Powered by TCPDF (

Similar documents
Stability of electromagnetic flowmeter. Sub Title. 堀内, 敏夫 (Horiuchi, Toshio B.) 柴田, 利幸 (Shibata, Toshiyuki) 慶応義塾大学藤原記念工学部. Publication year 1959

VIBRATIONS LEVEL ANALYSIS DURING THE OPERATION OF A HIGH HEAD HYDROPOWER PLANT

Waves Q1. MockTime.com. (c) speed of propagation = 5 (d) period π/15 Ans: (c)

Hydro-acoustic resonance behavior in presence of a precessing vortex rope: observation of a

Borehole vibration response to hydraulic fracture pressure

Generator type: Synchronous salient poles Vertical axis Nr. poles: 12 PD² rotor : kgm². Turbine elevation: m.a.s.l.

Mode Dispersion Curves

RESEARCH PAPERS FACULTY OF MATERIALS SCIENCE AND TECHNOLOGY IN TRNAVA, SLOVAK UNIVERSITY OF TECHNOLOGY IN BRATISLAVA, 2016 Volume 24, Number 39

SECTION A Waves and Sound

Vertical-Vibration Suppressing Design of Accumulator with New Vibration-Measuring Method

Fundamental study of subharmonic vibration of order 1/2 in automatic transmissions for cars

CHAPTER 7 FAULT DIAGNOSIS OF CENTRIFUGAL PUMP AND IMPLEMENTATION OF ACTIVELY TUNED DYNAMIC VIBRATION ABSORBER IN PIPING APPLICATION

SECTION A Waves and Sound

Statistic evaluation of deviation between guaranteed and measured turbine efficiency

Control and Signal Processing in a Structural Laboratory

Presented at the 109th Convention 2000 September Los Angeles, California, USA

1. Introduction. 2. Concept. reflector. transduce r. node. Kraftmessung an verschiedenen Fluiden in akustischen Feldern

Waves and Sound Practice Test 43 points total Free- response part: [27 points]

Vertex Detector Mechanics

Examination of Microphonic Effects in SRF Cavities

Experimental Investigation of Unsteady Pressure on an Axial Compressor Rotor Blade Surface

Construction of Steel Penstocks using HT100 at Kannagawa Hydropower Plant

LORENTZ FORCE DETUNING ANALYSIS OF THE SPALLATION NEUTRON SOURCE (SNS) ACCELERATING CAVITIES *

Physics 1C. Lecture 14C. "The finest words in the world are only vain sounds if you cannot understand them." --Anatole France

Vibration based condition monitoring of rotating machinery

Design of a System to Control the Noise of Dry Fluid Coolers

A Narrow-Band Tunable Diode Laser System with Grating Feedback

WAVES. Chapter Fifteen MCQ I

GROUPCODE NEN : ANSI : STEEL BS : STEEL

Part I. Open Open Pipes. A 35 cm long string is played at its fundamental frequency.

(a) What is the tension in the rope? (b) With what frequency must the rope vibrate to create a traveling wave with a wavelength of 2m?

A detailed experimental modal analysis of a clamped circular plate

Vertical-Vibration Suppressing Design of Accumulator with New Vibration-Measuring Method

Analysis of Power Oscillations and Their Treatment in Hydro Power Plant with Large Bulb Turbines

MAGNETRON DEVELOPMENT. R.R.Moats

application of design automation to reduce cycle time of hydro turbine design

ABC Math Student Copy

Rotordynamics Analysis Overview

Natural frequencies of rotating disk-like structures submerged viewed from the stationary frame

Effect of Braces on Framed Machine Foundation for Turbo Generator

Studies on free vibration of FRP aircraft Instruments panel boards

Technical Approach for Preventing Thermal Distortion in Machine Tools

Design of Barrier to Control the Noise of Fin Tube Heat Exchangers

Tyre Cavity Coupling Resonance and Countermeasures Zamri Mohamed 1,a, Laith Egab 2,b and Xu Wang 2,c

Monopile as Part of Aeroelastic Wind Turbine Simulation Code

ENHANCEMENT OF THE TRANSMISSION LOSS OF DOUBLE PANELS BY MEANS OF ACTIVELY CONTROLLING THE CAVITY SOUND FIELD

Numerical Study of a High Head Francis Turbine with Measurements from the Francis-99 Project

Introduction*to*Machinery*Vibration*Sheet*Answer* Chapter*1:*Vibrations*Sources*and*Uses*

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Status of Coil Structural Design and Magnetic-Structural Analysis

Rev F. Nov 16, /16/2008 Rev F

Surface Vibration Measurement on Rotating Components

Development of Variable Rate Spring by Permanent Magnet with Flux Concentration Method

Advanced Measurements

Silent Transformers to Help Consolidated Edison Meet New York City s Ultrastrict Noise Ordinances

MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START

RELIABILITY WEEKLY 2 MACHINE RESONANCE & VIBRATIONS

Side. Channel Blower APEX DARGANG MACHINERY CORPORATION

Influence of Vibration of Tail Platform of Hydropower Station on Transformer Performance

Preliminary study of the vibration displacement measurement by using strain gauge

Thrusters. Dynamics of Propeller Blade and Duct Loading on Ventilated Thrusters in Dynamic Positioning Mode

CHAPTER 6 INTRODUCTION TO SYSTEM IDENTIFICATION

Experimental study on moonpool resonance of offshore floating structure

Influence of the vibro-acoustic sensor position on cavitation detection in a Kaplan turbine

Quantitative Crack Depth Study in Homogeneous Plates Using Simulated Lamb Waves.

machine design, Vol.6(2014) No.2, ISSN pp

Oscillations. Waves. Sound. Stationary waves. Acoustics of Buildings

Lab 11. Vibrating Strings

An Introduction to Time Waveform Analysis

Analytical and Experimental Investigation of a Tuned Undamped Dynamic Vibration Absorber in Torsion

Waves and Sound. Review 10

Foundations Subjected to Vibration Loads

AORC Technical meeting 2014

Planners Perspective on Series Compensated Transmission Lines

NUMERICAL COMPARISON OF ACTIVE ACOUSTIC AND STRUCTURAL NOISE CONTROL IN A STIFFENED DOUBLE WALL CYLINDER

Acoustic Yagi Uda Antenna Using Resonance Tubes

Innovative laboratory equipment. Preliminary testing to determine the mix quality.

LTS(3-terminal type self-oscillation formula) series TSP(2-terminal type separate excitation oscillation formula) series

Objectives. Applications Of Waves and Vibrations. Main Ideas

FLUTTER CONTROL OF WIND TUNNEL MODEL USING A SINGLE ELEMENT OF PIEZO-CERAMIC ACTUATOR

Development of a Vibration Measurement Method for Cryocoolers

[4] (b) Fig. 6.1 shows a loudspeaker fixed near the end of a tube of length 0.6 m. tube m 0.4 m 0.6 m. Fig. 6.

of bamboo. notes. in the D4. learning to. amplitudes and. pipe. The the.5% to. each. individual. 2% range.

Please refer to the figure on the following page which shows the relationship between sound fields.

Vibration Certification Case Studies Vertical Pump Machinery Controlled with Variable Frequency Drives

MICROWAVE & RF RADIATION: (RFR Information - Technology Newsletter, Full Version)

MOCCASIN THIRD PENSTOCK ADDITION: INCREASING POWER BY REDUCING HEADLOSSES

A study of Vibration Analysis for Gearbox Casing Using Finite Element Analysis

CHAPTER 5 FAULT DIAGNOSIS OF ROTATING SHAFT WITH SHAFT MISALIGNMENT

Name: Date: Period: IB Physics SL Y2 Option A (Sight and Wave Phenomena Part 1) Midterm Exam Study Guide Exam Date: Thursday, March 12, 2015

Chapter 9: Wave Interactions

Fundamentals of Vibration Measurement and Analysis Explained

Natural Frequency Measurement

Statistical analysis of low frequency vibrations in variable speed wind turbines

26 Sep. 10 PHYS102 2

Circuit protection elements

Lab 12. Vibrating Strings

Introduction to Measurement Systems

Identification and Reduction of Noise in a Scroll Compressor

Experimental and theoretical investigation of edge waves propagation and scattering in a thick plate with surface-breaking crack-like defect

Transcription:

Powered by TCPDF (www.tcpdf.org) Title Report on the investigations of vibration of penstocks of hydro-electric power plants Sub Title Author 鬼頭, 史城 (Kito, Fumiki) Publisher 慶應義塾大学藤原記念工学部 Publication year 1950 Jtitle Proceedings of the Fujihara Memorial Faculty of Engineering Keio University Vol.3, No.11 (1950. ),p.95(5)- 102(12) Abstract During the past two years, the Author has made investigations on vibration of penstocks of several hydro-electric power plants. n this paper, abridged report on the result of this study is given. Also, comparison between observed values of freq. of vibration and theoretical values of natural freq. of vibration is made. Notes Genre Departmental Bulletin Paper URL http://koara.lib.keio.ac.jp/xoonips/modules/xoonips/detail.php?koara_id=ko50001004-00030011 -0005

Report on the nvestigations of Vibration of Penstocks of Hydro-Electric Power Plants (Received June 12, 1952) Abstract Fumiki KTO* During the past two years, the Author has made investigations on vibration of penstocks of several hydro-electric power plants. n this paper, abridged report on the result of this study is given. Also, comparison between observed values of freq. of vibration and theoretical values of natural freq. of vibration is made.. ntroduction During the past two years the Author has made investigations on vibration of penstocks of several hydro-electric power plants. Some of them ha,c; been done as a part of work of water-turbine research committee of Society of Mechanical Engineers Japan, of which the Author is a member of the committee. The rest was done by the Author in responce to the request of Electric Power Companies. On the other hand, the Author has made a theoretical study on vibration of penstocks and has obtained a formula giving natural frequency of penstock, in which the effect of hydro-static pressure and the effect of virtual mass of water contained inside the penstock is taken into account, together with the elasticity of t]le pipe wall. n what follows, comparison between the observed value of frequency of vibration with theoretical natural frequency, together with some considerations about the cause of vibrations, will be given.. General nformations about Hydro-electric Power Plants nvestigated Among more than ten hydro-electric power plants, about which the vibration of penstock has been investigated, the five plants are here taken up, because vibration of penstocks of these plants has been considered to be in stat~ of resonance. Some items of these power plants are shown in Table 1. Table 1. General hems of power plants about which the investigation was carried out No. Name of power plant River Output kw per unit No. of rev. /min. Head m 1 kezirigawa keziri Delivery 2.4 m 3 /sec. 900/750 85 2 Utsuno Fuzi 1800 450/37.5 30 * Dr. Eng., Prof. at Keio University ( 5 )

96 Fumiki KTO 3 Ohma Ohi 8600 360/300 78 4 Miho Tenryu (tributary) 3200 600/500 95 5 Kumanogawa Zinzu No.1 (tributary) 1940 720 102 Generator cycles Type of No. of blades No. of blades Manufacturer of sec. water turbine of runner of guide vanes water turbine 60/50 60/50 60/50 60/50 60 Horiz. shaft pumping up Horiz. Frontal Vertical Francis Horiz. Francis Horiz. Francis 9 10 D 14 14 B 15 20 D 15 16 H 15 16 H General items of penstocks of these power plants are as shown in Table 2. The values in this table refer to that part of the penstock where the vibration was most prominent and observation was made. The span length is the length of that part of the penstock measured from one anchor block to the next anchor block. The mean head means the mean value of the hydro-static head of that one span of the penstock. Table 2. General items of the penstocks investigated No. Mean dia. m. Wall thickness mm. Mean head m. Span length m. General location 1 1.50 6.0 18 38 Uppermost 2 2.27 9.5 9.7 29 Upper part 3 4 2.42 1.49 9.0 9.5 27-30 62 30 45 " Middle lower part 5 0.90 7.0 15 53 Upper part 5a 0.90 12.0 90 23 Lower part. Observed Results Magnitudes of amplitude and frequency of vibration as obtained by our observation are given in Table 3. General arrangements of some penstocks investigat- ( 6 )

nvestigations on Vibration of Penstocks of Hydro-Electric Power Plants 97 ed are shown in Figs. 7 to 9. n Figs. 1 to 6, theoretical values of natural freq. of vibration are shown as graphs, the mean hydro-static head of the penstock being taken as abscicca and the ordinates being taken as freq. of vibration per sec. They were obtained by calculation of the following formula:- where f =frequency per sec. of natural vibration of cylindrical shell r =radius of " " em E= Young's modulus of wall material kgjcm 2 u = Poisson's ratio of " g = gravity const. (9.8 m/sec 2.} n = a whole number, cosn8 giving the mode of vibration K= ;(r) l = length of a span of penstock em YJ = 2~h (1-u 2 ) = peripheral contraction ~ = h 2 /(3r 2 ) h = half the thickness of the wall em c = a factor giving the effect of virtual mass of water contained in the shell _ density of water.!.a _----'!t - density of wall material h n 2 + 1 (a may be taken equal to 1/n, at least for practical purposes.) q = mean pressure (in kg/em 2 ) of hydro-static head of water. Table 3. Observed values of vibration amplitude and frequency Vibration amplitude mm Vibration frequency sec. Vibrometer used 1 2 3 4 5 2 6.7 Cambridge vibrograph 2.0 6.2( at 50 cycles ) 0.2 7.3(at 60 cycles) Hand vibrograph(akashi) 14.0 0.04 140 4.2 180 ( 7 ) Vibrograph for transmisson line use Hand vibrograph Osillograph

98 Fumiki KTO V. Some Remarks on Observed Results The penstock of No. 1 Power Plant, (kezirigawa),. the vibration of which we have investigated, belonged to a pumping-up set of the plant. ts observed no. of vibrations per sec. was different either from the value of (no. of rev./sec. of the impeller) or (no. of rev.fsec. x no. of blades of impeller). t was considered that a kind of surging phenomena occurring inside the pump (the impeller being of twin type) is the source of vibration of the penstock. When pressure wave of vibration comes up rising through the penstock, one span of it at which the freq. of natural vibration is sufficiently near to that of exciting pressure wave, will make severe vibration of resonance state. But in the present case of this plant, at one span whith lies directly below that span making severe vibration, there was felt no conceivable vibration, in spite of the fact that these two spans.had almost the same dimension. On the other hand, making theoretical investigation, it was found out that the natural freq. depend considerably upon the mean static head 0 20 30 Hqdroslatic Head, m. Fig. 1. Vibration freq. for penstock of kezirigawa power station (pumping up plant) of water, together with other quantities. Thus the above mentioned phenomena could be explained, since the two consecutive spans had a difference of altitude of more than 10 m. n the case of No. 2 Power Plant, freq. of vibration of penstock just coincided with no. of rev. per sec, of turbine runner, at 50 cycle operation. Thus the cause of vibration was to be attributed to action of runner of water turbine. ( 8 )

nvestigations on Vibration of Penstocks of Hydro-Electric Power plants 99 This being in a state of resonance, if no. of freq. per sec. of exciting force arising at the runner was possible to,make to change, the state of resonance could be avoided. n order to confirm this inference, 60 cycle operation of this plant was tried. n that case of 60 cycle operation, it was found that no conceivable vibration was felt anywhere at the penstock. (Note: n Japan, there are several power plants which can operate either at 50 or 60 cycles.) Fig. 2. Vibration freq. for penstock of Utsuno power station n the case of No. 3 Power Plant, there appeared tremendous vibration of amplitude amounting to 14 mm. extending to a period of about one month, and after an elapse of that period, the vibration amplitude reduced gradually. The origin of vibration is so~ght in draft. tube of the water tubine, but accurate cause of this phenomenon of tremendous vibration is yet to be investigated. n the case of No. 4 and No. 5 Power Plants, the penstock emitted humming or 10 20 H~drostatt'c Head) m. Observ-ed ~k Values ----.* 30 Fig. 3. Vibration freq. of penstock of Ohma,power station ( 9 ) 10 20 Hydrostatic Head.) -m.

100 Fumiki KTO 0 a ltr- -:to - -~ 6'o- -- -8~ --Too ~tv, f!ydrcsfolic Head, m. Fig. 4. Vibration freq. of penstock of Miho power station booming sound, and the freq. of this sound (that is. of vibration of penstock) coincided with (number of rev./sec. of runner x no. of blades of runner). At No. 5 Plant, when operated at normal freq. of 60 cycles per sec., one part of the penstock emitted the sound, while when operated at 57 cycles per sec., the other one span of the penstock began to emit the sound. n all of the above mentioned five cases, observed freq. of vibration of penstock fairly coincided with the theoretical values of natural freq. of vibration, showing that the state of resonance are nearly occurring. Fig. 5. Vibration freq. of penstock of Kumanogawa No. 1 Power Station (upper part) ( 10 )

nvestigations on Vibration of Penstocks of Hydro-Electric Power Plants 101 This being so, yet such a remarkable amplitude of vibration. ( or.intensity of sound ) as observed by us could not have taken place, if the sources of pressure variation were not sufficiently strong enough. So that the most effective remedy for preventing the vibrations of penstocks of these plants would consist in cancelling the source of pressure variation which originate at some part of the water turbine. But, if this could not be done so effectively, the next preventive is to alter the natural freq. of vibration of the part in question, probably by means Fig. 6.._.v=2 Observed Va~ue) (60 Do Opemtwn \_1 0 50!00 H,~drosta.tic Head., m. Vibration freq. of penstock of Kumanogawa No. 1 Power Station (lower part) of stiffener rings etc. But fuller discussion about these matters is omitted here, the present paper being a report on investgations of some power plants at which the vibration of penstock were remarkable. Fig. 7. Arrangement of penstock of kezirigawa Power Station (pumping-up plant) ( 11 )

102 Fumiki KTO Fig. 8. Arrangement of penstock of Utsuno Power Station Fig. 9. Arrangement of penstock of Kumanogawa No. 1 Power Station ( 12 )