BUFUED PLANT Section covers the termination of buried service wire at junctions with other buried plant.

Similar documents
BURIED PLANT -BURIED WIRE TERMINATIONS

ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL

GENERAL SUBSCRIBER SERVICES TARIFF Pembroke Telephone Company, Inc. Third Revised Contents Sheet 1 Cancels Second Revised Contents Sheet 1

UNITED STATES OF DEPARTMENT OF AGRICULTURE Rural Utilities Service BULLETIN 1751F-815. Electrical Protection of Outside Plant

A. Product Description: Stranded conductor insulated wire.

UPC-LL Power Connection Kit

Canadian OSP Copper I-1. Table of Contents

Cable Hanging Instruction Manual

Pacific Antenna RF Probe assembly

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (ALUMACORE CABLE DESIGNS) FOR BPA

Wisconsin Contractors Institute Continuing Education

1\. power 3A speakerphone systems.

The Variable Threshold Neutral Isolator (VTNI)

COYOTE Terminal Closure (Single Chamber) Hermetically Sealed With Hardened Adapters

Lightning Strikes. Presented to the Greater Norwalk Amateur Radio Corporation Inc. February 8, 2017 Steven M. Simons W1SMS

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

Assembly Instructions

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

C-L-X ARMOR REMOVAL PROCEDURES

Inigo Sconce INSTALLATION INSTRUCTIONS P _2_A 1 of 5

Installation Instructions Hustler 6-BTV Trap Vertical

Instructions for Preparing OPTICAL GROUND WIRE IN AN ISOLATOR

LC31L-BAT Link Coupler

SECTION COMMUNICATIONS COPPER BACKBONE CABLING

SECTION COMMUNICATIONS COPPER BACKBONE CABLING

Article 250 Grounding & Bonding

Spiderbeam Balun Construction Guide

Ideal. Ergonomic, Cushion-Grip, Vinyl Coated

QSLVM2500 QSLV-M Cold Shrink Insulator

Surge Protection and Grounding Issues

SECTION COMMUNICATIONS COPPER OSP CABLING

A. Product Data: For each electrical identification product indicated.

CONTINUING EDUC ATION

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

Arched Top Lantern Pendant Assembly and Installation Instructions. Country of Destination: US/CN UK/EU/AUS Middle East

OMEGA. Communications Interface Cabinet. Antenna Installation Manual

American Electrical Institute

SECTION 10. SAFETY METHODS FOR TURNBUCKLES

Wiring of the Main Distribution Panelboard

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

Telephone Cable Locating Techniques

Installation personnel should be familiar with applicable codes or established practices for their locale. Weather Reistant PVC Jacket

RADIO AND TELEVISION SATELLITE EQUIPMENT

Article 700: Emergency Systems. 2.! Audible and visual signal devices shall be provided, where practicable to indicate.

CONNECTING BLOCKS 66-TYPE TOOLS, TERMINATING, ADAPTERS, AND MAINTENANCE. (5) Tighten screw.

National Radio Astronomy Observatory Socorro, NM EVLA Memorandum 41 Lightning Protection for Fiber Optic Cable. T. Baldwin June 05, 2002

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.

ARROW SAW PRECISE CUT 8000 RPM WITH DUST COLLECTING ATTACHMENT INSTRUCTION BOOK MODEL NO

ELECTRICAL CABLE SPLICE KIT. Roctest Limited, All rights reserved.

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

JANUARY 2002 ARMADILLO

This Manual Part recommends design criteria for resistors suitable for railway signaling circuits other than electronic.

User Guide for the Alpha Loop Sr Antenna

Cisco Aironet 2.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT2588P3M-N)

4200 JSP, KSP, LSP and MSP Cabinets

Coated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS

Nash Chandelier Assembly and Installation Instructions

AN EXAMPLE OF A STANDARD ARC FLASH PPE LABELING STRATEGY

TELEX. iiilhiijiri INSTRUCTION MANUAL ORDER NO. 411 TELEX COMMUNICATIONS, INC ALDRICH AVE SO. MINNEAPOLIS. MN U.SA.

VSOF-BS403A. Splice Closure for Fiber Optic Cable User Manual Rev.3

Schluter -DITRA-HEAT Repair procedure for the DHE-HK Heating Cable

Ameritron RCS-10 INTRODUCTION

1. You should have finished Study Session 1 and 2 and Quick Quiz 1 and 2 before starting this Session.

Installation Instructions Hustler 6-BTV Trap Vertical

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

Times Microwave Systems Hermetically Sealed Assemblies

ClampStar Safe-T-Link Tether Installation Instructions for Deadends

SECTION 7. SAFETYING

Article 225: Outside Branch Circuits And Feeders

Clearview Railing System Installation Instructions

EE 741. Primary & Secondary Distribution Systems

Wiring Repair WIRING REPAIR

SPORTCRAFT ANTENNAS. INSTALLATION INSTRUCTIONS for FLUSH WINGTIP COM ANTENNAS

COYOTE SPLICE CASE (ADOBE SERIES) FOR UNDERGROUND, AERIAL, AND BURIED SPLICES

SECTION ELECTRICAL IDENTIFICATION

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

4000 Series Pedestal and Pole- Mount Cabinets (Quick Connect)

Hullavator Gas Spring Replacement (simplified)

BUILD A HIGH PERFORMANCE TWO ELEMENT TRI-BAND CUBICAL QUAD. By Bob Rosier K4OCE INTRODUCTION THEORY AND GENERAL INFORMATION

SKDG Cable Repair Kit Instructions

MFJ-1750/1752 2M BASE ANTENNA with 5/8 GROUND PLANE Instruction Manual

OptiLiner Banded Liner System Bi-Directional Banding

FTTH ENGINEERING AND INSTALLATION INTRODUCTION

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

Attendee Announcements

Section 808. FENCING

Impact Wrench. 19 mm (3/4 ) MODEL 6906

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

M2 Antenna Systems, Inc. Model No: 20M5LD

INSTRUCTION MANUAL for MODEL TH6-DX "THUNDERBIRD" (389)

Construction Standard No:

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

The Queen Quilter Professional Quilters Kit Frame

Ten-Tec Model 3402 and 3403 Broadband Antennas Installation and Operation Manual PN 74393

Grounding and Bonding

ALTAI A8N SERIES SUPER WIFI BASE STATION INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

2. Conductor insulation should be supported and gripped by the terminal.

Transcription:

BELL SYSTEM PRACTICES Plant Series 1. GENERAL. BUFUED PLANT TERMINATION Of BURIED SERVICE WIRES AT JUNCTIONS WITH AERIAl. PLANT CONTENTS PAGE 2. JUNCTION WITH AERIAL CABLE 2 3. JUNCTION WITH MULTIPLE WIRE 5 4. JUNCTION WITH C RURAL WIRE 7 5. JUNCTION WITH OPEN WIRE 8 1. GENERAL 1.01 This section describes methods of terminating buried service wires at junctions with aerial plant such as aerial cable, multiple wire, C Rural Wire, or open wire. 1.02 This section has been reissued to: (a) Change title (b) Expand coverage of junctions with aerial plant (c) Delete material on junctions with buried plant. Since this is a general rev1s10n, arrows ordinarily used to indicate changes have been omitted. SECTION 629-720-200 Issue 2, February 1969 AT & TCo Standard 1.03 Section 629-720-205 covers the termination of buried service wire at junctions with other buried plant. 1.04 The armor wire of D Underground lvire or the aluminum tape of B Service Wire must always be grounde'd at the subscriber's protector when fed from any type of aerial or buried plant. Methods for grounding in a fuseless station protector are shown in Section 629-720-205. This grounding at subscriber's premises is required to protect against lightning damage and to minimize shock or fire hazards, caused by sustained power contacts. 1.05 In order to minimiz,e fire or shock hazards at the subscriber's premises when fuseless station protectors are used, a short piece of fine gauge wire must be placed so it will fuse open at the pole in the event of a sustained power contact. This fine gauge wire is known as a fusible link, and it must be smaller in current carrying capacity than the conductors of the service wire in order to make certain that it will burn open instead of the conductors of the buried service wire. In general, the 24-gauge copper conductors used in a cable terminal stub or in a connecting block with a 49-type cable terminal are satisfactory fusible links for D Underground or B Servict:~ vvire conductors. Block wire is a satisfactory fusible link for D Underground Vlire conductors, but is not satisfactory with B Service Wire conductors, because of an insufficient difference in fusing characteristics. American Telephone and Telegraph Company, 19!:i9 Printed in U.S.A. Page 1

SECTION 629-720-200 1.06 Underground or service wires should be identified at terminations by means of tags made from B Glass Tape. Cut about 5 inches of glass tape and wrap it around the wire, pressing the sticky side against itself to make the tag. It can be readily marked with. pencil or pen to designate the subscriber or to identify the route of the wire. These are shown in Fig. 1. Fig. 1-ldentifying Tags CESS STICKY E-:S TOGETHER 0 MAKE TAG / I J,O~'EZ\ II\!HWy\'zo, \. -~. N WRITE IDENTIFICATION IN PENCIL OR PEN 1.07 The B Wire Connector should be used to join buried service wire with PIC cable conductors inside a cable closure as indicated in Section 682-205-201. 1.08 Unterminated pairs of buried service wire should be prepared as described in Section 629-720-205. 2. JUNCTION WITH AERIAL CABLE 2.01 At the cable terminal or closure where buried service wire feeds from aerial cable and where the length of the buried service wire is: (a) 500 feet or less, do not bond the armor wire or the aluminum tape to the strand or terminal housing. This will protect the subscriber's location from possible fire caused by excessive power fault, should the circuit come in sustained contact with power lines of any voltage. (b) luore than 500 feet. Use D Underground Wire and bond the armor wire to the strand or terminal housing. When the length of buried wire is greater than 500 feet, the resistance of the armor wire, because of its length, will limit the fault current to safe values. The B Service Wire is not to be used for distances of more than 500 feet. 2.02 No carbon block protection is required between the cable conductors and the buried service wire eonductors unless severe lightning exposure exists. (See 2. 08.) Page 2

2.03 Buried service wire can be brought up a pole and terminated directly in a pole- or strand-mounted cable terminal or cable closure if the cable conductor is 24- or 26-gauge. Where fuseless protectors are used at the station and the cable conductor is 22- or 19-gauge and exposed to power contact, a fusible link is required between the cable pair and the service wire. As stated in NO. 0 U CABLE GUARD STRAPS AND 1-1/2 IN. STRAP NAILS, PLACED ABOUT 181N.APART SERVICE WIRE ISS 2, SECTION 629-720-200 1.05, the conductors in a cable stub or the connecting block of a 49-type cable terminal are satisfactory fusible links. At the groundline the wire should be protected with an 8-foot length of No. 0 U Cable Guard. A typical installation terminating in a 49-type cable terminal is shown in Fig. 2. 49-TYPE CABLE TERMINAL NOTE. 8FT LENGTH OF NO. 0 U CABLE GUARD SET ABOUT 12 IN. BELOW GROUNDLINE Fig. 2-Buried Plant Run up a Pole SEE PAR. 2.06 AND 2 07 FOR TERM INATING AND BONDING REQUIREMENTS. Page 3

conductors of the conne~cting block serve as the fusible links between the cable conductors and the buried plant conductors. Page 4 strand. For the latter purpose, block wire is required as a fusible link to prevent the common wire or aluminum tape from overheating. A typical installation is shown in Fig. 5. ARMOR WIRES BUNCH REMAINING ARMOR WIRES, CUT TO DESIRED LENGTH, AND INSERT IN BARf~EL OF NO. 31589 SOLDERLESS CONNECTOR Fig. 4-Armor Wire of D Underground Wire Terminated in No. 31589 Solderless Connector 2.07 Where the length of the buried wire is over 500 feet, grounding of the armor wire to the terminal housing with a solderless connector is required. In a 49-type cable terminal fasten the solderless connector under a convenient nut or screw in the base assembly. Special Lightn1ing Protection 2.08 In heavy lightning areas where the subscriber's station is severely exposed to lightning, it may be desirable to furnish additional lightning protection to buried service wires which are 500 feet or less in length. Under these conditions detailjed plans or other special instructions will authorize bonding the armor wire or aluminum tape at the aerial cable terminal. Such installations require the use of a 123- or 128Mtype protector (equipped with 2B1E Protector Units) and connection of the armor wire or aluminum tape to the ground post of the protector. A connection is also required between the protector ground post and the cable SECTION 629 720 200 Inside a Cable Terminal 2.04 Where the buried wire is 500 feet or less in length, grounding of the armor wire or aluminum tape at the cable terminal is omitted. Cut off the armor wire or aluminum tape and wrap with two turns of vinyl tape to protect against sharp edges (Fig. 3). CUT ALUMINUM TAPE AS ~LOSE TO OUTER JACKET ~IS PRACTICAL ' '' ' IIID-MWid /WRAP WITH TWO LAYERS OF VINYL TAPE 8 Wtu, 111 8 SERVICE WIRE /CUT ARMOR WIRE AS CLOSE / TO OUTER JACKET AS PRACTICAL 'bii!!&siiiif E!.I I It 'fil a (= ~~0 LAYERS D UNDERGROUND WIRE Fig. 3-Removal of Aluminum Tape or Armor Wire 2.05 Where the buried wire is over 500 feet in length and the armor wire of the D Underground Wire is to be grounded to the cable terminal, terminate the armor wir1e in a solderless connector as shown in Fig. 4. '2.06 Inside a cable terminal, the conductors of D Underground Wire or B Service Wire should be terminated on the binding post in the usual manner. The cable stub of the pole- or wall-mounted terminal provides the fusible link. In the case of a 49-type cable terminal, the 24 -gauge

123AIE PROTECTOR IN NO. 0 U CABLE GUARD STRAPS AND I-I/21N. STRAP NAILS, PLACED 3.. JUNCTION WITH MULTIPLE WIRE 3.. 01 Where multiple wire is exposed to power / TERMINATE BLOCK WIRE CONDUCTOR FRO.M PROTECTOR GROUND POST IN A LASHING WIRE CLAMP UNDERGROUND OR SERVICE WIRE SET ABOUT 121N. BELOW GROUND LINE Fig. 5-Termination for Special Lightning Protection contact and a fuseless protector is used at the station, B Service Wire should not be used with or fed from multiple wire, because of the relatively small size and low fusing level of the conductors or B Service Wire. A satisfactory fusible link is not available for use between multiple wire conductors and B Service Wire conductors. ISS 2, SECTION 629-720-200 3.02 D Underground Wire can be used with or fed from multiple wire where the multiple wire is exposed to power contact and fuseless station protection is used. D Underground Wire should be brought up a pole and terminated in a 101B2 vvire Terminal. At the groundline the wire should be covered with an 8-foot length of No. 0 U Cable Guard. Cut off the armor wire as shown in Fig. 3. Connect the conductors of D Underground Wire to the conductors of the multiple wire with Page 5 305A2 PROTECTOR MOUNTING BOND SERVICE WIRE SHIELD TO PROTECTOR AS SHOWN IN SECTION 629-720-205-~- ABOUT 181N. APART 8FT LENGTH OF NO. 0 U CABLE GUARD

Page 6 Fig. 6-Underground Wire Terminated to Multiiple Wire 3.03 The block wire serving as a fusible link between the D Underground Wire conductors and the multiple wire conductors can be terminated 0 D SECTION 629-720-200 block wire. Fig. 6 shows a typical example of D Underground Wire being connected to a 105-type wire terminal. 105A WIRE TERMINAL BLOCIK WIRE (00 NOT USE LARGER WIRE) 10182 WIF~E TERMINAL (SEE 462-240-120) 8FT LENGTH NO. 0 U CABLE GUARD SET ABOUT 12 IN. BELOW GROUNDLINE

in a 105A Wire Terminal, a 104-type wire terminal, a 116-type protector, a 108-type wire terminal, or in similar wire terminals used with multiple wire. 4. JUNCTION WITH C RURAL WIRE 4.01 Do not connect B Service Wire to C Rural Wire because of the small size of the conductors of the service wire. 107-TYPE WIRE TERMINA.L IOIB2 WIRE TERMINAL (SEE 462-240-120) 8FT LENGTH NO. 0 U CABLE GUARD SET ABOUT 12 IN. BELOW GROUNDLIIIIE ISS 2, SECTION 629-720-200 4.02 At the junction with C Rural Wire, D Underground Wire can be brought up a pole and terminated in a 101B2: Wire Terminal. At the groundline the D Underground Wire should be covered with an 8-foot length of No. 0 U Cable Guard. The armor wire should be cut off as shown in Fig. 3. Block wire should be used to bridle between the 101B2 Wire Terminal and the 107 -type wire terminal on the C Rural Wire. A typical instajlation is shown in Fig. 7. Fig. 7-Termination of Underground Wire and Rural Wire Page 7

Page 8 8 Pages 8FT LENGTH NO,O U CABLE GUARD SET ABOUT 12/N. BELOW GROUNDLINE Fig. 8-Termin,ation of Underground Wire ancl Open Wire 5.02 At the junction with open wire, D Underground Wire can be brought up a pole and terminated in a 101B2 Wire Terminal. At the groundline the wire should be covered with an 8-foot length of No. 0 U Cable Guard. The armor wire should be cut off as shown in Fig. 3. Block wire must be used between the protector and the open wire. A typical installation is shown in Fig. 8. D UNDERGROUND WIRE SECTION 629-720-200 5. JUNCTION WITH OPEN WIRE 5.01 B Service Wire should not be used with or fed from open wire because of the relatively small size and low fusing level of the conductors of the service wire. 10182 WIRE TEIRM/f\IAL NOTE: CONNECT THE BLOCK WIRE TO A 109 STEEL LINE WIRE AS FOLLOWS (SEE 462-240-200): (I) CRIMP A.034 H SPLICE SLEEVE TO THE END OF THE BLOCK WIRE WITH A SLEEVE PRESSING TOOL, AND FLATTEN THE RIDGES. (2) INSERT THE.034 H SPLICE SLEEVE AND BLOCK WIRE INTO A 109 X 109 8 ALUMINUM BRIDGING SLEEVE. (3) CRIMP THE BRIDGING SLEEVE TO THIE 109 WIRE WITH THE Q GROOVE OF A QC NICOPRESS TOOL. BRIDGE TO OTHER THAN 109 STEEL WIRE AS INDICATED IN SECTION 462-030-115.