Well Casing Cathodic Protection - Design Issues, Lessons Learned and a Case History

Similar documents
Technical Seminar for Cathodic Protection to GOGC Design Unit Specialists. Dr. Nick Kioupis, Cathodic & Lightning Protection Section Head, DESFA

Static Stray DC Current Interference Testing

Electrical TP-18 February 2017 ELECTRICAL TECHNICAL PAPER 18 FREQUENTLY ASKED QUESTIONS ABOUT CATHODIC PROTECTION SYSTEM EQUIPMENT TESTING

AC Voltage- Pipeline Safety and Corrosion MEA 2015

Cathodic Protection & Monitoring

PREDICTION OF INTERACTIONS BETWEEN FPSO AND SUBSEA CATHODIC PROTECTION SYSTEMS

ENGINEERING REPORT PHASES I & II MITIGATOR PERFORMANCE TESTS

MAGNETOMETER-BASED MEASUREMENTS OF STRAY CURRENT DISTRIBUTION ON CATHODICALLY PROTECTED GAS TRANSMISSION PIPELINE

Examples of Design for Cathodic Protection Systems

ECDA to assess possibility of AC Corrosion. Mark Yunovich Honeywell Corrosion Solutions January 27 th, 2009

DCVG Coating Survey Data Sheet

ICCP Retrofit Challenges for an Offshore Jacket Complex

Monitoring DC Decoupling Devices at Isolation Flanges for Compliance and Pipeline Integrity

Be a Differentiator in Management of Well Integrity and Risk for Deepwater O&G Wells

Subsea Intervention: Is It Worth It? Drummond Lawson

Surface Potential Surveys Training Manual DA Meter Version

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

FE014: Cathodic Protection Systems: Design, Fabrication, Installation, Operation & Repair

Identification and Control of Impressed Current Cathodic Protection System

The Lease Pumper s Handbook. Chapter 4 Understanding the Oil Well. Section B DRILLING OPERATIONS

OVERCOMING THE NEW THREAT TO PIPELINE INTEGRITY - AC CORROSION ASSESSMENT AND ITS MITIGATION -

CIPS, DCVG & GPCM Pipeline Surveyor. Corrosion Control Equipment

60Hz Ratings. Typical Applications. Features & Characteristics. Ratings

Predicting the performance of cathodic protection systems with large scale interference

Chapter 02. Casing and Tubing

An Introduction to Oil & Gas Drilling and Well Operations

CATHODIC PROTECTION FIELD TESTING

Cathodic Protection Close Interval Surveys. Field Manual. Prepared by R.L. Pawson

Specialists in HV and MV test and diagnostics. Testing in Substations

FIELD CASE STUDIES: CATHODIC PROTECTION SYSTEMS

Operators Manual: Diamond Rock Saw Excavator Attachment Austramac Flashcut Series

TDI White Paper UPS Systems for Non-Environmentally Controlled Environments

37 th Gas-Lift Workshop Houston, Texas, USA February 3 7, Dag Almar Hansen, CEO Gas-Lift Workshop 1. Feb. 3-7, 2014

Learn more at

Using Remote Data-Logging Techniques to Evaluate Transit System Interference

PIPELINE CORROSION RISKS ASSOCIATED WITH AC VOLTAGES

TRANSFORMER RECTIFIER INSTALLATION FOR THE TANGIER MED PORT II PROJECT

Well Integrity During Drilling Operations

Jim Britton Deepwater Corrosion Services Inc. Houston, TX. UTC 2008 Bergen

BRACE ASSEMBLIES FOR WIRE FENCES. What They Are - How They Work - How To Construct Them

MODEL PD PEARSON DETECTOR

SAFER, SMARTER, GREENER

Edgerail Aluminum Bridge Railing System Specification & Installation Instructions

Unirac Installation Manual

WAY AHEAD IN CORROSION CONTROL OFFSHORE WIND. stoprust.com

MINING EARTH LEAKAGE PROTECTION WITH VARIABLE SPEED DRIVES

WATERFLUX 3000 Quick Start

DCVG Training Manual DA Meter Version

Operation Manual for CTL-3000

Application of FRP Pipes & Other Composites in Oil & Gas Sector: Opportunities and Challenges

M. Kevin McEvoy. Oceaneering International, Inc. President & CEO. December 2, 2014 New York, NY. Safe Harbor Statement

ANALOG RESISTANCE METER USER S MANUAL

Increased Safety & Efficiency from a Dedicated Light Well Intervention Vessel on Deepwater Subsea Wells

Ring Pair Corrosion Monitor : RPCM

2017 Award Nomination Title of Innovation: Wells Materials Design & Performance enhancement

Implementing a Deepwater- Pipeline-Management System

Recent advancement in well-control technology improves safety and allows cost savings for well designs

The Marine Well Containment System. LSU Center for Energy Studies Energy Summit 2010 October 26, 2010

GWF-1 Development DrillWell

ANALOG RESISTANCE METER

EUOAG Workshop. Workshop on decommissioning of offshore installations Challenges, options and lessons learned PP&A

Asset Protection Cathodic Protection Soil Resistivity Measurement. Work Instruction No.:

OFFSHORE CATHODIC PROTECTION AND INTEGRITY

WRS Artificial Lift System

Subsea UK Neil Gordon Chief Executive Officer Championing the UK Subsea Sector Across the World

Runcorn: A Project First for Europe

A Comparison of Active and Passive Magnetic Ranging Techniques in a Relief Well Application

WATERFLUX 3000 Quick Start

Wintershall Production Optimisation Initiative Value Creation through Innovation. Michael Damm Wintershall Noordzee BV

Practical Lightning Mitigation

A. Deviation from this standard must be approved by the Project Architect.

Global Subsea University Alliance: Subsea education and research programs. Prof Brian Evans Curtin University, Perth Australia

Model: SS660-PT-R Stainless Steel Poly-Top Floor Scale Series. Installation, Set-Up and Operation Manual

NAVSEA STANDARD ITEM

Troubleshooting Guide for Aquatrac Smart AS and Flex

Pennsylvania's Natural Gas Industry & The Jobs It Creates

Standard Recommended Practice. Mitigation of Alternating Current and Lightning Effects on Metallic Structures and Corrosion Control Systems

GTSC Rig for Hands-on Training

NAS Real-Time Monitoring of Offshore Oil and Gas Operations Committee Todd Durkee Director of Deepwater Drilling & Completions

Installation of vibration sensors

Deepwater Precommissioning Services

NTL No N06 Information Requirements for EPs, DPPs and DOCDs on the OCS Effective June 18, 2010

Building A Simple Wooden Emergency Radio Go-Box

Predictive Subsea Integrity Management: Effective Tools and Techniques

SunPower Installation Manual

DCVG Training Manual G1 Version

ELECTRICAL SURVEY METHODS OF UNDERGROUND COATED PIPELINES

DrillWell Drilling and Well Centre for Improved Recovery

THÖRESS F2A11 Stereo Integrated Amplifier...

Report. Temporary abandoned wells on NCS. Subtitle. Author(s) Nils Totland. SINTEF Petroleum Research Well Integrity

S6 User s Manual USER S MANUAL ver. 1.0

Catalog October Speedi-Sleeve The quickest and most economical way to repair worn shafts

Single / Dual Barrier HP Drilling Risers

Subsea Pipeline IMR. PT Hallin Marine June 18 th, 2014!

Semiconductor theory predicts that the current through a diode is given by

9. Pay for the power consumed until the project has been accepted as substantially complete.

From late-life reservoir management through to final permanent abandonment, we create bespoke solutions to meet your specific well requirements.

Tony Owen, Subsea and Pipelines Decommissioning Delivery Manager AOG February 2017

Wire EDM Fundamentals

The Essentials of Pipeline Integrity Management

Transcription:

Well Casing Cathodic Protection - Design Issues, Lessons Learned and a Case History Jeffrey L. Didas Matcor, Inc. 101 Liberty Lane Chalfont, PA 19111 USA WRGC Western Regional Gas Conference 2018 Henderson, NV USA

Overview Introduction Discussion Design Issues Case History Lessons Learned Conclusions Wrap Up & Questions

Introduction The use of cathodic protection CP for protecting the external steel surfaces of well casings is a proven technique to reduce or minimize external corrosion. Production wells and storage wells utilize cathodic protection and it is quite successful in stopping or minimizing external corrosion. The need for CP on well casings does depend on many factors, primarily economics, corrosive electrolyte in contact with the casing, corrosion cells - long line and localized and stray current interference. The goal of installing CP for well casings is to prevent casing leaks.

Well Casing and Pumpjack

Discussion Cathodic protection has been used for protecting well casings from external corrosion for decades. The process is simple but the application can be complex. The primary purpose is to prevent casing leaks. A casing leak on a production or storage well is an expensive repair that can be minimized via the application of CP. Economics: The primary reason for most owner/operators is economical. Every well has a design life and depending on the life, the time to leak is determined and if less than the design life installing CP becomes economical as it will prevent leaks for the design life of the well. If the well has a finite life and the time to leak is greater than the finite life then CP may not be necessary. The issue is most wells are run beyond their design life and enter the time to leak zone. Many owner/operators realize this or operate storage wells which have a long life well beyond the predicted time to leak and CP becomes a viable economic option.

Discussion - continued Cathodic protection can be used for protecting various types of wells and their casings from external corrosion. This includes oil and gas production wells, storage wells for natural gas and natural gas liquids, salt dome storage well casings, observation wells, monitor wells, water wells, disposal or injection wells and special wells. A casing leak on any well is an expensive repair that can be minimized via the application of CP. Logistics: Applying CP to a well casing is normally a fairly simple process. Install a cathodic protection anode bed (deep or surface) and connect it to a DC power source and the power source to the well casing. The process gets complicated when determining which power source to use, where to locate the anode bed, how to address the flow line from the well, how to address the other utilities in the vicinity and how to address the ongoing operations and maintenance costs for the CP system. That s is where the corrosion control professionals are needed.

Typical Wellhead Well Casing Isolation Flange FLOWLINE SAND & FRESH WATER WELL CASING SANDSTONE & SALT WATER LIMESTONE

Corrosion Issues CP Can Solve These Issues External corrosion: Well casings leak due to external and internal corrosion. CP will minimize or stop external corrosion. The forms or processes of external corrosion are as follows: Long Line Corrosion current flowing in different directions or off the well casing due to the different formations that the well casing traverses. This current flow causes corrosion when the current departs the well casing. Localized Corrosion current flowing off and on the casing at couplings with exposed threads or formation changes due to high/low resistivity.

Corrosion Issues - continued Stray Current various stray current sources predominately foreign CP current or the owner/operators pipeline/flowline/tank bottom CP systems can cause stray current. Casing Installation the installation of the casing can also cause corrosion depending on the handling of the casing and the method of installation as accidental removal of the casing varnish, tongs and chains can remove varnish and scratch the external surface and corrosion can result. Also, the mixture of the drilling mud can contain various materials such as chlorides, sulfides or some additives which will create a corrosive environment, a low resistivity environment or both.

CP Design Issues Electrical Isolation of well flow line. This is mandatory if one is providing CP for the well casing. This allows the majority of the CP current to go to the well casing as well as minimize any stray current pick up on the flow line. Connecting the rectifier negative cable directly to the well head/well casings. Connecting the negative directly to the casing again allows the majority of the CP current to flow onto the casing and return via the direct connection. It provides a low resistance path. This can be critical as we want the CP current to flow up the casing to the negative cable and return to the rectifier. Electrical continuity of the surface casing, production casing, tubing, etc. Electrical continuity between the well components at the wellhead is also critical as this will minimize CP current passing between the components downhole. Electrical continuity at the wellhead and a separate negative cable at the wellhead will allow the majority of the CP current to travel up the casing and to the negative return.

Determining current requirement of the well casing The level of current milliamps per square foot of surface area needs to be determined. This is based on what the soil conditions are downhole, the temperature of the product, variation in the formations the well casing transgresses and reviewing the drilling log if available. The typical ranges go from 1 to 3 milliamps per square foot with 2 milliamps as the most common. Then the actual CP current required can be calculated several ways: Calculating the actual surface area of the casing and then multiplying it by 2 milliamps per square foot. Performing E log I testing on the well casing to get an actual current value. Running a casing potential profile log using a temporary CP source to get an actual current value.

Well Casings The Early Days

CP System Design Issues Well casings are typically protected with an impressed current CP system either a remote surface anode bed or a deep anode. The optimum location for the surface anode bed/deep anode is at remote earth. At remote earth, the anode bed/deep anode provides the best current distribution for the entire well casing. If installed too close to the well casing, then poor current distribution will result. Typically, remote earth is obtainable at approximately 500 feet from the structure. Two issues arise when determining which type of CP system surface anode bed/deep anode and the location for the anode bed. Area required for a surface anode bed length and width. Procuring area for a remote anode bed - deep or surface distance from structure.

Design Issues - continued AC power Multiple well casings on the same drilling pad Deep anode depth vs. current distribution CP Interference Cellar at Wellhead

Current Distribution Current Distribution Deep Anode Bed RECTIFIER Current Distribution Remote Anode Bed RECTIFIER - + LOW RESISTIVITY HIGH RESISTIVITY - + DEEP ANODE BED REMOTE ANODE BED LOW RESISTIVITY WELL CASING WELL CASING

Case History Multiple wells on one pad and a single CP system. Balancing the CP System Adding Resistance Negative Control Box Low Resistance Path Casing Leak

Background A producer installed a single well on a well pad. The CP system was designed to accommodate 3 future wells being installed on the same pad. The CP system was rated 50 DC amperes and used a deep anode installed 100 feet from the well. Over the next few months 3 additional wells were installed on the pad and all were tied into the CP system. Each well had had a negative cable installed and run to the rectifier. The rectifier had a four-circuit negative junction box installed so all the well casing CP current returns could be monitored.

Background - continued Initially for well #1 the CP system was set at 10 amperes. The design current was 8.7 amperes. As the 3 additional well casings were tied into the CP system, the current output of the rectifier was increased in 10 ampere increments until the rectifier ended up operating at 49 amperes. After some time, the local corrosion engineer got involved and took some shunt readings at the negative junction box and found the following: Well #1-22 amperes Well #2-16 amperes Well #3 6 amperes Well #4-5 amperes

Background - continued After a few months, the corrosion technician and the contract corrosion engineer evaluated the CP system at the four well pad and realized they had quite an imbalance in the negative return current and two of the well casings were not receiving adequate CP current. A decision was made to install a negative control box and replace the negative junction box. A negative control box is basically a negative junction box with resistors installed for each circuit. The rectifier was also adjusted to a DC output of 44 amperes.

Background - continued The negative control box was installed and resistance was added to the well #1 negative return and the current flow reduced from 22 amperes to 11 amperes. The return current from the four wells was now: Well #1 11 amperes Well #2 18 amperes Well #3 8 amperes Well #4 8 amperes

Typical Negative Control Boxes

Background - continued Resistance was then added to the well #2 negative return and the current reduced to 10 amperes. The return current from the four wells was now: Well #1 12 amperes Well #2 10 amperes Well #3 10 amperes Well #4 11 amperes The rectifier was running at 44 amperes. The technician reread the negative control box one year later and the outputs were about the same.

Background - Continued Six months later well #1 had a leak. The well was shut in and the tubing and casing pulled and a 100-foot section of the casing was found to have severe pitting corrosion. The cause appeared to be the CP current was discharging from well #1 to wells #3 & #4 through the soil. This location had a fairly low resistance formation and the CP current was flowing through that path to return the CP current to the rectifier. The path had a much lower resistance than the resistance of the control box resistor.

Lesson Learned Do not install too much resistance in a CP circuit as the CP current will always find the lowest resistance path back to the current source. Solution that was designed and commissioned by the new contract corrosion engineer was to install a new deep anode at remote earth from the wellheads approximately 500 feet away. The deep anode was installed at a depth of 400. The negative control box and the existing deep anode was abandoned and a new negative junction box installed at the rectifier with NO resistors.

Lesson Learned - continued The current distribution was the following for the new CP system: Well #1 10 amperes Well #2 11amperes Well #3 10 amperes Well #4 10.5 amperes Rectifier current output was at 43 amperes. Cost of this corrosion failure - $1.2 million dollars Cost to install a properly designed CP system - $42,000. Note: Well #2 was also shut in some time later and inspected and severe (but no failure yet) corrosion was discovered at the same zone as the well #1 failure. Casing and tubing were replaced as part of routine maintenance.

Conclusions Cathodic protection of well casings is a practical and economical method of minimizing or even stopping corrosion. The concept is not complex; however, the application, design and installation are complex and need to be performed by a competent CP professional.

Wrap Up and Questions Comments - Discussion NACE SP0186 - Application of Cathodic Protection for External Surfaces of Steel Well Casings needs to be utilized to achieve a successful result.