ProcessMaster / HygienicMaster

Similar documents
ProcessMaster, HygienicMaster FEX300, FEX500

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter

Electromagnetic Flowmeter ProcessMaster, HygienicMaster FEX300, FEX500

ProcessMaster FEP300 Electromagnetic Flowmeter. The process industry's first choice

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

ProcessMaster FEP500 Electromagnetic Flowmeter. The process industry's first choice. Maximum measuring accuracy Maximum measuring error: 0.

Safety Instructions Proline Promag 500

ProcessMaster FEP300 Electromagnetic flowmeter. The process industry's first choice

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Electro-Magnetic Flowmeters COPA-XE

HygienicMaster FEH500 Electromagnetic Flowmeter. A first-class choice for all hygienic applications

Installation guide 971 SmartRadar LTi

Installation guide 873 SmartRadar Control Unit & Antenna Unit

OPTIWAVE 7300 C Supplementary instructions

Safety Instructions Proline Promass 300

Coriolis Massflowmeter

Coriolis Massflowmeter

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OPTIFLUX 5000 Technical Datasheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

VortexMaster FSV430, FSV450 SwirlMaster FSS430, FSS450 Vortex and Swirl flowmeter

Flow Measurement SITRANS F M

SwirlMaster FSS430, FSS450 Swirl flowmeter

VortexMaster FSV430, FSV450 Vortex flowmeter

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Isolators A3/1.

Resistance thermometer Model TR30, compact design

Proline Promass 40. Safety Instructions. NEPSI Zone 1, Zone 21

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

PROline promag 53 Division 1

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Loop Powered Indicator

Design and applications

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

PRetrans Table of contents

OPTIFLUX 5000 Technical Datasheet

IP26 Series Current to Pneumatic Converter

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Head mounted Temperature Transmitter TF02/TF02-Ex

Rosemount 5408 and 5408:SIS Level Transmitters

WATERFLUX 3000 Quick Start

Safety Instructions Proline Promass 100

Industrial Pressure Transducers

Installation guide 854 XTG Level Gauge

Power supply. Calibration. Surface finishing. Seal. Process connection

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

VortexMaster FSV430, FSV450 SwirlMaster FSS430, FSS450 Vortex and Swirl flowmeter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Field indicator for current loops with HART communication Models DIH50, DIH52

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

Resistance thermometer Model TR30, compact design

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

WATERFLUX 3000 Quick Start

TMU. Coriolis Mass Flow Meter. for liquids and gas

Installation guide 877 FDI Field Display & Interface

Analog Universal Module HART for Zone 2 Series 9468/33

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Compact Orifice Flow Meter

Target disk flowmeter for liquids and gases

LF Conductivity Measuring Probe

INSTRUCTION MANUAL (ATEX / IECEx)

User's Manual Model SE14 Magnetic Flow Converter

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK

Metal Cone Variable Area Flowmeter VA Master FAM540

ATEX Installation Drawings and Instructions

Introduction. Additional Information. Temperature transmitter for HART protocol. Suitable for all standard requirements. Measurement made easy

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

Rosemount 3101, 3102, and 3105

Flow Measurement SITRANS F M

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Positioner with HART Communication Type 3780

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

Intrinsic Safety Control Drawing

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

SET Installation and Operating Instructions. Level switch for two sensors

KFS. Flap-type flow meter. Design and range of application

Attachment to Certificate IECEx PTB X

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

EN-2018 MAGNETIC FLOW METERS

Coriolis Mass Flow Meter Model TM

LST100 Ultrasonic level transmitter for upstream oil and gas

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Miniature resistance thermometer Model TR33, thread-mounted

OPTIWAVE 6300 C Quick Start

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Transcription:

SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster FM / cfm Div. 1, Div. 2 Safety information for electrical equipment for potentially explosive areas in accordance with Factory Mutual Standards and Canadian Standards Association Electromagnetic Flowmeter FEP300/FEH300

Neu Contents Electromagnetic Flowmeter ProcessMaster / HygienicMaster EX Safety Instructions - EN SM/FEP300/FEH300/FM/CSA-EN 07.2009 Rev. B Manufacturer: ABB Automation Products GmbH Dransfelder Straße 2 D-37079 Göttingen Germany Tel.: +49 551 905-534 Fax: +49 551 905-555 CCC-support.deapr@de.abb.com Copyright 2009 by ABB Automation Products GmbH Subject to changes without notice This document is protected by copyright. It assists the user in safe and efficient operation of the device. The contents of this document, whether whole or in part, may not be copied or reproduced without prior approval by the copyright holder.

Contents Important This document forms an integral part of the following manuals: Operating Instruction OI/FEP300/FEH300 Commissioning instruction CI/FEP300/FEH300 1 Safety...4 1.1 Operator liability...4 1.2 Technical limit values...4 1.3 Safety information for electrical installation...4 1.4 Symbols and warnings...5 2 Device designs...6 2.1 Compact design...6 2.1.1 Div. 1...6 2.1.2 Div. 2...7 2.2 Design with external transmitter...8 2.2.1 Div. 1...8 2.2.2 Div.2...9 2.3 Name plate...10 2.3.1 Name plate for compact design...10 2.3.2 Name plate for the remote design...11 2.3.3 Name plate for transmitter...12 3 Mounting...13 3.1 Information about opening and closing the housing...13 3.2 Rotating the transmitter housing...14 3.3 Cable entries...14 3.4 High temperature version...15 3.5 Protection class IP 68...15 3.6 Information about using the device in areas with combustible...15 3.6.1 Maximum Allowable Surface Temperature...15 3.6.2 Minimum signal cable length...15 3.7 Electrical connection...16 4 Ex relevant specifications for operation in Div. 1...17 4.1 Electrical connection...17 4.1.1 Connection diagram for models FEP315, FEH315, FEP325, and FET325 in Div. 1...18 4.1.2 Connection diagram for model FEP325 in Div. 1 and the FET325 transmitter in Div. 2 or FET321 outside the Ex area...19 4.2 Electrical data...20 4.3 Temperature values...21 5 Ex relevant specifications for operation in Div. 2...25 5.1 Electrical connection...25 5.1.1 Connection diagram for models FEP315, FEH315, and FET325 in Div. 2, FET321 outside the Ex area...25 5.2 Electrical data...26 5.3 Temperature values...26 2 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Contents 6 Commissioning...29 6.1 Preliminary checks prior to start-up...29 6.2 Notes on combining the FEP325 flowmeter sensor with the FET325 transmitter...29 6.3 Special features of the device design for operation in Div. 1...30 6.3.1 Configuring the current output...30 6.3.2 Configuration of the digital outputs...30 6.4 Changing the type of protection...31 7 Maintenance...32 7.1 General information...32 7.2 Replacing the transmitter or sensor...33 7.2.1 Transmitter...33 7.2.2 Flowmeter sensor...33 8 Spare parts list...34 8.1 Fuses for transmitter electronics...34 8.2 Spare parts for the compact design...34 8.3 Spare parts for remote design...35 8.3.1 Field-mount housing...35 8.3.2 Round field-mount housing...35 8.3.3 Flowmeter sensor (Zone 2/Div 2)...36 8.3.4 Flowmeter sensor (Zone 1/Div 1)...36 9 Appendix...37 9.1 Installation drawing IDM-10-A0258...37 9.2 Additional documents...39 9.3 Approvals and certifications...39 SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 3

Safety 1 Safety 1.1 Operator liability The operators must strictly observe the applicable national regulations with regards to installation, function tests, repairs, and maintenance of electrical devices (e.g., NEC, CEC). 1.2 Technical limit values Particular attention must be paid to the limit values listed in the sections relating to "ex relevant specifications": The data for the signal inputs and outputs of the transmitter The permissible temperature data and limit values 1.3 Safety information for electrical installation Never attempt electrical connection unless the auxiliary power supply is switched off. Ground the flowmeter sensor and transmitter housing. Make sure there is no risk of explosion. 4 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Safety 1.4 Symbols and warnings DANGER <Serious damage to health / risk to life> This symbol in conjunction with the signal word "Danger" indicates an imminent danger. Failure to observe this safety information will result in death or severe injury. DANGER <Serious damage to health / risk to life> This symbol in conjunction with the signal word "Danger" indicates an imminent electrical hazard. Failure to observe this safety information will result in death or severe injury. WARNING <Bodily injury> This symbol in conjunction with the signal word Warning indicates a possibly dangerous situation. Failure to observe this safety information may result in death or severe injury. WARNING <Bodily injury> This symbol in conjunction with the signal word "Warning" indicates a potential electrical hazard. Failure to observe this safety information may result in death or severe injury. CAUTION <Minor injury> This symbol in conjunction with the signal word Caution indicates a possibly dangerous situation. Failure to observe this safety information may result in minor or moderate injury. This may also be used for property damage warnings. ATTENTION <Property damage>! The symbol indicates a potentially damaging situation. Failure to observe this safety information may result in damage to or destruction of the product and/or other system components. IMPORTANT (NOTICE) This symbol indicates operator tips, particularly useful information, or important information about the product or its further uses. It does not indicate a dangerous or damaging situation. SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 5

Device designs 2 Device designs Devices suitable for use in potentially explosive atmospheres feature the corresponding Ex mark on their name plates. The design intended for use in Div. 1 is identified by the letter "R" in the model number, while the design intended for use in Div. 2 is identified by the letter "P". 2.1 Compact design 2.1.1 Div. 1 The transmitter and the flowmeter sensor form a single mechanical entity. ProcessMaster HygienicMaster Div. 1 Div. 1 FEP315...R... FEH315...R... USA FM approved G00886 G00883 XP: CL I / DIV 1 / GP ABCD XP: CL I/ DIV 1/ GP ABCD NI: CL III / DIV 1 NI: CL III/ DIV 1 DIP: CL II / DIV 1 / GP EFG DIP: CL II/ DIV 1/ GP EFG DN 3-300: CL I, ZN 1 AEx d e ia ma IIC T6 T2 >DN 300: CL I, ZN 1 AEx d e ia IIC T6 T2 DN 3-2000: Zone 21 Ex td iad A21 IP6X T70 C T medium Canada cfm approved USA FM approved CL I, ZN 1 AEx d e ia ma IIC T6 T2 Zone 21 Ex td iad A21 IP6X T70 C T medium Canada cfm approved XP: CL I/ DIV 1/ GP ABCD XP: CL I/ DIV 1/ GP ABCD NI: CL III / DIV 1 DN 3-300: Ex d e ia ma IIC T6 T2 >DN 300 : Ex d e ia IIC T6 T2 NI: CL III/ DIV 1 Ex d e ia ma IIC T6 T2 DIP: CL II / DIV 1 / GP EFG DIP: CL II/ DIV 1/ GP EFG Fig. 1 6 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Device designs 2.1.2 Div. 2 ProcessMaster HygienicMaster Div. 2 Div. 2 FEP315...P... FEH315...P... USA USA FM approved, File 3034391 FM approved, File 3034391 NI: CL I, II / DIV2 / GP ABCDFG / T4 T3 NI: CL I, II / DIV2 / GP ABCDFG / T4 T3 CL III / DIV1, 2 / T4 T3 CL III / DIV1, 2 / T4 T3 CL I ZN2 AEx na nc IIC T4... T3 CL I ZN2 AEx na nc IIC T4... T3 DIP: CL II, III / DIV1 / GP EFG / T 70 C T medium DIP: CL II, III / DIV1 / GP EFG / T 70 C T medium AEx td 21 T70 C... T medium AEx td 21 T70 C... T medium Canada cfm approved, File 3034391C Canada cfm approved, File 3034391C NI: CL I, II / DIV2 / GP ABCDFG / T4 T3 NI: CL I, II / DIV2 / GP ABCDFG / T4 T3 CL III / DIV1, 2 / T4 T3 CL III / DIV1, 2/ T4 T3 CL I ZN2 Ex na nc IIC T4... T3 CL I ZN2 Ex na nc IIC T4... T3 DIP: CL II, III / DIV1 / GP EFG / T70 C T medium DIP: CL II. III / DIV1 / GP EFG / T70 C T medium DIP A21 T A T70 C... T medium DIP A21 TA T70 C... T medium Fig. 2 SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 7

Device designs 2.2 Design with external transmitter 2.2.1 Div. 1 The transmitter is mounted in a separate location from the flowmeter sensor. The electrical connection between the transmitter and flowmeter sensor may only be established using the signal cable supplied. Risk of explosion caused by incorrect transmitter installation The FET321 transmitter is not approved for Ex areas. The FET321 transmitter must not be installed or operated in potentially explosive atmospheres. If the FEP325 flowmeter sensor is combined with the FET321 or FET325 transmitter (Zone 2), the maximum permissible signal cable length is 50 m (164 ft) with a minimum conductivity of 5 µs/cm, without a pre-amplifier. If the FEP325 flowmeter sensor is combined with the FET325 transmitter (Zone 1), 10 m (32.8 ft) signal cables are permanently connected to the transmitter. ProcessMaster flowmeter sensor in Ex area, Div. 1 FEP325...R... USA FM approved XP: CL I / DIV 1 / GP ABCD XP: CL I/ DIV 1/ GP ABCD NI: CL III / DIV 1 DIP: CL II / DIV 1 / GP EFG DN 3-300: CL I, ZN 1 AEx d e ia ma IIC T6 T2 >DN 300: CL I, ZN 1 AEx d e ia IIC T6 T2 DN 3-2000: Zone 21 Ex td iad A21 IP6X T70 C T medium G00862 Canada cfm approved NI: CL III / DIV 1 DN 3-300: Ex d e ia ma IIC T6 T2 >DN 300 : Ex d e ia IIC T6 T2 DIP: CL II / DIV 1 / GP EFG Transmitter in Ex area, Div. 1 in Ex area, Div. 2 Outside the Ex area FET325...R... FET325...P... FET321 G00863 USA USA No Ex approval FM approved FM approved XP: CL I / DIV 1/ GP ABCD NI: CL I, II / DIV2 / GP ABCDFG / T4 IS: CL II/ DIV 1/ GP EFG CL III / DIV1, 2 / T4 CL I, II,III ZN 2 AEx na IIC T4 NI: CL III/ DIV 1 CL I, ZN 1 AEx d e [ia] IIC T6 Zone21 AEx td [iad] A21 IP6X T70 C Canada cfm approved DIP: CL II, III / DIV1 / GP EFG / T70 C Canada cfm approved XP: CL I/ DIV 1/ GP ABCD NI: CL I, II/ DIV 2/ GP ABCDFG/ T4 IS: CL II/ DIV 1/ GP EFG CL III/ DIV 1, 2/ T4 NI: CL III/ DIV 1 Ex d e [ia] IIC T6 Gb Ex na IIC T4 Fig. 3 DIP: CL II, III / DIV1 / GP EFG / T70 C DIP A21 TA 70 C 8 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Device designs 2.2.2 Div.2 Risk of explosion caused by incorrect transmitter installation The FET321 transmitter is not approved for Ex areas. The FET321 transmitter must not be installed or operated in potentially explosive atmospheres. Without a pre-amplifier, the maximum permissible signal cable length is 50 m (164 ft) with a minimum conductivity of 5 µs/cm. With a pre-amplifier, the maximum permissible signal cable length is 200 m (656 ft). Flowmeter sensor ProcessMaster HygienicMaster in Ex area, Div. 2 in Ex area, Div. 2 FEP325...P... FEH325...P... USA USA NI: CL I, II / DIV2 / GP ABCDFG / T4 T3 NI: CL I, II / DIV2 / GP ABCDFG / T6 T3 CL III / DIV1, 2 / T4 T3 CL III / DIV1, 2 / T6 T3 CL I ZN2 AEx na nc IIC T4... T3 CL I ZN2 AEx na IIC T4... T3 DIP: CL II, III / DIV1 / GP EFG / T 70 C T medium DIP: CL II, III / DIV1 / GP EFG / T85 C T medium AEx td 21 T70 C... T medium AEx td 21 T70 C... T medium Canada Canada NI: CL I, II / DIV2 / GP ABCDFG / T4 T3 NI: CL I, II / DIV2 / GP ABCDFG / T6 T3 CL III / DIV1, 2 / T4 T3 CL III / DIV1, 2/ T6 T3 CL I ZN2 Ex na nc IIC T4... T3 CL I ZN2 Ex na IIC T4... T3 DIP: CL II, III / DIV1 / GP EFG / T70 C T medium DIP: CL II, III / DIV1 / GP EFG / T85 C T medium DIP A21 TA T70 C... T medium DIP A21 T A 85 C... T medium Transmitter (The flowmeter sensors illustrated above can be combined with one of the two transmitters described below) in Ex area, Div. 2 FET325...P... Outside the Ex area FET321 NI: DIP: CL I, II / DIV2 / GP ABCDFG / T4 CL III / DIV1, 2 / T4 CL I, II,III ZN 2 AEx na IIC T4 CL II, III / DIV1 / GP EFG / T70 C - No Ex approval! NI: DIP: CL I, II/ DIV 2/ GP ABCDFG/ T4 CL III/ DIV 1, 2/ T4 Ex na IIC T4 CL II, III / DIV1 / GP EFG / T70 C DIP A21 TA 70 C SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 9

Device designs 2.3 Name plate 2.3.1 Name plate for compact design 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Fig. 4: Compact device 1 Model number (for more detailed information about the technical design, refer to the data sheet or the order confirmation) 2 Order no. 3 Meter size and nominal pressure rating 4 Material: Flange/lining/electrode 5 T med = max. permissible fluid temperature T amb = max. permissible ambient temperature 6 Calibration value Qmax DN 7 Calibration value Ss (span) Calibration value Sz (zero point) 8 Communications protocol of transmitter 9 Excitation frequency of sensor coils 10 Software version 11 Year of manufacture 12 CE mark 13 Serial number for identification by the manufacturer 14 Client-specific TAG number (if specified) 15 Protection type according to EN 60529 16 Supplementary information: EE = grounding electrodes, TFE = partial filling electrode Important Meters with 3A approval are labeled with an additional plate. G00629 17 Accuracy to which the unit was calibrated (e.g., 0.2% of rate) 18 Version level (xx.xx.xx) 19 Label indicating whether the unit is subject to the Pressure Equipment Directive (PED). Information on the relevant fluid group. Fluid group 1 = hazardous fluids, liquid, gaseous. (Pressure Equipment Directive = PED). If the pressure equipment is not subject to the Pressure Equipment Directive 97/23/EC, it is classified in accordance with SEP (= sound engineering practice) as per Art. 3 Para. 3 of the PED. If no such information is present, it means that the device does not claim to comply with the requirements of the Pressure Equipment Directive 97/23/EC. Water supplies and connected equipment accessories are classed as an exception in accordance with guideline 1/16 of Art. 1 Para. 3.2 of the Pressure Equipment Directive. 20 Ex mark according to FM (example) 21 Ex mark according to cfm (example) 10 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Device designs 2.3.2 Name plate for the remote design 1 2 3 4 5 6 7 8 9 10 FEP325 11 12 13 14 15 16 17 18 G00630 Fig. 5: Remote design 1 Model number (for more detailed information about the technical design, refer to the data sheet or the order confirmation) 2 Order no. 3 Meter size and nominal pressure rating 4 Material: Flange/lining/electrode 5 Client-specific TAG number (if specified) 6 T med = max. permissible fluid temperature T amb = max. permissible ambient temperature 7 Protection type according to EN 60529 8 Calibration value Qmax DN 9 Calibration value Ss (span) Calibration value Sz (zero point) 10 Year of manufacture 11 CE mark 12 Serial number for identification by the manufacturer 13 Supplementary information: EE = grounding electrodes, TFE = partial filling electrode 14 Accuracy to which the unit was calibrated (e.g., 0.2% of rate) Important Meters with 3A approval are labeled with an additional plate. 15 Excitation frequency of sensor coils 16 Label indicating whether the unit is subject to the Pressure Equipment Directive (PED). Information on the relevant fluid group. Fluid group 1 = hazardous fluids, liquid, gaseous. (Pressure Equipment Directive = PED). If the pressure equipment is not subject to the Pressure Equipment Directive 97/23/EC, it is classified in accordance with SEP (= sound engineering practice) as per Art. 3 Para. 3 of the PED. If no such information is present, it means that the device does not claim to comply with the requirements of the Pressure Equipment Directive 97/23/EC. Water supplies and connected equipment accessories are classed as an exception in accordance with guideline 1/16 of Art. 1 Para. 3.2 of the Pressure Equipment Directive. 17 Ex mark according to FM (example) 18 Ex mark according to cfm (example) SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 11

Device designs 2.3.3 Name plate for transmitter 1 2 3 4 5 6 7 9 10 11 8 Fig. 6: External transmitter, model: FET325 for Div. 1 1 Model number (for more detailed information about the technical design, refer to the data sheet or the order confirmation) 2 Order no. 3 Client-specific TAG number (if specified) 4 T amb = max. permissible ambient temperature 5 Protection type according to EN 60529 6 Supply voltage 7 Communications protocol of transmitter 8 Software version 9 Version level (xx.xx.xx) 10 Ex mark according to FM (example) 11 Ex mark according to cfm (example) G00864 1 2 3 4 5 6 7 9 10 11 8 Fig. 7: External transmitter, model FET325 for Zone 2 1 Model number (for more detailed information about the technical design, refer to the data sheet or the order confirmation) 2 Order no. 3 Client-specific TAG number (if specified) 4 T amb = max. permissible ambient temperature 5 Protection type according to EN 60529 6 Supply voltage 7 Communications protocol of transmitter 8 Software version 9 Version level (xx.xx.xx) 10 Ex mark according to FM (example) 11 Ex mark according to cfm (example) G00632 12 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Mounting 3 Mounting 3.1 Information about opening and closing the housing Risk of explosion! When the housing cover is open, the explosion protection is suspended. Before opening the housing switch off the power to all connection lines and wait at least 20 minutes. Release the cover safety device by screwing in the Allen screw (1). Before closing the housing make sure that the gasket (O-ring) for the housing cover is seated correctly. After closing the housing, lock the housing cover by unscrewing the Allen screw (1) to prevent opening the cover accidentally. Fig. 8 1 1 G00758 SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 13

Mounting 3.2 Rotating the transmitter housing 1 3 2 Fig. 9 3 G00761 1. Loosen the Allen screws (3) on the front and back sides, but do not remove entirely. 2. Loosen screws (2) and rotate the transmitter housing (1) by 90 to the left or right. 3. Retighten screws (2) and Allen screws (3). Risk of explosion! When the screws for the transmitter housing are loosened, the explosion protection is suspended. Tighten all screws (2, 3) for the transmitter housing prior to commissioning. 3.3 Cable entries 1 2 Fig. 10 1 2 3 G00759 The devices are delivered with 1/2" NPT or PF 1/2" threads with protective shipping plugs (1). Unused cable entries must be closed prior to commissioning using either approved threaded pipe connections or cable glands according to national regulations (NEC, CEC). Make sure that the threaded pipe connections, cable glands and possibly plugs are installed properly and sealed. If the device is to be operated in areas with combustible s, a threaded pipe connection or cable gland with suitable approval must be used. 14 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Mounting 3.4 High temperature version The high temperature design allows for complete thermal insulation of the sensor, up to the maximum illustrated device height. The pipeline and sensor must be after installing the unit according to the following illustration. The thermal resistance of the insulation must not exceed λ = 0.036 W/(mK); if it does, the thickness of the insulation must be reduced accordingly. 1 Fig. 11 1 Insulation The surface temperature depends on the fluid temperature. G00654 Model name FEP325 / FEH325 FEP315 / FEH315 Maximum surface temperature T 85 C (185 F)... T medium T 70 C (158 F)... T medium 3.5 Protection class IP 68 For installation, see the commissioning instruction. 3.6 Information about using the device in areas with combustible The device is approved for use in potentially explosive areas (gas and ). The Ex certification is provided on the name plate. Risk of explosion! The explosion protection is also provided by the housing. Modifications to the housing are not allowed (e.g., removing or omitting parts). 3.6.1 Maximum Allowable Surface Temperature Model name FEP325 / FEH325 FEP315 / FEH315 FET325 Maximum surface temperature T 85 C (185 F)... T medium T 70 C (158 F)... T medium T 70 C (158 F) 3.6.2 Minimum signal cable length In potentially explosive atmospheres, the signal cable must measure least 5 m (16.40 ft). SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 15

Mounting 3.7 Electrical connection Electrical connection should be performed by following the information in the operating instructions OI/FEP300/FEH300 or the commissioning instructions CI/FEP300/FEH300. According to NEC standards, the separate ground connection between flowmeter sensor and transmitter can be established as follows: 1. Route the steel wire (1) in the signal cable under the clip. 2. Fit the steel wire (1) with protective tubing and wire end sleeve (2). 3. Connect to the grounding screw (3). 1 2 3 G00760 Fig. 12 16 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

4 Ex relevant specifications for operation in Div. 1 4.1 Electrical connection Ex relevant specifications for operation in Div. 1 Important The housing for the transmitter and flowmeter sensor must be connected to the potential equalization PA. The operator must ensure that when connecting the protective conductor (PE) no potential differences can occur between protective conductor and potential equalization (PA). On the design with external transmitter, the signal cable between the flowmeter sensor and the transmitter must measure at least 5 m (16.4 ft). FM-compliant installations must be performed in accordance with "Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations" (ANSI/ISA RP 12.6) and "National Electric Code " (ANSI/NFPA 70 Sections 504 and 505). A temperature of 70 C (158 F) at the cable entry is assumed for the Ex calculations. Therefore, the cables used for the auxiliary power supply and the signal inputs and outputs must have a minimum specification of 70 C (158 F). SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 17

Ex relevant specifications for operation in Div. 1 4.1.1 Connection diagram for models FEP315, FEH315, FEP325, and FET325 in Div. 1 FEP315 FEH315 A 6 1+ 2- L N 24 V + - + - + - + - 31 32 51 52 81 82 41 42 M1 M2 D1 D2 3 2S E2 E1 1S SE 6 6 { 1 PE { { { { 2 3 4 5 FEP325 FET325 7 8 9 10 11 12 13 6 Fig. 13 A Transmitter B Flowmeter sensor 1 Supply power: See name plate 2 Current output (terminals 31/32) Dependent upon the device design, an "active" or a "passive" output will be available. On the device design for operation in Div. 1, the configuration of the current output cannot be changed on site. Active: 4... 20 ma, HART protocol (standard), load: 250 Ω R 300 Ω Passive: 4... 20 ma, HART protocol (standard), load: 250 Ω R 650 Ω, supply voltage for the current output: minimum 11 V, maximum 30 V at terminals 31/32. 3 Digital output DO1 (terminal 51/52) The output is always a "passive" output (optocoupler). Data for the optocoupler: U max = 30 V, I max = 220 ma Function can be configured locally as "Pulse Output" or "Digital Output" using software. Factory setting is "Pulse Output". Configuration as pulse output. Maximum pulse frequency: 5,250 Hz, pulse width: 0.1 2,000 ms. The pulse factor and pulse width are interdependent and are calculated dynamically. Configuration as contact output. Function: System alarm, empty pipe alarm, max./min. alarm, flow direction signaling, other B M1 M2 D1 D2 3 E2 E1 SE All inputs and outputs are electrically isolated from each other and from the supply power. The electrical specifications given are operating values. 6 6 G00866 4 Digital input: (terminal 81/82) Only available in conjunction with "passive" current output. Function can be configured locally using software: External output switch-off, external totalizer reset, external totalizer stop, other Data for the optocoupler: 16 V U 30 V, Ri = 2 kω 5 Digital output DO2 (terminal 41/42) The output is always a "passive" output (optocoupler). Data for the optocoupler: U max = 30 V, I max = 220 ma Function can be configured locally as "Pulse Output" or "Digital Output" using software. Factory setting is "Digital Output", flow direction signaling. 6 Equipotential bonding 7 Brown 8 Red 9 Orange 10 Yellow 11 Green 12 Blue 13 Violet 18 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Ex relevant specifications for operation in Div. 1 4.1.2 Connection diagram for model FEP325 in Div. 1 and the FET325 transmitter in Div. 2 or FET321 outside the Ex area FEP325 flowmeter sensor in the Ex area (Div. 1) FET325 transmitter in the Ex area (Div. 2) FET321 transmitter outside the Ex area 6 6a 6 6 A 1+ 2- L N 24 V + - + - + - + - 31 32 51 52 81 82 41 42 M1 M2 D1 D2 3 2S E2 E1 1S SE 6/6a { 1 PE { { { { 2 3 4 5 7 8 9 10 11 12 13 B M1 M2 D1 D2 3 E2 E1 SE 6 G00867 Fig. 14 A Transmitter B Flowmeter sensor 1 Supply power: See name plate 2 Current output (terminals 31/32) The current output can be configured locally as an "active" or "passive" output. Active: 4... 20 ma, HART protocol (standard), load: 250 Ω R 650 Ω Passive: 4... 20 ma, HART protocol (standard), load: 250 Ω R 650 Ω, Supply voltage for the current output: min. 11 V, max. 30 V at terminals 31/32. 3 Digital output DO1 (terminal 51/52) The digital output can be configured locally as an "active" or "passive" output. Active: U = 19... 21 V. I max = 220 ma, f max 5250 Hz Passive: U max = 30 V, I max = 220 ma, f max 5,250 Hz Function can be configured locally as "Pulse Output" or "Digital Output" using software. Factory setting is "Pulse Output". Configuration as pulse output Max. pulse frequency: 5250 Hz, pulse width: 0.1 2.000 ms. The pulse factor and pulse width are interdependent and are calculated dynamically. Configuration as contact output. Function: System alarm, empty pipe alarm, max./min. alarm, flow direction signaling, other All inputs and outputs are electrically isolated from each other and from the supply power. The electrical specifications are operating values. 4 Digital input: (Terminal 81/82) Function can be configured locally using software: External output switch-off, external totalizer reset, external totalizer stop, other Data for the optocoupler: 16 V U 30 V, Ri = 2 kω 5 Digital output DO2 (terminal 41/42) The output is always a "passive" output (optocoupler). Data for the optocoupler: U max = 30 V, I max = 220 ma, f max 5250 Hz, Function can be configured locally as "Pulse Output" or "Digital Output" using software. Factory setting is "Digital Output", flow direction signaling. 6 Potential equalization PA 6a Functional ground (only with flowmeter sensor FET321 in explosion-free area) 7 Brown 8 Red 9 Orange 10 Yellow 11 Green 12 Blue 13 Violet SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 19

Ex relevant specifications for operation in Div. 1 4.2 Electrical data When operating in potentially explosive areas, observe the following electrical data for the signal inputs and outputs of the transmitter. For the correct current output design (active/passive), see the marking contained in the device's terminal box. Model: FEP315, FEH315, or FET325 Inputs and outputs Type of protection XP U M I M [V] [ma] Operating values U N [V] I N [ma] Type of protection NI U N I N [V] [ma] Active current output Terminal 31/32 60 35 30 30 30 30 Passive current output Terminal 31/32 60 35 30 30 30 30 Passive digital output DO2 Terminal 41/42 60 35 30 220 30 220 Passive digital output DO1 Terminal 51/52 Passive digital input DI 3) Terminal 81/82 Type of protection IS U O [V] I O [ma] P O [mw] C O [nf] C OPA [nf] L O [mh] 20 100 500 210 195 6 U I [V] I I [ma] P I [mw] C I [nf] C IPA [nf] L I [mh] 60 425 2000 8,4 24 0,065 U I I I P I C I C IPA L I [V] [ma] [mw] [nf] [nf] [mh] 60 500 2000 8,4 24 170 U I [V] 60 35 30 220 30 220 60 60 I I [ma] 425 1) 500 2) 425 1) 500 2) P I [mw] C I [nf] C IPA [nf] L I [mh] 2000 3,6 3,6 170 2000 3,6 3,6 170 60 35 30 10 30 10 60 500 2000 3,6 3,6 170 1) For "active" current output 2) For "passive" current output 3) Only available in conjunction with passive current output All inputs and outputs are electrically isolated from each other and from the supply power. Special connection conditions: The output circuits are designed in such a way that they can be connected to both intrinsically-safe and non-intrinsically-safe circuits. It is not permitted to combine intrinsically safe and non-intrinsically safe circuits. On intrinsically safe circuits, equipotential bonding must be in place along the entire length of the cable used for the current outputs. The rated voltage of the non-intrinsically safe circuits is U M = 60 V. Provided that rated voltage U M = 60 V is not exceeded if connections are established to non-intrinsically safe external circuits, intrinsic safety is still guaranteed. If the installation is changed from type of protection "non-intrinsically safe" to "intrinsically safe" or vice versa, the device must be checked in accordance with the instructions contained in section 6.4 "Changing the type of protection". 20 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Ex relevant specifications for operation in Div. 1 4.3 Temperature values Model name FEP315 / FEH315 FEP325 FET325 Surface temperature 70 C (158 F) 85 C (185 F) 70 C (158 F) The surface temperature depends on the fluid temperature. With increasing fluid temperature > 70 C (158 F) or > 85 C (185 F) the surface temperature also increases to the level of the fluid temperature. Important The maximum permissible fluid temperature depends on the lining and flange material, and is limited by the operating values in Table 1 and the explosion protection specifications in Tables 2... n. Table 1: Fluid temperature as a function of lining and flange material Models FEP315/FEP325 Materials Fluid temperature (operating values) Lining Flange Minimum Maximum Hard rubber Steel -10 C (14 F) 90 C (194 F) Hard rubber Stainless steel -15 C (5 F) 90 C (194 F) Soft rubber Steel -10 C (14 F) 60 C (140 F) Soft rubber Stainless steel -15 C (5 F) 60 C (140 F) PTFE Steel -10 C (14 F) 130 C (266 F) PTFE Stainless steel -25 C (-13 F) 130 C (266 F) PFA Steel -10 C (14 F) 180 C (356 F) PFA Stainless steel -25 C (-13 F) 180 C (356 F) Thick PTFE Steel -10 C (14 F) 180 C (356 F) Thick PTFE Stainless steel -25 C (-13 F) 180 C (356 F) ETFE Steel -10 C (14 F) 130 C (266 F) ETFE Stainless steel -25 C (-13 F) 130 C (266 F) Model FEH315 Lining Process connection Material Fluid temperature (operating values) Minimum Maximum PFA Flange Stainless steel -25 C (-13 F) 180 C (356 F) PFA Wafer - -25 C (-13 F) 130 C (266 F) PFA Variable process connection Stainless steel -25 C (-13 F) 130 C (266 F) SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 21

Ex relevant specifications for operation in Div. 1 Table 2: Fluid temperature (Ex data) for ProcessMaster Model FEP315 Ambient temperature Nominal size DN 3... DN 100 DN 125... DN 2000 Design Temperature class (- 40 C) 1) - 20 C... + 40 C (- 40 C) 1) - 20 C... + 50 C (- 40 C) 1) - 20 C... + 60 C Not thermally & Thermally & Not thermally & Thermally & Not thermally & Thermally NT 130 C 90 C 30 C 80 C 40 C T1 180 C 120 C 20 C 120 C 20 C NT 130 C 90 C 30 C 80 C 40 C T2 180 C 120 C 20 C 120 C 20 C NT 130 C 90 C 30 C 80 C 40 C T3 180 C 120 C 20 C 120 C 20 C NT 120 C 90 C 30 C 80 C 40 C T4 120 C 120 C 20 C 120 C 20 C NT 85 C 70 C 30 C 80 C 40 C T5 85 C 85 C 20 C 85 C 20 C NT 70 C 70 C 30 C 70 C 40 C T6 70 C 70 C 20 CC 70 C 20 C NT 130 C 90 C 30 C 80 C 40 C T1 180 C 120 C 20 C 120 C 20 C NT 130 C 90 C 30 C 80 C 40 C T2 180 C 120 C 20 C 120 C 20 C NT 130 C 90 C 30 C 80 C 40 C T3 180 C 120 C 20 C 120 C 20 C NT 125 C 90 C 30 C 80 C 40 C T4 125 C 120 C 20 C 120 C 20 C NT 90 C 90 C 30 C 80 C 40 C T5 90 C 90 C 20 C 90 C 20 C NT 75 C 75 C 30 C 75 C 40 C T6 75 C 75 C 20 C 75 C 20 C & 1) Low-temperature version (option) NT standard version, T medium maximum 130 C (266 F) high-temperature version, T medium maximum 180 C (356 F) Not thermally : The flowmeter sensor is not surrounded by pipe insulation material. Thermally : The flowmeter sensor is surrounded by pipe insulation material. Important The standard version includes explosion protection for gases and. If the installation location for the device is classified as a potentially explosive area for gases and, the temperature data in the " & " columns in the table must be taken into consideration. If the installation location for the device is classified as a potentially explosive area for gases only, the temperature data in the "" columns in the table must be taken into consideration. 22 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Table 3: Fluid temperature (Ex data) for ProcessMaster Model FEP325 Ex relevant specifications for operation in Div. 1 Ambient temperature Nominal size DN 3... DN 100 DN 125... DN 2000 Design Temperature class (- 40 C) 1) - 20 C... + 40 C (- 40 C) 1) - 20 C... + 50 C (- 40 C) 1) - 20 C... + 60 C Not thermally & Thermally & Not thermally & Thermally & Not thermally & Thermally NT 130 C 110 C 110 C 110 C 110 C T1 180 C 160 C 150 C 160 C 150 C NT 130 C 110 C 110 C 110 C 110 C T2 180 C 160 C 150 C 160 C 150 C NT 130 C 110 C 110 C 110 C 110 C T3 180 C 160 C 150 C 160 C 150 C NT 120 C 110 C 110 C 110 C 110 C T4 120 C 120 C 120 C 120 C 120 C NT 85 C 85 C 85 C 85 C 85 C T5 85 C 85 C 85 C 85 C 85 C NT 70 C 70 C 70 C 70 C 70 C T6 70 C 70 C 70 C 70 C 70 C NT 130 C 110 C 110 C 110 C 110 C T1 180 C 160 C 150 C 160 C 150 C NT 130 C 110 C 110 C 110 C 110 C T2 180 C 160 C 150 C 160 C 150 C NT 130 C 110 C 110 C 110 C 110 C T3 180 C 160 C 150 C 160 C 150 C NT 125 C 110 C 110 C 110 C 110 C T4 125 C 125 C 125 C 125 C 125 C NT 90 C 90 C 90 C 90 C 90 C T5 90 C 90 C 90 C 90 C 90 C NT 75 C 75 C 75 C 75 C 75 C T6 75 C 75 C 75 C 75 C 75 C & 1) Low-temperature version (option) NT standard version, T medium maximum 130 C (266 F) high-temperature version, T medium maximum 180 C (356 F) Not thermally : The flowmeter sensor is not surrounded by pipe insulation material. Thermally : The flowmeter sensor is surrounded by pipe insulation material. Important The standard version includes explosion protection for gases and. If the installation location for the device is classified as a potentially explosive area for gases and, the temperature data in the " & " columns in the table must be taken into consideration. If the installation location for the device is classified as a potentially explosive area for gases only, the temperature data in the "" columns in the table must be taken into consideration. SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 23

Ex relevant specifications for operation in Div. 1 Table 4: Fluid temperature (Ex data) for HygienicMaster Model FEH315 Ambient temperature Nominal size DN 3... DN 100 Design Temperature class (- 40 C) 1) - 20 C... + 40 C (- 40 C) 1) - 20 C... + 50 C (- 40 C) 1) - 20 C... + 60 C Not thermally & Thermally & Not thermally & Thermally & Not thermally & Thermally NT 130 C 110 C 20 C 80 C 40 C T1 180 C 120 C 20 C 120 C 20 C NT 130 C 110 C 20 C 80 C 40 C T2 180 C 120 C 20 C 120 C 20 C NT 130 C 110 C 20 C 80 C 40 C T3 180 C 120 C 20 C 120 C 20 C NT 120 C 110 C 20 C 80 C 40 C T4 120 C 120 C 20 C 120 C 20 C NT 85 C 85 C 20 C 80 C 40 C T5 85 C 85 C 20 C 85 C 20 C NT 70 C 70 C 20 C 70 C 40 C T6 70 C 70 C 20 C 70 C 20 C & 1) Low-temperature version (option) NT standard version, T medium maximum 130 C (266 F) high-temperature version, T medium maximum 180 C (356 F) Not thermally : The flowmeter sensor is not surrounded by pipe insulation material. Thermally : The flowmeter sensor is surrounded by pipe insulation material. Important The standard version includes explosion protection for gases and. If the installation location for the device is classified as a potentially explosive area for gases and, the temperature data in the " & " columns in the table must be taken into consideration. If the installation location for the device is classified as a potentially explosive area for gases only, the temperature data in the "" columns in the table must be taken into consideration. 24 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Ex relevant specifications for operation in Div. 2 5 Ex relevant specifications for operation in Div. 2 5.1 Electrical connection 5.1.1 Connection diagram for models FEP315, FEH315, and FET325 in Div. 2, FET321 outside the Ex area FEP315, FEH315, FEP325 flowmeter sensor and FET325 transmitter in the Ex area (Div. 2) FEP315 FEP325 FET321 transmitter outside the Ex area FET321 6 6 FEH315 FEP325 FET325 6a 6 6 6 A 1+ 2- L N 24 V + - + - + - + - 31 32 51 52 81 82 41 42 M1 M2 D1 D2 3 2S E2 E1 1S SE 6/6a { 1 PE { { { { 2 3 4 5 7 8 9 10 11 12 13 Fig. 15 A Transmitter B Flowmeter sensor 1 Supply power: See name plate 2 Current output (terminals 31/32) The current output can be configured locally as an "active" or "passive" output. Active: 4... 20 ma, HART protocol (standard), load: 250 Ω R 650 Ω Passive: 4... 20 ma, HART protocol (standard), load: 250 Ω R 650 Ω Supply voltage for the current output: min. 11 V, max. 30 V at terminals 31/32. 3 Digital output DO1 (terminal 51/52) The digital output can be configured locally as an "active" or "passive" output. Active: U = 19... 21 V. I max = 220 ma, f max 5250 Hz Passive: U max = 30 V, I max = 220 ma, f max 5,250 Hz Function can be configured locally as "Pulse Output" or "Digital Output" using software. Factory setting is "Pulse Output". Configuration as pulse output Max. pulse frequency: 5250 Hz, pulse width: 0.1 2,000 ms. The pulse factor and pulse width are interdependent and are calculated dynamically. Configuration as contact output. Function: System alarm, empty pipe alarm, max./min. alarm, flow direction signaling, other B M1 M2 D1 D2 3 2S E2 E1 1S SE 6 G00873 4 Digital input: (Terminal 81/82) Function can be configured locally using software: External output switch-off, external totalizer reset, external totalizer stop, other Data for the optocoupler: 16 V U 30 V, Ri = 2 kω 5 Digital output DO2 (terminal 41/42) The output is always a "passive" output (optocoupler). Data for the optocoupler: U max = 30 V, I max = 220 ma, f max 5,250 Hz Function can be configured locally as "Pulse Output" or "Digital Output" using software. Factory setting is "Digital Output", flow direction signaling. 6 Potential equalization PA 6a Functional ground (only with transmitter FET321 outside the explosion-free area) 7 Brown 8 red 9 Orange 10 yellow 11 Green 12 blue 13 Violet All inputs and outputs are electrically isolated from each other and from the supply power. The electrical specifications are operating values. SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 25

Ex relevant specifications for operation in Div. 2 On the design with external transmitter, the signal cable between the flowmeter sensor and the transmitter must measure at least 5 m (16.4 ft). FM-compliant installations must be performed in accordance with "Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations" (ANSI/ISA RP 12.6) and "National Electric Code " (ANSI/NFPA 70 Sections 504 and 505). A temperature of 70 C (158 F) at the cable entry is assumed for the Ex calculations. Therefore, the cables used for the auxiliary power supply and the signal inputs and outputs must have a minimum specification of 70 C (158 F). 5.2 Electrical data When operating in potentially explosive areas, observe the following electrical data for the signal inputs and outputs of the transmitter. Model FEP315, FEH315, or FET325 Ex data Operating values NI Signal inputs and outputs U i [V] I i [ma] U i [V] I i [ma] current output Active/passive Terminal 31/32 Digital output DO1 Active/passive Terminal 51/52 Digital output DO2 Passive Terminal 41/42 Digital input DI Terminal 81/82 30 30 30 30 30 220 30 220 30 220 30 220 30 10 30 10 5.3 Temperature values Model name FEP315 / FEH315 FEP325 / FEH325 FET325 Surface temperature 70 C (158 F) 85 C (185 F) 70 C (158 F) The surface temperature depends on the fluid temperature. With increasing fluid temperature > 70 C (> 158 F) or > 85 C (> 185 F) the surface temperature also increases to the level of the fluid temperature. Important The maximum permissible fluid temperature depends on the lining and flange material, and is limited by the operating values in Table 1 and the explosion protection specifications in Tables 2... n. 26 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Table 1: Fluid temperature as a function of lining and flange material Models FEP315/FEP325 Ex relevant specifications for operation in Div. 2 Materials Fluid temperature (operating values) Lining Flange Minimum Maximum Hard rubber Steel -10 C (14 F) 90 C (194 F) Hard rubber Stainless steel -15 C (5 F) 90 C (194 F) Soft rubber Steel -10 C (14 F) 60 C (140 F) Soft rubber Stainless steel -15 C (5 F) 60 C (140 F) PTFE Steel -10 C (14 F) 130 C (266 F) PTFE Stainless steel -25 C (-13 F) 130 C (266 F) PFA Steel -10 C (14 F) 180 C (356 F) PFA Stainless steel -25 C (-13 F) 180 C (356 F) Thick PTFE Steel -10 C (14 F) 180 C (356 F) Thick PTFE Stainless steel -25 C (-13 F) 180 C (356 F) ETFE Steel -10 C (14 F) 130 C (266 F) ETFE Stainless steel -25 C (-13 F) 130 C (266 F) Models FEH315/FEH325 Lining Process connection Material Fluid temperature (operating values) Minimum Maximum PFA Flange Stainless steel -25 C (-13 F) 180 C (356 F) PFA Wafer - -25 C (-13 F) 130 C (266 F) PFA Variable process connection Stainless steel -25 C (-13 F) 130 C (266 F) Table 2: Fluid temperature (Ex data) for ProcessMaster model FEP315 and HygienicMaster model FEH315 ProcessMaster DN 3... DN 2000 Nominal size HygienicMaster DN 3... DN 100 Design Temperature class Ambient temperature - 20 C... + 40 C - 20 C... + 50 C - 20 C... + 60 C - 40 C... + 40 C 1) - 40 C... + 50 C 1) - 40 C... + 60 C 1) Thermally Not thermally Thermally Not thermally Not thermally & & NT 130 C 130 C - - - - - - 130 C T1 & 100 C 2) 110 C 3) & & Thermally & - - - - - - 80 C 40 C - - - - - - 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 40 C 180 C 40 C NT 130 C 130 C - - - - - - 130 C T2 100 C 2) 110 C 3) - - - - - - 80 C 40 C - - - - - - 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 40 C 180 C 40 C NT 130 C 130 C - - - - - - 130 C T3 100 C 2) 110 C 3) - - - - - - 80 C 40 C - - - - - - 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 40 C 180 C 40 C NT 130 C 130 C - - - - - - 130 C T4 100 C 2) 110 C 3) - - - - - - 80 C 40 C - - - - - - 130 C 130 C 130 C 130 C 130 C 130 C 130 C 130 C 130 C 40 C 130 C 40 C 1) Low-temperature version (option) 2) Temperature values for ProcessMaster 3) Temperature values for HygienicMaster NT standard version, T medium maximum 130 C (266 F) high-temperature version, T medium maximum 180 C (356 F) Not thermally : The flowmeter sensor is not surrounded by pipe insulation material. Thermally : The flowmeter sensor is surrounded by pipe insulation material. Important The standard version includes explosion protection for gases and. If the installation location for the device is classified as a potentially explosive area for gases and, the temperature data in the " & " columns in the table must be taken into consideration. If the installation location for the device is classified as a potentially explosive area for gases only, the temperature data in the "" columns in the table must be taken into consideration. SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 27

Ex relevant specifications for operation in Div. 2 Table 3: Fluid temperature (Ex data) for ProcessMaster model FEP325 and HygienicMaster model FEH325 ProcessMaster DN 3... DN 2000 Nominal size HygienicMaster DN 3... DN 100 Design Temperature class Ambient temperature - 20 C... + 40 C - 20 C... + 50 C - 20 C... + 60 C - 40 C... + 40 C 1) - 40 C... + 50 C 1) - 40 C... + 60 C 1) Thermally Not thermally Thermally Not thermally Not thermally & & & & NT 130 C 130 C - - - - - - 130 C 130 C - - - - - - T1 110 C 2) 120 C 3) & Thermally & 110 C - - - - - - 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C NT 130 C 130 C - - - - - - 130 C 130 C - - - - - - T2 110 C 2) 120 C 3) 110 C - - - - - - 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C NT 130 C 130 C - - - - - - 130 C 130 C - - - - - - T3 110 C 2) 120 C 3) 110 C - - - - - - 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C 180 C NT 130 C 130 C - - - - - - 130 C 130 C - - - - - - T4 110 C 2) 120 C 3) 110 C - - - - - - 130 C 130 C 130 C 130 C 130 C 130 C 130 C 130 C 130 C 130 C 130 C 130 C NT 95 C 95 C - - - - - - 95 C 95 C - - - - - - 95 C 95 C - - - - - - T5 95 C 95 C 95 C 95 C 95 C 95 C 95 C 95 C 95 C 95 C 95 C 95 C NT 80 C 80 C - - - - - - 80 C 80 C - - - - - - 80 C 80 C - - - - - - T6 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 1) Low-temperature version (option) 2) Temperature values for ProcessMaster 3) Temperature values for HygienicMaster NT standard version, T medium maximum 130 C (266 F) high-temperature version, T medium maximum 180 C (356 F) Not thermally : The flowmeter sensor is not surrounded by pipe insulation material. Thermally : The flowmeter sensor is surrounded by pipe insulation material. Important The standard version includes explosion protection for gases and. If the installation location for the device is classified as a potentially explosive area for gases and, the temperature data in the " & " columns in the table must be taken into consideration. If the installation location for the device is classified as a potentially explosive area for gases only, the temperature data in the "" columns in the table must be taken into consideration. 28 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Commissioning 6 Commissioning 6.1 Preliminary checks prior to start-up The following points must be checked before commissioning: The supply power must be switched off. The supply power must match information on the name plate. The pin assignment must correspond to the connection diagram. Sensor and transmitter must be grounded properly. The temperature limits must be observed. The sensor must be installed at a largely vibration-free location. The housing cover and the cover safety device must be sealed before switching on the supply power. Unused cable entries must be closed prior to commissioning using either approved threaded pipe connections or cable glands according to national guidelines (NEC, CEC). 6.2 Notes on combining the FEP325 flowmeter sensor with the FET325 transmitter Fig. 16: When combining the FEP325 flowmeter sensor with the FET325 transmitter, you must ensure that the flowmeter sensor is assigned to the transmitter correctly. The flowmeter sensor is identified by means of the suffix (X01, X02, etc.) that forms part of the order number on the name plate. The associated transmitter is identified by means of the suffix (Y01, Y02, etc.) that forms part of the order number on the name plate. G00875 SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 29

Commissioning 6.3 Special features of the device design for operation in Div. 1 6.3.1 Configuring the current output On the device design for operation in Div. 1, the configuration of the current output cannot be changed once set. The configuration required for the current output (active/passive) must be specified when the order is placed. For the correct current output design (active/passive), see the marking contained in the device's terminal box. 6.3.2 Configuration of the digital outputs On the device design for operation in Div. 1, digital outputs DO1 (51/52) and DO2 (41/42) can be configured for connection to a NAMUR switching amplifier. On leaving the factory, the device is configured with the standard wiring (non-namur). Important The outputs' type of protection remains unaffected by this. The devices connected to these outputs must conform to the applicable regulations for explosion protection. The jumpers are located on the backplane in the transmitter housing. 1 2 3 BR902 BR901 1 2 1 2 4 3 Fig. 17: BR902 for digital output DO1 BR902 in position 1: Standard (non-namur) BR902 in position 2: NAMUR G00874 BR901 for digital output DO2 BR901 in position 1: Standard (non-namur) BR901 in position 2: NAMUR Configure the digital outputs as described: 1. Switch off the supply power and wait at least 20 minutes before the next step. 2. Open the cover safety device (4) and housing cover (1). 3. Loosen screws (3) and pull out transmitter plug-in (2). 4. Insert the jumpers in the required positions. 5. Put the transmitter plug-in (2) back into the housing and retighten the screws (3). 6. Close the housing cover (1) and lock the cover by unscrewing the screw (4). 30 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Commissioning 6.4 Changing the type of protection Models FEP315, FEH315, FEP325, and FET325 can provide various types of protection during operation: When connected to an intrinsically safe circuit in Div. 1, operated as an intrinsically safe device When connected to a non-intrinsically safe circuit in Div. 1, operated as a device with a flameproof enclosure When connected to a non-intrinsically safe circuit in Div. 2, operated as a non-sparking device If a device which is already operational is required to provide a different type of protection, the following steps must be taken/insulation checks must be performed in accordance with applicable standards. No. 1. Protection type 2. Protection type Required step/check 1 Div. 1: Device with flameproof enclosure, non-intrinsicallysafe circuit Div. 1: Intrinsically safe circuits Switch off supply power. Use 500 VAC or 710 VDC to take the following measurements for one minute: Jumper terminals 31/32, 41/42, 51/52, 81/82. Then measure all jumpers (A,B,C,D) against one another. 31 32 41 42 51 52 81 82 A B C D G00884 Switch off supply power. Use 500 VAC or 710 VDC to take the following measurements for one minute: Jumper terminals 31/32, 41/42, 51/52, 81/82. Then measure against the housing. 31 32 41 42 51 52 81 82 2 Div. 1: Intrinsically safe circuits 3 Div. 2: Non-sparking Div. 2: Non-sparking Div. 1: Device with flameproof enclosure, nonintrinsically-safe circuit Zone 2: Non-sparking Div. 1: Intrinsically safe circuits Div. 1: Device with flameproof enclosure, nonintrinsically-safe circuit G00885 Visual inspection Special precautions/checks are not necessary. Visual inspection (no damage to the threads of the cover or the cable fittings) Special precautions/checks are not necessary. Perform the checks described under No. 1. Visual inspection (no damage to the threads of the cover or the cable fittings) SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 31

Maintenance 7 Maintenance 7.1 General information Repair and maintenance activities may only be performed by authorized customer service personnel. When replacing or repairing individual components, original spare parts must be used. Risk of explosion! When the housing cover is open, the explosion protection is suspended. Before opening the housing switch off the power to all connection lines and wait at least 20 minutes. Warning Electrical voltage risk! When the housing is open, EMC protection is impaired and protection against contact is suspended. Before opening the housing, switch off power to all connecting cables for the device. Warning - Potential damage to parts The electronic components of the printed circuit board can be damaged by static electricity (observe ESD guidelines). Make sure that the static electricity in your body is discharged before touching electronic components. Important Users must also observe the information in the operating and commissioning instruction for the device. 32 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Maintenance 7.2 Replacing the transmitter or sensor Important After replacing the transmitter, the system data must be reimported according to information in the operating instruction (see the chapter "Downloading the system data"). 7.2.1 Transmitter 1 2 3 4 3 Fig. 18 Replace the transmitter plug-in as follows: 1. Switch off the supply power and wait at least 20 minutes before the next step. 2. Release the cover safety device (4) and housing cover (1). 3. Loosen screws (3) and pull out transmitter plug-in (2). 4. Replace transmitter plug-in and retighten screws (3). 5. Close the housing cover (1) and lock the cover by unscrewing the screw (4). G00689-01 7.2.2 Flowmeter sensor 1 2 3 Fig. 19 Replace the flowmeter sensor as follows: 1. Switch off the supply power and wait at least 20 minutes before the next step. 2. Open the cover safety device (4) and housing cover (1). 3. Disconnect the signal cable (if necessary, remove the sealing compound). 4. Install the new sensor according to the installation instructions. 5. Complete the electrical connection according to the connection diagram. 6. Close the housing cover (1) and lock the cover by unscrewing the screw (3). G00698-01 SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 33

Spare parts list 8 Spare parts list 8.1 Fuses for transmitter electronics 1 1 2 G00690-01 Fig. 20 No. Name of part Order number 1 Fuse for supply power (1.0 A) D151B003U05 2 Fuse for coil circuit in the field housing unit (0.25 A) D151B003U02 8.2 Spare parts for the compact design 1 2 Fig. 21 No. Name of part Order number 1 Cable gland M20 x 1.5 D150A008U15 2 O-ring 118 x 3.7 (covered) D101A034U05 G00878 34 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN

Spare parts list 8.3 Spare parts for remote design 8.3.1 Field-mount housing 1+2 1+2 3 4 G00879 Fig. 22 No. Name of part Order number 1 Screw D004G108AU01 2 spring washer D085D020AU20 3 Contact board assy D682A016U01 4 Cable gland M20 x 1.5 D150A008U15 5 Cover for supply power connection (not shown) D355H303U01 8.3.2 Round field-mount housing 1 2 Fig. 23 No. Name of part Order number 1 Cable gland M20 x 1.5 D150A004U15 2 O-ring 118 x 3.7 (covered) D101A034U05 G00876 SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster EN - 35

Spare parts list 8.3.3 Flowmeter sensor (Zone 2/Div 2) 1 2 3 G00880 Fig. 24 No. Name of part Order number for FEH model for FEP model 1 O-ring D101A034U06 D101A034U06 2 Connection board (without preamplifier) D685A1090U01 D685A1090U01 Connection board (with preamplifier) D685A1089U01 D685A1089U01 3 Cable gland M20 x 1.5 D150A008U15 D150A008U15 8.3.4 Flowmeter sensor (Zone 1/Div 1) 1 2 Fig. 25 No. Name of part Order number 1 O-ring D101A034U06 2 Cable gland M20 x 1.5 D150A008U15 G00877 36 - EN ProcessMaster / HygienicMaster SM/FEP300/FEH300/FM/CSA-EN