Flow rate Indicator / Totalizer

Similar documents
Flow Monitor / Totalizer with linearization, high / low alarms, analog and pulse signal outputs and HART Communication

FLOW RATE INDICATOR / TOTALIZER

BATCH CONTROLLER DATASHEET D030 - BATCH CONTROLLER WITH ONE STAGE CONTROL

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR

DATASHEET F110 - FLOW RATE INDICATOR / TOTALIZER

DATASHEET F090 - GENERAL PURPOSE INDICATOR

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER

DATASHEET F110 - FLOW RATE INDICATOR / TOTALIZER

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER

FLOW RATE MONITOR / TOTALIZER

DATASHEET F010 - FLOW RATE INDICATOR

FLOW RATE MONITOR / TOTALIZER

BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT DATASHEET F130 - BATCH CONTROLLER

BATCH CONTROLLER DATASHEET F130 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT

TOTALIZER MONITOR DATASHEET F117 - TOTALIZER MONITOR WITH HIGH / LOW TOTALIZER ALARM AND ANALOG SIGNAL OUTPUT

BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE DATASHEET F131 - BATCH CONTROLLER

FLOW RATE MONITOR / TOTALIZER

BATCH CONTROLLER DATASHEET F131 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER

BATCH CONTROLLER DATASHEET F130 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT

DATASHEET F120 - FLOW RATE CONTROLLER

Electronic Data Devices

RATIO CONTROLLER DATASHEET F124 - RATIO CONTROLLER WITH ANALOG CONTROL OUTPUT AND HIGH / LOW ALARMS

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Preset counters, electronic

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Flowcomputer for Corrected Liquid Volume

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

General Specifications

Level Measurement Continuous level measurement Radar transmitters

Process display RIA 261

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

5-Digit Dual-line explosion-proof pulse input rate/totalizer

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

SONOMETER TM 1100 Ultrasonic compact energy meter

Coriolis Massflowmeter

Remote I/O. 74 Remote I/O. Remote I/O System

INFOCAL 8 Energy calculator

Oil & Gas / Heavy Industry Type 2REX-A-NA-SSI

Accutech BR10. Wireless base radio

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

FDY PC-Programmable Frequency-to-DC Transmitter with Display

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

TMU. Coriolis Mass Flow Meter. for liquids and gas

Digital Input Output Module for Zone 2 Series 9470/33

Coriolis Massflowmeter

Rudder or propeller angular position transmitter KINAX WT720

Rosemount 3101, 3102, and 3105

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Level Measurement Continuous level measurement Radar transmitters

Multiturn absolute encoder

Operating Instructions 12/2007 SITRANS F RA 110 ATEX. Intrinsically-safe flowrate indicator/totalizer. flow

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Temperature Input Module for Zone 1 Series 9482/32

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

LST100 Ultrasonic level transmitter for upstream oil and gas

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

ICARUS ELECTRONIC GAS VOLUME CONVERTER

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52

Multifunctional counter tico 772/773/774

Supercal 531 Multi function Integrator that lives up to Your highest expectations

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

Digital Input Output Module for Zone 1 Series 9470/32

SONOMETER TM 1100 Ultrasonic compact energy meter

Coriolis Mass Flow Meter Model TM

BATCHMATE 1500 Batch Control Computer Technical Bulletin

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Analog Universal Module HART for Zone 2 Series 9468/33

A6500-UM Universal Measurement Card

Electro-Magnetic Flowmeters COPA-XE

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

General Specifications

LAUREL ELECTRONICS, INC.

Isolators A3/1.

Digital Input Output Module for Zone 2 Series 9470/33

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

IP26 Series Current to Pneumatic Converter

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Level Plus. SoCLEAN Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

INSTRUCTION MANUAL (ATEX / IECEx)

Binary Output without Power Supply Series 9176

TIY Programmable, Isolated Thermocouple Transmitter combines

1) What meter do I need in this application?

Signet 9950 Dual Channel Transmitter

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Transcription:

Datasheet ER100(M) Robust explosion proof indicator Flow rate Indicator / Totalizer with linearization, analog and pulse signal outputs Advantages Save time and gain flexibility with the easytooperate through glass keypad: no need to remove the front cover or to arrange a work permit. Your crew is in control with our highly praised know one, know them all configuration structure, saving time, cost and aggravation. Easy installation with the spacious chamber and plug and play connectors. Cost saving with an easy to install, 1 NPT thread for flow meter mounting. Key information at a glance as the display shows flow rate, total, measuring units and a flow rate indicating speedometer. Features Explosion proof according ATEX, IECEx, FM and CSA cus. Easy Kfactor and engineering unit configuration for volumetric or mass. 7 digit flow rate / total and 11 digit accumulated total. 16 point linearization of the flow curve with interpolation. Bright LED backlight. Power options: Loop powered, battery and 9 27V DC. Sensor supply DC. Modbus communication option RS485. Outputs Isolated, loop powered 4 20mA output according to linearized flow rate. Scaled pulse output according to linearized accumulated total. Inputs Ability to process all types of volumetric or mass flow meter signals: Reedswitch, NAMUR, NPN/PNP pulse, Sine wave (coil), Active pulse signals. Applications Flow measurement with mechanical flow meters where a precise calculation over the full measurement range is required. Or if retransmission of the flow rate and/or totalizer functions or serial communication is desired. The ER100(M) offers you a flow rate indicator / totalizer designed to be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The ER100(M) is always your first and safest choice in explosion proof applications. Your first and safest choice for explosion proof indicators. Datasheet ER100(M) 1

General information Introduction The ER100(M) distinguishes itself by its quality and functionality driven European design and manufacturing. It is more than fulfilling the rules for explosion proof design, it is about safety during the daily operation. Often, the environment is much tougher than the explosion proof requirements demand. Thus dangerous conditions may be experienced due to a broken enclosure or a poorly made flame path. Ruggedness and reliability is where Brodie International stands for and it is now available in a comprehensive well designed and purpose driven explosion proof flow rate indicator / totalizer. Display The unique LCD display provides multiple flow data at a glance. The main information is displayed with 7 digits (12mm, 0.47 ) to show total or flow rate and 11 digits (7mm, 0.28 ), which can be set to show flow rate and accumulated total. Onscreen engineering units are easily configured from a comprehensive selection, while different units for flow rate and total can be displayed simultaneously. The speedometer offers a quick impression of the actual flow rate. For good readings in full sunlight and darkness, the ER100(M) is provided with a bright backlight. When battery powered the backlight is only operational after a keypad touch, to safe battery life. Easytooperate through glass keypad Robust entry threads Configuration Each setting is clearly indicated with an alphanumerical description, which avoids confusing abbreviations. Operation Operation is done via the optical, easytooperate, through glass keypad without having to remove the front cover. These optical keys can be disabled. For easy handheld configuration there are three mechanical push buttons on the bottom side of the display collar. All settings are accessed via a simple operator menu that can be passcode protected. Your first and safest choice for explosion proof indicators. Datasheet ER100(M) 2

Flow meter input The ER100(M) accepts most input signals for volume flow or mass flow meters. The input signal type can be selected in the configuration menu without having to adjust any sensitive mechanical dipswitches or jumpers. In addition to the average KFactor, 16 linearization points can be entered with their frequencies or values. The unit will interpolate between these points greatly enhancing accuracy in any flow range. Analog output The linearized flow rate is transmitted with the galvanically isolated 4 20mA output signal. The ER100(M) can even be loop powered via the isolated loopcurrent. Pulse outputs A scaled pulse output is available according the linearized accumulated total. The pulse length is user defined from 1msec up to 10 seconds. The output can be a passive NPN signal or a mechanical relay output. Power requirements Several power inputs are possible to power the ER100(M) and sensor. As standard, the ER100(M) can be loop powered via the isolated, twowire, analog output. The battery powered option with a long life lithium battery can power the ER100(M) including the backlight, but doesn t offer a real sensor supply. A real sensor supply of 8.2, 12 or 24V is optional available with the 9 27V DC. Hazardous areas The ER100(M) has been certified according ATEX, IECEx, FM and CSA cus with an ambient temperature of 40 C to 70 C (40 F to 158 F). The application range of the enclosure is very wide: The ATEX markings are: Gas: II 2 G Ex d IIC T6 Gb Dust: II 2 D Ex tb IIIC T85 C Db The IECEx markings are: Gas: Ex d IIC T6 Gb Dust: Ex tb IIIC T85 C Db The FM and CSA cus markings are: XP (Explosionproof): Class I, Division 1, Grps A, B, C, D. DIP (DustIgnitionproof): Class II/III, Division 1, Groups E, F and G. Class I, Zone 1, AEx d IIc T6 Gb, Zone 21, AEx tb IIIC T85 C Db. Communication All processed data and settings can be read and modified through the Modbus link RS485. Overview application ER100(M) Pulse output Analog output Modbus Communication Enclosures The aluminum IP66/IP67, NEMA 4X/7/9 explosion proof enclosure has an industrial two component coating and is better suitable for outdoor and chemical plant applications than powder coated alternatives. A major advantage for the installation engineer is the spacious midchamber for the cable entry in combination with the plugandplay connectors. Especially for straight flow meter mounting a 1 NPT connection is available (see page 4 for available NPT and Metric threads sizes). Remote control: reset total / clearlock Linearization Flow meter input USB Communication Your first and safest choice for explosion proof indicators. Datasheet ER100(M) 3

Dimensions enclosures Terminal connections 112mm (4.41 ) Main Electronics Module POWER REQUIREMENTS PULSE OUTPUT P1 P2 9 27V DC R1 R2 R3 Passive transistor output 133mm (5.24 ) Battery powered: (If supply 9 27V DC is connected, the battery supply will be switched off automatically.) ESeries SENSOR INPUT SENSOR SUPPLY ADDITIONAL INPUT COMMUNICATION LOOP POWERED ANALOG OUTPUT 148mm (5.83 ) 2 x Entry thread T1 S1 S2 S3 Coil Reed switch / NPN PNP 3V P3 E1 E2 Reset total/clearlock C1 C2 C3 C4 RS485 2 wire A B A1 A2 Isolated 4 20mA I / I / : Nonpolarity sensitive. Namur Active signal 3V 3V Battery Supply Module POWER REQUIREMENTS P5 P6 9 27V DC* P7 Entry thread T2 Enclosure types HA_ Aluminum Ex d enclosure. Weight 1300 gr. Display example scale 1:1 Enclosure drillings H_B T1: 2 x 3 /4 NPT / T2: 1 x 3 /4 NPT Your first and safest choice for explosion proof indicators. Datasheet ER100(M) 4

Typical wiring diagram ER100 Typical wiring diagram ER100M Power supply TERMINAL CONNECTORS Main Electronics Module ER100 A1 A2 e.g. indicator 9 27V DC POWER REQUIREMENT Analog output: (loop powered) Galvanically isolated 4 20mA 11 27V DC Power supply TERMINAL CONNECTORS Main Electronics Module ER100M A1 A2 e.g. indicator OUTPUT LOOP POWERED Analog output type: (loop powered) Galvanically isolated 4 20mA 11 27V DC C1 C2 C3 C4 Modbus communication (not used in this example) B A C1 C2 C3 C4 Modbus communication type CH: RS485 2 wire 3V lowpass filter E2 Additional input Reset total / Clearlock 3V lowpass filter E2 Additional input Reset total / Clearlock E1 E1 Circuit depends on type of signal P3 S3 S1 S2 Flow meter input type pulse Circuit depends on type of signal Signal P3 S1 S2 S3 Flow meter input type pulse Main supply P1 P2 R1 R2 R3 123456 e.g. counter output Power supply 9 27V DC Pulse output passive transistor 9 27V DC Earth Main supply P1 P2 R1 R2 R3 123456 e.g. counter output Power supply: 9 27V DC (not used in this example) Pulse output type: passive transistor * Supply voltage P3: DC to sensor R9 R8 TERMINAL CONNECTORS Battery Supply Module ER100M Back up battery supply Main supply P5 P6 P7 Power supply: 9 27V DC (not used in this example) *Supply voltage S3: 3V DC to sensor Your first and safest choice for explosion proof indicators. Datasheet ER100(M) 5

Technical specification General Display High intensity transflective numeric and alphanumeric LCD, UVresistant, with bright backlight. Intensity can be adjusted via the keypad. When battery powered, the backlight is only operational after a keypad touch to extend the battery lifetime. Dimensions Ø 65 x 45mm (2.56 x 1.77 ). Refresh rate Speedometer Operating temperature Ambient Power requirements Battery Seven 12mm (0.47 ) and eleven 7mm (0.28 ) digits. Various symbols and measuring units. User definable: 8 times/sec. 30 secs. To indicate the actual flow rate the bargraph runs from 0 to 100% in 20 blocks, each block is 5%. 40 C to 70 C (40 F to 158 F). Long life Lithium battery lifetime depends upon settings and configuration up to approx. 3 years. The battery can power the backlight for a short time after a keypad touch but cannot power the relay output (OR) or the real sensor supply (Terminal P3). Supply 9 27V DC. Consumption max. 4.5W Loop Sensor excitation Loop / Battery Supply Terminal connections Loop powered, analog output. 11 27V DC, Min. 3.5mA. Consumption max. 675mW (25mA @ 27VDC). The loop powered analog output cannot power the backlight, mechanical relay output (OR) or the real sensor supply (Terminal P3). Terminal S3: 3V DC for pulse signals and 1.2V DC for coil pickup, Iout max. 100μA. This is not a real sensor supply. Only suitable for sensors with a very low power consumption like coils (sine wave) and reedswitches. Terminal P3: DC 8.2V DC, Iout max. 20mA. 12V DC, Iout max. 30mA. 24V DC, Iout max. 75mA (this voltage varies depending on the input supply voltage) Removable plugin terminal strip. Wire max. 1.5mm 2 and 2.5mm 2. Data protection Passcode Directives & Standards EEPROM backup of all settings. Backup of running totals every minute. Data retention at least 10 years. Configuration settings can be passcode protected. EMC Directive 2014/30/EU, FCC 47 CFR part 15. Low voltage RoHS Directive 2014/35/EU. Directive 2011/65/EU. ATEX / IECEx Directive 2014/34/EU, IEC 600790, IEC 600791, IEC 6007931. FM Class 3600, 3615, 3616, 3810. CSA CSA 22.2 No. 25, No. 30, No. 61010112. UL UL 610101. IP & NEMA EN 60529 & NEMA 250. Hazardous area Explosion proof Ambient Ta 40 C to 70 C (40 F to 158 F). ATEX Gas: II 2 G Ex d IIC T6 Gb. certification Dust: II 2 D Ex tb IIIC T85 C Db. IECEx Gas: Ex d IIC T6 Gb. certification Dust: Ex tb IIIC T85 C Db. FM & CSA cus Class I, Div. 1, Grps A, B, C, D. certification Class II/III, Div. 1, Grps E, F, & G. Enclosure General Window Sealing Control keys Rating Class I, Zone 1, AEx d IIc T6 Gb, Zone 21, AEx tb IIIC T85 C Db. Glass window. Silicone. Three infrared keys with operation through the glass front window. IP66, IP67 / NEMA 4X / 7 / 9. Dimensions 112 x 133 x 148mm (4.41 x 5.24 x 5.83 ) W x H x D. Enclosure types HA_ Weight Enclosure drillings H_B Aluminum Ex d enclosure. 1550 gr. (3.41 lbs). 1650 gr (3.64 lbs) with battery supply. Entry threads: 3 x 3 /4 NPT Your first and safest choice for explosion proof indicators. Datasheet ER100(M) 6

Signal input Flow meter sensor Pulse Frequency KFactor Lowpass filter Additional input signal Function Duration Signal outputs Digital output Function Frequency Analog output Function Accuracy Coil / sine wave (COILHI: 20mVpp or COILLO: 90mVpp sensitivity selectable), NPN, PNP, reedswitch, Namur, active pulse signals 8 or 24V DC. Minimum 0Hz maximum 10kHz for total and flow rate. Maximum frequency depends on signal type and internal lowpass filter. E.g. reed switch with lowpass filter: max. frequency 120Hz. 0.000010 9,999,999 with variable decimal position. Available for all pulse signals. Terminal input to reset total remotely or to lock the clear total button. Internally pulledup switch contact NPN. Minimum pulse duration 100msec. Pulse output: Transmitting accumulated total. Max. 500Hz. Pulse length user definable between 1msec up to 10 seconds. One passive transistor output (NPN) not isolated. 300mA 50V @ 25 C. Transmitting linearized flow rate. Galvanically isolated, loop powered 4 20mA output 12 bit. Error 0.03% @ 20 C (Typical 45ppm/ C). Output signal can be scaled to any desired range. Operational Operator functions Displayed functions Total Units Linearized flow rate and / or total. Linearized total and accumulated total. Indicating speedometer for flow rate. Reset total by pressing the CLEARkey twice. 7 digits. L, m 3, US gal, igal, cf, Oil bbl, kg, ton, US ton, lb or none. Decimals 0 1 2 or 3. Accumulated total Total can be reset to zero. 11 digits. Units / decimals According to selection for total. Flow rate Units Can not be reset to zero. 7 digits. Decimals 0 1 2 or 3. Time units ml, L, m 3, mg, g, kg, ton, US ton, US gal, igal, Oil bbl, lb, cf, rev, none, scf, nm 3, nl or p. /sec /min /hr /day. Accessories General ER100(M) accessories Battery Long life Lithium battery lifetime depends upon settings and configuration up to approx. 3 years. Communication option Function Reading display information, reading / writing all configuration settings and data log extraction. Protocol Modbus ASCII / RTU. RS485 2wire Brodie International P.O. Box 450 (304590450) 19267 Highway 301 North Statesboro, GA 30461 Telephone: 1.912.489.0200 Telefax: 1.912.489.0294 Email: sales@brodieintl.com Internet: www.brodieintl.com Important: specifications are subject to change without notice. Copyright: Fluidwell bv 2017 ER100DATAENV1726