPACING EXPOSURE 1 000 PRP-108 16d Nails at 6" o.c. Header (web removed) Wall framing ALTERNATE TOP FLANGE SUPPORT Header 16d Nails at 6" o.c. Wall framing 5

We have field representatives in most major U.S. cities and in Canada who can help answer questions involving APA trademarked products. For additional assistance in specifying APA engineered wood products, get in touch with your nearest APA regional office. Call or write: WESTERN REGION 7011 So. 19th St. P.O. Box 11700 Tacoma, Washington 98411-0700 (253) 565-6600 Fax: (253) 565-7265 EASTERN REGION 2130 Barrett Park Drive, Suite 102 Kennesaw, Georgia 30144-3681 (770) 427-9371 Fax: (770) 423-1703 U.S. HEADQUARTERS AND INTERNATIONAL MARKETING DIVISION 7011 So. 19th St. P.O. Box 11700 Tacoma, Washington 98411-0700 (253) 565-6600 Fax: (253) 565-7265 @ www.apawood.org Web Address: PRODUCT SUPPORT HELP DESK (253) 620-7400 E-mail Address: help@apawood.org (Offices: Antwerp, Belgium; Bournemouth, United Kingdom; Hamburg, Germany; Mexico City, Mexico; Tokyo, Japan.) For Caribbean/Latin America, contact headquarters in Tacoma. The product use recommendations in this publication are based on APA The Engineered Wood Association s continuing programs of laboratory testing, product research, and comprehensive field experience. However, because the Association has no control over quality of workmanship or the conditions under which engineered wood products are used, it cannot accept responsibility for product performance or designs as actually constructed. Because engineered wood product performance requirements vary geographically, consult your local architect, engineer or design professional to assure compliance with code, construction, and performance requirements. Form No. Z416S Revised May 1999/0050 A P A The Engineered Wood Association