SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

Similar documents
Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

3. Contact Form A: SPST-NO

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

SPST-NO SPDT DPST-NO DPDT

Fluoro plastic housing for highest chemical and detergent resistance

Model Number Structure

CSM_G7S-_-E_DS_E_7_1

SPST-NO SPDT DPST-NO DPDT

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Model Number Structure

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

PCB Footprint Max.Load Coil Voltage Non-Latching part number Single-coil latching part number Standard ground terminal (1GHz)

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

MY-GS CSM_MY-GS_DS_E_2_1

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

Phase-sequence Phase-loss Relay

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Classification Enclosure rating Contact form Contact material

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

Switch Mode Power Supply

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

E8EB-N0C2B E8EB-N0B2B

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Model Number Structure

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Surface-mounting Relay

G8P. PCB Power Relay. Model Number Legend. Application Examples. Ordering Information

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes)

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

Details on the New G2RS

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

G2RL-1A G2RL-1 G2RL-2A G2RL-2

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Contact Ag + Au-clad AgPd + Au-clad. General purpose DPDT G6AU-274P-ST-US G6AU-234P-ST-US 4PDT G6AU-474P-ST-US G6AU-434P-ST-US

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

G5LE. Ordering Information. PCB Relay. A Cubic, Single-pole 10-A Power Relay J MODEL NUMBER LEGEND G5LE PCB Relay G5LE

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

Model Number Structure

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Safety Monitoring Relays

Model Number Structure

G2RV-SL Slim I/O Relay will be discontinued February 2019

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

Solid-state Twin Timer

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Ordering Information. Ratchet Relay G4Q. Model Number Legend

OMRON MK-I / -S RELAY

Single-phase Current Relay

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

CV : 16 A, pinning 5 mm,: switching at 105 C 6. Market Code None : General purpose HA : Home Appliance according to IEC/EN

High switching capacity 1a/1c 30A power relays

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

Tactile Switch. Ordering Information. A Wide Range of Models: 6 6 mm, mm, Side-operated, High-force, and Gold-plated.

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Solid-state Timer H3DS

Single-phase Voltage Relay

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Switch Mode Power Supply

V700-series. Electromagnetic Inductive RFID System. ID Tag. Antenna. Controller

Multipoint Temperature Controller

Technical Information General Purpose Relays

Model Number Structure

Safety Relay Unit. OFF-delay time

Characteristic impedance

General-purpose Relay

RT-3 UNIT RELAY 4-POINT TERMINAL

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Notice for TAIYO YUDEN Products

Transcription:

For Reference Date of Issue: March 17, 2011 OMRON Corporation OMRON RELAY&DEVICES Corporation SPECIFICATIONS This specification sheet is for reference only, Please request it again if a specification for receipt is necessary. Handled by Distribution Copy Customer 1 Sales

[ ] For Receipt [*] For Reference Spec. No.: (1/9) Date of First issue: March 17, 2011 Date of Revised issue: ---------- OMRON Corporation OMRON RELAY & DEVICES Corporation Issued by Checked by Authorized by March 17, 2011 M.Miura March 17, 2011 T.FUKUDA March,17,2011 K.Kawahara PRODUCT SPECIFICATION NAME: MODEL: ITEM: TERMINAL RELAY G6C-4B(N)(D) ALL RATINGS After the confirmation for all description on the specification sheet, your kindly cooperation with sending back the original copy with your acknowledgement to us is required until --- --, ----. Receipt Stamp (For receipt purpose only) Submitted Stamp Stamp of sales office Stamp of an agency Please accept handling of this specification sheet as for reference use if no reply received. Distribution Revision history Copies See Item -- Customer 1 Sales office: ( ) --- For return ---

No. (2/8) 1. Classification Terminal Relay 2. Construction 2.1 Outline dimensions See item 14. 2.2 Connection diagram ----- 2.3 Contact configuration SPST-NO+SPST-NC X 2 3. Standards 3.1 Approved standards UL: UL508(E87929), CSA: C22.2 No.14(LR35535), 3.2 Conformed standards ------- 4. Ratings (per G6C relay 1pc.) 4.1 Coil ratings See table 1 (1) Rated voltage and Frequency --- VDC --- Hz (2) Rated current Set --- ma± --- Hz(at V, on Hz) Reset --- ma± --- Hz(at V, on Hz) (3) Coil resistance Set --- ma± --- Hz(at V, on Hz) Reset --- ma± --- Hz(at V, on Hz) (4) Operate voltage --- to --- % of the rated voltage (5) Rated power consumption Approx. --- W MAX. 4.2 Contact ratings (1) Rated load Resistive load 250 VAC 8 A 30 VDC 8 A Inductive load 250 VAC 3.5 A (p.f. = 0.4) 30 VDC 3.5 A (L/R = 7 ms) (2) Rated carry current 8 A (3) Max. switching voltage 380 VAC 125 VDC (4) Max. switching current Resistive load AC 8 A DC 8 A Inductive load AC 8 A (p.f. = 0.4) DC 8 A (L/R = 7 ms) (5) Max. switching capacity Resistive load AC 2000 VA DC 240 W Inductive load AC 875 VA (P.f. = 0.4) DC 170 W (L/R = 7 ms) 5. Characteristics (Initial value) 5.1 Contact resistance 100 mω Max. (Initial value) Measured by the voltage drop method with DC5 V 1 A applied

No. (3/8) 5.2 Must operate voltage(or current) --- ( V ma) Max. Must set voltage(or current) See table 1 5.3 Must release voltage(or current) --- ( V ma) Max. Must reset voltage(or current) See table 1 5.4 Operate time Set time 10 ms Max. (at rated voltage) 5.5 Release time Reset time 10 (G6B-4B/-4BN) ms Max. (at rated voltage) 15 (G6B--4BND) ms Max. (at rated voltage) 5.6 Insulation resistance 1000 MΩ Min. (at 500VDC) 5.7 Dielectric strength (at 50/60Hz for 1 minute) (1) Between coil contacts of the different polarity 250 VAC (2) Between contact terminals of the different polarity 2000 VAC (3) Between contact terminals of the same polarity 1000 VAC (4) Between coil and contacts 2000 VAC 5.8 Temperature rise (1)Coil 50 C Max. (by the coil resistance method) Ambient temperature 55 C Applied voltage of coil: 100 % of rated voltage Carry current of contact: 8 A (2)Contact 65 C Max. (by the coil thermometer method) Ambient temperature 55 C Applied voltage of coil: 100 % of rated voltage Carry current of contact: 8 A 5.9 Vibration resistance (1) Destruction Must be free from any abnormality in both the construction and characteristics after the relay is held at a variable vibration of 0.75 mm single amplitude ( 1.5 mm double amplitude) at a vibration frequency of 10 to 55 to 10 Hz in each direction for 2 hours. (2) Malfunction Contacts must not open for 1 ms or longer after the relay (When energized) is held at a variable vibration of 0.75 mm single amplitude ( 1.5mm double amplitude) at a vibration frequency of 10 to 55 to 10 Hz in each direction for 1 cycle. (When not energized) Contacts must not open for 1 ms or longer after the relay is held at a variable vibration of 0.75 mm single amplitude ( 1.5mm double amplitude) at a vibration frequency of 10 to 55 to 10 Hz in each direction for 1 cycle.

No. (4/8) 5.10 Shock resistance (1) Destruction Must be free from any abnormality in both the construction and characteristics after the relay is subjected to a shock of 1000 m/s 2 in each direction 5 times. (2) Malfunction Must be free from a contact opening of 1 ms or longer (When energized) after the relay is subjected to a shock of 100 m/s 2 in each direction 5 times. (When not energized) Must be free from a contact opening of 1 ms or longer after the relay is subjected to a shock of 100 m/s 2 in each direction 5 times. 5.11 Temperature resistance (1) Heat resistance Must be free from any abnormality in both the construction and characteristics after the relay is left in a temperature of 85±2 C for 16 hours and then in room temperature and humidity for 2 hours. (2) Cold resistance Must be free form any abnormality in both the construction and characteristics after the relay is left in a temperature of -55±3 C for 72 hours and then in room temperature and humidity for 2 hours. 5.12 Moisture resistance Must be free from any abnormality in both the construction and characteristics after the relay is left in a humidity of 90 to 95 %RH for 48 hours at a temperature of 40±2 C, and then in room temperature and humidity for 2 hours. Insulation resistance, however, must be 5 MΩ MIN. 5.13 Terminal strength Must be free from any abnormality after a tensile stress of 49N is applied to the terminal in the vertical direction for 1 seconds. Any deformation of the terminal by the load shall not be regarded as a mechanical damage. * Appropriate clamp torque: 0.78 to 1.18 N m 5.14 Insert stress ----- N 5.15 Tensile stress ----- N 5.16 Mounting strength Must be no damaging nor shaky mounting part after a tensile stress of 49N is applied to the horizontal direction and for 1 second. (For a rail direction, 9.8 N Min.)

No. (5/8) 5.17 Endurance (1) Mechanical endurance 50,000,000 operations Min. (under no load at operating frequency of 18,000 operations/h) (2) Electrical endurance 100,000 operations Min. (under rated load at operating frequency of 1,800 operations/h) (3) Endurance of insert and remove --- times Min. 5.18 Failure rate P Level λ 60 = 0.1 10-6 (Reference value) Condition: Resistive load 5 VDC 10 ma Switching ----- operations/h 6. Standard test conditions Unless otherwise specified, the values described in this specification obtained under the following conditions as standard. 6.1 Temperature 23 C 6.2 Humidity 65% RH 7. Storage conditions 7.1 Environments (1) Must be in a location where the product or container is not exposed to corrosive gas such as hydrogen sulfide gas or salty air. (2) Must be in a location where no visible dust exists. (3) Must be in a location without direct sunlight. Any stress to the product which may result in the deformation or change in quality of the product is not allowed. 8. Operating conditions Use the product under the following conditions 8.1 Temperature -25 to +55 C (Without icing nor condensation) 8.2 Humidity 45 to 85 % RH 8.3 Mounting direction --- 8.4 Environments (1) Must be in a location where the product or container is not exposed to corrosive gas such as hydrogen sulfide gas or salty air. (2) Must be in a location where no visible dust exists. (3) Must be in a location without direct sunlight. Any stress to the product which may result in the deformation or change in quality of the product is not allowed.

No. (6/8) 9. Changing the contents of this document OMRON reserves the right to change the specifications except for the ratings, performance, structure, outer dimensions, and mounting dimensions. 10. Valid term of this specification This specification becomes invalid if you do not contact us after a lapse of 1 year from the issue date of this specification. 11.Handling precautions Do not drop or give a shock to the product to maintain the initial performance when handling it. 12. Other Information To Customers Purchasing OMRON Products Agreement when Placing Orders Thank you for using OMRON products. Unless otherwise specified in a written estimate, contract, or specifications, the following conditions and warranty information apply when an OMRON control device (hereafter called OMRON Product ) is ordered from catalogs. Ordering an OMRON Product implies consent to these terms and conditions. 1. Warranty (1) Warranty Period The warranty period for an OMRON Product is one year from either the date of purchase or the date on which the OMRON Product is delivered to the specified location. (2) Extent of Warranty If an OMRON Product is subject to a failure for which OMRON is responsible during the warranty period, either a replacement product will be provided or the defective product will be repaired free of charge at the place of purchase. This warranty, however, will not cover problems that occur as a result of any of the following. a) Using the OMRON Product under conditions or in an environment not described in catalogs or in the specifications, or not operating the OMRON Product according to the instructions contained in catalogs or in the specifications. b) Problem caused by something other than the OMRON Product. c) Modifications or repairs performed by a party other than OMRON. d) Using the OMRON Product for other than its designed purpose. e) Problems that could not have been foreseen with the level of science and technology that existed at the time the OMRON Product was shipped. f) Problems caused by an Act of God or other circumstances for which OMRON is not responsible. This warranty covers only the OMRON Product itself. It does not cover any other damages that may occur directly or indirectly as a result of a problem with the OMRON Product.

No. (7/8) 2. Limitations of Liability (1) OMRON shall not be responsible for special, indirect, or consequential damages originating in an OMRON Product. (2) For programmable OMRON Products, OMRON does not accept responsibility for any programming that is performed by a party other than OMRON, or for any results arising from that programming. 3. Applicable Conditions (1) When using OMRON Products in combination with other products, it is the user s responsibility to confirm compliance with all applicable standards and regulations. It is also the user s responsibility to confirm the suitability of the OMRON Products for the system, devices, and equipment that are being used. OMRON accepts no responsibility for the suitability of OMRON Products used in combination with other products. (2) When using OMRON Products in any of the following applications, consult an OMRON representative and check specifications to allow sufficient leeway in ratings and performance, and to implement suitable safety measures, such as safety circuits, to minimize danger in the event of an accident. a) Outdoor applications, applications with potential for chemical contamination or electrical interference, or application under conditions or environments not described in catalogs. b) Nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, or equipment regulated by government or industrial standards. c) Other systems, machines, and equipment that may have a serious influence on human life and property. d) Equipment requiring a high level of reliability, such as gas, water, or electrical supply systems, and systems that operate 24 hours a day. e) Other applications requiring a high level of safety, corresponding to points I) to iv), above. (3) When OMRON Products are used in an application that could pose significant risk to human life or property, the overall system must be designed so that the required safety can be ensured by providing notice of the danger and incorporating redundancy into the design. Make sure that OMRON Products are appropriately wired and mounted to serve their intended purpose in the overall system. (4) Application examples provided in catalogs are for reference only. Confirm functionality and safety before actually using the devices and equipment. (5) To prevent unexpected problems from arising due to the OMRON Product being used incorrectly by the customer or any other party, make sure that you understand and carefully observe all of the relevant prohibitions and precautions. 4. Changes to Specifications Specifications and accessories to the products in catalogs may be changed as needed to improve the products or for any other reason. Check with your OMRON representative for the actual specifications for OMRON Products at the time of purchase. 5. Extent of Service The price of an OMRON Product does not include service costs, such as dispatching technical staff. If you wish for service, please consult with your OMRON representative.

No. (8/8) 6. Prices The standard prices listed in the catalog are for reference only, and do not indicate fixed purchase prices. The prices also do not include tax. 7. Applicability The above information assumes that business and product application will be conducted in Japan. For business and application outside of Japan, consult with your OMRON representative. 13. Others 13.1 Coil ratings (table 1) Rated voltage (V) Rated current (ma) Coil resistance (Ω) DC5 40 (42) <36> 125 DC12 16.7 (18.6) <17.7> 720 DC24 8.3 (10.5) <10.2> 2,880 Operate voltage 70%MAX. (80%MAX.) Release voltage % of rated voltage MAX. voltage 10%MIN. 130% Power consumption (mw) Approx. 200 Note: 1. Rated current and coil resistance were measured at a coil temperature 23 C with a tolerance ±10%. 2. The value in ( ) of Rated current is included LED current of 4BN type. The value in < > of Rated current is included LED current of 4BND type. 3. The value in ( ) of Operate voltage is for 4BN/-4BND type (with operating indicator type). 4. Operating characteristics were measured at a coil temperature of 23 C. 5. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is no continuous allowance. 13.2 G6C models are connected directly to boards to increase reliability and the relays are thus not replaceable. 14. Dimensions Note: All units are millimeters unless otherwise indicated.