Mach LED 2. Mach LED 2. Mach LED 2 Drawings. Small OT-light with LED technology. Dr. Mach GmbH & Co. KG

Similar documents
The LED revolution. Mach LED 5MC Mach LED 3MC Mach video transmission system. LED OT-light systems for surgery L E D O T - L I G H T S

Mach LED 300. OT-light with LED technology. Mach LED 300 Mach LED 300 with video system

The LED revolution. Mach M5 LED Mach M3 LED Mach video transmission system. LED OT-light systems for surgery L E D O T - L I G H T S

Dr. Mach Light System M3

Pearl Series. LED Surgical Lights. Pearl 160 & Pearl 130 LED Lights

LED 700 / 500 / 200 Series Surgical Operating Lamps

Brilliant Light YLED-1F. For Diagnosis and Surgery

Hy LED 9 Series LED Surgical Lights

light iled: Milestones The world s leading LED surgical lights delivering unrivalled performance.

Operating Light marled V10 LC / V10 LC D

Operating Light marled V16 / V10 D

Operating Light marled V10 / V10 Ceiling

Operating Lights. marlux with centrixbeam LIGHT OF THE NEXT GENERATION

VOLISTA. Setting the standard for operating rooms. This document is intended to provide information to an international audience outside of the US

Operating Light marled V16 / V16 D

WHAT IS A SURGICAL LIGHT? BASIC_ELEARN_ORLIGHTS_ORLIGHTSWhat_is_a_surgical_light_EN_REV01_ ***NOT FOR USE IN THE US***

Astramax HD-LED Surgical Light

Perfect Shadow Management. A True Color Rending. Deep Cavity Penetration. Experience, Technology and Design

SURGICAL LIGHT TECHNOLOGY BEHIND THE LIGHT

MEDICARE GB LTD LIGHTING CATALOGUE. Approved Luxo Dealer

D med saturn LED LED TREATMENT LIGHTS

The perfect image for every mood. With the KREIOS G1 LED image projector.

CHROMOPHARE LED. E-series surgical lights with LED technology. E-Serie OP-Leuchten mit LED-Technologie

PENTALED. The first one, the original one!

Quasar elite High Performance Surgical Lighting

Datasheet iled 7 Surgical Light The World in a New Light

Examination light with LED technology CHROMOPHARE F 300

Brighten your Expertise

Surgical Solutions. Brightness. Clarity. Efficiency. G-Series Surgical Lighting System. One Integrated Approach to Healthcare

Surgical Lights. G-Series Surgical Lighting System

MI Series The guiding lights for all patient care

Operating Lights. marlux with centrixbeam LIGHT OF THE NEXT GENERATION

Professional LED Light System. Luvis-C100 Luvis-C200 Luvis-S100 Luvis-S200

Highest Level of Passenger Comfort

Vu LED Surgical Light at a Glance

BASICS OF GALLERY LIGHTING

Polaris 50 Medical Lights and Video

Our history. A tradition for innovation. 1 st Catalogue A500 Stellare. 35 th anniversary Technological innovation award. premises

Indoor/ outdoor projector MINI-PROJECTOR-02 3LED RECESSED Ufo-02

Manual for BMS E1 eplan series, compound microscope

Our focus is surgical headlights Endovision.com.au

ARTIFICIALIRIS PHOTO DIRECTIVES

4-dimensional surgical lighting. Surgical lighting

QT LUMINAIRE. Pendiro.

LED illumination for image processing and microscopy

OMM300. Inverted Metallurgical Microscope

From the start the main activity of our company was the development and production of infrared illuminators.

CHROMOPHARE D 650, D 530, D 500. Service Manual (E) Single Light and Combination Light

Directions for Use. Veinlite A. TransLite, LLC.

Adding features such as color adjustability poses challenges but can improve the safety of surgeries. Corey Bergad, Luminus Devices.

Complementary colours (Item No.: P )

DENTAL LIGHT POLARIS SWITCH DENTAL LIGHT POLARIS SENSOMATIC DENTAL LIGHT POLARIS SWITCH, 3 rd AXIS Mov.

LED LIGHTING GUIDE. We will help you find the right light bulb!

SCHOTT Lighting and Imaging. Contents. overview general lighting situations. illumination with fiber optics. direct LED illumination

DEUTROFLUX. Accessories for Magnetic Particle Inspection. Field Strength Gauge DEUTROMETER II. In Actual Size

FL3 Series Tri-lenses for LUXEON TM K2 LEDs

User instructions Metallurgical inverted microscope

Full Line Lighting Guide

LED Technology: the perfect lighting solution

Operating Lights. marled with VariLUX. Outstanding LED light of the 2 nd generation

Standard Halogen Light

TABLETOP WORKSHOP. Janet Steyer

Basic Lighting Design Seminar

User Manual. Trinocular Metallurgical Microscope. MicroscopeNet.com

15-06 Morlot Avenue, Fair Lawn, NJ USA Tel: (201) Fax: (201)

LPX SERIES Constant Potential Portable X-Ray

How-to guide. Working with a pre-assembled THz system

Lumen, Lux & Candela

DETAILING AND COLOUR MATCH

YOUNGS MODULUS BY UNIFORM & NON UNIFORM BENDING OF A BEAM

KODAK EKTACHROME RADIANCE III Paper

DETAILING AND COLOUR MATCH

FLP4 Series Quad-Lens for LG Innotek 3535 Ceramic 1 LEDs

Light Sources. Hard VS Soft

Industrial image processing in the quality management of the plastics processing industry

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

Light and Optical Systems

TECHNOLOGY INFORMATION SHEET

PLANONLIGHT LED Ready for duty in the toughest industrial and system environments.

System Two Making your sugical outcomes brighter

LED light bulbs A lighting revolution

Radium presents: The Radium LED programme. Radium. including LEDOTRON-Products

KTP LASER. Photocoagulation System

stube LED lamp with natural light, energy efficient Product awarded by the International Fair Examples of savings ver. 16.

5.7 Super/hypermarket

VistOR PRO, PR, EX Surgical Lights

APPLICATIONS FOR TELECENTRIC LIGHTING

lightstudio light box to illuminate a scene with different standardized light types

Electrical Illumination and Design

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

-dec Lights. LED Halogen

Bulletin Post. Metamerism and Illuminants C O A T S S E W I N G S O L U T I O N S. Contents. Introduction. What is Metamerism? Kinds of Metamerism

EnFocus Your Upgrade Path to High Performance Intrasurgical OCT

ETC GENERAL INFORMATION ORDERING INFORMATION. Selador Lustr CE. Accessories

White Light Emitting Diodes. Erick J. Michel Energy Law Spring 2009 Professor Bosselman

nexormedical.com NOVA.light NOVA.light

Compact High Intensity Light Source

Radium presents: The Radium LED programme

LUNA OUTSTANDING HIGH MODULARITY

Tradition Redefined. LED Theatre spots by. Tradition Redefined. Infinity Signature series

Transcription:

PA_01 Drawings 2700 Ceiling fixation for standard room heights 3000 480 230 2260 2320 min 950 max 2130 Ceiling fixation for low room heights min 1260 max 2380 850 300 Wall fixation 90 2300 1 2280 min 900 max 2080 with four castors 1430 1660 (for room height 3,00m) 1830 Dimensions in milimeter Dr. Mach GmbH & Co. KG Flossmannstraße 28 D-85560 Ebersberg Phone: +49 (0) 8092 / 20 93-0 Fax: +49 (0) 8092 / 20 93-50 www.dr-mach.com e-mail: info@dr-mach.de Subject to change without notice due to technical modification 59000300 A02 Version: 04/2014 Small OT-light with LED technology 810 L E D O T - L I G H T S

Dr. Mach LED technology Dr. Mach provides two different LED technologies for its OT-lights: Common characteristics of the MC models and SC models 1. MC models are equipped with Multi-Colour-chips. The use of different-coloured LED-chips allows the surgeon to change the colour temperature of the OT-light depending on the preference for a more cold-white light (colour temperatures 4500 K) or for a warm-white OT-light (colour temperatures 4250 K). The surgeon can set the colour temperature according to the tissue structure, the surgical application and individual colour sensitivity. This way we avoid tiredness during work: for instance, dazzling effects can be avoided after longer interventions by using a warmer light. On the other hand it is possible to increase the contrast by using higher colour temperatures, which supports the surgeon s power of concentration. 2. SC models are equipped with Single-Colour-chips. Changing the colour temperature is not possible in this case. Of course all the other advantages of the LED technology are also implemented here, or they can be ordered for surcharge (integrated laser pointer). Facetted multi-lens system A multitude of computer-calculated facetted lenses guarantees homogeneity and lowest shadiness in the light field. Separately arranged optical systems, each with four LED modules (Multi- Colour models) or each with one LED module (Single-Colour models), generate their own light field, which increases the contrast effect of the OR light. Light intensities of 100.000 Lux can be attained without difficulty. Lighting technology - special features of the MC models Superiour colour rendition Colour composition inside the light head Dr. Mach already merges the different coloured LED s by a computercalculated optical system with light guide and facetted lenses. This means: The composed light leaves the optical system as white light and is dispersed over the wound field homogeneously. Colour shadows in the light beam of the OR light caused by the surgeon s head, shoulder or hands are avoided by the colour composition in the optical system. light guide Conventional lighting systems R 9 -values between 20 und 70 R a -values between 50 und 95 Dr. Mach light system (MC models) R 9 90 R a 96 With colour rendering indexes R a above 96 and R 9 (red) above 90 the surgeon recognizes clearly the tiniest nuances of colour in tissue. The colour rendering index for SC models is R a = 95. For recognizing the exact colour spectrum of the wound the exact rendition of the red colour range is essential. R 9 (red) 90 means for the surgeon a visibly better recognition of details. The colour spectrum of the wound is rendered naturally with rich contrast. The OT-light clearly provides welcome relief for your eyes. Changing the light colour Illumination in depth The use of different coloured LED s makes it possible for the first time in surgery to change the light colours depending on the application. The surgeon has the possibility to choose the optimum OR light according to the tissue type and the wound field texture. Five different colour temperature values can be set: 3, 4000, 4250, 4500 and 4 Kelvin.* The setting can be done either at the key pad on the lamp housing or by a turn of the ring at the sterilisable handle. You have the possibility to increase the light intensity of the central segment of the OT-light. This enables an optimum illumination of the wound field according to its texture and the shadowing effects. A high and adequate light intensity is very important especially in cases of narrow and deep wound channels. * The LED-OT-lights can be equipped optionally with different colour temperature ranges, e.g. from 3500 K to 5000 K. 3 Kelvin 4250 Kelvin 4 Kelvin 2 3

Dr. Mach LED technology Integrated OT-laser pointer (optional) The built-in laser pointer always indicates the middle of the light field and helps the surgeon to find the optimal position of the OT-light to the wound field. Hygiene The disk sealings of the light outlets and the circumferential sealing cord avoid infiltrations of dust, dirt and liquids inside the lamp head. The laser pointer can be activated either at the key pad on the lamp housing or by a turn of the ring at the sterilisable handle. After a short time the laser pointer turns off automatically. Key pad on the lamp housing Several light functions can be adjusted electronically, such as: Switching ON and OFF Illumination in depth Electronic light intensity control Endo-Light Changing the colour temperature: 3, 4000, 4250, 4500, 4 K Wall panel The OT-light can be operated at the wall panel (optional equipment against surcharge). The light functions can be adjusted on the wall panel as well as on the key pad of the light. Several light functions can be adjusted electronically, such as: Switching ON and OFF Illumination in depth Electronic light intensity control Endo-Light Changing the colour temperature (MC models only) Flow properties During development high attention was paid to the performance of the new LED OR lights in laminar-flow ceiling systems. The flow-enhancing ring form of all light heads and the minimal surface avoid any heat increase in the surgeon s head area and create a perfect laminar flow performance, being a basic hygienic requirement in surgery. Handle Merging of light fields is done by turning the sterilisable handle. The ring at the top of the handle allows the surgeon to set the most important light functions in the sterile area. The light functions mentioned below can be set at the ring of sterilisable handle: Depth light Light intensity control Colour temperature (MC-models only) Cool light The LED technology is much more effective than conventional light sources such as halogen bulbs. The heat radiation is reduced to a minimum without using any expensive filter technique. The temperature increase in the surgeon s head area is almost nonexistent. Long life-span/low power consumption The life-span of more than 40.000 operating hours reduces the costs for exchanging and replacing the illuminants considerably, compared with the conventional halogen technology used with former OT-lights. By implementation of the LED technology the power consumption could be reduced partially with more than 50%. 4 5

PA_01 OT-light for low room height 2,80m ceiling models Skizzen Deckenbefestigung normale Raumhöhe 3000 480 Deckenbefestigung niedrige Raumhöhe 230 2320 min 950 max 2130 850 300 2700 for standard room height > 2,80m 2260 with wall fixation min 1260 max 2380 Technical data light system MC SC Wandbefestigung Light intensity Lux at 1 meter distance 100.000 100.000 90 Colour rendering index R a (1) at 4500 Kelvin 96 95 Focussable size of the light field (in cm) 17-28 17-28 Colour temperature (Kelvin) 3, 4000, 4250, 4500, 4 4500 Electronic light intensity control at the lamp head 5-100% 5-100% 2300 2280 min 900 max 2080 with integrated emergency power unit operating time 3 hours (bei Raumhoehe 3,00m) Temperature increase in head area 0,5 C 0,5 C Voltage 24V-30V DC 24V-30V DC Total power consumption 70 W 30 W Number of LEDs 84 21 with integrated power supply Vierfuß-Stativ 1430 Life-span of the LEDs 40.000 h 40.000 h Working distance (in cm) 60-150 60-150 Diameter of the lamp head (in cm) 49 49 115.000 Lux The light beams of the three outer clusters can be merged by turning the sterilisable handle. 1 1660 1830 Maßangaben in Millimeter Height adjustment (in cm) 118 118 (1) R a is an average of R 1 = burnt pink, R 2 = mustard yellow, R 3 = yellow green, R 4 = light green, R 5 = turquoise blue, R 6 = skyviolet, R 7 = violet, R 8 = lilac. Maximum value = 100. 810 6 7

OT-light for low room height 2,80m ceiling models for standard room height > 2,80m with wall fixation Technical data light system MC SC Light intensity Lux at 1 meter distance 115.000 115.000 Colour rendering index R a (1) at 4500 Kelvin 96 95 Focussable size of the light field (in cm) 17-28 17-28 Colour temperature (Kelvin) 3, 4000, 4250, 4500, 4 4500 Electronic light intensity control at the lamp head 5-100% 5-100% Temperature increase in head area 0,5 C 0,5 C with integrated emergency power unit operating time 3 hours Voltage 24V-30V DC 24V-30V DC Total power consumption 70 W 30 W Number of LEDs 84 21 Life-span of the LEDs 40.000 h 40.000 h with integrated power supply Working distance (in cm) 60-150 60-150 Diameter of the lamp head (in cm) 49 49 Height adjustment (in cm) 118 118 115.000 Lux The light beams of the three outer clusters can be merged by turning the sterilisable handle. (1) R a is an average of R 1 = burnt pink, R 2 = mustard yellow, R 3 = yellow green, R 4 = light green, R 5 = turquoise blue, R 6 = skyviolet, R 7 = violet, R 8 = lilac. Maximum value = 100. 6 7