MRG 96RM-E Flex RCM Mobile universal measurement device Supplementary description to the operation manual UMG 96RM-E

Similar documents
MRG 512-PRO PQ Flex Mobile universal measurement device Supplementary description to the operation manual UMG 512-PRO

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

Current / residual current and voltage transformers. Current / residual current and voltage transformers

UMG 509-PRO Power Quality Analyser User manual and technical data Part no Doc. no

UMG 96 RM-E Residual current monitoring (RCM) Power Analyser Operating instructions and technical data

Accessories. Accessories

UMG 512-PRO Power Quality Analyser User manual and technical data Part no Doc. no d 01/2018

Transienten. Datenspeicher

UMG 512 Operation manual and technical data

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill DOUBLE INSULATION. IMPORTANT: Read Before Using.

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Drill INSTRUCTION MANUAL. WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE 1 REFERENCE.

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill MT600 MT601 DOUBLE INSULATION. IMPORTANT: Read Before Using.

QUICK TESTER FOR TRANSFORMERS AND CAPACITORS

MultiMeter-Pocket CAT III 1000 V

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

User Manual Digital Multimeter

UMG 96 RM-EL Power Analyser Operating instructions and technical data

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

SAFETY AND OPERATING MANUAL

GENERAL OPERATIONAL PRECAUTIONS

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill DS4012 DOUBLE INSULATION. IMPORTANT: Read Before Using.

PPS MFS series - Installation Guide. Power Protector Stabilizer V 3.8 1

Flexible Rogowski Coil Integrator Kit with 0-5Vdc and 0-10Vdc User's Manual

SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

printed pages will not be updated

The frequency inverter continues to carry hazardous voltages for up to 5 minutes after it was switched off.

Instruction Manual MSC710 MSC710-U MSC710-I

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

TE 7-C. English. Printed: Doc-Nr: PUB / / 000 / 03

Installation and Operating Instructions for Phase Demodulator Type _.2

FREQUENCY-CONVERTER MFR 600A / 1500A Version 2

TT-SI MHz DIFFERENTIAL PROBE

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

Earth Fault Indicator EFI-BLZ-50 User Manual

312, 316, 318. Clamp Meter. Users Manual

INVERTEC 135S, 150S & 170S

2-Speed Hammer Drill HP2000 HP2020

TT-SI 9001 / TT-SI MHz Active Differential Probes

MAVOWATT 4 Multifunction Power Meter

netzerotools.com 374/375/376 Users Manual Clamp Meter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

UMG 96 RM Basic device Power Analyser Operating instructions and technical data

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Measuring current transformers of the W, W series

Digital Clamp Meter Model: &

NEXUS NX50-1, -2 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION

UMG 96 RM Basic device Power Analyser Operating instructions and technical data Item no

DVM1190 DIGITAL MULTIMETER

INVERTER INSTRUCTION MANUAL. 16 bit digital input function. Plug-in option FR-A7AX PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

374/375/376 Clamp Meter. Users Manual

WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY AND KEEP A COPY ON THE PROPERTY FOR FUTURE REFERENCE!

ENGLISH (Original instructions) INSTRUCTION MANUAL. Hammer Drill MHP161 DOUBLE INSULATION. IMPORTANT: Read Before Using.

ENGLISH (Original instructions) INSTRUCTION MANUAL. Hammer Drill HP1630 HP1631 DOUBLE INSULATION. IMPORTANT: Read Before Using.

Power supply CP-D 24/4.2 Primary switch mode power supply

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Power supply CP-D 12/2.1

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

Model UT20B: OPERATING MANUAL Table of Contents (1)

SAFETY AND OPERATING MANUAL

Circuit Breaker Finder

SAFETY AND OPERATING MANUAL. 750W/13mm IMPACT DRILL JM750ID

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

MULTI-PURPOSE SAW MODEL NO. OZMPS500A OPERATING INSTRUCTIONS

DM-45 Digital Multimeter

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Measuring current transformers of the W AB(P) series

Industrial Pressure Transducers

...thoroughly tried and tested!

BC145 SIGNAL ISOLATOR BOARD

Safety instructions and installation

External brake resistor AX2090-BW5x

GENERAL OPERATIONAL PRECAUTIONS PRECAUTIONS ON USING CUT-OFF MACHINE

Installation Instructions RF identification system Read/write head ANT430 ANT431

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

P331-2 set ESD generator (IEC )

ECA COMMERCIAL AMPLIFIER OWNER S MANUAL ECA-70MIXAMP V / 70V / 4Ω Amplifier ECA-70MIXAMP-1-60 OUTPUT LEVEL POWER MASTER MIC 1

TK 100 Probe Calibrator. Instruction Manual

323/324/325 Clamp Meter

PHV RO High Voltage Passive Probe. Instruction Manual

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

Impact Wrench MODEL TW1000. WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

OLA2 Open Loop Amplifier. Installation and Operating Manual Release May 2013

TT-SI MHz Active Differential Probe

Operator s Manual. PP016 Passive Probe

TA MHz oscilloscope probe TA MHz oscilloscope probe

Tapping Screw (W/Flange) 46 Cord Armor 47 Tube (D) 48 Cord. 45 Cord Clip. Tapping Screw (W/Flange) 10 Gear Cover Ass'y. 12 Socket (B) Ass'y

400 MHz Passive High-Voltage Probe R&S RT-ZH

ProfiScale MULTI Multimeter

AC/DC Current Oscilloscope Probe Model SL261

Electric Staple/Nail Gun

SAFETY AND OPERATING MANUAL

Installation Instructions RF-identification system Read/write head DTM434 DTM435 DTM436 DTM437

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Power supply CP-D 24/1.3

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

Transcription:

Doc. no. 2.040.127.0.b Subject to technical changes. www.janitza.com Mobile universal measurement device MRG 96RM-E Flex RCM Supplementary description to the operation manual UMG 96RM-E Janitza electronics GmbH Vor dem Polstück 6 D-35633 Lahnau Support tel. +49 6441 9642-22 Fax +49 6441 9642-30 E-mail: info@janitza.com Internet: http://www.janitza.com

Contents Safety information 3 Concerning this operation manual 4 Scope of supply - basic device 4 Connecting the measurement case 4 Reading out recordings 5 MRG 96RM-E Flex RCM views 5 Measurement transformer settings 6 Example connection - voltage measurement 7 Example connection - current measurement 7 Schematic diagram: MRG 96RM-E Flex RCM design 8 Technical data 9-2 -

Safety information Please read the operating instructions enclosed diligently, as well as all other publications that must be drawn upon for working with this measurement case and the accessories. Observe all safety instructions and warnings. Failure to comply with the instructions can result in personal injuries and/or damage to the product. The measurement case must only be operated by specialised personnel. Specialised personnel are persons, that based on their respective training and experience, are qualified to recognise risks and prevent potential dangers that can be caused by the operation or maintenance of the measurement case. Check the measurement case, the measurement wires and accessory parts for any signs of damage before use. Check whether there are cracks in the plastic of any parts missing. Pay particular attention to the insulation of the wiring and connectors. Defective parts must be replaced immediately. Do not use if damaged! Comply with all of the locally applicable and national safety regulations. Use personal protective equipment (e.g. approved rubber gloves, face protection and protective clothing) in order to avoid electric shocks and burning injuries. If the measurement case is not operated in accordance with the operation manual, protection is no longer ensured and hazards can be presented by the device! Do not work with the device if the front plate has been removed. Otherwise, you may come into contact with hazardous voltages! It is not permitted to use the device with the front plate removed! c m Do not use the measurement case in wet or moist environments or in the vicinity of explosive gases or vapours. Use the measurement case only with the measurement wires and adapter supplier. Exercise particular caution when connecting and removing the flexible current transformers and the gripping probes for the measured voltage. Ensure that the circuit to be measured is de-energised. Keep your fingers behind the finger protectors on the gripping measurement probes. Voltages and currents that are outside the permissible measurement range can destroy the device. The input voltage shall not be higher than the rated voltage of the measurement device. Disconnect the input signals before cleaning the measurement case. The UMG 96RM-E is not suitable for measuring DC voltages. Measured voltages and measured currents must derive from the same network. Voltages outside the rated range could destroy the measurement case. Incorrect network settings can cause faults in the network. c Attention! Fatal hazard due to electrical energy: High voltage spikes that are dangerous to touch can occur on current transformers that are driven with open-circuit secondary windings! For this reason, never operate current transformers with open-circuit secondary windings! First connect the current transformer lines to the corresponding measurement case inputs! - 3 -

Concerning this operation manual This description and the operating instructions for the device are part of the product. Read this description and the operation manual through prior to using the device. Keep this description and the operation manual throughout the complete service life of the product and have them readily available for reference. Scope of supply Pass this description and the operation manual on to each subsequent owner or user of the product. In the event of questions that are not covered by this operation manual for the UMG 96RM- E, please contact the support department of Janitza electronics GmbH (Tel. no. +49 6441-9642-22). This device must only be operated and repaired by specialised personnel. umber Designation 1 MRG 96RM-E Flex RCM 1 Supplementary description MRG 96RM-E Flex RCM 1 Operation manual UMG 96RM-E 1 Carry case 1 Power supply 24 V DC 3 Voltage pickoffs with fuses, black (gripping probes) 1 Voltage pickoff with fuse, blue (gripping probe) 1 Voltage measurement set (brown, black, grey, red, blue) 4 Rogowski coil with connection cable and plug (ø 95 mm, L 300 mm) 1 Cross patch cable, CAT 5e 2 Connection cable with plug for residual current measurement, 3 m (Residual current transformer not included in the scope of deliverables) Connecting the measurement case 1. Connect the power supply to the measurement case (1) and connect the power supply to 230 V / 50 Hz. 2. Carry out basic settings on the UMG 96RM-E (2), e.g. - Voltage transformer / current transformer settings - Recording configuration or - RCM measurement (the transformer for RCM measurement is not included in the scope of deliverables). The settings can be implemented via the accompanying GridVis software or directly on the UMG 96RM-E (see the accompanying instructions for the UMG 96RM-E for this). 4. Connect measured voltage with the voltage tap-offs via the voltage inputs (4) or with the measurement lines included in the scope of deliverables. In doing so, observe the applicable safety regulations. 5. Connect current transformer coils (operating current (5) or residual current (6)) with the measurement case via the screw terminals. 6. Connect the current transformer coils to the consumer to be measured. 7. Measurement starts 3. Set up the measurement transformer (3) - see "Measurement transformer configuration" chapter. - 4 -

Reading out recordings If you wish to read out the measured data, connect the measurement case to a PC via the Ethernet connection (7). The read-out is implemented via the GridVis software. MRG 96RM-E Flex RCM views 4. Voltage inputs U L1, U L2, U L3, U L L1 L2 L3 2. 3. Power Analyser UMG 96RM-E Measurement transducer UMG 96 RM I L1 I L3 AUX 24V DC 1A Ethernet I L5 I L6 Residual current measurement I L2 Current transformer inputs 5. Current transformer inputs I L1, I L2, I L3, I 7. 6. Ethernet connection RJ45 Residual current transformer inputs I 5, I 6 1. Supply voltage - 5 -

Measurement transformer settings Set the following parameters at the integrated measurement transducer: Compensate for the influence of the coil lengths through the potentiometer switching (1). To do so, set the parameters according to the table: (2) Setting Rogowski coil 300 mm Flex-CT-1A-300 mm DIP switch (1) The transformer ratio should be adapted in the UMG 96RM-E measurement device too in accordance with the table. Change the settings by means of the GridVis software or by entries on the device (measurement range: ratio x / 1 A ). Please refer to the UMG 96RM-E operation manual for this. Potentiometer Set the current measurement range with the DIP switch (2) in accordance with the table: Measurement range DIP switch 100 A 8 250 A 7 400 A 6 630 A 5 1000 A 4 1500 A 3 2000 A 2 4000 A 1-6 -

Example connection - voltage measurement Voltage pickoffs with fuse L1 L2 L3 Locking sleeve with bayonet catch for accommodating a fuse PE L1 L2 L3 Max. 20mm Example connection - current measurement I5 I6 I1 I2 I3 I PE L1 L2 L3 Voltage measurement terms connections Rogowski coil RCM measurement cable Residual current transformer not included in the scope of deliverables - 7 -

Schematic diagram: MRG 96RM-E Flex design Settings, parametrisation and safety information apply in accordance with the m installation and operating instructions enclosed. IDIFF IPE Up to 2 residual current measurements can be selected! 0-30 ma I5 RCM I6 MRG 96RM-E Flex RCM Ethernet 10/100Base-T RJ45 Switch PC PC Versorgungsspannung Auxiliary Supply I1 Strommessung 1-4 Current Input 1-4 Spannungsmessung 1-4 Voltage Input 1-4 I2 I3 I L1 L2 L3 L 24 V DC PE L1 L2 L3 Verbraucher Loads c Attention! C Please Fatal hazard due to electrical energy: High voltage spikes that are dangerous to touch can occur on current transformers that are driven with open-circuit secondary windings! For this reason, never operate current transformers with open-circuit secondary windings! First connect the current transformer lines to the corresponding measurement case inputs! ensure the correct setting of the current transformer, check the performance values of the individual phases - these must not possess any negative signs when drawing energy. Also check the power factor for plausibility. Turn the current transformer if necessary! - 8 -

Technical data Power supply Interface Measurement inputs Measurements Dimensions (L x W x H) Weight 230 V, 50 Hz, 50 VA Ethernet See UMG 96RM-E operating instructions See UMG 96RM-Eoperating instructions 350 mm x 295 mm x 150 mm 3,2 kg - 9 -