Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Similar documents
DYNAMIC VOLTAGE RESTORER USING THREE PHASE AC-AC CONVERTER

ISSN Vol.03,Issue.11, December-2015, Pages:

This paper deals with a new family of high boostvoltage inverters, called switched-inductor quasi-z-source inverters.

A DYNAMIC VOLTAGE RESTORER (DVR) BASED MITIGATION SCHEME FOR VOLTAGE SAG AND SWELL

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Mitigation of Power Quality Problems Using DVR in Distribution Network for Welding Load

International Journal of Advance Engineering and Research Development

Compensation of Unbalanced Sags/Swells by Single Phase Dynamic Voltage Restorer

Protection from Voltage Sags and Swells by Using FACTS Controller

Design of Chopper Fed Z Source PWM Inverter

I. INTRODUCTION A. GENERAL INTRODUCTION

Z-SOURCE INVERTER WITH A NEW SPACE VECTOR PWM ALGORITHM FOR HIGH VOLTAGE GAIN

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

Simulation of a Dynamic Voltage Restorer to Compensate Voltage Sag for Improving Power Quality

COMPENSATION OF VOLTAGE SAG USING LEVEL SHIFTED CARRIER PULSE WIDTH MODULATED ASYMMETRIC CASCADED MLI BASED DVR SYSTEM G.Boobalan 1 and N.

Harmonic Reduction in Five Level Inverter Based Dynamic Voltage Restorer

Voltage Quality Enhancement in an Isolated Power System through Series Compensator

Performance Enhancement of Sensorless Control of Z-Source Inverter Fed BLDC Motor

MODELING AND SIMULATION OF Z- SOURCE INVERTER

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

CHAPTER 5 CONTROL SYSTEM DESIGN FOR UPFC

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Reduce the Harmonics Distortion of Sensitive Load against the Induction Motor Drive Non-Linear Load

II. L-Z SOURCE INVERTER

Control Of Shunt Active Filter Based On Instantaneous Power Theory

ISSN Vol.07,Issue.21, December-2015, Pages:

ANALYSIS OF PWM STRATEGIES FOR Z-SOURCE CASCADED MULTILEVEL INVERTER FOR PHOTOVOLTAIC APPLICATIONS

Design and Implementation of Quasi-Z-Source Inverter for Off-grid Photovoltaic Systems

Design of Interline Dynamic Voltage Restorer for Voltage Sag Compensation

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

A Review on Improvement of Power Quality using D-STATCOM

DESIGN AND DEVELOPMENT OF SMES BASED DVR MODEL IN SIMULINK

Mitigation of Voltage Sag and Swell Using Dynamic Voltage Restorer

Hybrid Full-Bridge Half-Bridge Converter with Stability Network and Dual Outputs in Series

A Three-Phase AC-AC Buck-Boost Converter using Impedance Network

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

Development and Simulation of Dynamic Voltage Restorer for Voltage SAG Mitigation using Matrix Converter

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Design and Simulation of Dynamic Voltage Restorer (DVR) Using Sinusoidal Pulse Width Modulation (SPWM)

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

Mitigation of Voltage Sag/Swell Using UPQC

SIMULATION AND FABRICATION OF SINGLE PHASE Z-SOURCE INVERTER FOR RESISTIVE LOAD

SIMULATION VERIFICATION OF DYNAMIC VOLTAGE RESTORER USING HYSTERESIS BAND VOLTAGE CONTROL

Impedance Source Inverter for Wind Energy Conversion System

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Power Quality and the Need for Compensation

Modified three phase Unified Power Quality Conditioner with capacitor midpoint topology

CHAPTER 6 BRIDGELESS PFC CUK CONVERTER FED PMBLDC MOTOR

Simulation and Implementation of DVR for Voltage Sag Compensation

Self-Tuning PI Control of Dynamic Voltage Restorer Using Fuzzy Logic

THREE PHASE UNINTERRUPTIBLE POWER SUPPLY BASED ON TRANS Z SOURCE INVERTER

Synchronous Reference Frame Theory (SRF) along with PI Controller Based Dynamic Voltage Restorer

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

Comparison of the Traditional VSI & CSI with Novel ZSI for Study the Pre-Dominate Harmonics Effect

Power Quality Improvement using Hysteresis Voltage Control of DVR

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

OVERVIEW OF DVR FOR POWER QUALITY IMPROVEMENT

Multi Level Inverter Based Active Power Filter for Harmonic Reduction

DYNAMIC VOLTAGE RESTORER (DVR) FOR VOLTAGE SAG COMPENSATION WITH FUZZY LOGIC CONTROLLER. Chennai, Tamilnadu, India. Chennai, Tamilnadu, India.

Implementation of UPQC for Voltage Sag Mitigation

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

Voltage Sag Mitigation Using Dynamic Voltage Restorer System

Shobhana D. Langde 1, Dr. D.P. Kothari 2 1,2 Electrical Engineering Department, R.T.M. Nagpur University.

Current Control Technique for Three Phase Shunt Active Power Filter by Using Adaptive Hysteresis Current Controller

Unit.2-Voltage Sag. D.Maharajan Ph.D Assistant Professor Department of Electrical and Electronics Engg., SRM University, Chennai-203

ISSN: [Singh* et al., 6(6): June, 2017] Impact Factor: 4.116

Mitigation of Fault in the Distribution System by using Flexible Distributed Static Compensator (FD-STATCOM)

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

SHUNT ACTIVE POWER FILTER

Review on Shunt Active Power Filter for Three Phase Four Wire System

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Study & Comparison of Various Topologies of Dynamic Voltage Restorer & Its type: a Review

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

II. RESEARCH METHODOLOGY

Simulation of Z-Source Inverter Fed Induction Motor

A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS

Bridgeless Cuk Power Factor Corrector with Regulated Output Voltage

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM

Comparative Study of Sag & Swell Mitigation by a Novel Multi Level DVR with Wavelets

A Switched Boost Inverter Fed Three Phase Induction Motor Drive

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

Literature Review for Shunt Active Power Filters

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR)

An Effective Method over Z-Source Inverter to Reduce Voltage Stress through T-Source Inverter

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

Mitigation of Voltage Sag/Swell by Using Battery Energy Storage DVR for Induction Motor Drive Applications

Phase Lock Loop Control of Matrix Converter based Dynamic Voltage Restorer for Sag Reduction

Design of Z-Source Inverter for Voltage Boost Application

DOWNLOAD PDF POWER ELECTRONICS DEVICES DRIVERS AND APPLICATIONS

Performance Analysis of Three Phase Cascaded H-Bridge Multi Level Inverter for Voltage Sag and Voltage Swell Conditions

SRF CONTROLLED DVR FOR COMPENSATION OF BALANCED AND UNBALANCED VOLTAGE DISTURBANCES

Performance comparison of Quasi-Z-Source inverter with conventional Z-source inverter

Multifunctional Dynamic Voltage Restorer Using Matrix Converter Resmi. S, Reshmi. V, Joffie Jacob Amal Jyothi College of Engineering, Kanjirappally

DYNAMIC VOLTAGE RESTORER FOR VOLTAGE SAG MITIGATION IN OIL & GAS INDUSTRY

Transcription:

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION 1 Arsha.S.Chandran, 2 Priya Lenin 1 PG Scholar, 2 Assistant Professor 1 Electrical & Electronics Engineering 1 Mohandas College of Engineering & Technology, Trivandrum, India Abstract Power quality is one of the major concerns in the era of power system. Failures due to disturbances like voltage sag, swell and interruption create high impact on production cost. Inorder to overcome this problem Dynamic Voltage Restorer is used, which eliminates voltage sag and swell in the distribution line. The DVR is a dynamic solution for protection of critical loads from voltage sags/swells. The DVR helps to restore constant load voltage and voltage wave form by injecting an appropriate voltage. A new topology based on Z-source inverter is presented in order to enhance the voltage restoration property of dynamic voltage restorer. Z-source inverter ensures a constant DC voltage across the DC-link during the process of voltage compensation. The modeling of Z-source based dynamic voltage restorer is carried out component wise and their performances are analyzed using MATLAB software. Index Terms Z-Source Inverter, Dynamic Voltage Restorer, Pulse Width Modulation, Total Harmonic Distortion I. INTRODUCTION Modern power system has complex networks comprising of several generating stations and load centers which are interconnected through transmission lines. Power systems have numerous non linear loads that significantly affect the quality of the power supply. Deviation of voltage, current or frequency can be described as a power quality problem which may further result in incorrect operation or even collapse of equipments. Voltage sag, flicker, harmonic distortion, impulse transients and interruptions are various power quality problems we interface. Among those the most prominent ones are voltage sag and swell as it possesses a serious threat to industries since it can occur more frequently. Reactive power can be utilized to help voltage restoration by injecting voltage with a phase advance with respect to the sustained source-side voltage. As there was growing interest in mitigating power quality disturbance, the idea of custom power devices was introduced. Voltage sag/sell which is a challenging problem to the utility industry can be compensated by injecting power into the distribution system. Dynamic Voltage Restorer (DVR) is one among the most significant custom power devices which is connected in series to the distribution system. It is usually installed in the distribution system between the supply and the critical load feeder at the point of common coupling (PCC). Other than voltage sag and swell compensation, DVR can also add other features like: line voltage harmonics compensation, reduction of transients in voltage and fault current limitations. Dynamic Voltage Restorer comprises of a set of series and shunt converters connected back-to-back, three series transformers, and a dc capacitor and is normally installed on common dc link. The Pulse-width modulation of Z-source inverter has recently been proposed as an alternative power conversion concept as they have both voltage buck and boost property. Generally, the DVRs consists of voltage source inverter based DVR (VSI-DVR), current source inverter based DVR (CSI-DVR) and impedance source inverter based DVR (ZSI-DVR). The main disadvantage of VSI-DVR is their buck (step-down) type output voltage characteristics thereby the maximum output voltage is limited by DC link voltage. The upper and lower devices of each leg cannot be gated on simultaneously, so a shoot-through would occur and destroy the devices. The shoot-through is a forbidden switching state for the VSI. The CSI-DVR is a boost type so its output voltage has to be greater than the DC voltage. For the application where a wide voltage range is desirable an additional DC-AC boost converter is needed. The additional power conversion stages increase system cost and lowers efficiency. At least one of the upper devices and one of the lower devices have to be gated on and maintain on at any time. Otherwise, an open circuit of the DC inductor would occur and destroys the devices. ZSI is a new type of converter in power conversion which has unique features that can overcome the limitations of VSI and CSI. The unique feature of the ZSI is that the output AC voltage can be any value between zero and infinity regardless of the DC voltage. That is, the ZSI is a buck-boost inverter that has a wide range of obtainable voltage. Unlike a VSI and CSI, the shoot-through state is not harmful and actually has been utilized in ZSI. The Z-source converter employs a unique X-shaped impedance network on its dc side for achieving both voltage buck and boost capabilities this unique features that cannot be obtained in the traditional voltage-source and current source converters. The proposed system enables the compensation of long and significantly large voltage sags. Passivity-based dynamical feedback controllers can be derived for the indirect stabilization of average output voltage. The derived controllers are based on a suitable stabilizing damping injection scheme. Installation of the world's first Dynamic Voltage Restorer (DVR) was on major US utility system to protect a critical customer plant load from power system voltage disturbances. The proposed model of Z-Source inverter based dynamic voltage restorer for voltage sag/swell compensation is simulated using MATLAB software in this paper. II. DYNAMIC VOLTAGE RESTORER Dynamic voltage restorer was originally proposed to compensate for voltage disturbances on distribution systems. A typical DVR scheme is shown in Fig. 1. The restoration is based on injecting AC voltages in series with the incoming three-phase network, the purpose of which is to improve voltage quality by adjustment in voltage magnitude, waveshape and phase shift. These are significant voltage attributes as they can affect the performance of the load equipment. Voltage restoration involves energy injection into the distribution systems and this determines the capacity of the energy storage device required in the restoration scheme. JETIR1711054 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 290

Fig.1. Block Diagram of DVR Circuit The basic functions of the DVR are the detection of voltage sag/swell occurred in the power line and injection of balance voltage through injection transformer so as to maintain the desired load voltage. This can be achieved either by receiving or rejecting the active and reactive power. It basically consists of, Battery energy storage, Voltage Source Inverter, Passive Filter and Injection/ Booster Transformer. A. Injection /Booster Transformer The primary of the injection transformer is connected in series with the distribution line whereas the secondary of the injection transformer is connected to the DVR power circuit. The main functions of Injection /Booster Transformer are the increasing the voltage supplied by the filtered Voltage Source Inverter (VSI) to a desired level and isolation of the DVR circuit from distribution network. B. Passive filter It consists of an inductor and a capacitor. It can be placed on either high voltage side or low voltage side of the injection transformer. By placing it on inverter side higher order harmonic current do penetrate to the secondary side of the transformer. The main objective of the filter is to keep the harmonic voltage content generated by the inverter within the permissible level. C. Power Converter Its basic function is to convert the DC Voltage supplied by the energy storage device to a sinusoidal voltage at any required frequency, magnitude and phase angle. There are four types of switching devices: Metal Oxide Semiconductor Field Effect Transistor (MOSFET), Gate Turn off thyristor (GTO), Insulated Gate Bipolar Transistor (IGBT) and Integrated Gate Commutated Thyristor (IGCT). Each type has its own benefits and drawbacks. D. DC energy Storage device It is used to supply the real power requirement for the compensation during the period of voltage sag. Lead-acid batteries, Super Conducting Magnetic Energy Storage (SMES), Flywheels and Super capacitors can be used as the storage devices. For DC drives such as capacitors, batteries and SMES, DC to AC conversion (inverters) is needed to deliver power, whereas for flywheel, AC to AC conversion is required. Today in phase voltage injection technique is widely used in DVR control where the load voltage V2 is assumed to be in-phase with the pre-sag voltage. As the DVR is required to inject active power into the distribution line during the period of compensation, the capacity of the energy storage unit can become a limiting factor in the disturbance compensation process. If capacitors are used as energy storage, the DC-link voltage will decrease with the dwindling storage energy during compensation. The corresponding phasor diagram describing the electrical conditions during voltage sag is depicted in Fig. 2, where only the affected phase is shown for clarity. Let the parameters I1, φ, δ and α represent the load current, load power factor angle, supply voltage phase angle and load voltage advance angle respectively. Although there is a phase advancement of α in the load voltage with respect to the pre-sag voltage in Fig. 2, only in-phase compensation is considered. Here the injected voltage is in phase with the supply voltage (α = δ). Fig.2. Vector Diagram of Voltage Injection Method III. Z-SOURCE INVERTER Z-source Inverter has X-shaped impedance network on its DC side, which interfaces the source and inverter H-bridge. It facilitates both voltage- buck and voltage - boost capabilities. It also has an impedance network composed of split inductors and two capacitors. The supply can be either DC voltage source or DC current source. Z-Source inverter can be of current source type or voltage source type. Fig. 3 depicts JETIR1711054 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 291

the general block diagram of Z-Source inverter. The impedance network consists of two inductors and capacitors. This combination network circuit provides the energy storage and filtering element for impedance source inverter. The second order filter property is provided by impedance source inverter. This is more efficient to suppress voltage and current ripples. Another peculiarity is that inductor and capacitor requirement should be smaller as compared to the traditional inverter. Fig.3. General Block Diagram of Z-Source Inverter The Z-Source Inverter has been an alternative to the existing inverter topologies with many inherent advantages. The Z-Source Inverter has an additional zero vector called as shoot-through switching state, which is forbidden in the traditional voltage and current source inverter. Compared to VSI and CSI, Z-Source Inverter is less affected by the EMI noise. In Table I it is shown that the single-phase Z -Source Inverter has five switching modes of which two active modes in which the dc source voltage is applied to load, two zero modes in which the inverter s output terminals are short circuited by S1 and S3 or S2 and S4 switches and a shoot-through mode which occurs as two switches on a single leg are turned on are present. Table 1. Switching Modes The shoot through period which is the time period when two switches of the same leg are gated allows the voltage to be boosted to the required value when the input dc voltage is not upto the required level. Otherwise the shoot through state is not used thus enabling the ZSI to operate as both a buck-boost inverter unlike the traditional voltage source and current source inverters. The merits of the new topology are: Same voltage boost capability is retained by providing same polarity of capacitors but with a reduced value of voltage stress across them. The inrush current at startup is effectively reduced since there is no path for current at start-up. The current and the voltage ripples in both the topologies are same, but the current across the inductor in the existing topology decreases in the non shoot through state. In the existing topology, the voltage across the capacitors is given by And in the new topology it is given as, Vc = (1- D)Vs/(1-2D) (1) Vc = [D/(1-2D)] /Vs (2) Where Vc = capacitor voltage, D = duty ratio of the shoot through state and Vs = supply voltage. The Z-Source Inverter can be operated in both boost and buck operations depending on values of modulation index (M) of Pulse Width Modulation. If M is greater than 0.5 it acts as boost inverter, if M is less than 0.5 then it acts as buck inverter. Fig.4. Proposed Z-Source Inverter topology JETIR1711054 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 292

IV. SYSTEM CONTROL SCHEME ZSI integrated DVR is having a closed loop control technique in which a PI controller is used to regulate the error signal and the output of which is obtained as the control signal. The output voltage from the load side after the occurrence of fault is sent to a summer block where it is compared along with a reference voltage signal. The error signal generated is then sent to a PI controller.through the controller, the incoming error signal is tuned and thus the control signal is obtained. This control signal is utilized for the generation of firing signals of the switching devices in the voltage source inverter section of a Z- source inverter. Pulse Width Modulation technique is used for controlling the output pulses. Simple boost control technique is used for the purpose of pulse width modulation. The modulation index also called as amplitude modulation ratio (M) which is the main control factor is defined as the ratio of amplitude of reference wave to the amplitude of carrier wave. The linearity between the modulation index and the output voltage is achieved by under modulation index (M < 1). Actually, this control strategy inserts shoot through in all the PWM traditional zero states during one switching period. This maintains the six active states unchanged as in the traditional carrier based PWM. Fig.5. Block diagram of control scheme V. SAGAND SWELLCOMPENSATION OFPROPOSED SYSTEM A. Voltage Sag Compensation in DVR system Closed loop control operation is performed for the required value of the voltage as per need. The simulink model of closed loop control of voltage sag compensation in a DVR system is shown in the Fig.6. During the occurrence of a fault, the DVR system starts functioning so as to neutralize the error in the system. Initially the system was subjected to 25% voltage sag. The voltage during the period of sag is sent to subsystem 1 which is the rectifier part. The subsystem1 converts ac voltage to dc. Fig.6. Closed loop control of Voltage Sag Compensation in a DVR system In the Fig.7 subsystem 1 consists of resistor section and the AC output voltage is rectified to DC supply and then a reference voltage is given for the error. This error is sent to the PI controller. The saturator value is given out as pulses which are the input for controlling the Z- Source inverter. Pulse Width Modulation technique is used for controlling the firing pulses to the Z-Source Inverter. Fig.7. Subsystem 1of the Closed loop control of Voltage Sag Compensation in a DVR System JETIR1711054 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 293

Fig.8. Z-Source Inverter section of Closed Loop Control of Voltage Sag Compensation DVR system Fig.9. Simulation results of Closed Loop Control DVR under 25% sag (A. Uncompensated Voltage, B. Injected DVR Voltage, C. Compensated Voltage) In the Fig 8, the Z-Source inverter is controlled by the PI Controller. The Z-Source starts conducting when it obtains the pulse from the saturator. Fig. 9 shows the output waveform of closed loop control of voltage sag compensation. Fig. 9.A shows the uncompensated AC voltage with 25% sag. Fig. 9.B shows the injected DVR voltage. Fig. 9.C gives the compensated output voltage. Fig.10. FFT Analysis of Closed Loop Control of Voltage Sag Compensation in a DVR System In Fig.10, the Fast Fourier Transform (FFT) analysis is performed for the compensated output voltage. Here the Total Harmonic Distortion (THD) value is 7.21%. The simulation was done under transient performance at the sag appearance and recovery was observed. The load voltage is maintained at the same value throughout the simulation. Thus voltage sag compensation using closed loop control is simulated more precisely. A. Voltage Swell Compensation in DVR system The simulink model of voltage swell compensation using closed loop control in a DVR system is shown in Fig.11. Initially the system was subjected to 30% voltage swell. Subsystem 1 of the closed loop DVR system contains resistor section and the PI controller. The AC output voltage is rectified to DC voltage and then a reference voltage is given for the error signal. This error is sent to the PI controller. Sufficient value is set in the saturator for giving the pulses for controlling the Z-Source inverter. JETIR1711054 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 294

Fig.11. Closed loop control of Voltage Swell Compensation in a DVR system Fig.12. Subsystem 1of the Closed loop control of Voltage Swell Compensation in a DVR System Fig.13. Z-Source inverter section of Closed Loop Control of Voltage Swell Compensation in a DVR System Fig.14 shows the output waveform of closed loop control of voltage swell compensation. Fig. 14.A shows the uncompensated AC voltage with 30% swell. Fig. 14.B is the injected DVR voltage. Fig. 14.C shows the compensated output voltage. Fig.14. Simulation results of Closed Loop Control of DVR with 30% swell (A. Uncompensated Voltage, B. Injected DVR Voltage, C. Compensated Voltage) JETIR1711054 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 295

In Fig.15, FFT analysis is performed for the compensated output voltage. Here the THD value is 6.92%. The simulation was done under transient performance at the swell front and recovery was observed. The load voltage is maintained at the same value throughout the simulation. Thus voltage swell compensation using closed loop control is simulated. Fig.15. FFT Analysis of the Closed Loop Control of Voltage Swell Compensation in a DVR System VI. CONCLUSION DVR is an effective custom power device for mitigating voltage sag/swell in the distribution system. In case of external disturbances the proposed DVR injects appropriate voltage component to dynamically correct any deviation in supply voltage in order to maintain balanced and constant load voltage at nominal value.. In this paper Z-Source inverter based DVR is modeled and the same is installed in the distribution system to provide required load side compensation. The control technique is designed using in-phase compensation and used a closed loop control system to detect the magnitude error between voltages during pre-sag and sag periods. The modeling and simulation of closed loop control of voltage sag/swell mitigation were done using MATLAB software. The simulation results show that the developed control technique with proposed single phase DVR is simple and efficient. REFERENCES [1] M.H.J Bollen Understanding Power Quality Problems : Voltage sag and Interruptions New York IEEE Press,1999. [2] Choi S. S, Li B. H, and Vilathgamuwa D. M (2000) Dynamic voltage restoration with minimum energy injection, IEEE Trans. Power systems, vol. 15, pp. 51-57. [3] Gajanayake C. J, Vilathgamuwa D.M, and Loh P.C (2005) Small signal andsignal-flow-graph modeling of switched Z-source impedance network, IEEE Power Electronics Letters, vol. 3, pp. 111-116. [4] Jimichi T, Fujita H., and Akagi H. (2005) Design and experimentation of a dynamic voltage restorer capable of significantly reducing an energy storage element, in Conf. Record Industry Applications Conference, 14th IAS Annual Meeting. [5] Loh P. C, Vilathgamuwa D. M, Lai Y. S, Chua G. T, and Li Y (2004) Pulse-width modulation of Z-source inverters, in Conf. Record IEEE Industry Applications Conference, 39th IAS Annual Meeting. [6] Peng F. Z. (2003) Z-source inverter, IEEE Trans. Industry applications vol.39, pp. 504-510. [7] Miaosen Shen; Jin Wang; Joseph, A.; Fang Zheng Peng; Tolber; Adams, D.J.; Constant Boost Control of the Z-Source Inverter to Minimize Current Ripple and Voltage Stress Industry Applications, IEEE Transactions on Vol. 4 2006, PP: 770 778 [8] Torabzad S, Babaei E, Kalantari M (2010) Z-Source Inverter based Dynamic Voltage Restorer 1st Power Electronic & Drive Systems & Technologies Conference. JETIR1711054 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 296