ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

Similar documents
ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

References 1 for asynchronous motors 1

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

Electronic timer CT-SDD.22

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

RE17LLBM asymmetrical flashing relay s V AC - solid state output

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Electronic timer CT-SDS.22

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-TGD.22

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Protection components

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

Zelio Control Measurement Relays

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

VW3A4556 line choke mh A - 3 phases W - for variable speed drive

RENF22R2MMW Zelio Timer Relay - Modular

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Three-phase monitoring relays

08/07/2015

ATV12H018M3 frekv.pretvarač promj.brzine ATV12 0,18 KW 0,25 ks V 3 faze

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Three-phase monitoring relay CM-PFS

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relays CM-PFE and CM-PFE.2

02/11/2015

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Power supply CP-D 24/1.3

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

22/10/2012

Three-phase monitoring relay

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

02/11/2015

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Electronic timer CT-MFS.21

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

08/07/2015

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

Power supply CP-E 24/2.5

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Power supply CP-E 24/20.0

CP-T range Product group picture

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Subject to changes 11/2003 Page 1/7

ZBRT2 double actions (up/down) transmitter for wireless and battery less pushbutton

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Power supply CP-D 24/4.2 Primary switch mode power supply

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

CP-T range Benefits and advantages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

02/11/2015

Transcription:

Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device short name Network number of phases Mar 09, 2017 Soft starter Asynchronous motors Simple machine ATS01 1 phase [Us] rated supply voltage 110...480 V - 10...10 % Motor power kw Motor power hp IcL starter rating 11 kw 3 phases 400 V 3 kw 3 phases 230 V 4 kw 3 phases 230 V 9 kw 3 phases 400 V 7.5 kw 3 phases 400 V 5.5 kw 3 phases 230 V 2.2 kw 1 phase 230 V 11 hp 3 phases 460 V 2 hp 3 phases 210 V 3 hp 3 phases 210 V 5 hp 3 phases 230 V 9 hp 3 phases 460 V 7.5 hp 3 phases 230 V 25 A Utilisation category AC-53B EN/IEC 60947-4-2 Current consumption Type of start Power dissipation in W Complementary Assembly style Function available Supply voltage limits 125 A at nominal load Start with voltage ramp 1 W at full load and at end of starting 126 W in transient state With heat sink Integrated bypass 99...528 V 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Supply frequency 50...60 Hz - 5...5 % Network frequency Output voltage Control circuit voltage 47.5...63 Hz <= power supply voltage 24 V AC/DC +/- 10 % 30 ma 110 V AC +/- 10 % 35 ma 240 V AC +/- 10 % 80 ma Starting time 1 s 100 5 s 20 Adjustable from 1 to 5 s Starting torque Discrete output current Tightening torque Electrical connection Marking Operating position Height Width Depth Product weight Compatibility code Motor power range AC-3 Motor starter type 30...80 % of starting torque of motor connected directly on the line supply 2 A DC-13 3 A AC-15 1.9...2.5 N.m 0.5 N.m 4 mm screw clamp terminal rigid 1 1...10 mm² AWG 8 power circuit Screw connector rigid 1 0.5...2.5 mm² AWG 14 control circuit 4 mm screw clamp terminal rigid 2 1...6 mm² AWG 10 power circuit Screw connector rigid 2 0.5...1 mm² AWG 17 control circuit Screw connector flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit 4 mm screw clamp terminal flexible without cable end 1 1.5...10 mm² AWG 8 power circuit Screw connector flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit 4 mm screw clamp terminal flexible with cable end 2 1...6 mm² AWG 10 power circuit 4 mm screw clamp terminal flexible without cable end 2 1.5...6 mm² AWG 10 power circuit Screw connector flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit CE Vertical +/- 10 degree 124 mm 45 mm 131 mm 0.35 kg ATS01N1 7...11 kw at 380...440 V 3 phases 7...11 kw at 200...240 V 3 phases 4...6 kw at 200...240 V 3 phases 2.2...3 kw at 200...240 V 1 phase 2.2...3 kw at 200...240 V 3 phases Soft starter Environment Electromagnetic compatibility Damped oscillating waves level 3 IEC 61000-4-12 Electrostatic discharge level 3 IEC 61000-4-2 Immunity to electrical transients level 4 IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 Voltage/Current impulse level 3 IEC 61000-4-5 Conducted and radiated emissions level B CISPR 11 Conducted and radiated emissions level B IEC 60947-4-2 EMC immunity EN 50082-2 Harmonics IEC 1000-3-2 Harmonics IEC 1000-3-4 Immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6 Micro-cuts and voltage fluctuation IEC 61000-4-11 EMC immunity EN 50082-1 Standards EN/IEC 60947-4-2 Product certifications IP degree of protection GOST B44.1-96/ASME A17.5 for starter wired to the motor delta terminal CSA UL C-Tick CCC IP20 Pollution degree 2 EN/IEC 60947-4-2 Vibration resistance 1.5 mm peak to peak 3...13 Hz EN/IEC 60068-2-6 1 gn 13...150 Hz EN/IEC 60068-2-6 Shock resistance 15 gn 11 ms EN/IEC 60068-2-27 2

Relative humidity 5...95 % without condensation or dripping water EN/IEC 60068-2-3 Ambient air temperature for operation -10...40 C without derating 40...50 C with current derating of 2 % per C Ambient air temperature for storage -25...70 C EN/IEC 60947-4-2 Operating altitude <= 1000 m without derating > 1000 m with current derating of 2.2 % per additional 100 m Contractual warranty Warranty period 18 months 3

Dimensions Drawings Dimensions Mounting on Symetrical (35 mm) Rail Screw Fixing (1) Retractable fixings 4

Connections and Schema Example of 3-phase Power Supply Connection (1) A line contactor must be used in the sequence. A1 : Soft starter Q1 : Motor circuit-breaker KM1 :Contactors F1, F2 Control : protection fuses S1, S2 Pushbuttons : 5

Technical Description Function Diagram Us : Power supply voltage Uc : Control supply voltage LED 1 Green : LED LED 2 Yellow : LED Um : Motor voltage 6