VERCISE DIRECTIONAL SYSTEMS* VERCISE NEURAL NAVIGATOR 2.1 PROGRAMMING TUTORIAL

Similar documents
Spectra WaveWriter System Implantable Pulse Generator

Precision Spectra System Programming Manual

Boston Scientific Precision Spectra System Programming Manual

Precision Spectra OMG

Bionic Navigator 3D System Programming Manual

Bionic Navigator 3D System Programming Manual

PWM P108. Programming Instructions v 3.2 PWM Controller Software

Impact of Cycling Feature on Longevity and Recharge Interval Activa PC, Activa RC, and Activa SC

Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control

FAG PRESTO DX. FAG PRESTO-DX preliminary User Manual. FAG GRAPHIC SYSTEMS S.A. 3, rue de la Vigie CH-1003 Lausanne Switzerland

Wound Image Analysis Guide For Clinicians

EULAMBIA ADVANCED TECHNOLOGIES LTD. User Manual EAT-EOM-CTL-2. Alexandros Fragkos

Digital Function Generator

Universal Camera Registration User Guide for ILS 9.75 & 12.75

Planmeca Romexis. quick guide. Viewer EN _2

Physician s Manual. June VNS Therapy Programming Software Model 250 Version 11.0 Programming Computer. For Healthcare Professionals.

Minolta Scanner Plugin

VS7550 VUV/UV Mini Spectrograph Operating Manual

Physical Inventory System User Manual. Version 19

Progeny Imaging Veterinary

Introduction to the Analog Discovery

CURRENT. User Guide ACCESSORIES. External Sensor DT139. for MicroLog EC600 and EC mA ±0.1mA ±3% (before calibration)

WE-2705P Antenna Analyzer

Gentec-EO USA. T-RAD-USB Users Manual. T-Rad-USB Operating Instructions /15/2010 Page 1 of 24

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

Studuino Icon Programming Environment Guide

The CO2 Sensor Calibration Kit

LAB II. INTRODUCTION TO LABVIEW

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

LincView OPC USER GUIDE. Enhanced Diagnostics Utility INDUSTRIAL DATA COMMUNICATIONS

Progeny Imaging. User Guide V x and Higher. Part Number: ECN: P1808 REV. F

SCOUT Mobile User Guide 3.0

SourceXpress Waveform Creation Application Printable Help Document

MEDTRONIC CARELINK PROGRAMMER

ivu Plus Quick Start Guide P/N rev. A -- 10/8/2010

IX Feb Operation Guide. Sequence Creation and Control Software SD011-PCR-LE. Wavy for PCR-LE. Ver. 5.5x

Warehouse Instruction Guide

ZONESCAN net Version 1.4.0

September CoroCAM 6D. Camera Operation Training. Copyright 2012

5008 Dual Synthesizer Configuration Manager User s Guide (admin Version) Version valontechnology.com

ExpoM - ELF User Manual

LEDsmart + Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control

A Closer Look. LATITUDE NXT Alerts SUMMARY. Alerts. Red Alerts

Ansoft Designer Tutorial ECE 584 October, 2004

Vernier SpectroVis Plus Spectrophotometer (Order Code: SVIS-PL)

USER MANUAL ENGLISH 1450 COIN COUNTER & SORTER

Instructions for Use: Flexible Inspection Scope Camera

Section Table of Contents: Section 16.0

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

MANAGEMENT REPORT QUICK START GUIDE

Chanalyzer Lab. Chanalyzer Lab by MetaGeek USER GUIDE page 1

Accutome Connect Visual Aid

ZONESCAN net Version 1.4.1

VOLTAGE. User Guide ACCESSORIES. External Sensor DT140. for MicroLog EC600 and EC V ±0.05V ±3% (before calibration)

EE 210 Lab Exercise #3 Introduction to PSPICE

PROGRAMMABLE INTRACRANIAL SELF- STIMULATION (ICSS) CURRENT STIMULATOR

Fluke 125. Getting Started. Industrial ScopeMeter

HTC VIVE Installation Guide

Portable Multi-Channel Recorder Model DAS240-BAT

DXXX Series Servo Programming...9 Introduction...9 Connections HSB-9XXX Series Servo Programming...19 Introduction...19 Connections...

VNS Therapy System Overview and Dosing

MATRIX 430. Entry level guidance Software version 1.03

LV8716QAGEVK Evaluation Kit User Guide

Keypad Quick Reference

INTRODUCTION TO DATA STUDIO

Entering Checkpoint Data

Veterinary Digital X-Ray System Quick Start Guide

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

FLIR Tools for PC 7/21/2016

20 CHANNELS DIGITAL DELAY GENERATOR

FRAX Series Sweep Frequency Response Analyzers

STRUCTURE SENSOR QUICK START GUIDE

LIGHT STUDIO 485. Software Instrrctions Mancal. Read trhe mancal tarefclly before operaing trhis software

PSM Soft. Features and Functions January PC Software Guide. Getting connected and Communication

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

MIDLAND PROGRAMING G14

Cricut Design Space App for ipad User Manual

GD&T Administrator Manual v 1.0

Blue Bamboo P25 Device Manager Guide

Dual T/C & RTD Calibrator With Auto Stepping

Creating Retinotopic Mapping Stimuli - 1

Table of Contents. Chapter 1: Software Installation...1. Chapter 2: Running the Software II. Daily Practical Operation...10

OPERATOR S MANUAL FOR DMS 300-4A HOLTER ECG RECORDER

CHAPTER 18 DOCUMENT IMAGING MODULE 18.0 OVERVIEW 18.1 REQUIREMENTS AND INSTALLATION Special Requirements Mapping Network Drive

SPS1M-EVK. SPS1M-EVK Battery Free Wireless Sensor Handheld Evaluation System EVAL BOARD USER S MANUAL

APPLICATION NOTE. Computer Controlled Variable Attenuator for Lasers. Technology and Applications Center Newport Corporation

Introduction to Autodesk Inventor for F1 in Schools (Australian Version)

G7 System Certification Application Data Sheet

WPE 48N USER MANUAL Version1.1

Kodiak Corporate Administration Tool

2. Now you need to create permissions for all of your reviewers. You need to be in the Administration Tab to do so. Your screen should look like this:

Fluke 123/124 Industrial ScopeMeter

ACCU-GOLD QUICK START MANUAL

Smart Bus RRS. Quick Start Guide

knitcompanion NextGen for ios Reference Guide

Exercise 4. Angle Tracking Techniques EXERCISE OBJECTIVE

MIX SUITE + VOCAL BOOTH BASICS

Shelti, Inc. 333 Morton Street Bay City, MI Phone Fax. Bayside Dollar Bill Acceptor Pool Table Manual & Instructions

Sidexis 4 Sensor Plugin

era, eric, era-lora, eric-lora & eric-sigfox Evaluation Board with GNSS

Transcription:

VERCISE DIRECTIONAL SYSTEMS* VERCISE NEURAL NAVIGATOR 2.1 PROGRAMMING TUTORIAL *A System that includes the Vercise PC or Vercise Gevia IPG and Vercise Cartesia Directional Lead(s) form the Vercise Directional System. 92290382-02 Content: 92290396 REV A

TABLE OF CONTENTS VERCISE NEURAL NAVIGATOR 2.1 SETUP Vercise Neural Navigator 2.1 Setup... 1 Connecting the Programming Wand to the Clinician Programmer... 1 Starting a Programming Session... 2 Setting up the Stimulator... 3 Programming the Vercise DBS System... 6 Programming the Cartesia Lead... 6 Programming the Vercise Standard Lead... 9 Programming in Custom Mode... 10 Collecting Clinical Effects Data... 11 Reports... 12 CONNECTING THE PROGRAMMING WAND TO THE CLINICIAN PROGRAMMER (CP) 1. Power ON the CP and log into the ClinicUser account. 2. Plug the Wand into the CP using the provided USB cable. 3. When the Power Light on the Wand turns green, the Wand is ready to use. 4. Place the Wand over the Stimulator. STANDARD USB END POWER LIGHT 92290382-01 ii of ii MINI USB END 92290382-01 1 of 14

STARTING A PROGRAMMING SESSION SETTING UP THE STIMULATOR 1. 2. 3. 4. CONFIGURING THE LEADS Click on the Vercise Launcher icon. to start Vercise Neural Navigator 2.1. Select the Vercise Directional DBS Systems icon If the Wand is connected, the program will automatically try to connect to a Stimulator. When a connection is established, the following screen is displayed. 1. Once a connection with the stimulator has been established, switch to the Configure Tab. 2. Use arrow keys to access the drop down menus and identify the implanted lead(s) and brain hemisphere. Type in the brain target. CONNECTION STATUS LEADS CONFIGURATION 5. If a connection is not established, check the USB connections to the Wand and move the Wand closer to the Stimulator and Rescan. MEASURE BUTTON MEASURING IMPEDANCES RESCAN BUTTON Use the Measure button on the Configure or Program Tabs to measure lead impedances. In the Impedance Measurement Window impedances that are greater than 8000 Ω are displayed in yellow and may indicate an open. If values are shown in orange, than impedances are less than 200 Ω and may indicate a short. Contacts with impedances outside the acceptable range are marked with an Ω symbol. 92290382-02 2 of 14 92290382-02 3 of 14

PROGRAMMING SCREEN OVERVIEW PULSE WIDTH PROGRAMMING MODES SETTING STIMULATION PARAMETERS PULSE WIDTH AND RATE PROGRAM TAB Increasing and decreasing the Pulse Width The default setting for Pulse Width is 60 µs and the range is 20-450 µs. Use the buttons labeled Pulse Width to increase or decrease Pulse Width in 10 µs steps. and AREA PANEL RATE CONTACTS LEVEL AND AMPLITUDE S DIRECTIONAL S Increasing and Decreasing the Rate The default setting for Rate is 130 Hz and the range is 2-255 Hz. Select the Rate Button and choose the desire Rate from the table. Incompatible rates are greyed out. OPTIONAL PATIENT SETUP MEASURE IMPEDANCES STIMVIEW CLINICAL EFFECTS PANEL Programming with Different Rates The Vercise Directional DBS systems allow different Areas to be programmed with different rates. By default, the Multiple Rate option is Disabled. When you enable Multiple Rates, only the rates that are compatible with the rates and pulse widths from the other active Areas are available. Note: Areas that are assigned to the same Lead Port cannot have rates that sum up to greater than 255 Hz. Note: Modifying the rate of an Area will alter the available rates for the other Areas. Note: If you disable Multiple Rates, the rate for all Areas will be reset to the rate selected for the current Area 92290382-02 4 of 14 STIMVIEW TECHNOLOGY Visual representation of the DBS lead as well as the approximated stimulation field shown in red. 92290382-02 5 of 14

PROGRAMMING THE VERCISE DBS SYSTEM PROGRAMMING THE CARTESIA LEAD PROGRAMMING THE CARTESIA LEAD SELECTING STIMULATION AREAS 1. 2. 3. 4. With a new Program, an Area will be assigned to each Lead Port based on the Target and brain hemisphere selected in the Configure Tab. Add an additional Area by selecting an empty Area and choosing a Lead Port configuration. To reassign an Area select the Delete Button and choose a different Lead Port configuration. Configure up to four independent areas of stimulation per program. PROGRAMMING IN RING MODE Select Steering Mode Select contact(s) or level* that you want to program buttons Increase Total Amplitude with the and buttons to incrementally steer stimulation up and down or axially Use the along the length of the lead. 1. STEERING MODE 3. AMPLITUDE 4. AXIAL STIMULATION STEERING AREA PANEL DELETE BUTTON ADD AN AREA 2. SELECT CONTACT *Level refers to the focal point of stimulation along the axial plane of the lead. 92290382-02 6 of 14 92290382-02 7 of 14

PROGRAMMING THE CARTESIA LEAD PROGRAMMING THE VERCISE STANDARD LEAD SIMPLY ADVANCED PROGRAMMING 1. 2. 3. 4. One Touch Programming Use One Touch Programming buttons to quickly steer stimulation into one of four orthogonal directions or put the stimulation field into ring mode. Select Steering Mode Select contact that you want to program buttons Increase Total Amplitude with the and buttons to incrementally steer stimulation up and down or axially Use the along the length of the lead. 1. STEERING MODE ONE TOUCH PROGRAMMING BUTTONS 3. AMPLITUDE 4. AXIAL STIMULATION STEERING POSTERIOR ANTERIOR MEDIAL LATERAL Focus and Spread Spread stimulation across multiple contacts or narrow the focus to a single one. 2. SELECT CONTACT 100% SPREAD (0% FOCUS) MEANS RING MODE STIMULATION 100% FOCUS (0% SPREAD) MEANS ALL THE STIMULATION IS PLACED ON A SINGLE CONTACT. Rotational Steering Rotate stimulation around the lead in 30 increments with the 92290382-02 8 of 14 50% FOCUS (50% SPREAD) buttons. 92290382-02 9 of 14

CUSTOM MODE MAPPING THE PATIENT S CLINICAL EFFECTS OF STIMULATION Custom Mode allows you to assign anodic or cathodic stimulation to individual contacts and case. The Clinical Effect Panel allows you to note a therapeutic benefit and/or side effect at a given lead position and amplitude on a 0 (no effect) 4 (strongest effect) scale. Selecting a score for a therapeutic benefit and/or side effect plots a dot on the Clinical Effects Map at the lead position and amplitude. The color of the dot reflects the strength of the therapeutic benefit with 0 displayed as no color and 4 shown as a dark solid purple. Side effects are displayed as a orange ring around the dot. 1. Select Custom Mode 2. Select the case or contact that you want to adjust 3. The first tap will select the contact or case and each subsequent tap will cycle through the following assignments: ANODE(+) CATHODE (-) COLLECTING CLINICAL EFFECTS DATA OFF (BLANK) Selecting a dot will display a pop-up window containing the date and time at which the dot was captured along with the stimulation setting and effect details. and buttons to adjust the percentage of anodic or cathodic 4. Use the stimulation on the selected contact PROGRAMMING MODES You may also select the Text Notes button to enter and save up to 250 characters of text associated with each lead port. % OF CURRENT ASSIGNED TO CONTACT POP-UP WINDOW SUMMARY CLINICAL EFFECTS PANEL TEXT NOTES Note: Clinical effects data and associated settings are saved on the Stimulator and are available for review in the reports tab. The Clinical Effects Map is only available when programming the Vercise Standard Lead. 92290382-02 10 of 14 92290382-02 11 of 14

GENERATING REPORTS To generate a report for the current programming session, click on the Report Tab. A Report may be printed or exported as a pdf or csv file. Report options include: Program Settings Configuration Clinical Effects Maps Clinical Effects Details The user is able to select the desired information they want to include in the report. You can view reports for all Stimulators that were connected to the CP. Reports can also be viewed when the CP is not connected to a Stimulator. ENDING A PROGRAMMING SESSION The Patient s Remote Control Automatically syncs with the Stimulator that it has been linked to. No additional steps need to be performed to copy programs to the Remote Control. To end a Programming Session on the CP. 1. Select the End Session button. 2. Select Disconnect from Stimulator to end the programming session and disconnect from the patient s stimulator or select Exit Application. ESTIMATING BATTERY LIFE The Energy Use Index gives you an estimate of battery longevity for the selected program. After the optimal settings have been identified for a program, click on Battery in the Programs Options menu on the Program Tab to obtain the Energy Use Index. Use the Longevity Estimate Chart to identify the longevity that corresponds to this Energy Use Index. The figure takes into account nominal non-therapy power consumption, including shelflife and patient remote control use. If the estimate for longevity obtained is below 12 months, consider evaluating a Vercise Gevia DBS System. 12 10 8 Longevity, years 6 4 2 0 2.5 3.5 5 7 10 14 20 28 40 56 80 100 92290382-02 12 of 14 Energy Use Index 92290382-02 13 of 14

GUARANTEES Boston Scientific Corporation reserves the right to modify, without prior notice, information relating to its products in order to improve their reliability or operating capacity. TRADEMARKS All trademarks are the property of their respective holders. ADDITIONAL INFORMATION For indications, contraindications, warnings, precautions, adverse events summary, sterilization, component disposal and storage and handling, refer to the Information for Prescribers DFU for your Boston Scientific DBS System. For other device specific information not included in this manual or labeling symbols, refer to the appropriate DFU for your Boston Scientific DBS System as listed on your DBS Reference Guide. Legal Manufacturer Australian Sponsor AUS Address EC REP EU Authorized Representative Boston Scientific Neuromodulation Corporation 25155 Rye Canyon Loop Valencia, CA 91355 USA (866) 789-5899 in US and Canada (661) 949-4000, (661) 949-4022 Fax (866) 789-6364 TTY www.bostonscientific.com Email: neuro.info@bsci.com Boston Scientific (Australia) Pty Ltd PO Box 332 BOTANY NSW 1455 Australia Free Phone 1800 676 133 Free Fax 1800 836 666 Boston Scientific Limited Ballybrit Business Park Galway, Ireland T: +33 (0) 1 39 30 97 00 F: +33 (0) 1 39 30 97 99 2018 Boston Scientific Corporation or its affiliates. All rights reserved. 92290382-02 14 of 14 2018-10