a Nexans company Catalogue 2009

Similar documents
a Nexans company Catalogue 2012

a Nexans company Catalogue 2012

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2014

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

Nexans Network Solutions Div. Euromold

Compact catalogue 2014/2015

INSTALLATION INSTRUCTION HEATSHRINK TRIFURCATING TRANSITION JOINT TO SUIT 3 CORE

Medium Voltage Power Cables

Premoulded cable joint SMPGB

QSLVM2500 QSLV-M Cold Shrink Insulator

JCN cables. The. splice is an

END CAP & HEAT SHRINK SLEEVE

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations

Armoured Power and Control Cables Fire Resistant

UNCONTROLLED 3 STANDARD PROCEDURES FOR PREPARING 33KV CABLES

Ritz Instrument Transformers GmbH. Welcome

3M Electrical Markets Division 3M Cold Shrink Silicone Rubber Splices QS-III. Easy Installation. High reliability.

Low Voltage Splices, 1000 V or less

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

Armoured Instrumentation Cables to BS6883

Armoured Power and Control Cables to BS7917

Underground System Design TADP 547

CABLE JOINTING KITS &

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

insulate seal protect EquipmEnt insulation and ConnECtion products

This Certificate consists of 75 pages in total.

SOLDER SLEEVES AIRWORTHINESS BULLETIN. Overview. Repair and Maintenance Techniques for Wiring Systems Date : 29 July 2005.

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

kv: medium voltage reeling cable with fibreoptics

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

Schluter -DITRA-HEAT Repair procedure for the DHE-HK Heating Cable

Energy Division. Bowthorpe LV/MV Surge Arresters

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

A. Product Description: Stranded conductor insulated wire.

Powersafe Termination Guide

Signal converter for electromagnetic flowmeters

Connecting Systems for Cable Repair (Cable Splices)

Low Voltage Splices 0-600V (1000V rated) Cold Shrink Splices (0-1000V)

SRS SEALED ROTARY SENSORS

SECTION MEDIUM-VOLTAGE CABLES

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

Cable connection. 58 RM6 catalogue schneider-electric.com

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

Armoured Power and Control Cables to BS6883

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES... 4

Low Loss Pre-Connectorized Cable Sets, LL58 Series, DC-3.5GHz

MULTIMEDIA & DATA TRANSMISSION

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

HV SYSTEMS. Prysmian HV Systems Product Range 66kV & 132 kv

SKDG Cable Repair Kit Instructions

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

AEE. Canada. Australia

Product Catalogue CABLE CONNECTION TECHNIQUE. Ring Connectors

Company Profile.

Interconnect and Termination Devices

Wiring Repair WIRING REPAIR

NiAc Terminals and Splices

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

MIG/MAG Welding Torch ABIMIG 401 WT / ABIMIG 501 WT liquid-cooled, with divided liner

Data sheet. W-Series WDU 2.5

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

COPPER + LWL RAW CABLES

HYDROFIRM (T) Cables. for use in Ground Water and Drinking Water

CUSTOM DESIGN COAXIAL CABLES BY SICAB

Selection table for flat & ribbon cables

CIR (Crush & Impact Resistant) VFD Power Cable

Signal converter for electromagnetic flowmeters

INSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES

USER'S GUIDE. Vaisala HUMICAP Humidity and Temperature Transmitters HMD70U/Y U303EN11

Mineral-insulated resistance thermometers to EN

3 Splices. Splices. 5700A-MT Trifurcating Accessory Kit pg. 302 MT-C pg. 302 MT-E pg. 302

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

REPORT OF PERFORMANCE TIC

Requirements and Acceptance for Cable and Wire Harness Assemblies

P3-19 Series Connectors For Entertainment Lighting

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS

Handling Precaution for Terminal and Connector

GEXOL WORLD CLASS OIL & GAS CABLES

PEM130ENG 02/08 SJK & SJKK INSTALLATION INSTRUCTION ENGLISH. 1 kv JOINTS FOR 4 TO 4 CORE AND 4 TO 3+1 CORE PLASTIC INSULATED CABLES SJK & SJKK

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

Data sheet C5 RJ45 field plug pro 2P PROFINET

MIL-C-17 Standard RF Coaxial Cable Low Loss & Ultra Low Loss RF Microwave Cable ANTENNA & TEST Cable up to 26.5 GHz

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

Electric cables. Cranes

Data sheet... W-Series WDU 2.5

Data sheet. W-Series WDU 2.5 RT

POTENTIAL TRANSFORMER

One Team, Two Companies, Unique Strength

Thru Wall Floor Seals For New Installation

Hardware Fitting Accessories Door Seals

OPENETICS. P/N E-DAT Industry RJ45 field plug insert Cat.6A. Specialist Manufacturer Voice Data Security.

Transcription:

a Nexans company Catalogue 009

EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: pre-moulded EPDM or silicone rubber connectors, terminations and joints for cables and epoxy bushings for transformers and switch gear, as well as a large range of cold-shrinkable terminations and joints from to kv. Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group. ISO 900 Certificate Since 99, Euromold s commitment to quality is demonstrated by its ISO 900 certification. International standards All our products meet the International standards like CENELEC HD 9, CENELEC EN 80, IEC, IEEE 8 & 0 or country specifications. Official certificates, CESI, KEMA, ATEX prove the conformity of our products. Long duration tests of existing or new products are continuously performed in our test fields. Laboratory accreditation Since June 000, Euromold s independent ELAB laboratory obtained the BELTEST accreditation no.9-t-iso 05 conform with the European standards for laboratories ISO 05 for electrical testing of medium voltage cable accessories according to the International standards IEC and HD 9. While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as standards and technology evolve.

TERMINATIONS Table of contents ITK - indoor termination OTK - outdoor termination AIN - indoor termination AFN - outdoor termination T-ITK - -core indoor termination T-OTK - -core outdoor termination 5TS-NSS - universal bushing boot 0/009

ITK INDOOR TERMINATIONS Application A kit of terminations for use indoors in controlled environmental conditions and subject to light condensation. To connect polymeric insulated cable to equipment. Up to kv /0 () kv.5/ () kv 8./5 (.5) kv /0 () kv./ () kv Design Indoor termination comprising:. Cable lug (not included in the standard kit).. Water sealing mastic.. Silicone tube.. Stress control mastic. 5. Conductive EPDM ring. L Specifications and standards Meets the requirements of CENELEC HD 9.. 5 Termination type Strike distance L Conductor sizes (mm ) ITK ITK ITK ITK 0 0 0 0 5 0 0/009

Kit contents The complete ITK termination kit comprises the following components: The kit also comprises water sealing mastic and installation instructions. = x ITK or ITK termination kit x Factory pre-assembled silicone tubes comprising stress relief and sealing mastic. = x ITK or ITK termination kit x Factory pre-assembled silicone tubes comprising stress relief and sealing mastic. Ordering instructions Select the part number corresponding to both the system voltage and the cable insulation diameter in mm. Example: The copper wire screened cable is kv, mm stranded aluminium. The diameter over core insulation is. mm. Order a x ITK termination kit. Ordering part number x ITK x ITK x ITK x ITK Conductor sizes (mm ) 0 0 mm max 5 0 mm min 0 mm max 0 A All commercialised European standard cable lugs can be used. Cable lugs should be within the dimensions specified (not applicable for ITK and ITK ). For use with copper wire screened cables. No earthing device is necessary. For use with copper tape screened cables. Also order a Kit MT. For use with Alupe or C - cables. For use with three-core cables: see T-ITK. If the cable lug barrel diameter (A) is less than 0 mm: order a rubber adapting sleeve. Can be supplied with all common types of cable lugs. 5

A A A OTK OUTDOOR TERMINATIONS Application A kit of terminations for use outdoors and exposed to prolonged sunshine and other weather conditions. To connect polymeric insulated cable to equipment and for the outdoor terminating on to overhead lines or bus bars. Up to kv /0 () kv.5/ () kv 8./5 (.5) kv /0 () kv./ () kv Design Outdoor termination comprising:. Cable lug (not included in the standard kit).. Water sealing mastic.. Sheds which can be installed upwards or down.. Silicone tube with sheds. 5. Silicone tube.. Stress control mastic.. Conductive EPDM ring. L L Specifications and standards Meets the requirements of CENELEC HD 9.. L 5 5 B B B Fig. Fig. Fig. Termination type Creepage distance A-B Strike distance L Number of sheds Conductor sizes (mm ) Fig. no. OTK OTK OTK OTK 0 890 00 890 0 9 0 5 0 0 0 0/009

Kit contents The complete OTK termination kit comprises the following components: The kit also comprises water sealing mastic and installation instructions. x Factory pre-assembled silicone tubes comprising stress relief and sealing mastic. x OTK termination kit x Factory pre-assembled silicone tubes comprising stress relief and sealing mastic. x Silicone tube with 5 sheds x OTK termination kit x Factory pre-assembled silicone tubes comprising stress relief and sealing mastic. x Silicone tube with sheds x OTK or x OTK termination kit Ordering instructions Select the part number corresponding to both the system voltage and the cable insulation diameter in mm. Example: The copper wire screened cable is kv, mm stranded aluminium. The diameter over core insulation is. mm. Order a x OTK termination kit. Ordering part number x OTK x OTK x OTK x OTK Conductor sizes (mm ) 0 9 0 0 0 All commercialised European standard cable lugs can be used. Cable lugs should be within the dimensions specified (not applicable for OTK and OTK ). For use with copper wire screened cables. No earthing device is necessary. For use with copper tape screened cables. Also order a Kit MT. For use with fabric tape (graphite) screened cables. Order additional semi-conductive tape (type TSC). For use with Alupe or C - cables. For use with three-core cables: see T-OTK. Can be supplied with all common types of cable lugs.

AIN INDOOR TERMINATIONS Application A kit of terminations for use indoors in controlled environmental conditions and subject to light condensation. Provides a simple and quick method of stress relieving on screened polymeric cables. Up to kv /0 () kv.5/ () kv 8./5 (.5) kv /0 () kv./ () kv 8/0 () kv 0.8/ (.5) kv Design Indoor termination comprising:. Cable lug (not included in the standard kit).. High flexibility silicone rubber housing, allowing larger tolerances on cable insulation diameters, with integrated conductive rubber insert, providing stress relief.. Earthing lug (not included in the standard kit). Specifications and standards Meets the requirements of CENELEC HD 9. and IEC 0-. Termination type min Conductor sizes (mm ) max AIN 0 AIN 0 AIN 0 AIN 5 5 0/009 8

Kit contents A kit always comprises termination housings, installation instructions, special lubricant, wiper, adhesive tape, field control mastic,... Cable lugs and earthing lugs are not included in the standard kit, but can be ordered separately. Ordering instructions Select the part number corresponding to both the system voltage and the cable dimensions in mm. Conductor sizes (mm ) 5 95.5 0.8 0 0 9. 8. 0.. 0.0 55.0 Number of sheds L 0 Dia. D 0 Ordering part number x AIN 0--H x AIN 0--H x AIN 0--H x AIN 0--H 5 95 0 0 0 0 8..0. 0.0...5 55.0 5 5 5 0 5 x AIN 0--H x AIN 0--H x AIN 0--H x AIN 0--H 95 0 0 0...5 0.0 8...8 55.0 0 8 x AIN 0--H x AIN 0--H x AIN 0--H x AIN 0--H.5 0.0.8 55.0 0 0 x AIN --H x AIN --H Example: A set of indoor terminations for a kv - 0 mm stranded aluminium cable with copper wire screen without cable lugs. The diameter over is 0. mm. Order a x AIN 0--H termination kit. For use with copper wire screened cables. No earthing device is necessary. For use with copper tape screened cables. Order: -/MT. For use with three-core cables. For use with other cable types. Can be supplied with all common types of cable lugs. No heating or flame is required. 9

AFN OUTDOOR TERMINATIONS Application A kit of terminations for use outdoors and exposed to prolonged sunshine and other weather conditions. To connect polymeric insulated cable to equipment and for the outdoor terminating on to overhead lines or bus bars. Up to kv /0 () kv.5/ () kv 8./5 (.5) kv /0 () kv./ () kv 8/0 () kv 0.8/ (.5) kv Design Outdoor termination comprising:. Cable lug (not included in the standard kit).. Water sealing silicone sleeve.. Silicone housing with sheds and integrated conductive silicone rubber insert providing stress relief for the cable.. Water sealing mastic. 5. Earthing clamp.. Earthing lug (not included in the standard kit). Specifications and standards Meets the requirements of CENELEC HD 9. and IEC 0-. 5 Termination type min Conductor sizes (mm ) max AFN 0 AFN 0 AFN 0 AFN 5 5 0/009 0

Kit contents A kit always comprises termination housings, water sealing sleeve, the installation instructions, special lubricant, wiper, earthing clamp, water sealing mastic, adhesive tape, field control mastic,... Cable lugs and earthing lugs are not included in the standard kit, but can be ordered separately. Ordering instructions Select the part number corresponding to both the system voltage and the cable dimensions in mm. Conductor sizes Number (mm ) of sheds 5 95.5 0.8 L Creepage Dia. D distance 90 9 Ordering part number x AFN 0--H 0 0 0 9.. 8.. 9 05 5 0 x AFN 0--H x AFN 0--H 0.0 55.5 0 9 x AFN 0--H 5 0 8.. 5 00 80 x AFN 0--H 95 0 0.0...5 5 5 8 99 x AFN 0--H x AFN 0--H 0 0.0 55.5 0 9 x AFN 0--H 0. 8. 5 95 x AFN 0--H 95 0 0..5..8 5 9 8 x AFN 0--H x AFN 0--H 0.0 55.0 0 9 x AFN 0--H.5 0.0.8 55.0 0 0 9 9 x AFN --H x AFN --H Example: A set of outdoor terminations for a kv - 0 mm stranded aluminium cable with copper wire screen without cable lugs. The diameter over is 0. mm. Order a x AFN 0--H termination kit. For use with copper wire screened cables. No earthing device is necessary. For use with copper tape screened cables. Order: -/MT. For use with three-core cables. For use with other cable types. Can be supplied with all common types of cable lugs. No heating or flame is required.

T-ITK THREE CORE INDOOR TERMINATIONS Application The T-ITK is a cold-shrinkable indoor termination suited for polymeric insulated threecore cables. It will provide a necessary seal against moisture penetration and a perfect electrical field control. Up to kv /0 () kv.5/ () kv 8./5 (.5) kv /0 () kv./ () kv Design Cold-shrinkable termination comprising:. Cable lugs (not included in the standard kit).. Water sealing mastic.. Silicone rubber tubes.. Stress control mastic. 5. Conductive EPDM ring.. Silicone rubber protection tubes.. Break-out. 8. Flexible tinned copper braid (for use with individual metal tape screened cables). Dia. d 5 Specifications and standards The cold-shrinkable T-ITK termination meets the requirements of CENELEC HD 9.. Dia. D 8 Termination type Dia. d outer sheath Dia. D Conductor sizes (for information only) (mm ) min max T-ITK - 0 8 90 0 T-ITK - 8 0 0 T-ITK - T-ITK - 0 8 8 90 0 5 85 0 0/009

Kit contents The complete cold-shrinkable T-ITK termination kit comprises the following components: The kit also comprises a roll of adhesive tape, flexible copper braid and installation instructions. T-ITK W cold-shrinkable termination kit x Cold-shrinkable termination assembly Water sealing mastic x Cold-shrinkable break-out x Cold-shrinkable protection tube x Pulling hook Ordering instructions Select the part number corresponding to both the system voltage and the cable dimensions in mm. Example: The cable is kv, x mm stranded aluminium, with a diameter of.0 mm over outer sheath and.5 mm over the core insulation. The cable has an individual copper tape screen. Order a T-ITK - termination kit. Ordering part number T-ITK - T-ITK - T-ITK - T-ITK - All commercialised European standard cable lugs can be used. Cable lugs should be within the dimensions specified (not applicable for ITK and ITK ). outer sheath 0 0 8 8 8 8 90 0 90 0 X For use with copper tape screened cables. No further earthing device is necessary. Different armour connections are available. For use with other cable types. For tail lengths X between 0 and 00 mm. Can be supplied with all common types of cable lugs. Also available with heat-shrinkable break-out

T-OTK THREE CORE OUTDOOR TERMINATIONS Application The T-OTK is a cold-shrinkable outdoor termination suited for polymeric insulated threecore cables. It will provide a necessary seal against moisture penetration and a perfect electrical field control. Up to kv /0 () kv.5/ () kv 8./5 (.5) kv /0 () kv./ () kv Design Cold-shrinkable termination comprising:. Cable lugs (not included in the standard kit).. Water sealing mastic.. Silicone rubber tubes with sheds.. Silicone rubber tubes. 5. Stress control mastic.. Conductive EPDM ring.. Silicone rubber protection tubes. 8. Break-out. 9. Flexible tinned copper braid (for use with individual metal tape screened cables). 5 Specifications and standards The cold-shrinkable T-OTK termination meets the requirements of CENELEC HD 9.. 8 9 Termination type Dia. d outer sheath Dia. D Conductor sizes (for information only) (mm ) min max T-OTK - T-OTK - T-OTK - T-OTK - 0 0 0 8 8 8 8 90 0 90 0 0 0 85 0 0/009

Kit contents The complete cold-shrinkable T-OTK termination kit comprises the following components: The kit also comprises a roll of adhesive tape, flexible copper braid and installation instructions. T-OTK T-OTK T-OTK W cold-shrinkable termination kit x Cold-shrinkable termination assembly Water sealing mastic x Cold-shrinkable break-out x Coldshrinkable protection tube x Pulling hook Ordering instructions Select the part number corresponding to both the system voltage and the cable dimensions in mm. Example: The cable is kv, x mm stranded aluminium, with a diameter of.0 mm over outer sheath and.5 mm over the core insulation. The cable has an individual copper tape screen. Order a T-OTK - termination kit. Ordering part number T-OTK - T-OTK - T-OTK - T-OTK - All commercialised European standard cable lugs can be used. Cable lugs should be within the dimensions specified. outer sheath 0 0 0 8 8 8 8 90 0 90 0 X For use with copper tape screened cables. No further earthing device is necessary. Different armour connections are available. For use with other cable types. For tail lengths X between and 8 mm. Can be supplied with all common types of cable lugs. Also available with heat-shrinkable break-out 5

5TS-NSS UNIVERSAL BUSHING BOOT Application This universal bushing boot is manufactured from nontracking EPDM rubber and is designed to mate with all types of cold or heat-shrinkable terminations (without sheds). The bushing part fits interface diameters between 0 and 0 mm. The system is separable and allows easy removal for testing. This boot is suitable for all angles between 90 and 80. Up to.5 kv /0 () kv.5/ () kv 8./5 (.5) kv Kit contents The x 5TS-NSS kit comprises universal bushing boots, silicone grease and installation instructions. 0 Dia. 00 Dia. 00 Dia. 90 Clearances This is an unscreened boot and therefore not save to touch when energised. When used in a metal enclosed cable box, these minimum clearances must be respected. Dia. 90 Dia. 5 0 00 00 5 5 Dia. D Termination In mm Bushing boot type Conductor sizes (mm ) Diameter D over termination 5TS-NSS.5 max 5 0 0 0/009

Additional catalogue information on power cable accessories is available by contacting us at the address below: Distributed by: Nexans Network Solutions N.V. - Div. Euromold Zuid III, Industrielaan, B-90 Erembodegem Tel.: + (0)5 85 0 Fax: + (0)5 8 0 www.nexans.com info.euromold@nexans.com 0/009 Catalogue also available on CD-ROM