DATA SHEET. Voltmeters and Ammeters,

Similar documents
DATA SHEET. Switchboard instruments,

TCM-2 Thyristor Control Module DATA SHEET

Function. Adjustment. Extra functions included. Modes. Housing

Analogue Meters BQ0x07 series BQ - Moving-coil Panel instruments BQ0107, BQ0207, BQ0307, BQ0407 & BQ0507 1)

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

DATA SHEET Selectable AC transducer TAS-311DG

DATA SHEET Reverse power relays, RMP-121D ANSI code 32

RMV-122D, RMV-132D ANSI

DATA SHEET Differential current relays, RMC-131D ANSI code 87

DEIF A/S. Insulation monitor. Type SIM-Q

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

Protection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB

Transducers for AC measurement. Types TAP, TAQ, TMF, TAA, TAV, TAC. Measurement of: watt, var, frequency, phase angle, voltage, current

Analogue Meters CQ0x07 series

DATA SHEET. Paralleling relays, HAS-111DG ANSI code 25

Automatic synchronising relay

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

EA16, EB16, EA17, EA19

DEIF A/S. User s manual. Read synchroscope type RSQ-3. Precision LED synchronoscope. High immunity to harmonic distortion F (UK)

Installation and start up instructions. Synchroniser type FAS-115DG uni-line H (UK) Synchronisation of generator to busbar

Installation and start up instructions. Synchroniser type FAS-113DG uni-line F (UK) Synchronisation of generator to busbar

Installation/operation instructions. Insulation monitor type SIM-Q/SIM-Q LF D (UK) Measuring range 1...0Mohm or 10...

Analog indicators. 1/2 Regulations and standards. 1/4 Technical descriptions

Product Guide. Analog Panel Meters in thermoplastic cases with slide-in-dials. K Series. with Moving-Coil Movement

Product Guide. Analog Panel Meters in thermoplastic cases with slide-in-dials. K Series. with Moving-Coil Movement

Installation and start up instructions. Paralleling relay type HAS-111DG uni-line G (UK) Synchronisation of generator to busbar

MOVING-IRON METERS EA16, EB16, EA17, EA19, EA12 TYPES

Basic Series Square Panel Meters Features Benefits

Angle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4..

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Summation current transformers, type KSU/SUSK

Installation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure

DEIF A/S. Application note. Generators parallel with mains Multi-line 2 version 2. Application description. Power import control. Power export control

Flexible AC current probes

ANALOGUE PANEL METERS. GMW We make your values visible Basic Series

Analog Panel Meters Preference Program Basic Series Vario Series

General technical data. Pollution degree 2. EMC / shock / vibration Noise emission acc. to EN Electrical safety (applied standards)

27/04/2015

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

Three-phase monitoring relay CM-PFS

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Standard Program Technical Description

RS Pro ENGLISH. Datasheet

CP-T range Benefits and advantages

Price List w.e.f 1st October 2018

[3] MOUNTING DIRECTION

CP-T range Product group picture

LINAX 4000L Continuous-line recorder


High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

RS Pro ENGLISH. Datasheet

Installation / Monitoring Technique

Analog Panel Meters Preference Program Basic Series Vario Series

For Immediate Delivery call KMParts.com at (866)

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply

DEIF A/S. Application Notes. MDR-2 test procedures. Test of current measurement. Test of differential current measurement.

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

QUINT-PS-24DC/24DC/10

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply

Electronic timer CT-SDS.22

Room sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

RISH Ducer E13 3 channel transducer for AC current and voltage

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ROG4K. EM210 energy analyzer current sensor ( A) Benefits. Description

POINTAX 6000L2 Point Recorder

ISOMETER IRDH575. Approvals

SIPLUS SM 1234 ANALOG INPUT/OUTPUT MODULE

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Technical Data Sheet. x1000. kwh R Y B

CP-E range Benefits and advantages

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

48x48. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output

Zelio Control Measurement Relays

SINEAX U 553 Transducer for AC Voltage

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Differential pressure sensors

Liquid level monitoring relay CM-ENS.2x

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Digital Indicator DS 96/24

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

Overcurrent Protection / 7SJ45

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Measuring current transformers of the W, W series

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Transcription:

DATA SHEET Voltmeters and Ammeters, Moving Coil (type ) Q48, Q72, Q96, Q144 90 or 240 pointer Accuracy class 1.5 Exchangeable scale (type x) Document no.: 4921210012S

Application: Moving-coil instruments are intended for installation in panels of power distribution or wherever AC current or AC voltages are to be measured. is applied to measure low power DC signals or AC voltage and current. Type V is a moving coil meter with rectifier applied for R.M.S. measurement of AC currents or AC voltages where low meter consumption is required. 96-x (exchangeable scale), 90 96-c (non-exchangeable scale), 240 96-xc (exchangeable scale), 240 Variants Q48 Q72 Q96 Q144 Moving Coil mm mm mm mm 90 48-x 72-x 96-x 144-x 48-c 72-c 96-c 144-c 240 48-xc 72-xc 96-xc 144-xc - with rectifier 90 V72-x V96-x V144-x V72-c V96-c V144-c - with rectifier 240 V72-xc V96-xc V144-xc Custom variants Options Scale design Measurement Anti-glare glass IP54 from front (incl. rubber gasket) Adjustable red pointer (types Q48-x, Q72-x, Q96-x, Q144-x) (IP52) Other measuring ranges than those stated in this data sheet: ask for availability Optional graphics - Coloured lines (red, green, yellow) - Coloured section (red, yellow, green) - Coloured figures (red, green, yellow) - Application text (black, red, green, yellow) - Single scale with double row of figures - Double scale with 2 rows of figures - Single scale with fine divisions for standard pointer New scale design Suppressed zero (..-x/..-c/-xc: max. 20 %) Zero at centre of scale or the like Integrated adjustment potentiometer (±10 % standard, up to ±50 % on request) Adjusted to accuracy class 1.0 (not possible for type Q48) DEIF A/S Page 2 of 7

technical specifications, moving coil instruments Type: Q48 Q72 Q96 Q144 Scale Linear Burden (voltmeter): 1 ma, R i: 1 kω/v DC Burden (ammeter): 60 mv DC to 0.6 V DC, 4 to 20 ma DC: 1.6 V DC for -x and 1.80 V DC for c at 20 ma DC (electrically suppressed) Standards DIN 43700 type 48-x 72-x 96-x 144-x 48-xc/48-c 72-xc/72-c 96-xc/96-c 144-xc/144-c Size (mm) Measuring range V DC 1) 2) Measuring ranges A DC 1 ma to 600 ma, 4 to 20 ma 3) 1 ma to 600 ma, 4 to 20 ma 3) 1) 2) 1) Standard measuring ranges: 1-1.2-1.5-2 - 2.5-3 - 4-5 - 6-8 and multiples of 10 thereof 2) Safety: Cat. III 300 V max. (515 V ph-ph (300 x 3)) 3) 4 to 20 ma: Electrically suppressed, voltage drop at 20 ma = 1.6 V for -x and 1.80 V for -c/-xc 4) Higher measuring ranges: For use with standard shunt: 60 mv DC or 150 mv DC Supplied with shunt lead, 2 x 1 m 1 mm 2 (0.035 Ω) V technical specifications V, moving coil instruments with rectifier Type: Q72 Q96 Q144 Scale Non-linear Voltmeter 25 to 300 V AC 1) Internal resistance R i: Approx. 1 kω/v AC Ammeter 1 to 600 ma AC Burden Voltage drop: approx. 1.2 V AC Standards DIN 43700 1) Range <50 V AC: Max. 515 V derived from voltages with max. 300 V to earth (300 V cat. III/600 V cat. II) DEIF A/S Page 3 of 7

General technical specifications Instruments are designed according to below mentioned standards Class 1.5 (-10 to 15 to 30 to 55 C) Standards Accuracy ±1.5 % of full scale value (FS) EN 60051 Q48 Q72 Q96 Q144 Sizes: mm mm mm mm DIN 43700 Scale length -x: 41 mm 62 mm 92 mm 135 mm Scale length -xc: 75 mm 113 mm 151 mm 230 mm Bezels Slim bezels DIN 43718 Scale/pointer Standard pointer DIN 43802 Standard: Vertical (90 ±5 ) Other angles: Specify angle to horizontal vertical mounting Mounting angle 60 60 to horizontal (e.g.) DIN 16257 Π horizontal mounting For edgewise instruments only, furthermore specify: Horizontal or vertical scale Measuring ranges Others on request. DIN 43701 Protection Standard version IP54 version * * ) Marked with label: (Housings) From front From rear From front From rear "IP54 from front only when rubber gasket is IP52 IP52 IP54 IP52 mounted" Quadratic Edgewise Quadratic Edgewise (Terminals) IP20 IP00 IP20 IP00 EN 60529 Climate Class HUE, short-term condensing allowed Max. 95 % RH: Max. 30 days per year DIN 40040 Max. 85 % RH: Remaining days Max. 75 % RH: Average per year Temperature -10 to 55 C (nominal) -25 to 60 C (operating) EN 60051-25 to 65 C (storage) Panel influence The accuracy is affected neither by the material nor by the thickness of the panel EN 60051 Shock test 15 g - 6 times - 3 directions 50 g/6 ms 22 g/20 ms IEC 68-2-27, Test: Ea Vibrations 3 to 13.2 Hz: 3 mm GL + LR: Test 1 13.2 to 100 Hz: 1 g DNV: Class A Materials All plastic materials are self-extinguishing UL94 (V0) Safety For detailed information: please see the individual types Pollution deg. 2 Quadratic instruments are supplied with protective cover fitted over terminals EN 61010-1 EMC CE-classified for residential, commercial and light industry plus EN 61000-6-3/4 industrial environment EN 61000-6-1/2 DEIF A/S Page 4 of 7

Dimensional details 1) For range 15 to 40 A = 59 mm 2) Protective cover All dimensions in mm Type A C B Panel cut-out Weight (approx.) 90 instruments Q48-x Q72-x Q96-x Q144-x 240 instruments Q48-xc/c Q72-xc/c Q96-xc/c Q144-xc/c 5.0 8.0 5.0 8.0 42.8 x 48.8 66.5 x 66.5 90 x 90 136 x 136 42.8 x 48.8 66.5 x 66.5 90 x 90 136 x 136 45 x 45 +0.3 68 x 68 +0.4 92 x 92 +0.4 138 x 138 +0.5 45 x 45 +0.3 68 x 68 +0.4 92 x 92 +0.4 138 x 138 +0.5 0.090 kg 0.200 kg 0.210 kg 0.350 kg 0.180 kg 0.220 kg 0.250 kg 0.400 kg Exchange of scale 1) Press cover at top of instrument as shown. 2) Remove scale by means of a suitable tool (for example a screwdriver). 3) After exchange of scale: refit cover (press till it snaps into place). Calibration is not needed. Note: Interrupt signal to terminals before exchanging the scale. DEIF A/S Page 5 of 7

Available variants Item no. Variant no. Variant description 2961010420 01 48-x all measuring inputs, without scale 2961010420 02 48-x all measuring inputs, with standard scale 2961010420 03 48-x measuring input 4 to 20 ma DC with customised scale and anti-glare glass 2961010420 04 48-x with cos phi scale 2961060420 01 48-c/-xc all measuring inputs, without scale 2961060420 02 48-c/-xc all measuring inputs, with standard scale 2961060420 03 48-c/-xc with cos phi scale 2961010720 01 72-x all measuring inputs, without scale (except direct current >5 A DC) 2961010720 02 72-x all measuring inputs, with standard scale (except direct current >5 A DC) 2961010720 03 72-x direct current measurement with standard scale 2961010720 04 72-x with cos phi scale 2961060720 01 72-c/-xc all measuring inputs, without scale (except direct current >5 A) 2961060720 02 72-c/-xc all measuring inputs, with standard scale (except direct current >5 A DC) 2961060720 03 72-c/-xc direct current measurement with standard scale 2961060720 04 72-c/-xc with cos phi scale 2961010920 01 96-x all measuring inputs, without scale (except direct current >5 A DC) 2961010920 02 96-x all measuring inputs, with standard scale (except direct current >5 A DC) 2961010920 03 96-x direct current measurement with standard scale 2961010920 04 96-x measuring input 4 to 20 ma DC with customised scale incl. anti-glare glass 2961010920 05 96-x measuring input 4 to 20 ma DC with customised scale incl. anti-glare glass and red pointer in glass 2961010920 06 96-x with cos phi scale 2961060920 01 96-c/-xc all measuring inputs, without scale (except direct current >5 A DC) 2961060920 02 96-c/-xc all measuring inputs, with standard scale (except direct current >5 A DC) 2961060920 04 96-c/-xc direct current measurement with standard scale 2961060920 05 96-c/-xc with cos phi scale 2961011420 01 144-x all measuring inputs, without scale (except direct current >5 A DC) 2961011420 02 144-x all measuring inputs, with standard scale (except direct current >5 A DC) 2961011420 03 144-x direct current measurement with standard scale 2961011420 06 144-x with cos phi scale 2961061420 01 144-c/-xc all measuring inputs, without scale (except direct current >5 A DC) 2961061420 02 144-c/-xc all measuring inputs, with standard scale (except direct current >5 A DC) 2961061420 03 144-c/-xc direct current measurement with standard scale 2961061420 06 144-c/-xc with cos phi scale DEIF A/S Page 6 of 7

Order specifications Variants: Mandatory information Item no. Type Additional options to the standard variant Variant no. Measuring range Scale Option Option Example: Additional options to the standard Mandatory information variant Item no. Type Variant no. Measuring range Scale Option Option 2961060420-02 48-c 02 0 to 10V DC 0 to 100 % Glass w/red adjustable pointer 2961010920-03 96-x 03 0 to 40 A 0 to 40 A IP54 Disclaimer DEIF A/S reserves the right to change any of the contents of this document without prior notice. The English version of this document always contains the most recent and up-to-date information about the product. DEIF does not take responsibility for the accuracy of translations, and translations might not be updated at the same time as the English document. If there is a discrepancy, the English version prevails. DEIF A/S, Frisenborgvej 33 DK-7800 Skive, Denmark Due to our continuous development we reserve the right to supply equipment which may vary from the described. Tel.: +45 9614 9614, Fax: +45 9614 9615 E-mail: deif@deif.com, URL: www.deif.com