Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 MEAN WELL RCP-0 SERIES 0 Watt Front End Power Supply Power Supply { /mean-well-rcp-0-power-supply.html
SPECIFICATI MEAN WELL RCP-0 SERIES 0 Watt Front End Power Supply Power Supply MODEL RCP-0-12 RCP-0-24 RCP-0-48 DC VOLTAGE 12V 24V 48V RATED CURRENT CURRENT RANGE 0 ~ 0 ~ 0 ~ RATED POWER 8W RIPPLE & NOISE (max.) Note.2 150mVp-p 200mVp-p 300mVp-p OUTPUT VOLTAGE ADJ. RANGE(SVR) 11.6 ~ 12.4V 23.2 ~ 24.8V 46.3 ~ 49.7V VOLTAGE TOLERANCE Note.3 ±1.0% ±1.0% ±1.0% LINE REGULATI ±0.5% ±0.5% ±0.5% LOAD REGULATI SETUP, RISE TIME HOLD UP TIME (Typ.) ±0.5% 0ms, 60ms/230VAC at full load 16ms/230VAC at full load ±0.5% ±0.5% VOLTAGE RANGE Note.5 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 81% 87% 89% INPUT AC CURRENT (Typ.) 8.5A/115VAC 4.5A/230VAC 10.5A/115VAC 5.5A/230VAC 11A/115VAC 5.5A/230VAC INRUSH CURRENT (Typ.) LEAKAGE CURRENT COLD START 50A <1.1mA / 230VAC 105 ~ 125% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTI 13.2 ~ 16.2V 26.4 ~ 32.4V 52.8 ~ 64.8V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down AUXILIARY POWER 5V @ 0.3A REMOTE - CTROL By electrical signal or dry contact :short :open REMOTE SENSE Compensate voltage drop on the load wiring up to 0.5V FUNCTI OUTPUT VOLTAGE PROGRAMMABLE Adjustment of output voltage is allowable to ~ 110% of nominal output voltage. Please refer to the Function Manual. DC OK SIGNAL The isolated TTL signal out, Please refer to the Installation Manual AC OK SIGNAL The isolated TTL signal out, Please refer to the Installation Manual OVER TEMP WARNING Logic " High" for over temperature warning, Please refer to the Installation Manual, isolated signal ENVIRMENT WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATI -20 ~ +60 (Refer to "Derating Curve") 20 ~ % RH non-condensing -40 ~ +85, 10 ~ 95% RH ± 0.02%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.7KVDC ISOLATI RESISTANCE I/P-O/P, I/P-FG, O/P-FG:M Ohms / 500VDC / 25 / 70% RH Parameter Standard Test Level / Note EMC EMISSI Conducted Radiated Harmonic Current Voltage Flicker EN55022 (CISPR22) / EN55011 (CISPR11) EN55022 (CISPR22) / EN55011 (CISPR11) EN60-3-2 EN60-3-3 Class B Class B ----- ----- SAFETY & EMC (Note 4) EN55024, EN61204-3, EN60-6-2 Parameter ESD Radiated Standard EN60-4-2 EN60-4-3 Test Level / Note Level 3, 8KV air ; Level 2, 4KV contact Level 3 EMC IMMUNITY EFT / Burst Surge Conducted Magnetic Field Voltage Dips and Interruptions EN60-4-4 EN60-4-5 EN60-4-6 EN60-4-8 EN60-4-11 Level 3 Level 4, 2KV/Line-Line 4KV/Line-Earth Level 3 Level 4 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods MTBF 274K hrs min. Telcordia SR-332 (Bellcore) ; 107.3K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSI PACKING 295*127*41mm (L*W*H) 1.93Kg; 6pcs/12.6Kg/1.04CUFT NOTE File Name:RCP-0PEC 2016-01-30 /mean-well-rcp-0-power-supply.html
RCP-0 SERIES 0 Watt Front End Power Supply Power Supply Block Diagram PFC fosc : 110KHz PWM fosc : KHz I/P EMI FILTER ACTIVE INRUSH CURRENT LIMITING & PFC POWER SWITCH- ING O.L.P. & FILTER CURRENT SHARE ORING DIODE CURRENT SHARE PFC CTROL PWM CTROL DETECTI CIRCUIT V_TRIM O.V.P. CTROL / 2 I C FUNCTI OPTIAL 2 I C REMOTE - AUX POWER FAN DETECTI CIRCUIT & FILTER AC_OK DC_OK T_ALARM AUX POWER (5V/0.3A) AUX GND Static Characteristics 80 70 MODEL INPUT 180~264VAC 115VAC 12V 24V 48V 8W 8W LOAD (%) 60 50 40 VAC VAC 648W 54A 864W 36A 8W 7.2W 18.9A 95 115 264 INPUT VOLTAGE (VAC) 60Hz Derating Curve Efficiency vs Load (48V Model) 95 LOAD (%) 80 60 40 20-20 0 10 20 30 40 50 60 70 AMBIENT TEMPERATURE ( ) EFFICIENCY (%) 85 80 75 70 65 10% 20% 30% 40% 50% 60% 70% 80% % % LOAD The curve above is measured at 230VAC. File Name:RCP-0PEC 2016-01-30 /mean-well-rcp-0-power-supply.html
RCP-0 SERIES 0 Watt Front End Power Supply Power Supply Function Manual 1. Voltage Drop Compensation 1.1 Remote Sense The remote sense compensates voltage drop on the load wiring up to 0.5V. RCP-0 8 9 LOAD Sense lines should be twisted in pairs 1.2 Local Sense The, have to be connected to the,, respectively, as the following diagram, in order to get the correct output voltage if Remote Sense is not used. RCP-0 22 20 25 21 2. Remote / Control The power supply can be turned / together or separately by using the "Remote -" function. Between Remote - and Power Supply Status RCP-0 REMOTE 7-9 Switch Short Switch Open PIN7 REMOTE / PIN8 PIN9 /mean-well-rcp-0-power-supply.html File Name:RCP-0PEC 2016-01-30
RCP-0 SERIES 0 Watt Front End Power Supply Power Supply 3. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim) In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to ~110% of the nominal voltage by applying EXTERNAL RESISTANCE. PIN8 PIN9 PIN 13 V-TRIM RCP-0 8 V-TRIM 13 9 R1 R2 LOAD &, & also need to be connected on CN501 3.1 RCP-0-12 110 98 108 96 106 94 104 92 102 180K 240K 350K 560K 1.2M NC R1 ( Ω) NC 300K 120K 62K 31K 13K R2 ( Ω) 3.2 RCP-0-24 98 96 94 92 110 108 106 104 102 560K 750K 1M 1.6M 3.3M NC R1 ( Ω) NC 330K 130K 62K 30K 10K R2 ( Ω) 3.3 RCP-0-48 110 98 108 96 106 94 104 92 102 1.3M 1.7M 2.4M 3.6M 7.6M NC R1 ( Ω) NC 345K 140K 70K 36K 15K R2 ( Ω) 2 4. I C Bus Interface Option For the details of I C option, please refer to the Installation Manual. /mean-well-rcp-0-power-supply.html File Name:RCP-0PEC 2016-01-30
RCP-0 SERIES 0 Watt Front End Power Supply Power Supply Mechanical Specification Case No. 952A Unit:mm 41 7.1 12.5 295 24 127 39.1 66 46.3 3.6 5 max. CN501 SVR 46 DC OK AC OK Air flow direction LED Status Indicators & Corresponding Signal at Function Pins Function LED Description AC-OK AC-NG DC-OK DC-NG T-OK T-ALARM ---- ---- When input voltage 82V± 4V When input voltage 82V± 4V When output voltage 80% ± 5% of Vo rated. When output voltage 80% ± 5% of Vo rated. When the internal temperature (TSW1 & TSW2 short) is within safe limit When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm *Signal between function pin and "". Input / Output Connector Pin No. Assignment( CN501) : Postronic PCIB24W9M400A1 * Signal 0 ~ 0.5V 4.5 ~ 5.5V 0 ~ 0.5V 4.5 ~ 5.5V 0 ~ 0.5V 4.5 ~ 5.5V PSU Output 1 3 5 7 10 13 16 19 23 2 4 6 9 12 15 18 21 22 24 Mating Housing Postronic PCIB24W9F400A1 Pin No. Function Description 1,2,4 (signal) Positive output voltage. 3,5,6 (signal) Negative output voltage. 7 Remote- Each unit can separately turn the output on and off by electrical or dry contact. Short:, Open:. 8 9 10 AC-OK 11 12 CS 13 14 15 DC-OK V-TRIM T-ALARM +5V-AUX Installation Manual Please refer to the manual of RCP-0. /mean-well-rcp-0-power-supply.html Positive sensing for Remote Sense. Negative sensing for Remote Sense. Low : When input voltage is 82Vrms +/-4V. (Note.1) High : When input voltage in 82Vrms +/-4V. High : When Vout 80%+/-5%. Low : When Vout 80%+/-5% (Note.1) Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance between units. Connection for output voltage programming. High : When the internal temperature is within safe limit. (Note.1) Low : 10 below the thermal shut down limit. Auxiliary voltage output, 4.3~5.3V, referenced to GND-AUX(pin 7). The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by the remote / control. Auxiliary voltage output GND. The signal return is isolated from the output terminals ( & ). Serial clock used in the I C interface option. Refer to the Instruction Manual. (Note.1) Serial data used in the I C interface option. Refer to the Instruction Manual. (Note.1) I C interface address lines. Refer to the Instruction Manual. AC Ground connection. AC Line connection. AC Neutral connection. 16 17 GND-AUX SCL 18 SDA 19,20,21 A0,A1,A2 22 FG 23 AC/L 24 AC/N Note1: Non-isolated signal, referenced to the output terminal. File Name:RCP-0PEC 2016-01-30