TRANSMITTER Model: TX24

Similar documents
TRANSMITTER MODEL: KAS-2030M

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT

UEI FUSION PLUS QWERTY KB REMOTE 2012 MODEL: URC-5110BC0-XXX-R

TABLE OF CONTENTS SECTION TITLE PAGE. 5. LIST OF EUT, ACCESSORIES AND TEST EQUIPMENT 10 EUT and Accessory List EMI Test Equipment

ECHOSTAR 54.0 BRISBANE VOICE REMOTE 2017 MODEL: URC-2027BC0-R

ROKU REMOTE MODEL: RC07

COMCAST XFINITY HOME MOTION SENSOR MODEL: URC4470BC0-X-R

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

INTELLISWITCH FCC ID: TPZ Model: RA

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

FCC 47 CFR PART 15 SUBPART B

Matric Limited Hill City Road R.R. #1 Box 421A Seneca, PA 16346

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9

FCC PART 95 MEASUREMENT AND TEST REPORT. Powerwerx, Inc.

Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna

ENGINEERING TEST REPORT

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

FCC Rules and Regulations / Intentional Radiators. Operational in the MHz, MHz, MHz, and

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

HID GLOBAL CORPORATION

FCC CERTIFICATION TEST REPORT

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

FCC PART TEST REPORT. Weccan Industrial Limited

C-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply

TEST REPORT. Issued for: ShenZhen MYGT Co.,LTD D3 Tongfuyu Industrial Area Community of Shajing Town, Baoan, Shenzhen, China.

416 Maetan 3-Dong, Yeongtong-Gu, Suwon-Si, Gyeonggi-Do, Korea,

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

Compliance Engineering Ireland Ltd

Page 1 of 19 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR

FCC Part 15 Subpart B

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

APPROVED BY: DATE: 19-Aug-2011 Brian Boyea, EMC Engineer. TESTED BY: DATE: 12-Aug-2011 Arturo Ruvalcaba, EMC Engineer

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR. Dolphin CT50

FCC Verification TEST REPORT

Version TEST REPORT NO. DATE DESCRIPTION

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

STC Test Report. Date : Page 1 of 13 No. : HM161169

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR DUAL RADIO OUTDOOR ACCESS POINT MODEL NUMBER: AP-ONE FCC ID: SWX-AP1R2

ENGINEERING TEST REPORT NUMBER: EUS1. ON Model No.(s): BB-BONE-000 IN ACCORDANCE WITH: CFR 47, PART 15, SUBPART B, CLASS B VERIFICATION

HID GLOBAL CORPORATION

COMMUNICATION CERTIFICATION LABORATORY 1940 West Alexander Street Salt Lake City, UT

TEST REPORT. Issued for: RUIMA INTERNATIONAL(HK)INDUSTRIAL CO.,LIMITED NO.19 Ruixiang Road, Xinhua Industrial Zone, Huadu District, Guangzhou China

Sunlight Supply, Inc.

Revision history. Revision Date of issue Test report No. Description KES-RF-14T0042 Initial

TRFWL. Autostart Inc Rue Paré Mont-Royal, Québec Canada, H4P 2M2 EZSNAH2503

C E R T I F I C A T I O N

FCC Radio Test Report. Orpak Systems Ltd.

FCC CLASS B COMPLIANCE REPORT (DoC)

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B.

FCC TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...


CENTRE OF TESTING SERVICE INTERNATIONAL

TEST SUMMARY. Prüfbericht - Nr.: Test Report No FIELD STRENGTH OF FUNDAMENTAL RESULT: Passed % BANDWIDTH RESULT: Passed

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:

EMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight

TEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co.

Spectrian Dual Mode Cellular Power Amplifier Model No.: SCLPA 800 CR FCC ID: I2ONTHX51AA

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. RF ID Reader MODEL NUMBER: A-405 FCC ID: WFQITCS-A-405 IC: 10717A-ITCSA405

CENTRE OF TESTING SERVICE INTERNATIONAL

Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators

Tested To The. and. Report. We strive to TESTING

FCC & IC Certification. Test Report. FCC & Industry Canada Certification. Test Report. for Hetronic USA FCC ID: LW9-CS434TXN IC ID: 2219A-CS434TXN

8370 Court Avenue, Suite B-1 Ellicott City, Maryland (410) FCC CERTIFICATION

FCC Test Report (TR )

FCC REPORT. 570 E1 Camino Real #200, Redwood City, CA 94063, United Manufacturer:

FCC Test Report. Report No.: PTCDQ FC01

ENGINEERING TEST REPORT NUMBER: EUS1. ON Model No.(s): MB-PRO-MVK, MCU-430F5438A-MVK, AFE-BREAKOUT-MVK, RF-BREAKOUT-MVK, & RF-TCA8418-MVK

AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT

F2 Labs Peters Road Middlefield, Ohio United States of America

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

SILENT PARTNER Model No.: SCOOP FCC ID: WXMSCOOP. In Accordance With

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

FCC Part Transmitter Certification. Test Report

F2 Labs Peters Road Middlefield, Ohio United States of America

Test Report. Prepared for: Technologic Systems, Inc. Model: TS Description: Embedded Computer Board. Serial Number: N/A. FCC Part 15B Class A

FCC EVALUATION REPORT FOR CERTIFICATION

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

TEST REPORT. Issued for: Marvelmind Robotics Lugovaya str., 4 bld 5 room 17, Skolkovo Innovation Center, Moscow, , Russian Federation

TEST REPORT. Table of Contents

TEST REPORT. Issued for:

FCC/IC Test Report. : 2AOIMOMATA1 Equipment authorization required : SDoC IC ID

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

FCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29

Transcription:

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 1 of 17 FCC PART 15 SUBPART B and C TEST REPORT for TRANSMITTER Prepared for FOPRO, INC. 14 FO HOLLOW DRIVE LEWISTOWN, PENNSYLVNIA 17044 Prepared by: KYLE FUJIMOTO Approved by: JAMES ROSS COMPATIBLE ELECTRONICS INC. 114 OLINDA DRIVE BREA, CALIFORNIA 92823 DATE: AUGUST 31, 2009 REPORT APPENDICES TOTAL BODY A B C D E PAGES 17 2 2 2 14 12 49 This report shall not be reproduced except in full, without the written approval of Compatible Electronics.

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 2 of 17 Section / Title TABLE OF CONTENTS PAGE GENERAL REPORT SUMMARY 4 SUMMARY OF TEST RESULTS 4 1. PURPOSE 5 2. ADMINISTRATIVE DATA 6 2.1 Location of Testing 6 2.2 Traceability Statement 6 2.3 Cognizant Personnel 6 2.4 Date Test Sample was Received 6 2.5 Disposition of the Test Sample 6 2.6 Abbreviations and Acronyms 6 3. APPLICABLE DOCUMENTS 7 4. DESCRIPTION OF TEST CONFIGURATION 8 4.1 Description of Test Configuration EMI 8 4.1.1 Cable Construction and Termination 9 5. LISTS OF EUT, ACCESSORIES AND TEST EQUIPMENT 10 5.1 EUT and Accessory List 10 5.2 EMI Test Equipment 11 6. TEST SITE DESCRIPTION 12 6.1 Test Facility Description 12 6.2 EUT Mounting, Bonding and Grounding 12 6.3 Facility Environmental Characteristics 12 7. TEST PROCEDURES 13 7.1 RF Emissions 13 7.1.1 Conducted Emissions Test 13 7.1.2 Radiated Emissions (Spurious and Harmonics) Test 14 7.2 Bandwidth of the Fundamental 16 8. CONCLUSIONS 17

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 3 of 17 LIST OF APPENDICES APPENDI A B C D E TITLE Laboratory Recognitions Modifications to the EUT Additional Models Covered Under This Report Diagram, Charts, and Photos Test Setup Diagram Antenna and Amplifier Factors Radiated Emissions Photos Data Sheets LIST OF FIGURES FIGURE TITLE 1 Conducted Emissions Test Setup 2 Plot Map And Layout of Test Site 3 Meters 3 Plot Map And Layout of Test Site 10 Meters

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 4 of 17 GENERAL REPORT SUMMARY Compatible Electronics Inc. generates this electromagnetic emission test report, which is an independent testing and consulting firm. The test report is based on testing performed by Compatible Electronics personnel according to the measurement procedures described in the test specifications given below and in the "Test Procedures" section of this report. The measurement data and conclusions appearing herein relate only to the sample tested and this report may not be reproduced without the written permission of Compatible Electronics, unless done so in full. This report must not be used to claim product endorsement by NVLAP, NIST or any other agency of the U.S. Government. Device Tested: Product Description: Modifications: Customer: S/N: N/A See Expository Statement The EUT was not modified in order to meet the specifications. Foxpro, Inc. 14 Fox Hollow Drive Lewistown, Pennsylvania 17044 Test Date(s): August 10, 11, and 12, 2009 Test Specifications: EMI requirements CFR Title 47, Part 15, Subpart B Test Procedure: ANSI C63.4 Test Deviations: The test procedure was not deviated from during the testing. SUMMARY OF TEST RESULTS TEST DESCRIPTION RESULTS 1 Conducted RF Emissions, 150 khz 30 MHz The EUT does not directly or indirectly connect to the AC mains, thus this test was not performed. 2 Radiated RF Emissions 10 khz 4400 MHz ( Portion) 3 Radiated RF Emissions 30 MHz to 1000 MHz (Data Transfer Portion) Complies with the limits of CFR Title 47, Part 15, Subpart C, sections 15.205, 15.209, and 15.231. Highest reading in relation to spec limit: 78.77 dbuv @ 433.92 MHz (*Uc = 1.85 db) Complies with the limits of EN 55022. Highest reading in relation to spec limit: 25.33 dbuv @ 670.54 MHz (*Uc = 1.91 db) *U c = combined standard uncertainty

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 5 of 17 1. PURPOSE This document is a qualification test report based on the Electromagnetic Interference (EMI) tests performed on the,. The EMI measurements were performed according to the measurement procedure described in ANSI C63.4. The tests were performed in order to determine whether the electromagnetic emissions from the equipment under test, referred to as EUT hereafter, are within the Class B limits defined in CFR Title 47, Part 15, Subpart B; and CFR Title 47, Part 15, Subpart C, sections 15.205, 15.209, and 15.231 for the transmitter portion. Note: For the data transfer portion of the test, the EUT was within the Class B specification limits defined by C.I.S.P.R. Publication 22 for Information Technology Equipment for radiated emissions. Under paragraph G of section 15.109 of the Code of Federal Regulations Title 47, Part 15 of the FCC rules, FCC accepts the international standards set forth in C.I.S.P.R. Publication 22.

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 6 of 17 2. ADMINISTRATIVE DATA 2.1 Location of Testing The EMI tests described herein were performed at the test facility of Compatible Electronics, 114 Olinda Drive, Brea, California. 2.2 Traceability Statement The calibration certificates of all test equipment used during the test are on file at the location of the test. The calibration is traceable to the National Institute of Standards and Technology (NIST). 2.3 Cognizant Personnel Foxpro, Inc. John Dillon President Compatible Electronics Inc. Kyle Fujimoto James Ross Test Engineer Test Engineer 2.4 Date Test Sample was Received The test sample was received prior to the date of testing. 2.5 Disposition of the Test Sample The test sample has not yet been returned as of the date of this report. 2.6 Abbreviations and Acronyms The following abbreviations and acronyms may be used in this document. FCC Federal Communications Commission RF Radio Frequency EMI Electromagnetic Interference EUT Equipment Under Test P/N Part Number S/N Serial Number ITE Information Technology Equipment LISN Line Impedance Stabilization Network NVLAP National Voluntary Laboratory Accreditation Program CFR Code of Federal Regulations N/A Not Applicable Ltd. Limited Inc. Incorporated IR Infrared

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 7 of 17 3. APPLICABLE DOCUMENTS The following documents are referenced or used in the preparation of this EMI Test Report. SPEC CFR Title 47, Part 15 ANSI C63.4: 2003 TITLE FCC Rules Radio frequency devices (including digital devices) American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 khz to 40 GHz

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 8 of 17 4. DESCRIPTION OF TEST CONFIGURATION 4.1 Description of Test Configuration EMI Transmit Mode: The Trasnmitter, (EUT) was tested as a stand alone unit in three orthogonal axis. The EUT was continuously transmitting. The EUT s antenna is hard wired to the PCB. The EUT stops transmitting immediately after the button is released during normal usage. Data Transfer Mode: The, (EUT) was connected to a Digital Game Caller Model: SF1 via its data transfer port. The Digital Game Caller was also connected to a speaker via its speaker port. The EUT was uploading the playlist from the Digital Game Caller on a continuous basis. It was determined that the emissions were at their highest level when the EUT was operating in the above configuration. The final emissions data was taken in this mode of operation and any cables were maximized. All initial investigations were performed with the measurement receiver in manual mode scanning the frequency range continuously. Photographs of the test setup are in Appendix D of this report.

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 9 of 17 4.1.1 Cable Construction and Termination Cable 1 Cable 2 Data Transfer Mode Only This is a 2-meter unshielded cable connecting the speaker to the Digital Game Caller. The cable has a 1/8 inch mono connector at the Digital Game Caller end and is hard wired into the speaker. The cable was bundled to a length of 1 meter. Data Transfer Mode Only This is a 2-meter unshielded cable connecting the EUT to the Digital Game Caller. The cable has a 1/8 inch mono connector at each end. The cable was bundled to a length of 1 meter.

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 10 of 17 5. LISTS OF EUT, ACCESSORIES AND TEST EQUIPMENT 5.1 EUT and Accessory List EQUIPMENT MANUFACTURER MODEL SERIAL NUMBER NUMBER FCC ID TRANSMITTER (EUT) FOPRO, INC. T24 N/A C6M616 SPEAKER (for the Data Transfer Mode Only) WORKMAN THF-53FP N/A N/A DIGITAL GAME CALLER (for the Data Transfer Mode Only) FOPRO, INC. SF1 N/A DoC

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 11 of 17 5.2 EMI Test Equipment EQUIPMENT TYPE MANU- FACTURER MODEL NUMBER SERIAL NUMBER CALIBRATION DATE GENERAL TEST EQUIPMENT USED FOR ALL RF EMISSIONS TESTS CALIBRATION DUE DATE Computer Hewlett Packard 4530 US91912319 N/A N/A Spectrum Analyzer Main Section Spectrum Analyzer Display Section Hewlett Packard 8566B 3638A08768 August 22, 2008 Aug. 22, 2009 Hewlett Packard 85662A 3701A22262 August 22, 2008 Aug. 22, 2009 Quasi-Peak Adapter Hewlett Packard 85650A 2811A01363 August 22, 2008 Aug. 22, 2009 EMI Receiver Rohde & Schwarz ESIB40 100194 September 17, 2008 Sept. 17, 2010 Monitor Hewlett Packard D5258A TW74500641 N/A N/A RF RADIATED EMISSIONS TEST EQUIPMENT Biconical Antenna Com Power AB-900 15250 February 23, 2009 Feb. 23, 2010 Log Periodic Antenna Com Power AL-100 16060 June 15, 2009 June 15, 2010 Preamplifier Com-Power PA-102 1017 January 12, 2009 Jan. 12, 2010 Loop Antenna Com-Power AL-130 17089 September 29, 2008 Sept. 29, 2009 Horn Antenna Com-Power AH-118 071175 June 27, 2008 June 27, 2010 Microwave Preamplifier Com Power PA-122 181921 March 12, 2009 March 12, 2010 Antenna Mast Com Power AM-100 N/A N/A N/A

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 12 of 17 6. TEST SITE DESCRIPTION 6.1 Test Facility Description Please refer to section 2.1 and 7.1.2 of this report for EMI test location. 6.2 EUT Mounting, Bonding and Grounding The EUT was mounted on a 1.0 by 1.5 meter non-conductive table 0.8 meters above the ground plane. The EUT was not grounded. 6.3 Facility Environmental Characteristics When applicable refer to the data sheets in Appendix E for the relative humidity, air temperature, and barometric pressure.

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 13 of 17 7. TEST PROCEDURES The following sections describe the test methods and the specifications for the tests. Test results are also included in this section. 7.1 RF Emissions 7.1.1 Conducted Emissions Test The measurement receiver was used as a measuring meter. The data was collected with the measurement receiver in the peak detect mode with the "Max Hold" feature activated. The quasipeak was used only where indicated in the data sheets. A transient limiter was used for the protection of the measurement receiver s input stage, and the offset was adjusted accordingly to read the actual data measured. The LISN output was measured using the measurement receiver. The output of the second LISN was terminated by a 50-ohm termination. The effective measurement bandwidth used for this test was 9 khz. Please see section 6.2 of this report for mounting, bonding and grounding of the EUT. The EUT was powered through the LISN, which was bonded to the ground plane. The LISN power was filtered and the filter was bonded to the ground plane. The EUT was set up with the minimum distances from any conductive surfaces as specified in ANSI C63.4. The excess power cord was wrapped in a figure eight pattern to form a bundle not exceeding 0.4 meters in length. The conducted emissions from the EUT were maximized for operating mode as well as cable placement. The final data was collected under program control by the Compatible Electronics conducted emissions software in several overlapping sweeps by running the spectrum analyzer at a minimum scan rate of 10 seconds per octave. The final qualification data is located in Appendix E. Test Results: The EUT does not directly or indirectly connect to the AC mains, thus this test was not performed.

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 14 of 17 7.1.2 Radiated Emissions (Spurious and Harmonics) Test The measurement receiver was used as a measuring meter. A preamplifier was used to increase the sensitivity of the instrument. The measurement receiver was used in the peak detect mode with the Max Hold feature activated. In this mode, the measurement receiver records the highest measured reading over all the sweeps. The readings were averaged by a duty cycle correction factor, derived from 20 log (dwell time / one pulse train with blanking interval). The measurement bandwidths and transducers used for the radiated emissions test were: FREQUENCY RANGE TRANSDUCER EFFECTIVE MEASUREMENT BANDWIDTH 9 khz to 150 khz Active Loop Antenna 200 Hz 150 khz to 30 MHz Active Loop Antenna 9 khz 30 MHz to 300 MHz Biconical Antenna 120 khz 300 MHz to 1000 MHz Log Periodic Antenna 120 khz 1000 MHz to 4400 MHz Horn Antenna 1 MHz The final data was taken with a frequency span of 1 MHz for frequencies below 1000 MHz. For frequencies above 1000 MHz, the final data was taken with a frequency span of 10 MHz. The frequency span was reduced during the preliminary investigations as deemed necessary to distinguish between emissions from the EUT and any ambient signals. The open field test site of Compatible Electronics, Inc. was used for radiated emission testing. This test site is set up according to ANSI C63.4. Please see section 6.2 of this report for mounting, bonding, and grounding of the EUT. The turntable supporting the EUT is remote controlled using a motor. The turntable permits EUT rotation of 360 degrees in order to maximize emissions. Also, the antenna mast allows height variation of the antenna from 1 meter to 4 meters. Data was collected in the worst case (highest emission) configuration of the EUT. At each reading, the EUT was rotated 360 degrees and the antenna height was varied from 1 to 4 meters (for E field radiated field strength). The gunsight method was used when measuring with the horn antenna to ensure accurate results. The loop antenna was also rotated in the horizontal and vertical axis in order to ensure accurate results.

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 15 of 17 Radiated Emissions (Spurious and Harmonics) Test (Continued) The presence of ambient signals was verified by turning the EUT off. In case an ambient signal was detected, the measurement bandwidth was reduced temporarily and verification was made that an additional adjacent peak did not exist. This ensures that the ambient signal does not hide any emissions from the EUT. The EUT was tested at a 3-meter distance to obtain final test data for the transmit mode and at a 10-meter distance to obtain final test data for the data transfer mode. The final qualification data is located in Appendix E. Test Results: The EUT complies with the Class B limits of EN 55022; the Class B limits of CFR Title 47, Part 15, Subpart B; and CFR Title 47, Part 15, Subpart C, sections 15.205, 15.209, and 15.231.

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 16 of 17 7.2 Bandwidth of the Fundamental The -20 db bandwidth was checked to see that it was within 0.25% of the fundamental frequency for the EUT. Plots of the -20 db bandwidth are located in Appendix E. Test Results: The EUT complies with the limits of CFR Title 47, Part 15, Subpart C, section 15.231(c).

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 17 of 17 8. CONCLUSIONS The,, as tested, meets all of the Class B limits defined in CFR Title 47, Part 15 Subpart B; and Subpart C, sections 15.205, 15.209, and 15.231 for the transmitter portion. For the data transfer portion of the test, the EUT was within the Class B specification limits defined by C.I.S.P.R. Publication 22 for Information Technology Equipment for radiated emissions. Under paragraph G of section 15.109 of the Code of Federal Regulations Title 47, Part 15 of the FCC rules, FCC accepts the international standards set forth in C.I.S.P.R. Publication 22.

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page A1 APPENDI A LABORATORY RECOGNITIONS

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page A2 LABORATORY RECOGNITIONS Compatible Electronics has the following agency accreditations: National Voluntary Laboratory Accreditation Program - Lab Code: 200528-0 Voluntary Control Council for Interference - Registration Numbers: R-983, C-1026, R-984 and C-1027 Bureau of Standards and Metrology Inspection - Reference Number: SL2-IN-E-1031 Conformity Assessment Body for the EMC Directive Under the US/EU MRA Appointed by NIST Compatible Electronics is recognized or on file with the following agencies: Federal Communications Commission Industry Canada

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page B1 APPENDI B MODIFICATIONS TO THE EUT

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page B2 MODIFICATIONS TO THE EUT The modifications listed below were made to the EUT to pass FCC 15.231 and/or FCC Class B specifications. All the rework described below was implemented during the test in a method that could be reproduced in all the units by the manufacturer. No modifications were made to the EUT during the testing.

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page C1 APPENDI C ADDITIONAL MODELS COVERED UNDER THIS REPORT

FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page C2 ADDITIONAL MODELS COVERED UNDER THIS REPORT USED FOR THE PRIMARY TEST S/N: N/A No additional models were covered under this report.

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D1 APPENDI D DIAGRAMS, CHARTS, AND PHOTOS

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D2 FIGURE 1: CONDUCTED EMISSIONS TEST SETUP EUT 80 cm away from the LISNs. Rear of table 40 cm from wall. SCREEN ROOM WALL Wooden Test Bench (1x1.5 meters) ACC EUT ACC LISN EUT LISN 80 cm TO SPECTRUM ANALYZER ACCESSORY POWER EUT POWER

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D3 FIGURE 2: PLOT MAP AND LAYOUT OF RADIATED SITE 3 METERS OPEN LAND > 15 METERS OPEN LAND > 15 METERS D/2 D 3 OPEN AREA REQUIRED BY ANSI C63.4 EUT D/2 d = 3 D TEST EQUIPMENT OPEN LAND > 15 METERS = GROUND RODS = GROUND SCREEN D = TEST DISTANCE (meters) = WOOD COVER

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D4 FIGURE 3: PLOT MAP AND LAYOUT OF RADIATED SITE 10 METERS OPEN LAND > 15 METERS OPEN LAND > 15 METERS D/2 D 10 OPEN AREA REQUIRED BY ANSI C63.4 EUT D/2 d = 10 D TEST EQUIPMENT OPEN LAND > 15 METERS = GROUND RODS = GROUND SCREEN D = TEST DISTANCE (meters) = WOOD COVER

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D5 COM-POWER AB-900 BICONICAL ANTENNA S/N: 15250 CALIBRATION DATE: FEBRUARY 23, 2009 FREQUENCY (MHz) FACTOR (db) FREQUENCY (MHz) 30 13.0 100 11.1 35 11.1 120 13.6 40 10.2 140 12.4 45 11.2 160 12.9 50 11.6 180 16.5 60 9.1 200 17.0 70 8.4 250 16.3 80 6.2 275 18.2 90 8.5 300 17.9 FACTOR (db)

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D6 COM-POWER AL-100 LOG PERIODIC ANTENNA S/N: 16060 CALIBRATION DATE: JUNE 15, 2009 FREQUENCY (MHz) FACTOR (db) FREQUENCY (MHz) 300 14.2 700 20.1 400 15.9 800 21.2 500 17.1 900 21.3 600 18.8 1000 22.3 FACTOR (db)

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D7 COM POWER AH-118 HORN ANTENNA S/N: 071175 CALIBRATION DATE: JUNE 27, 2008 FREQUENCY (GHz) FACTOR (db) FREQUENCY (GHz) 1.0 24.5 10.0 39.4 1.5 25.4 10.5 39.7 2.0 28.3 11.0 39.0 2.5 28.9 11.5 40.0 3.0 29.7 12.0 39.7 3.5 30.8 12.5 41.7 4.0 31.4 13.0 42.7 4.5 32.6 13.5 41.2 5.0 33.7 14.0 41.6 5.5 34.4 14.5 43.2 6.0 34.7 15.0 42.3 6.5 35.4 15.5 39.3 7.0 37.0 16.0 41.7 7.5 37.4 16.5 39.6 8.0 37.6 17.0 43.0 8.5 37.6 17.5 47.1 9.0 38.5 18.0 46.2 9.5 38.6 FACTOR (db)

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D8 COM-POWER PA-102 PREAMPLIFIER S/N: 1017 CALIBRATION DATE: JANUARY 12, 2009 FREQUENCY (MHz) FACTOR (db) FREQUENCY (MHz) 30 39.0 300 38.8 40 39.0 350 38.8 50 38.8 400 38.7 60 38.7 450 38.6 70 38.8 500 38.3 80 38.8 550 38.9 90 39.1 600 38.4 100 39.1 650 38.8 125 38.9 700 38.4 150 38.9 750 38.5 175 38.9 800 38.3 200 38.8 850 38.4 225 39.0 900 38.1 250 38.9 950 37.4 275 38.8 1000 38.1 FACTOR (db)

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D9 COM-POWER PA-122 PREAMPLIFIER S/N: 181921 CALIBRATION DATE: MARCH 12, 2009 FREQUENCY (GHz) FACTOR (db) FREQUENCY (GHz) FACTOR (db) 1.0 36.46 10.0 35.06 1.5 35.36 10.5 34.82 2.0 34.76 11.0 33.12 2.5 34.94 11.5 34.33 3.0 34.59 12.0 34.75 3.5 34.55 12.5 33.94 4.0 34.25 13.0 35.50 4.5 33.89 13.5 34.89 5.0 34.22 14.0 36.56 5.5 34.81 14.5 36.06 6.0 35.74 15.0 36.67 6.5 36.51 15.5 36.84 7.0 36.66 16.0 34.31 7.5 35.72 16.5 35.11 8.0 33.28 17.0 35.35 8.5 33.11 17.5 34.11 9.0 34.71 18.0 33.88 9.5 35.50 18.5 32.20

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D10 COM-POWER AL-130 LOOP ANTENNA S/N: 17089 CALIBRATION DATE: SEPTEMBER 29, 2008 FREQUENCY (MHz) MAGNETIC (db/m) 0.009-41.57 9.93 0.01-42.06 9.44 0.02-42.43 9.07 0.05-42.50 9.00 0.07-42.10 9.40 0.1-42.03 9.47 0.2-44.50 7.00 0.3-41.93 9.57 0.5-41.90 9.60 0.7-41.73 9.77 1-41.23 10.27 2-40.90 10.60 3-41.20 10.30 4-41.30 10.20 5-40.70 10.80 10-41.10 10.40 15-42.17 9.33 20-42.00 9.50 25-42.20 9.30 30-43.10 8.40 ELECTRIC (db/m)

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D11 FRONT VIEW FOPRO, INC. TRANSMITTER MODEL: T24 FCC SUBPART B AND C TRANSMIT MODE RADIATED EMISSIONS PHOTOGRAPH SHOWING THE EUT CONFIGURATION FOR MAIMUM EMISSIONS

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D12 REAR VIEW FOPRO, INC. TRANSMITTER MODEL: T24 FCC SUBPART B AND C TRANSMIT MODE RADIATED EMISSIONS PHOTOGRAPH SHOWING THE EUT CONFIGURATION FOR MAIMUM EMISSIONS

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D13 FRONT VIEW FOPRO, INC. TRANSMITTER MODEL: T24 FCC SUBPART B DATA TRANSFER MODE RADIATED EMISSIONS PHOTOGRAPH SHOWING THE EUT CONFIGURATION FOR MAIMUM EMISSIONS

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page D14 REAR VIEW FOPRO, INC. TRANSMITTER MODEL: T24 FCC SUBPART B DATA TRANSFER MODE RADIATED EMISSIONS PHOTOGRAPH SHOWING THE EUT CONFIGURATION FOR MAIMUM EMISSIONS

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page E1 APPENDI E DATA SHEETS

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page E2 RADIATED EMISISONS DATA SHEETS

FCC 15.231 Foxpro, Inc. Date: 08/11/09 Labs: B and D Tested By: Kyle Fujimoto -Axis - Transmit Mode Freq. (MHz) Level (dbuv) Pol (v/h) Limit Margin Peak / QP / Avg Ant. Height (m) Table Angle (deg) 433.92 74.26 V 100.28-26.02 Peak 2.05 135 433.92 63.82 V 80.28-16.46 Avg 2.05 135 Comments 867.84 39.48 V 80.28-40.8 Peak 1.05 135 867.84 29.04 V 60.28-31.24 Avg 1.05 135 1301.76 47.06 V 74-26.94 Peak 1.25 150 1301.76 36.62 V 54-17.38 Avg 1.25 150 1735.68 49.01 V 74-24.99 Peak 1.35 150 1735.68 38.57 V 54-15.43 Avg 1.35 150 2169.6 45.82 V 74-28.18 Peak 1.55 175 2169.6 35.38 V 54-18.62 Avg 1.55 175 2603.52 47.75 V 74-26.25 Peak 1.25 150 2603.52 37.31 V 54-16.69 Avg 1.25 150 3037.44 52.13 V 74-21.87 Peak 1.55 175 3037.44 41.69 V 54-12.31 Avg 1.55 175 3471.36 48.35 V 74-25.65 Peak 1.28 190 3471.36 37.91 V 54-16.09 Avg 1.28 190 3905.28 41.04 V 74-32.96 Peak 1.69 125 3905.28 30.6 V 54-23.4 Avg 1.69 125 4339.2 41.57 V 74-32.43 Peak 1.58 125 4339.2 31.13 V 54-22.87 Avg 1.58 125

FCC 15.231 Foxpro, Inc. Date: 08/11/09 Labs: B and D Tested By: Kyle Fujimoto -Axis - Transmit Mode Freq. (MHz) Level (dbuv) Pol (v/h) Limit Margin Peak / QP / Avg Ant. Height (m) Table Angle (deg) 433.92 89.21 H 100.28-11.07 Peak 1 90 433.92 78.77 H 80.28-1.51 Avg 1 90 Comments 867.84 48.74 H 80.28-31.54 Peak 1.25 90 867.84 38.3 H 60.28-21.98 Avg 1.25 90 1301.76 43.22 H 74-30.78 Peak 1.45 315 1301.76 32.78 H 54-21.22 Avg 1.45 315 1735.68 40.83 H 74-33.17 Peak 1.55 135 1735.68 30.39 H 54-23.61 Avg 1.55 135 2169.6 43.65 H 74-30.35 Peak 1.35 150 2169.6 33.21 H 54-20.79 Avg 1.35 150 2603.52 45.31 H 74-28.69 Peak 1.55 180 2603.52 34.87 H 54-19.13 Avg 1.55 180 3037.44 44.18 H 74-29.82 Peak 1.56 135 3037.44 33.74 H 54-20.26 Avg 1.56 135 3471.36 44.61 H 74-29.39 Peak 1.56 135 3471.36 34.17 H 54-19.83 Avg 1.56 135 3905.28 42.32 H 74-31.68 Peak 1.58 160 3905.28 31.88 H 54-22.12 Avg 1.58 160 4339.2 42.93 H 74-31.07 Peak 1.59 135 4339.2 32.49 H 54-21.51 Avg 1.59 135

FCC 15.231 Foxpro, Inc. Date: 08/11/09 Labs: B and D Tested By: Kyle Fujimoto Y-Axis - Transmit Mode Freq. (MHz) Level (dbuv) Pol (v/h) Limit Margin Peak / QP / Avg Ant. Height (m) Table Angle (deg) 433.92 84.35 V 100.28-15.93 Peak 1.35 90 433.92 73.91 V 80.28-6.37 Avg 1.35 90 Comments 867.84 43.29 V 80.28-36.99 Peak 1.25 135 867.84 32.85 V 60.28-27.43 Avg 1.25 135 1301.76 45.26 V 74-28.74 Peak 1.58 125 1301.76 34.82 V 54-19.18 Avg 1.58 125 1735.68 47.88 V 74-26.12 Peak 1.59 135 1735.68 37.44 V 54-16.56 Avg 1.59 135 2169.6 44.71 V 74-29.29 Peak 1.95 150 2169.6 34.27 V 54-19.73 Avg 1.95 150 2603.52 48.37 V 74-25.63 Peak 1.25 45 2603.52 37.93 V 54-16.07 Avg 1.25 45 3037.44 49.85 V 74-24.15 Peak 1.58 135 3037.44 39.41 V 54-14.59 Avg 1.58 135 3471.36 49.85 V 74-24.15 Peak 1.59 225 3471.36 39.41 V 54-14.59 Avg 1.59 225 3905.28 43.26 V 74-30.74 Peak 1.69 275 3905.28 32.82 V 54-21.18 Avg 1.69 275 4339.2 42.07 V 74-31.93 Peak 1.58 225 4339.2 31.63 V 54-22.37 Avg 1.58 225

FCC 15.231 Foxpro, Inc. Date: 08/11/09 Labs: B and D Tested By: Kyle Fujimoto Y-Axis - Transmit Mode Freq. (MHz) Level (dbuv) Pol (v/h) Limit Margin Peak / QP / Avg Ant. Height (m) Table Angle (deg) 433.92 75.02 H 100.28-25.26 Peak 1.35 225 433.92 64.58 H 80.28-15.7 Avg 1.35 225 Comments 867.84 39.58 H 80.28-40.7 Peak 1 45 867.84 29.14 H 60.28-31.14 Avg 1 45 1301.76 42.56 H 74-31.44 Peak 1.25 135 1301.76 32.12 H 54-21.88 Avg 1.25 135 1735.68 47.04 H 74-26.96 Peak 1.25 150 1735.68 36.6 H 54-17.4 Avg 1.25 150 2169.6 45.91 H 74-28.09 Peak 1.35 155 2169.6 35.47 H 54-18.53 Avg 1.35 155 2603.52 52.67 H 74-21.33 Peak 1.35 150 2603.52 42.23 H 54-11.77 Avg 1.35 150 3037.44 52.91 H 74-21.09 Peak 1.55 165 3037.44 42.47 H 54-11.53 Avg 1.55 165 3471.36 50.37 H 74-23.63 Peak 1.35 150 3471.36 39.93 H 54-14.07 Avg 1.35 150 3905.28 42.64 H 74-31.36 Peak 1.28 150 3905.28 32.2 H 54-21.8 Avg 1.28 150 4339.2 41.52 H 74-32.48 Peak 1.35 135 4339.2 31.08 H 54-22.92 Avg 1.35 135

FCC 15.231 Foxpro, Inc. Date: 08/11/09 Labs: B and D Tested By: Kyle Fujimoto Z-Axis - Transmit Mode Freq. (MHz) Level (dbuv) Pol (v/h) Limit Margin Peak / QP / Avg Ant. Height (m) Table Angle (deg) 433.92 77.82 V 100.28-22.46 Peak 1.35 135 433.92 67.38 V 80.28-12.9 Avg 1.35 135 Comments 867.84 40.44 V 80.28-39.84 Peak 1.35 135 867.84 30 V 60.28-30.28 Avg 1.35 135 1301.76 45.73 V 74-28.27 Peak 1.58 150 1301.76 35.29 V 54-18.71 Avg 1.58 150 1735.68 46.02 V 74-27.98 Peak 1.59 180 1735.68 35.58 V 54-18.42 Avg 1.59 180 2169.6 41.91 V 74-32.09 Peak 1.58 195 2169.6 31.47 V 54-22.53 Avg 1.58 195 2603.52 51.62 V 74-22.38 Peak 1.59 205 2603.52 41.18 V 54-12.82 Avg 1.59 205 3037.44 49.46 V 74-24.54 Peak 1.65 150 3037.44 39.02 V 54-14.98 Avg 1.65 150 3471.36 48.14 V 74-25.86 Peak 1.58 135 3471.36 37.7 V 54-16.3 Avg 1.58 135 3905.28 38.78 V 74-35.22 Peak 1.25 180 3905.28 28.34 V 54-25.66 Avg 1.25 180 4339.2 41.89 V 74-32.11 Peak 1.35 175 4339.2 31.45 V 54-22.55 Avg 1.35 175

FCC 15.231 Foxpro, Inc. Date: 08/11/09 Labs: B and D Tested By: Kyle Fujimoto Z-Axis - Transmit Mode Freq. (MHz) Level (dbuv) Pol (v/h) Limit Margin Peak / QP / Avg Ant. Height (m) Table Angle (deg) 433.92 87.35 H 100.28-12.93 Peak 1.25 135 433.92 76.91 H 80.28-3.37 Avg 1.25 135 Comments 867.84 47.37 H 80.28-32.91 Peak 1.35 150 867.84 36.93 H 60.28-23.35 Avg 1.35 150 1301.76 45.35 H 74-28.65 Peak 1.58 150 1301.76 34.91 H 54-19.09 Avg 1.58 150 1735.68 49.03 H 74-24.97 Peak 1.36 150 1735.68 38.59 H 54-15.41 Avg 1.36 150 2169.6 45.88 H 74-28.12 Peak 1.58 135 2169.6 35.44 H 54-18.56 Avg 1.58 135 2603.52 47.43 H 74-26.57 Peak 1.59 225 2603.52 36.99 H 54-17.01 Avg 1.59 225 3037.44 45.81 H 74-28.19 Peak 1.35 150 3037.44 35.37 H 54-18.63 Avg 1.35 150 3471.36 44.37 H 74-29.63 Peak 1.25 150 3471.36 33.93 H 54-20.07 Avg 1.25 150 3905.28 40.11 H 74-33.89 Peak 1.58 155 3905.28 29.67 H 54-24.33 Avg 1.58 155 4339.2 43.81 H 74-30.19 Peak 1.36 155 4339.2 33.37 H 54-20.63 Avg 1.36 155

EN 55022 Class B and ICES-003 Foxpro, Inc. Date: 08/12/09 Labs: B and D Tested By: Kyle Fujimoto Data Transfer Mode - Tested at 10 Meters - Test Range: 30 MHz to 1000 MHz Vertical and Horizontal Polarizations Freq. (MHz) Level (dbuv) Pol (v/h) Limit Margin Peak / QP / Avg Ant. Height (m) Table Angle (deg) 432.07 15.11 V 37-21.89 Peak 1.15 180 508.11 22.15 V 37-14.85 Peak 1.15 0 537.27 17.99 V 37-19.01 Peak 1.15 0 623.44 19.78 V 37-17.22 Peak 1.15 0 670.54 25.33 V 37-11.67 Peak 1.15 0 Comments 400.95 20.26 H 37-16.74 Peak 1.15 180 418.13 13.46 H 37-23.54 Peak 1.35 155 483.76 22.23 H 37-14.77 Peak 1.25 180 549.19 23.01 H 37-13.99 Peak 1.25 180 623.74 25.19 H 37-11.81 Peak 1.25 180

FCC 15.249 Foxpro, Inc. Date: 08/11/09 Labs: B and D Tested By: Kyle Fujimoto Non-Harmonic Emissions From the and Digital Portion in Transmit Mode Freq. (MHz) Level (dbuv) Pol (v/h) Limit Margin Peak / QP / Avg Ant. Height (m) Table Angle (deg) Comments No Non-Harmonic Emissions Found for the EUT from 10 khz to 1 GHz for both Vertical and Horizontal Polarizations No Emissions Found for the EUT from 10 khz to 1 GHZ for both Vertical and Horizontal Polarizations For the Digital Portion in Transmit Mode

FCC Part 15 Subpart B and FCC Section 15.249 Test Report Page E11-20 db BANDWIDTH DATA SHEETS

Ref Lvl 92 db V 92 80 70 60 D1 65.81 db V 1VIEW 2VIEW Delta 1 [T2] -0.60 db 126.25250501 khz 1 2 RBW 30 khz RF Att 10 db VBW 100 khz SWT 5.5 ms Unit db V 1 [T2] 65.33 db V A 433.85186373 MHz 1 [T2] -0.60 db 126.25250501 khz 2 [T2] 85.81 db V 1 433.91599198 MHz IN1 1AP 2MA 50 40 P0 TDS 30 20 10 0-8 Center 433.91499 MHz Date: 10.AUG.2009 11:53:17 100 khz/ F1 Span 1 MHz -20 db Bandwidth of the Fundamental