LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers

Similar documents
LBC 3253/xx Intellivox 2c Active Line Array Loudspeakers

Datasheet. Applies to Part Numbers: / Intellivox - DC430

LBC 3200/00 Line Array Indoor Loudspeaker

LBC 3201/00 Line Array Indoor Loudspeaker

Vari directional Array

Datasheet. Applies to Part Numbers: / Intellivox - DSX280 HD

AXYS IndustryAmp PB-800

PB-400-CN. Datasheet. IndustryAmp PB-400-CN * Applies to Part Number: *This unit has a CobraNet interface installed

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed

Datasheet. Intellivox - HP-DS370* Applies to Part Number: Intellivox HP-DS370. Datasheet frontpage picture

Datasheet. IndustryAmp PB-800-CN * Applies to Part Number: *This unit has a CobraNet interface installed

XLA 3200 Line Array Loudspeakers

L1 Model 1S TECHNICAL DATA SHEET. portable line array system. Key Features. Product Overview. Technical Specifications

PLE 2CS Plena Two-zone Call Station

PRS xpxxx and LBB 4428/00 Power Amplifiers

FreeSpace DS 16F VA TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

CBT 50LA-LS. Beamwidth Technology Line Array Column Loudspeaker with Eight 50 mm (2in) Drivers

L1 Model I TECHNICAL DATA SHEET. portable line array system. AV-Concept - tlf web: Key Features.

AXYS UFM-265 data sheet rev 1.1 / GvB / Dec. 15 th 1995

FreeSpace DS 40SE TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

DSP AMPLIFIERS DI

AXYS T-2112 data sheet rev 1.1 / GvB / Dec.15 th 1995

FreeSpace DS 16SE TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

Intelligent Acoustic Solutions M E S S E N G E R G 2. D e l i v e r i n g Y o u r M e s s a g e

The AXYS Intellivox range

FOCUS-SERIES LINEA FOCUS DLI-130

LBC3200/00 Line array loudspeaker, 30W

LBC 34xx/12 Horn Loudspeakers

LBC 3201/00 Line Array Indoor Loudspeaker

LBC3201/00 Line array loudspeaker, 60W

LBC 3210/00 Line Array Indoor/Outdoor Loudspeaker

group D DSA250 Specifications 2-WAY FULL-RANGE DIGITALLY STEERABLE ARRAY See TABULAR DATA notes for details CONFIGURATION Subsystem Features

ZX1i-90. Electro-Voice ZX1i-90. Integrated QuickSAM Heavy-Duty Strong-Arm Mounting Bracket Included

CBT 70J-1. Beamwidth Technology Two-Way Line Array Column with Asymmetrical Vertical Coverage

The JBL Intellivox Range Beam Forming, Self Powered, Loudspeaker Arrays

data sheet MS-HM.01 AUDIO SYSTEM FOR INTEGRATION INTO MEDIA BOARDS

Dodecahedron Speaker Set

Amplifiers and battery charger

THE ART EVOLUTION CONTINUES

FreeSpace DS 40F flush-mount loudspeaker

FA12ac. Self-Powered 12 inch Coaxial Loudspeaker. product specification. Performance Specifications 1

FreeSpace IZA 2120-LZ Integrated Zone Amplifier

Panaray 302 A TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications. Bose Professional Systems Division 1 OF 6

datasheet TCS-40 TCS SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Dual 8 LF drivers Wide dispersion High power rating Down-fill enclosure

ArenaMatch AM20 DeltaQ array loudspeaker

Data sheet PT-6. Perform-Series Line-Array Systems.

AXYS UFM-265 data sheet rev 1.1 / GvB / Dec. 15 th 1995

ART300A SPEAKER ART300A A P P L I C A T I O N S 1 O F 6 P A G E S. Two-Way Active Speaker System. ART Series

RM28ac. Self-Powered Dual 8 inch Coaxial Reference Monitor. product specification. Performance Specifications 1

ZX1i-90 2-Way Passive Speaker Install

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

8000 Series. Operating Manual Genelec 8040A and 8050A Monitoring Systems

VLS 15. Technical Data Sheet. Product description. Features

not overpower the audience just below and in front of the array.

VQ 60. Product Description. Features. Applications

ART500A SPEAKER ART500A A P P L I C A T I O N S 1 O F 6 P A G E S. Two-Way Active Speaker System. ART Series

Intelligent Powered. Application: Fixed Installations Houses of Worship Schools Performing Arts Centers Civic Venues.

R SERIES Premium Music R.5-96MAX HIGH OUTPUT FULL-RANGE 90 x 60 WEATHER-RESISTANT LOUDSPEAKER

FA28. Dual 8 inch Coaxial Loudspeaker. product specification. Performance Specifications 1

SF 3PT SOUNDFIELD PENDANT SPEAKER SPEAKERS

PERMA Series Revision 2 Amplifiers

RoomMatch RM9060 TECHNICAL DATA SHEET. array module loudspeaker. Key Features. Product Overview. Technical Specifications

10" 2-WAY 2400 WATT LOUDSPEAKER WITH WIRELESS CONNECTIVITY

ALA15T(B) 1/8. Passive Column Line Array Loudspeaker. Features. Applications. General Description. AtlasIED.com

H90. Intellivox ADC-H90. Datasheet EN Shaping the future of sound reinforcement. Applies to Part Numbers: , and

Panaray 402 Series II TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

QFLEX 64-WP. # Fully integrated amplified speaker

SPECIFICATIONS QW -215

datasheet TCS-35 FEATURES APPLICATIONS Compact enclosure Wide dispersion Full range response OmniMount compatible Surround sound Background sound

datasheet TQ-310 QLIGHT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS CEW technology Trapezoidal cabinet Rotatable HF waveguide

SPECIFICATIONS QW -1. Listen To This. Mid Frequency Section: 101 db SPL, (2 Volt input) High Frequency Section: 111 db SPL, (2.

Twelve 2.25" (57mm) high-excursion, weather-resistant drivers. Powder-coated aluminum

ENTASYS HIGH PERFORMANCE COLUMN LINE-ARRAY SYSTEM

The QFLEX 8 is a powered, digitally steerable multi-channel, column array loudspeaker designed as a complete solution for installed

Low Frequency Section: 98.0 db SPL, (2.83 V input) High Frequency Section: db SPL, (2.83 V input)

Ray-On Acoustics meets Architecture

Overview. Features. Technical Data Sheet 1 / 7. Powered Loudspeaker DXR12

CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system.

StageSource L2m Compact, 2-Way Powered PA Speaker with Studio-Quality Sound

DESIGN AND APPLICATION OF DDS-CONTROLLED, CARDIOID LOUDSPEAKER ARRAYS

Operating Mode: PERFORMANCE Operating Range: Nominal Beamwidth: (rotatable) Horz 90 Vert 45 Axial Sensitivity (whole space SPL):

Operating Mode: PERFORMANCE 1 Operating Range: 57 Hz to 15 khz Nominal Beamwidth: (rotatable) Horz 120 Vert 60 Axial Sensitivity (whole space SPL):

SRM350v2 PRECISION ACTIVE LOUDSPEAKER. FEATURES: 2-way bi-amplified, optimized powered loudspeaker system APPLICATIONS

SA1521 SPEAKER SA1521 SA1521. Features. Applications Live Applications Playback Applications Portable PA Systems Corporate Events

FOHHN FOCUS VENUE BEAM STEERING FOR CONCERT SOUND THE FUTURE OF THE LINE ARRAY

Technical Guide. Installed Sound. Recommended Equalization Procedures. TA-6 Version 1.1 April, 2002

Panaray MA12EX TECHNICAL DATA SHEET. full-range modular line array. Key Features. Product Overview. Technical Specifications

FreeSpace IZA 250-LZ / 190-HZ TECHNICAL DATA SHEET. integrated zone amplifier. Key Features. Product Overview. Product Information.

NEMESIS NC-200A OPERATION MANUAL

7040A. Operating Manual Genelec 7040A Active Subwoofer

MediaMatrix X-Frame 88

12-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

EVID High Performance Ceiling Speakers

Bosch Plena Public Address Solutions A flexible approach to sound management

12-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

PS 260T DUAL CHANNEL AUDIO INTERFACE USER MANUAL

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

MK2399i Specifications

HP590i High Power Coaxial OpenCeiling Speaker. Nominal Impedance. Sensitivity 2.83V/1M Sensitivity 1W/1M (2)

TS212ac. Self Powered Dual 12 inch Direct-Radiating Subwoofer. product specification. Performance Specifications 1

Transcription:

Communications Systems LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers www.boschsecurity.com u u u u u Active Loudspeakers Variable Elevation Angle Variable Vertical Opening Angle Focus Distance Even Sound Pressure and Constant Directivity The Intellivox DDC (Digital Directivity Control) from Bosch Security Systems form a range of five active line array loudspeakers with unrivalled acoustical properties. Each loudspeaker produces clear, natural sound for excellent intelligibility of both speech and music. In addition, the audio characteristics of each line array can be adjusted by means of software to meet the acoustical requirements of the venue. This, along with the long acoustical reach ('throw'), means only a few loudspeakers are required for complete coverage. One loudspeaker can cover a distance of up to meters. The extensive integrated remote monitoring possibilities of Intellivox loudspeakers also make them extremely reliable and a key element in voice evacuation systems. Functions Active Loudspeakers All Intellivox loudspeakers have state-of-the-art class-d amplifiers as standard. This guarantees efficient and reliable operation without the need for external amplification. They also have an on-board DSP (Digital Signal Processor), which controls the frequency and delay time of each individual driver in the array, thus allowing software adjustment of loudspeaker characteristics like direction, opening angle and focus distance. As an added benefit, the presence of a DSP means there is no need for extra equalizers. Variable Elevation Angle Intellivox loudspeakers incorporate a feature known as Digital Directivity Control, which enables the direction of the main lobe to be tilted while the loudspeaker remains vertical. This is achieved by programming a different delay time for each individual driver in the array. As an example, by specifying a longer delay for the drivers at the bottom of the array, the lobe is effectively tilted downwards. These delay times, and therefore the elevation angle, are programmed into the on-board DSP using a PC. This feature gives much more mounting flexibility than conventional mechanical aiming. It also makes better use of the backward main lobe, because having the loudspeaker flat against a wall helps direct the sound from this lobe towards the listening area.

2 LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers Variable Vertical Opening Angle Being able to adjust the delay times and equalization settings for each driver in the array also makes it possible to specify the opening angle for all relevant frequencies. When the specified angle is narrow, sound can be pinpointed very accurately to a distant listening area. When the angle is wide, one loudspeaker can cover a very broad area. Focus Distance Intellivox loudspeakers are unique in allowing the loudspeaker focus distance to be set. The focus distance is the point at which the output of each driver in the array converges. Specifying the focus distance sets how far the main lobe reaches before the drivers contributions are out of phase and their sound energy becomes part of the diffuse sound field. Even Sound Pressure and Constant Directivity By accurately adjusting the direction of the sound and vertical opening angle, a main lobe can be created that has all relevant frequencies present at nearly the same sound pressure level. With Intellivox loudspeakers, the variation throughout the entire listening area is no more than 3 db. This means that the sound for listeners is not too loud at the front and not too quiet at the back. The constant directivity of Intellivox loudspeakers also helps ensure the presence of all relevant frequencies for more clear and natural sound. Suppressed Acoustic Side Lobes Intellivox loudspeakers produce extremely small side lobes, which gives a much clearer, less 'colored' sound, even when close to the loudspeakers. WinControl WinControl is a 32-bit Windows -compatible program that enables programming, testing and configuring of Intellivox units through the serial port of the PC. The software allows: Adaptation of signal processing-related parameters such as beam settings, gain, EQ, pre-delay and auto gain. Updating or restoring of the DSP software. Adaptation of surveillance-related parameters such as amplifier/dsp status, temperature overload and pilot tone detection settings. Requesting of the loudspeaker status for error checking purposes. Factory unit initialization. Integrated Remote Monitoring An Intellivox loudspeaker can be configured to notify a building management, control or evacuation system through in- and output relays if an error occurs. The loudspeaker cabling can be automatically checked using a 2 khz pilot tone. The status of each loudspeaker can also be continuously monitored via an RS-4 network. Over 1 different system parameters are checked - including temperature, pilot tone and amplifier condition - to guarantee system integrity. AVC (Automatic Volume Control) In certain environments, such as sport stadiums and passenger terminals, the background noise level fluctuates constantly. Intellivox loudspeakers are equipped with an external terminal for connecting a sensor (LBC 3262/) for measuring the ambient SPL. This information is used by the auto gain of the loudspeaker amplifiers to constantly adjust the loudspeaker output so it is always the same level above the ambient noise. Wall Mounting There are several options for mounting the Intellivox against a wall. It can be supported by means of the wall brackets supplied as standard, or by the LBC 32/ swivel bracket (adjustable through degrees) or the LBC 3271/ swivel bracket (adjustable through 45 degrees). Both swivel brackets have to be ordered separately. Safety and Evacuation Compliant The unrivalled speech intelligibility, reliability and extensive monitoring features of Intellivox loudspeakers makes them a key element in voice evacuation systems. With Intellivox, systems can be built that comply with both the technical requirements and acoustical demands of IEC 6849 and BS 5839. Certifications and approvals Region Certification Europe CE Declaration of Conformity Installation/configuration notes

3 LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers ❸ ❹ ❶ ❷ ❸ ❹ LBC 3252/ 1 Offset for acoustical mounting height on axis lowest speaker 2 Cable Entry 3 4xM5 threaded bushing at wall bracket positions. (can alternatively be used instead of wall brackets) 4 Drill position when wall brackets are used.

4 LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers ❸ ❹ ❷ ❸ ❹ ❶ LBC 3252/1 1 Offset for acoustical mounting height on axis lowest speaker 2 Cable Entry 3 4xM5 threaded bushing at wall bracket positions. (can alternatively be used instead of wall brackets) 4 Drill position when wall brackets are used. Acoustical Data Frequency 1 (Hz) DI 2 (db) Pac 3 (db PWL ) Horizontal coverage -6 db (deg) 2 125 2.5 111 36 332 25 4.9 111 36 Vertical coverage -6 db (deg) 2 5 8.4 112 255 38 1k 12.3 19 22 19 2k 16.7 16 129 1

5 LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers 4k 16.9 15 111 7 8k 18.6 99 6 7 25 ❶ ❷ 2 15 db db 1 5 Hz Hz 3 ❸ 2 24 21 1 deg15 6 3 Hz ❹ deg 6 5 4 3 2 1 Hz 1 Directivity index 3 Horizontal opening angle (-6 db) 2 Acoustical power 4 Vertical opening angle (-6 db) Settings: Elevation angle = deg, Opening angle = 1 deg, Focus distance = 2 m. 1. All values from octave band averaged data. 2. Only valid in the far-field (d > approx. 15 m), results from simulations, refer to general notes [2]. 3. Acoustical power (Pac) expressed in db PWL relative to 1-12 W, simulated with db SPL source level @ 1m on axis for each octave band, see general notes [2].

6 LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers 125 Hz 25 Hz 15 1 1 15 1 1 5 Hz 1 khz 15 1 1 15 1 1 2 khz 15 1 1 4 khz 15 1 1 Simulated Measured SPL Versus distance (on axis) Settings: Elevation angle = deg, Opening angle = 1 deg, Focus distance = 15 m. Simulations db SPL source level @ 1m on axis for each octave band, see general notes [2] Measurements scaled to simulation results at d = 1 m, zc = zli = 1.7 m, see general notes [1] for measurement details.

7 LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers 125 Hz 25 Hz 15 1 1 dbspl 15 95 1 1 5 Hz 1 khz 15 15 1 1 1 1 2 khz 15 1 1 4 khz 15 1 1 Simulated Measured SPL Versus Distance (Delta-z =,5) Settings: Elevation angle = -2 deg, Opening angle = 1 deg, Focus distance = 15 m. Simulations db SPL source level @ 1m on axis for each octave band, see general notes [2]. Measurements scaled to simulation results at d = 1 m, zc = 2.2 m, zli = 1.7 m see general notes [1] for measurement details.

8 LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers 125 Hz 25 Hz 3 2 1-1 -2-3 3 2 1-1 -2-3 4-4 4-4 5-5 5-5 6-6 6-6 - - - - - - - - - - - - 13-13 13-13 14-14 14-14 15 16 1 1-15 -16-1 15 16 1 1-15 -16-1 5 Hz 1 khz 3 2 1-1 -2-3 3 2 1-1 -2-3 4-4 4-4 5-5 5-5 6-6 6-6 - - - - - - - - - - - - 13-13 13-13 14-14 14-14 15 16 1 1-15 -16-1 15 16 1 1-15 -16-1 2 khz 4 khz 3 2 1-1 -2-3 3 2 1-1 -2-3 4-4 4-4 5-5 5-5 6-6 6-6 - - - - - - - - - - - - 13-13 13-13 14-14 14-14 15 16 1 1-15 -16-1 15 16 1 1-15 -16-1 8 khz 3 2 1-1 -2-3 4-4 5-5 6-6 13 - - - - - - -13 14 15 16 1 1-14 -15-16 -1 Horizontal Polar Data 1/1 octave averaged far-field data (r = m) Angular resolution 1 deg Scale 6 db/div Positive angles = left side (unit top view) Settings: - Elevation angle = deg - Opening angle = 1 deg - Focus distance = 2 m Simulations only

9 LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers 125 Hz 25 Hz 4 3 2 1-1 -2-3 -4 4 3 2 1-1 -2-3 -4 5-5 5-5 6-6 6-6 - - - - - - - - - - - - 13-13 13-13 14-14 14-14 15 16 1 1-15 -16-1 15 16 1 1-15 -16-1 5 Hz 1 khz 3 2 1-1 -2-3 3 2 1-1 -2-3 4-4 4-4 5-5 5-5 6-6 6-6 - - - - - - - - - - - - 13-13 13-13 14-14 14-14 15 16 1 1-15 -16-1 15 16 1 1-15 -16-1 2 khz 4 khz 3 2 1-1 -2-3 3 2 1-1 -2-3 4-4 4-4 5-5 5-5 6-6 6-6 - - - - - - - - - - - - 13-13 13-13 14-14 14-14 15 16 1 1-15 -16-1 15 16 1 1-15 -16-1 8 khz 3 2 1-1 -2-3 4-4 5-5 6-6 - - - 13 - - - -13 14 15 16 1 1-14 -15-16 -1 Vertical Polar Data 1/1 octave averaged far-field data (r = 2 m) Angular resolution 2.5 deg Scale 6 db/div Positive angles = top side Settings: - Elevation angle = deg - Opening angle = 1 deg - Focus distance = 2 m Simulations (line) and measurements (dots) refer to general notes [3]

1 LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers Vertical and Horizontal Beam Cross Sections Settings: Elevation angle = -2 deg, Opening angle = 1 deg, Focus distance = 15 m, Reference mounting height zc = 2.2 m. Simulations db SPL source level @ 1m on axis for each octave band, see general notes [4]. Dimensions of all vertical cross sections (top) m x 1 m. Dimensions of all horizontal cross sections (bottom) m x 2 m. Technical specifications Acoustical (1) Frequency range 2 Single element LF complete array Max SPL 3 23 to 1k Hz (±3 db) 13 Hz (-3 db) Continuous db SPL A-weighed with pink noise at 25 m

11 LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers Peak Coverage Horizontal (fixed) 4 94 db SPL at 25 m 15 deg Vertical (adjustable) 5 Opening angle: 8 to 2 elevation (aiming) angle: -16 to 16 focus distance: 5 to m Dynamic range 6 Electrical Input 7 Nominal level DLC threshold (1 khz) Type Impedance (balanced) DSP module 8 Type Memory ADCs DACs 88 db dbu (line input) and +5 dbu ( V input) +3 dbu, 6 db headroom before clip (gain / volume db) Transformer balanced 6.8 kohm (line input) and 2 Mohm ( V input) 32-bit floating point 32 k words SRAM, 2 x 8 kb EEPROM Two channel, 18 bit sigma-delta converters Eight channel, 18 bit sigma-delta converters Failure Power amplifiers Type PWM (class D) Power thermal overload protection - internal hardware bypass circuit - failure relay (external connector, maskable conditions) 8 x 4 W rms (4 ohm) Protection Thermal shutdown if T junction > 15 C Current limiting output stage Connectors General type Audio inputs RS-4 interface Ambient noise and temperature sensor Failure detect and fan control Mains 5 mm pitch cage clamp (as WAGO series 231) 6-pin male p1 = Line +, p2 = Line -, p3 = GND p4 = V +, p5 = V -, p6 = GND 5-pin male p1 = A, p2 = B, p3 = Z, p4 = Y, p5 = DGND 5-pin female p1 = MIC, p2 = AGND, p3 = NTC, p4 = AGND, p5 = GND 5-pin female failure relay: p1 = COM, p2 = NO, p3 = NC optional fan: p4 = -, p5 = +24 V 3-pin IEC Sample frequency 48.8 khz PSU Signal processing 9 pre-delay (< 335 ms @ 32 bit float) equalizer and compensation filtering compressor and noise gate volume and analog pre-gain ambient noise level dependent gain adaptation ( fail-safe ) eight output filters high resolution output channel delays (ΔT = 1.2 µs) Control unit Network interface type Maximum number of 126 units 1 Serial full-duplex RS-4, 19.2 kbaud, optically isolated Remote surveillance general status (DSP running, signal present etc.) amplifier monitoring and load monitoring schemes external pilot tone detection (2..3 khz, level > -22 dbv) ambient noise microphone monitoring frost protection fan control for optional external fan Mains voltage 23 or V (+5/-1%) 11 Mains fuse(s) Power consumption 12 Power factor. Max mains inrush current Mechanical Dimensions (H x W x D) 14 Weight Default color Transducers Environmental Operating temperature 13 Storage temperature 2 x 1.6 A (slow type) 28 VA (idle) / 15 VA (full load) 12 A short-time peak (@ 23 V) 17 x 134 x 92 mm 25 kg Silver Relative humidity <95% 12 x 4 full range -15 ºC to +4 ºC (5 ºF to +14 ºF) -4 ºC to + ºC (-4 ºF to +158 ºF)

12 LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers 1. Measured outside under semi-anechoic full-space conditions with typical filter and delay settings unless stated otherwise. 2. Single transducer only, from 1/3 octave averaged data at 1 m. Actual measured frequency response of complete array is depending on the actual signal processing parameters and air absorption (at larger distances). Only low frequency 3 db point is specified for complete array ( full-space ). 3. Continuous level: rms level measured with SLM (slow, A-weighed) with pink noise source level just below DLC input limiter threshold. Peak level: the maximum short-term A-weighed rms sound pressure level measured with a SLM and a pulsating pink noise source. 4. Settings: Elevation angle = deg, Opening angle = 15 deg, Focus distance = 1 m. 5. Opening angle -6 db, average value 1k - 4k Hz octave band. 6. Opening angle -6 db, typical values, only valid in the far-field (d > approx. 5 m). 7. For this measurement the signals at all power amplifier outputs are summed together. Measured as the A-weighed difference (in db) between the maximum rms level (with pink noise input signal) and the noise output (with no input signal present). 8. Specs valid for default type 3 input board, dbu =.7 V rms. Dual-line input available as an option. 9. Dual lobe and Extended pre-delay (up to 2684 ms) available as a DSP software / hardware option. 1. Maximum number that can be connected to one RS-4 subnet, multiple subnets can be controlled by one host PC. 11. Mains voltage can be selected on the IEC inlet, accessible from the outside of the unit. 12. Defined as the rms mains current multiplied by the rms mains voltage under normal operating conditions. Full load figures are maximum values measured with a pulsating pink noise input signal. 13. With frost protection and installed ambient temperature sensor. Outdoor versions available upon request. Without frost protection, lower limit: C. 14. Depth of enclosure only (including heatsink), without mounting brackets. Accessories LBC 326/ WinControl Software A 32 bit Windows-compatible program for configuring, testing and monitoring Intellivox. Order number LBC326/ LBC 3261/ Intellivox Dual Lobe Software Dual Lobe Software Order number LBC3261/ LBC 3262/ Ambient Microphone and Temperature Sensor Ambient Microphone and Temperature Sensor Order number LBC3262/ LBC 32/ Wall Mounting Bracket Bracket Order number LBC32/ LBC 3271/ Wall Mounting Bracket 45 Bracket 45 Order number LBC3271/ Ordering information LBC 3252/ Intellivox 2b Active Line Array Loudspeaker, Amplifier at Top Active Line Array Loudspeaker, Amplifier at bottom Order number LBC3252/ LBC 3252/1 Intellivox 2b Active Line Array Loudspeaker, Amplifier at Bottom Active Line Array Loudspeaker, Amplifier at top Order number LBC3252/1

13 LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers Represented by: Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina: Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division Portland Avenue South Burnsville MN 55337, USA Phone: +1--392-3497 Fax: +1--955-6831 audiosupport@us.bosch.com www.boschsecurity.com P.O. Box 2 5617 BA Eindhoven, The Netherlands Phone: + 31 4 2577 284 Fax: +31 4 2577 33 emea.securitysystems@bosch.com www.boschsecurity.com Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 28 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia 21 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 2335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Via Anhanguera, Km 98 CEP 1365- Campinas, Sao Paulo, Brazil Phone: +55 19 213 286 Fax: +55 19 213 2862 latam.boschsecurity@bosch.com www.boschsecurity.com Bosch Security Systems 215 Data subject to change without notice 191588319 en, V1, 1. Jul 215