Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement

Similar documents
APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Smart Pressure Transmitter

Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Series Smart Pressure Transmitter

PAD - Heavy Duty Differential Pressure Trasmitter

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

ATT2100/2200 SMART TEMPERATURE TRANSMITTER. Application Areas: ATT 2200 ATT2100

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

General Specifications

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

SMART TEMPERATURE TRANSMITTERS. smar

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

The Rosemount 848T Wireless Temperature Transmitter

General Specifications

Field IT 2600T Series Pressure Transmitters

Alphaline Temperature Transmitters

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

DRS390 High stability, flange mounting

General Specifications

AT9000 Advanced Transmitter Differential Pressure Transmitters

A New Generation of Pressure Transmitters

General Specifications

General Specifications

Model 3244MV MultiVariable Temperature Transmitter with Profibus-PA

AT9000 Advanced Transmitter Gauge Pressure Transmitters

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

General Specifications

A New Generation of Pressure Transmitters

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

FUNCTIONAL SPECIFICATIONS

AT9000 Advanced Transmitter Gauge Pressure Transmitters

Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span

Differential Pressure Transmitters

General Specifications

URV LRV. Smart Field Communicator. Can be ordered separately see specification 34-ST-03-55

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f

LGP Design. Can be ordered separately see specification 34-ST-03-55

PTG series Smart Pressure Transmitter

General Specifications

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

ABSOLUTE PRESSURE TRANSMITTER

Compact Orifice Flow Meter

Rosemount 2088 Absolute and Gage Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Model 3244MV. MultiVariable Temperature Transmitter with Profibus PA. Product Data Sheet

General Specifications

General Specifications

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

General Specifications

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

General Specifications

Level Measurement Continuous level measurement Radar transmitters

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

General Specifications

LGP Design. Can be ordered separately see specification 34-ST-03-55

Absolute Pressure Transmitters

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

Rosemount 248 Wireless Temperature Transmitter

ED701 General Industry Pressure Transmitter

General Specifications

General Specifications

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Magnetic Flowmeter Systems

AT9000 Advanced Transmitter Gauge Pressure Transmitters

TIY Programmable, Isolated Thermocouple Transmitter combines

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

General Specifications

Absolute Pressure Transmitters

General Specifications

URV. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

General Specifications

FKG... 5 PRESSURE TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

STT 3000 Smart Temperature Transmitter

General Specifications

General Specifications

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple

RCM DIRECT READING FLOWMETER

Smart Displacer Level (Interface) Transmitter DLT100 Series

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

SATRON VB Pressure Transmitter

General Specifications

General Specifications

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Micro MV P2DAAA. Custody transfer accuracy Built-in multivariable 3-in-1 transmitter. Daily. Zigbee wireless radio. Extended length battery backup

General Specifications

SITRANS T measuring instruments for temperature

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Accessories for EST4 Series

600T EN Series Pressure Transmitters. Specification sheet. Model 624ES gauge/absolute with direct mount seal for pulp & paper application

SITRANS P. Transmitters for level. Introduction 1/42. Application

Transcription:

Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement

MODEL 31 Function Description of Product The 31 Smart Pressure Transmitter is a micro processor-based high performance transmitter, which has flexible pressure calibration and output, automatic compensation of ambient temperature and process variable, configuration of various parameters, communication with HART protocol. The application is very various, as measuring liquid, gas or steam flow as well as pressure and liquid level by application method. All data of sensor is to be input, modified and storedin EEPROM.» Flexible Sensor Input : DP, GP, AP, HP» Various Output : ~0mA, Digital Signals»Setting Various Parameters : Zero/Span, Trim, Unit, Fail-mode, etc.»self Diagnostic Function : Sensor, Memory A/D Converter, Power, etc» Digital Communication with HART protocol» Explosion-proof Approval & Intrinsic Safety Approval : ATE, FM, FMCanada, GOST, KOSHA, KTL, etc.» Marine Certificate: ABS, LR, BR, DNV Functional Block Diagram MCU Part Sensor Part A/D Conversion EEPROM sensor High Pressure User-Selectable Input DP/GP/HP/ AP Measuring Range Microprocessor Input Sensor Value Engineering Units Re-range (Zero / Span) Sensor Trimming Zero Point Adjustment DA Trimming Damping / Filtering Transfer function LCD Engineering Mode Diagnostics Self Compensation Communications LCD Display Configuration Data -0mA DAC HART HART Protocol with Host

Features» Superior Performance High Reference Accuracy : ±0.075% of Calibrated Span (The option : ±0.0% of Calibrated Span) for range ±0.5% of Span for 0.1URL Span URL ±[0. + (0.00 x (URL/span))]% of Span for 0.05URL Span < 0.1URL for range 3 ±0.075% of Span for 0.1URL Span URL ±[0.05 + (0.005 x (URL/span))]% of Span for 0.0URL Span < 0.1URL for ranges to 0 ±0.075% of Span for 0.1URL Span URL ±[0.05+(0.005 x (URL/span))]% of Span for 0.01URL Span 0.1URL Long-Term Stability (0.15% URL for 3year) High Rangeability (100 : 1)(for the range -0)» Flexibility Data Configuration with HART Configurator Zero Point Adjustment» Reliability Continuous Self-Diagnostic Function Automatic Ambient Temperature Compensation Fail-mode Process Function EEPROM Write Protection CE EMC Conformity Standards (EN5001-, EN500-) Transmitter Description 31 Pressure transmitter can be easily configured from any host that support the HART protocol.» Basic Setup Operational Parameters. ~0mA Points (Zero/Span) Engineering Units Damping Time : 0.5 ~ 60 sec Tag : alphanumeric characters Descriptor : 16 characters Message : 3 characters. Date : day/month/year» Calibration and Trimming Lower/Upper Range (zero/span) Sensor Zero Trimming Zero Point Adjustment DAC Output Trimming Transfer Function Self-Compensation» Self-Diagnosis and Others CPU & Analog Module Fault Detection Communication Error Fail-mode Handling LCD Indication Temperature Measurement of Sensor Module Function» Range and Sensor Limits Refer to Table 1.» Zero and Span Adjustment Limits Zero and span values can be set anywhere within the range limits stated in Table 1.(Page 9) Span must be greater than or equal to the minimum span stated in Table 1.(Page 9)» Output (Analog Current and Digital Data) LCD Display & ENG Mode Two wire ~0mA user-configurable for linear or square root output, digital process value superimposed on ~0mA signal, available to any host that conforms to the HART protocol» Power Supply & Load Requirement External power supply required. * 50 ohm load-- 17.5 Vdc * up to a 550 ohm load -- Vdc Max. Loop Resistance = ( E - 1 ) / 0.0 (E = Power Supply Voltage) Voltage Range : 1 to 5 Vdc Voltage Rating : Vdc ±30% Loop Load 0 ~ 1500 ohm -- Operation 50 ~ 550 ohm -- HART Communications» EMC Conformity Standards EMI (Emission) EN5001-:1993 EMS (Immunity) EN500-:1995» Failure Mode Fail High : Current 1.1 ma Fail Low : Current 3.7 ma» Storage Temperature -0 to 5 (without condensing)» Process Temperature Limits (Range codes and approval codes may effect limits) -0 to 10 ( -10 to )

Function» Isolation Input/output isolated to 500Vrms (707 Vdc)» Working Pressure Limits (silicone oil) Model D & G 0 ~ 13.79 MPa - # 3 ~ Model G 0 ~ 0.00 MPa - # 9 0 ~ 75.00 MPa - # 0 Model H 0 ~ 31.0 MPa - # ~ 7 Model A 0 ~ 55 KPa - # 0 ~ 3000 KPa - # 5 0 ~ 550 KPa - # 6» Change main parameter by Button Change Unit Change Upper range value Change Lower range value Change the Damping Second Select the Decimal Place Zero Trim Zero Adjustment» Hydrostatic Test Pressure Model D 3000 psi (0.7 MPa) Model H 6750 psi (6.5 MPa) Model G 000 psi (13. MPa) - # 3 ~ 11600 psi (0 MPa) - # 9 11600 psi (0 MPa) - # 0 Model A 101.5 psi (700 KPa) - # 50 psi (000 KPa) - # 5 1015psi (7000 KPa) - # 6» Burst Pressure Model D, G, H 6.9 MPa G~9 50 MPa G0 0 MPa Model A 1050 KPa A5 000 KPa A6 7000 KPa Moving within Menu : Zero Moving to below Menu : Span Moving Top Menu : Zero+Span» Button Manu Tree» 5 Digit LCD Express all pressure unit and flow unit. Use 5 digit. Select decimal place (0 to )» User define unit function

Physical Specifications» Wetted Materials Isolating Diaphragms, Monel, Tantalum, HAST-C Drain/Vent Valves, HAST-C Flanges and Adapters (ASTMCFM), HAST-C O-ring Viton, PTFE» Non-wetted materials Fill Fluid Silicone oil or Inert fill Bolts 30 SST Electronics Housing Aluminum or (Option) Flameproof and Waterproof (IP67) Cover O-ring Buna-N Paint Epoxy-Polyester or Polyuret Mounting Bracket 30SST with U-bolt (30SST) for -inch pipe Nameplate 30SST Exploded drawing of Model 31» Electrical connections 1/-1 NPT conduit with M Screw Terminals» Process Connections 1/-1 NPT on.16 inch (5.0 mm) centers on flanges for Standard 1/-1 NPT on Process Adapter (option) * Refer to drawing in the last page» Weight 3.9 kg ( Standard - excluding options ) 5.35kg (SST Housing- excluding options) 30 SST

Hazardous Location Certifications (option)» KOSHA Approvals K1 Code : * KOSHA: Korea Occupational Safety & Health Agency Flameproof for Class I, Zone 1 : Ex d ⅡC T6, IP67 Ambient Temperature : -0 to 60 C Max. Process Temperature : 0 C Power Supply : Max. 5 Vdc Output : to 0 ma + HART, Max. ma» ATE ApprovalsE1 Code : CE 03 II G Ex d IIC T6, T5 or T Operating Temperature: -00C Tamb +6 0 C T6 for process 50C ; T5 for process 100 C T 1300C APT3100 ATE Certification is according to the below standards : EN 60079-0 : 006 EN 60079-1 : 007» KTL Certification K Code : * Intrinsic Safety: Ex ia IIC T6 Ambient Temperature : -0 to 600C Ui=30Vdc, Ii=00mA, Pi=0.9W, Ci=7nF, Li=9μH» FM and FM Canada Approvals F1 Code : * FM: Factory Mutual explosion proof * FM Canada: Canadian requirements Explosion proof for Class I, Division 1 Groups A, B, C and D Dust-ignition proof for Class II/III, Division 1, Groups E, F and G Nonincendive for Class I, Division, Groups A, B, C & D; Class II, Division, Groups E, F & G; and Class III, Division 1, Enclosure: indoors and outdoors, NEMA Type Connection Diagram of Signal, Power, HHT for Transmitter 1.. 3. HHT (HART Communicator) or PC Configurator may connected at any termination point in the signal loop. HART Communication requires a loop resistance between 50 and 550 ohm @ Vdc Power Supply Voltage Range: 1 to 5 Vdc Voltage Rating: Vdc ± 30%

MODEL 31 MP Option Easy installation regarless fluid line conditions Advantage Conventionally, in the case where the pressure transmitter should be vertically installed irrespective of the orientation of the fluid inflow lines, modified flanges are required in addition to the basic flanges. As a result, the modified flanges must be additionally provided. Multi-planar pressure transmitter has been made in an effort to solve the problems occurring in the related art, and an object of this multi planar is to provide a pressure transmitter, capable of being vertically installed without separate adaptor or various types of brackets regardless of the position of each fluid inflow line. Dimension

MODEL 31F Description Wiring 31F is added the totalizing function in 31 transmitter. So it is available to check the flow rate and total flow.» Measuring & Express Flow rate and Total flow» Pulse output by accumulation of total flow» 31F measures the flow rate by using differential pressure so it is not compensated the temperature and static pressure In the case of connecting with Relay or Counter External Appearance Pulse Specification 31F is same shape with 31 but the terminal block is different.» Scaled Pulse : A Single pulse is output for a specified flow amount.» Pulse Width : 10ms, 50ms, 100ms selectable (Negative going pulse)» Duty Cycle : 9 Pulse/sec. Max.» Output Type : Open Collector, 30V, 500mA Max. 1: Pulse out + : Pulse out

GENERAL SPECIFICATIONS 1. 31 Pressure Sensor Range & URL Range Code DP/GP/HP/F Calibrated Span (KPa) Upper Range (URL) (KPa) 0.075 ~ 1.5 1.5 D.P -1.5 AP Lower Range (LRL) (KPa) G.P -1.5 H.P Calibrated Span (KPa) Range(KPa) 3 0.15 ~ 7.5 7.5-7.5-7.5 0.373 ~ 37.3 37.3-37.3-37.3-37.3.5 ~ 50 0 ~ 50 5 1.65 ~ 16.5 16.5-16.5-100 -16.5 15 ~ 1500 0 ~ 1500 6 6.9 ~ 690 690-690 -100-690 5 ~ 500 0 ~ 500 7 0.6~06 6.95~695 06 695-06 -695-100 -100-06 9 0 06.~060 13.7~1370 060 1370-100 -100 inho@0c 6 30 19 79 773 310 770 mmho@0c 15 765 30 1901 70361 107 703097 Range Code 3 5 6 7 KPa 1.5 7.5 37.3 16.5 690 06 695 Kg/cm 0.015 0.076 0.3 1.90 7.036 1.0 70.309 bar 0.015 0.075 0.373 1.65 6.9 0.6 6.95 psi 0.17 1.07 5.1 7.09 100.073 99.93 1000.009 9 060 10.76 06. 999.303 3105 1071 6106.597 0 1370 1.56 13.7 6000.11 16605 1566 116.55. Electrical Specifications Power Supply HART loop resistance 1 to 5 Vdc 50 ~ 550 ohm Output Signal Isolation inhg@0 C 0..15 11.01 55.07 03.75 610.66 036.05 ~ 0 ma dc / HART 500 Vrms (707 Vdc) 3. Performance Specifications Reference Accuracy Ambient Temp. Effect Stability Static Pressure Effects ± 0.075% of Span (0.1URL Span URL) ±[0.05+0.005x(URL/Span)]% of Span (0.01URL Span<0.1URL) ±[0.019%URL+0.15% Span] / C ±0.15% URL for 36 Months ±0.1% of URL per 7MPa (Zero Error) ±0.% of Reading per 7Mpa(Span Error) Ambient Temperature -0 ~ +50C LCD Meter Ambient Temp Humidity Limits -30 ~ +00C 5% ~ 100% RH Process Temperature Limits Power Supply Effects -00C ~ +100C ±0.005% of Span per Volt Zero Shift up to 350Pa No Span Effect Mounting Position Effects. Physical Specifications Isolating Diaphragm Drain & Vent Valve Flange & Adapter O-ring Viton, PTFE Electronic Housing Bolts & Bolting Flange Aluminum (Option:) 30 SST Process Connection Size (Adapter Option) Electrical Connections Weight (excluding Option Items) Pipe Stanchion Type bracket Housing Class 1/ - 1 NPT 1/ 1 NPT 1/ 1 NPT with M 3.9 Kg (Standard) 5.35Kg(SST Housing) Angle or Flat type Waterproof (IP67),

ORDERING INFORMATION MODEL 31 Code Description -D Differential Pressure Transmitter (Static Pressure 13.79 MPa / 000psi) -F Flow Transmitter (on the principle of Differential Pressure Use and only for Head) -G Gauge Pressure Transmitter -H Differential Pressure Transmitter for High Line Pressure (Static Pressure 31.0MPa / 500psi ) -A Absolute Pressure Transmitter DP/GP/HP Calibrated Span Min. to Max Ranges Mounting Flange/ Material Hazardous Location Certifications Electrical Connection Option APT3100-D APT3100-G APT3100-H Upper Range Limits Range APT3100-A 0.075 ~ 1.5 KPa -1.5 KPa -1.5 KPa 1.5 KPa (6.0 inho) 3 0.15 ~ 7.5 KPa -7.5 KPa -7.5 KPa 7.5 KPa (30 inho) 0.373 ~ 37.3 KPa -37.3 KPa -37.3 KPa -37.3 KPa 37.3 KPa (150 inho) 0~50 KPa 5 1.65 ~ 16.5 KPa -16.5 KPa -100KPa -16.5 KPa 16.5 KPa (750 inho) 0~1500 KPa 6 6.9 ~ 690 KPa -690 KPa -100KPa -690 KPa 690 KPa (100 psi) 0~500 KPa 7 0.6 ~ 06 KPa -06 KPa -100KPa -06 KPa 06 KPa (300 psi) 6.95 ~ 695 KPa -695 KPa -100KPa 695 KPa (1000 psi) 9 06. ~ 060 KPa -100KPa 060 KPa (3000 psi) 0 13.7 ~ 1370 KPa -100KPa 1370 KPa (6000 psi) Body Vent Plug M11 M1 HAST - C M13 Monel M1 Tantalum M1 HAST - C HAST - C HAST - C M HAST - C HAST - C Monel M3 HAST - C HAST - C Tantalum Diaphragm K0 Maker Standard (Waterproof : IP67 ) K1 KOSHA Flameproof Approval K KTL Intrinsic Safety Approval E1 ATE(KEMA) Flameproof E ATE(KEMA) Intrinsic Safety FM & FM Canada Explosion proof F FM & FM Canada Intrinsic Safety F1 Fill Fluid Process Connection *AP Lower Range Limit 1 Silicone (DC00) Inert fill fluid (Halocarbon oil) S 1/ - 1 NPT (Standard) 0 1/ - 1 NPT Female (Adapter) 1 1/-1NPT Epoxy-Polyester Painted Aluminum G1/ Epoxy- Polyester Painted Aluminum(Adapter) LPE Lightening Protector (External) M1 LCD Indicator(5digit) MP Multi-Planar LPI Lightening Protector (Internal) K Oil Free Finish F1 Side Vent / Drain Top F Side Vent / Drain Bottom W Way Manifold (SST) : Remote type type WF Flange Type Flange Type Flange Type 3W 3 Way Manifold (SST) : Remote type type 3WF 5W 5 Way Manifold (SST) : Remote type type 6WF BA Stainless Steel Bracket (Angle type) with SST BF Stainless Steel Bracket (Flat type) with SST ST Stainless Steel Housing T Teflon O-Ring (Wetted Part)

Installation With Mounting Bracket Pipe Mounting Bracket Model Angle Type Standard Model MP Model Pipe Mounting Bracket Model Flat Type Standard Model MP Model

Dimensions of Transmitter (mm) Standard Model Intrinsically Safe Model

Smart Pressure Transmitter with Diaphragm Seal MODEL 31L

Smart Pressure Transmitter with Diaphragm Seal MODEL 31L Description of Product The 31L Smart Pressure Transmitter is a micro processor-based high performance transmitter, which has flexible pressure calibration and output, automatic compensation of ambient temperature and process variable, configuration of various parameters, communication with HART protocol. All Data of Sensor(Tag No., Type, Range) is to be input, modified and stored in EEPROM. Features Superior Performance High Reference Accuracy : ±0.075% of Calibrated Span (without seal) Long-Term Stability High Rangeability ( 0 : 1 ) Flexibility Data Configuration with HART Configurator Zero Point Adjustment Reliability Continuous Self-Diagnostic Function Automatic Ambient Temperature Compensation Fail-mode Process Function EEPROM Write Protection CE EMC Conformity Standards (EN5001-, EN500-) Function» Flexible Sensor input : Measuring hydrostatic pressure head and transmitting liquid level»various output: ~0mA(Analog),Digital Signals» Automatic Compensation of Ambient Temperature» Setting Various Parameters : Zero/Span, Fail-mode, Unit, Trim, etc.» Self Diagnostic Function : Sensor, A/D Converter, Memory, Power, etc» Digital Communication with HART protocol, Command.» Explosion-proof Approval & Intrinsic Safety Approval : KOSHA, KTL,CSA, FM & ATE Functional Block Diagram Sensor Part A/D Conversion EEPROM Sensor High Pressure Low Pressure Level Type of Sensor & Configure Tools Selection of Various Pressure - Using Capacitive Pressure Sensor - Screw type. Diaphragm Seal as to process connection method. - User can select measuring sensor for DP, GP. MCU Part Microcomputer o Input Sensor Value o Engineering Units o Rerangement o Filtering / Damping o Diagnostics o Self Compensation o Communications o LCD Display o Configuration Data o LinearizationTable o LinearizationTable o Trimming Constants o Range Value DAC ~0mA HART HART Protocol with Host Transmitter Output - Analog : ~ 0mA DC -Digital : HART Digital Data. Configure Tools - Hand-Held Terminal : portable use in job-site, convenient input, change, review, up-down loading - The Configurator Software Package can be loaded on PC for users convenience

General Specificatons 1. Diaphragm Sealed Sensor Range (Rangeability : 0 : 1) Class Low Level Medium Level High Level Code 5 6 mmho 0 ~ 19 to 0~ 300 0 ~ 960 to 0 ~ 19000 0 ~ 351 to 0 ~ 70000 KPa 0 ~ 1.9 to 0 ~37.3 0 ~ 9. to 0 ~ 16.5 0 ~ 3.5 to 0 ~ 690 11.9 ~ 5 V dc 50 ~550 ohm 0.5 Sec. Output Signal Isolation Turn-on Time ~ 0 ma dc /HART 500 Vrms (707V DC) 5 Sec.. Electrical Specifications Power Supply HART loop resistance Update Time 3. Performance Specifications (without seal) Operating Temp. LCD Meter Operating Temp. -0 ~ +5 C Humidity Limits 5% ~ 9% RH Ambient Temp. Effect ± 0.075% of Span (0.URLFSpan FURL) ± [0.05+0.005x(URL/Span)]% of Span (0.05URLFSpan<0.URL) ± [0.05%URL+0.15% Span]/ C Process Temp. Limit -0 ~ +05 C Stability ± 0.1% URL for 1 Months Power Supply Effects ± 0.005% of Span per Volt Static Pressure Effects ± 0.1% of URL per 7MPa (Zero Error) ± 0.% of Reading per 7Mpa (Span Error) Mounting Position Effects Zero Shift up to 350Pa No Span Effect Reference Accuracy -30 ~ +0 C. Physical Specifications Isolating Diaphragm Drain & Vent Valve Flange & Adapter O-ring Electronic Housing Bolts & Bolting Flange Viton, PTFE Aluminum 30 SST Process Connection Size Diaphragm Seal(Flush/Extended) Electrical Connections Weight (only transmitter) Pipe Stanchion Type bracket Housing Class 1/ - 1 NPT or 3 / 3 or 1/ 1 NPT with M 3.9 Kg Angle or Flat type Waterproof (IP67) 5. Hazardous Location Certifications Option Korea Standards Approval Flameproof Approval : Ex d IIC T6 (KOSHA) Intrinsic Safety Approval : Ex ia IIC T5 (KTL) Overseas Standards Approval CSA Explosion proof Approval FM Explosion proof Approval ATE Flame proof Approval

Dimensional Drawing (mm) MODEL 31LFD For Flush Diaphragm Seal and Direct Mount Type Transmitter Flange Size : 0mm (3 inch) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb 9 9 9 D 190 10 15 00 00 b 9 1 0 d 0 19 3 k 15.5 16.5 150 160 1 160 b 0.5 16 1 d k 10.5 17 19 0 1 f D 17 17 16 13 x 13 f d 9 10 96 x 15 10 Flange Size : 50mm ( inch) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb 59 D 150 165 59 155 59 165 0

Ordering Information MODEL NO. 31 Ranges Mounting Flange Size/Material Mounting Flange Rating Wetted Parts Material Diaphragm/Others Fill Fluid Materials of Construction Low Side Electrical Connection Hazardous Locations Certifications Option Code LFD 5 6 C S C3 S3 A1 A J1 J D1 D S PT H T 7 CS SS W N 1 K0 K1 K E1 *E C1 *C F1 *F M1 W C6 K Description Flush Diaphragm Seal and Direct Mount Type Transmitter 0-19 to 0-300mmHO (0-1.9 to 0-37.3 KPa) 0-960 to 0-19000mmHO (0-9. to 0-16.5 KPa) 0-351 to 0-70000mmHO (0-3.5 to 0-690 KPa) -inch (50mm) C.Steel -inch (50mm) SST 3-inch (0mm) C.Steel 3-inch (0mm) SST ANSI Class 150 ANSI Class 300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 DIAPHRAGM OTHERS PTFE + Hastelloy C-76 Tantalum FILL FLUID TEMPERATURE LIMITS D.C Silicone 00-0 to 05 (-0 to 00 ) D.C Silicone 70 0 to 315 (3 to 600 ) FLANGE VENT/DRAIN VALVE C.Steel without Process Adapter (1/-1 NPT on the cover flange) with 1/-1 NPT Process Adapter () ELECTRICAL CONNECTION MATERIAL 1/-1NPT Epoxy Coated-Aluminum G1/ Epoxy Coated-Aluminum Maker Standard (Waterproof : IP67) KOSHA Flameproof Approval : Ex d IIC T6. KTL Intrinsic Safety Approval : Ex ia IIC ATE(KEMA) Flameproof ATE(KEMA) Intrinsic Safety CSA Explosion proof CSA Intrinsic Safety FM Explosion proof FM Intrinsic Safety LCD Indicator LP Lighting Protector SUS 30 Bolts and Nuts ET External Terminal Block Engineering Unit ST Stainless Steel Housing Oil Free Finish Order Note 1: Request to manufacturer for Draft Range, Absolute(small pressure and vacuum) ans items marked * before order.

MODEL 31LED Dimensional Drawing (mm) For Extended Diaphragm Seal and Direct Mount Type Transmitter Flange Size : 0mm (3 inch ) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb b 9 1 0 d 0 19 3 k 15.5 16.5 150 160 1 D 150 b 0 d 165.5 7 155 16 1 19 7 165 0 1 7 7 7 D 190 10 15 00 00 f 1.6 D 17 D5 76 16 13 76 160 13 76 k 10.5 f D D5 9.3 10 96.3 15 10.3 Flange Size : 50mm ( inch ) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb 7 Diaphragm Extension Length Code 5 10 15 0 17 R 50mm ( inch) 100mm ( inch) 150mm (6 inch)

Ordering Information MODEL NO. 31 Range Mounting Flange Size/Material Mounting Flange Rating Extension Length Wetted Parts Material Diaphragm/Others Fill Fluid Materials of Construction Low Side Electrical Connection Hazardous Locations Certifications Option Code -LED 5 6 x C S C3 S3 A1 A J1 J D1 D 05 10 15 S PT H T 7 CS SS W N 1 K0 K1 K E1 *E C1 *C F1 *F M1 W C6 K Description Extended Diaphragm Seal and Direct Mount Type Transmitter 0-19 to 0-300mmHO (0-1.9 to 0-37.3 KPa) 0-960 to 0-19000mmHO (0-9. to 0-16.5 KPa) 0-351 to 0-70000mmHO (0-3.5 to 0-690 KPa) -inch (50mm) C.Steel -inch (50mm) SST 3-inch (0mm) C.Steel 3-inch (0mm) SST ANSI Class 150 ANSI Class 300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 50mm (in.) 100mm (in.) 150mm (6in.) DIAPHRAGM OTHERS PTFE + Hastelloy C-76 Tantalum FILL FLUID TEMPERATURE LIMITS D.C Silicone 00-0 to 05 (-0 to 00 ) D.C Silicone 70 0 to 315 (3 to 600 ) FLANGE VENT/DRAIN VALVE Plated C.Steel without Process Adapter (1/-1 NPT on the cover flange) with 1/-1 NPT Process Adapter () ELECTRICAL CONNECTION MATERIAL 1/-1NPT Epoxy Coated-Aluminum G1/ Epoxy Coated-Aluminum Maker Standard (Waterproof : IP67) KOSHA Flameproof Approval : Ex d IIC T6. KTL Intrinsic Safety Approval : Ex ia IIC ATE(KEMA) Flameproof ATE(KEMA) Intrinsic Safety CSA Explosion proof CSA Intrinsic Safety FM Explosion proof FM Intrinsic Safety LCD Indicator LP Lighting Protector SUS 30 Bolts and Nuts ET External Terminal Block Engineering Unit ST Stainless Steel Housing Oil Free Finish Order

MODEL 31LFC Dimensional Drawing (mm) For Flush Diaphragm Seal and Capillary Type Transmitter Flange Size : 0mm (3 inch) Flange Rating Mb D b d k 190 0 15.5 10 9 16.5 9 15 00 1 19 3 150 160 9 00 1 ANSI Class150 9 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 f d 17 x 0 17 16 13 160 13 k f d x 9 DIN PN 5/0 Flange Size : 50mm ( inch) Flange Rating Mb ANSI Class150 D b 150 0 59 10.5 0 165 ANSI Class300 d.5 17 16 JIS 10K 59 155 19 10 96 1 JIS 0K DIN PN 10/16 59 DIN PN 5/0 165 0 1 15 10

Ordering Information MODEL NO. 31 Ranges Mounting Flange Size/Material Mounting Flange Rating Wetted Parts Material Diaphragm/Others Fill Fluid Code -LFC 5 6 x C S C3 S3 A1 A J1 J D1 D S PT H T 7 Capillary Length (m) Materials of Construction Electrical Connection Hazardous Locations Certifications Option CS SS 1 K0 K1 K E1 *E C1 *C F1 *F M1 W C6 K P BA BF CA CF Description Flush Diaphragm Seal and Capillary Type Transmitter (Two remote Seal) 0-19 to 0-300mmHO (0-1.9 to 0-37.3 KPa) 0-960 to 0-19000mmHO (0-9. to 0-16.5 KPa) 0-351 to 0-70000mmHO (0-3.5 to 0-690 KPa) 50mm (-inch) C.Steel 50mm (-inch) SST 0mm (3-inch) C.Steel 0mm (3-inch) SST ANSI Class 150 ANSI Class 300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 DIAPHRAGM OTHERS PTFE + Hastelloy C-76 Tantalum FILL FLUID TEMPERATURE LIMITS D.C Silicone 00-0 to 05 (-0 to 00 ) D.C Silicone 70 0 to 315 (3 to 600 ) Capillary Length from 1 to 1mm (Example for 3m : 03) FLANGE VENT/DRAIN VALVE Plated C.Steel ELECTRICAL CONNECTION MATERIAL 1/-1NPT Epoxy Coated-Aluminum G1/ Epoxy Coated-Aluminum Maker Standard (Waterproof : IP67) KOSHA Flameproof Approval : Ex d IIC T6. KTL Intrinsic Safety Approval : Ex ia IIC ATE(KEMA) Flameproof ATE(KEMA) Intrinsic Safety CSA Explosion proof CSA Intrinsic Safety FM Explosion proof FM Intrinsic Safety LCD Indicator LP Lighting Protector SUS 30 Bolts and Nuts ET External Terminal Block Engineering Unit ST Stainless Steel Housing Oil Free Finish PVC Coating on SST Armored Stainless Steel Bracket (Angle type) with SST Bolts Stainless Steel Bracket (Flat type) with SST Bolts Painted Steel Mounting Bracket (Angle Type) with SST Bolts Painted Steel Mounting Bracket (Flat Type) with SST Bolts Order

Dimensional Drawing (mm) MODEL 31LEC For Extended Diaphragm Seal and Capillary Type Transmitter Flange Size : 0mm (3 inch ) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb 7 7 7 D 190 10 15 00 00 b 9 1 0 d 0 19 3 k 15.5 16.5 150 160 1 160 b 0.5 16 1 d k 10.5 17 19 0 1 f 1.6 d 17 d5 76 x 16 13 76 13 76 d5 x Flange Size : 50mm ( inch ) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb 7 D 150 165 7 155 7 165 Diaphragm Extension Length Code 5 10 15 0 f d 9 10 96 15 10 R 50mm ( inch) 100mm ( inch) 150mm (6 inch)

Ordering Information MODEL NO. 31 Ranges Mounting Flange Size/Material Mounting Flange Rating Extension Length Wetted Parts Material Diaphragm/Others Fill Fluid Code -LEC 5 6 x C S C3 S3 A1 A J1 J D1 D 5 10 15 S PT H T 7 Capillary Length (m) Materials of Construction Electrical Connection Hazardous Locations Certifications Option CS SS 1 K0 K1 K E1 *E C1 *C F1 *F M1 W C6 K P BA BF CA CF Description Extended Diaphragm Seal and Capillary Type Transmitter (Two Remote Seal) 0-19 to 0-300mmHO (0-1.9 to 0-37.3 KPa) 0-960 to 0-19000mmHO (0-9. to 0-16.5 KPa) 0-351 to 0-70000mmHO (0-3.5 to 0-690 KPa) 50mm (-inch) C.Steel 50mm (-inch) SST 50mm (-inch) C.Steel 50mm (-inch) SST ANSI Class 150 ANSI Class 300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 50mm (in.) 100mm (in.) 150mm (6in.) DIAPHRAGM OTHERS PTFE + Hastelloy C-76 Tantalum FILL FLUID TEMPERATURE LIMITS D.C Silicone 00-0 to 05 (-0 to 00 ) D.C Silicone 70 0 to 315 (3 to 600 ) Capillary Length from 1 to 1mm (Example for 3m : 03) FLANGE VENT/DRAIN VALVE Plated C.Steel ELECTRICAL CONNECTION MATERIAL 1/-1NPT Epoxy Coated-Aluminum G1/ Epoxy Coated-Aluminum Maker Standard (Waterproof : IP67) KOSHA Flameproof Approval : Ex d IIC T6. KTL Intrinsic Safety Approval : Ex ia IIC ATE(KEMA) Flameproof ATE(KEMA) Intrinsic Safety CSA Explosion proof CSA Intrinsic Safety FM Explosion proof FM Intrinsic Safety LCD Indicator LP Lighting Protector SUS 30 Bolts and Nuts ET External Terminal Block Engineering Unit ST Stainless Steel Housing Oil Free Finish PVC Coating on SST Armored Stainless Steel Bracket (Angle type) with SST Bolts Stainless Steel Bracket (Flat type) with SST Bolts Painted Steel Mounting Bracket (Angle Type) with SST Bolts Painted Steel Mounting Bracket (Flat Type) with SST Bolts Order

Dimensional Drawing (mm) MODEL 31LFS For Flush Diaphragm Seal and Capillary Type Transmitter Flange Size : 0mm (3 inch) Flange Rating Mb D b d k 190 0 15.5 10 9 163.5 9 15 00 19 3 150 160 9 00 1 0 1 160 ANSI Class150 f 9 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 d x 17 17 16 13 13 Dimensional Drawing (mm) Flange Rating ANSI Class150 Mb b 150 0 59 DIN PN 5/0 k f d 9 10.5.5 155 17 19 10 96 1 59 165 0 x 16 59 JIS 0K DIN PN 10/16 d 0 165 ANSI Class300 JIS 10K D 1 15 10

Ordering Information MODEL NO. Code 31 -LFS Ranges Mounting Flange Size/Material Mounting Flange Rating Wetted Parts Material Diaphragm/Others Fill Fluid 6 7 x C S C3 S3 A1 A J1 J D1 D S PT H T 7 Capillary Length (m) Materials of Construction Electrical Connection Hazardous Locations Certifications Option CS SS 1 K0 K1 K E1 *E C1 *C F1 *F M1 W C6 K P BA BF CA CF Description Flush Diaphragm Seal and Capillary Type Transmitter (One Remote Seal) 0-351 to 0-70000mmHO (0-3.5 to 0-690 KPa) 0-10565 to 0-11300mmHO (0-103. to 0-06 KPa) 0-3517 to 0-7030mmHO (0-3. to 0-695 KPa) 50mm (-inch) C.Steel 50mm (-inch) SST 0mm (3-inch) C.Steel 0mm (3-inch) SST ANSI Class 150 ANSI Class 300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 DIAPHRAGM OTHERS PTFE + Hastelloy C-76 Tantalum FILL FLUID TEMPERATURE LIMITS D.C Silicone 00-0 to 05 (-0 to 00 ) D.C Silicone 70 0 to 315 (3 to 600 ) Capillary Length from 1 to 1mm (Example for 3m : 03) FLANGE VENT/DRAIN VALVE Plated C.Steel ELECTRICAL CONNECTION MATERIAL 1/-1NPT Epoxy Coated-Aluminum G1/ Epoxy Coated-Aluminum Maker Standard (Waterproof : IP67) KOSHA Flameproof Approval : Ex d IIC T6. KTL Intrinsic Safety Approval : Ex ia IIC ATE(KEMA) Flameproof ATE(KEMA) Intrinsic Safety CSA Explosion proof CSA Intrinsic Safety FM Explosion proof FM Intrinsic Safety LCD Indicator LP Lighting Protector SUS 30 Bolts and Nuts ET External Terminal Block Engineering Unit ST Stainless Steel Housing Oil Free Finish PVC Coating on SST Armored Stainless Steel Bracket (Angle type) with SST Bolts Stainless Steel Bracket (Flat type) with SST Bolts Painted Steel Mounting Bracket (Angle Type) with SST Bolts Painted Steel Mounting Bracket (Flat Type) with SST Bolts Order

Dimensional Drawing (mm) MODEL 31LES For Extended Diaphragm Seal and Capillary Type Transmitter Flange Size : 0mm (3 inch ) Flange Rating Mb ANSI Class150 D b d k 190 0 15.5 7 DIN PN 10/16 1.6 d 17 d5 x 76 10 9 16.5 7 15 00 1 19 3 150 160 16 13 76 7 00 1 160 13 76 b 0.5 16 1 d k 10.5 17 f d d5 9.3 19 10 96.3 x 0 1 15 10.3 ANSI Class300 JIS 10K JIS 0K f 0 DIN PN 5/0 Flange Size : 50mm ( inch ) Flange Rating ANSI Class150 ANSI Class300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 Mb 7 D 150 165 7 155 7 165 Diaphragm Extension Length Code 5 10 15 0 R 50mm ( inch) 100mm ( inch) 150mm (6 inch)

Ordering Information MODEL NO. Code 31 -LES Ranges Mounting Flange Size/Material Mounting Flange Rating Extension Length Wetted Parts Material Diaphragm/Others Fill Fluid 6 7 x C S C3 S3 A1 A J1 J D1 D 5 10 15 S PT H T 7 Capillary Length (m) Materials of Construction Electrical Connection Hazardous Locations Certifications Option CS SS 1 K0 K1 K E1 *E C1 *C F1 *F M1 W C6 K P BA BF CA CF Description Extended Diaphragm Seal and Capillary Type Transmitter (One Remote Seal) 0-351 to 0-70000mmHO (0-3.5 to 0-690 KPa) 0-10565 to 0-11300mmHO (0-103. to 0-06 KPa) 0-3517 to 0-7030mmHO (0-3. to 0-695 KPa) 50mm (-inch) C.Steel 50mm (-inch) SST 50mm (-inch) C.Steel 50mm (-inch) SST ANSI Class 150 ANSI Class 300 JIS 10K JIS 0K DIN PN 10/16 DIN PN 5/0 50mm (in.) 100mm (in.) 150mm (6in.) DIAPHRAGM OTHERS PTFE + Hastelloy C-76 Tantalum FILL FLUID TEMPERATURE LIMITS D.C Silicone 00-0 to 05 (-0 to 00 ) D.C Silicone 70 0 to 315 (3 to 600 ) Capillary Length from 1 to 1mm (Example for 3m : 03) FLANGE VENT/DRAIN VALVE Plated C.Steel ELECTRICAL CONNECTION MATERIAL 1/-1NPT Epoxy Coated-Aluminum G1/ Epoxy Coated-Aluminum Maker Standard (Waterproof : IP67) KOSHA Flameproof Approval : Ex d IIC T6. KTL Intrinsic Safety Approval : Ex ia IIC ATE(KEMA) Flameproof ATE(KEMA) Intrinsic Safety CSA Explosion proof CSA Intrinsic Safety FM Explosion proof FM Intrinsic Safety LCD Indicator LP Lighting Protector SUS 30 Bolts and Nuts ET External Terminal Block Engineering Unit ST Stainless Steel Housing Oil Free Finish PVC Coating on SST Armored Stainless Steel Bracket (Angle type) with SST Bolts Stainless Steel Bracket (Flat type) with SST Bolts Painted Steel Mounting Bracket (Angle Type) with SST Bolts Painted Steel Mounting Bracket (Flat Type) with SST Bolts Order

Smart Transmitter with Diaphragm Seal Direct Mount MODELType 31LFD/LED Two Remote MODELType 31LFC/LEC One Remote MODELType 31LFS/LES

Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL 300

Standard Flush Mount SST Housing Description of Product Function The 3 Smart Pressure Transmitter is a micro processorbased high performance transmitter, which has flexible pressure calibration and output, automatic compensation of ambient temperature and process variable, configuration of various parameters, communication with HART protocol. All Data of Sensor (Tag No., type, range etc.) is to be input, modified and stored in EEPROM.» Flexible Sensor Input : GP, AP, Flush Mount» Various Output : ~ 0mA, Digital Signals» Setting Various Parameters : Zero/Span, Trim, Unit, Fail-mode, etc.» Self Diagnostic Function : Sensor, Memory A/D Converter, Power, etc.» Digital Communication with HART protocol» Explosion-proof Approval & Intrinsic Safety Approval : ATE,FM, FM Canada, GOST, KOSHA, KTL, etc.» Marine Certificate : ABS, LR, BV, DNV Functional Block Diagram Sensor Part A/D Conversion EEPROM Piezoelectric Sensor * Gauge Pressure * Absolute Pressure MCU Part Microprocessor Input Sensor Value Engineering Units Re-range (Zero / Span) Zero Point Adjustment DA Trimming Damping / Filtering LCD Engineering Mode Diagnostics Self Compensation Communications LCD Display Configuration Data ~0m A DAC HART HART Protocol with Host

Features Function» Superior Performance High Accuracy : ±0.075% of Calibrated Span (option : ±0.0% of Calibrated Span) Long-Term Stability High Rangeability (100:1)» Range and Sensor Limits Refer to Table 1.» Zero and Span Adjustment Limits Zero and span values can be set anywhere within the range limits stated in Table 1. Span must be greater than or equal to the minimum span stated in Table 1.» Flexibility Measuring GP, AP Data Configuration with HART configurator» Reliability Continuous Self-Diagnostic Function Automatic Ambient Temperature Compensation Fail-mode Process Function EEPROM Write Protection CE EMC Conformity Standards (EN5001-, EN500-) Transmitter Description 3 Pressure transmitter can be easily configured from any host that support the HART protocol.» Basic Setup Operational Parameters. ~0mA Points (Zero/Span) Damping Time : 0.5 ~ 60 sec Tag : alphanumeric characters Descriptor : 16 characters Message : 3 characters. Date : day/month/year» Calibration and Trimming Lower/Upper Range (zero/span) Sensor Zero Trimming Zero Point Adjustment DAC Output Trimming Transfer Function Self-Compensation» Self-Diagnosis and Others CPU & Analog Module Fault Detection Communication Error Fail-mode Handling LCD Indication Temperature Measurement of Sensor Module» Output (Analog Current and Digital Data) Two wire ~0mA user-configurable for linear. digital process value superimposed on ~0mA signal, available to any host that conforms to the HART protocol» Power Supply & Load Requirement External power supply required. Transmitters operate on 1 to 5Vdc * 50 ohm load-- 17.5 Vdc * up to a 550 ohm load -- Vdc Max. Loop Resistance = ( E - 1 ) / 0.0 (E = Power Supply Voltage) Voltage Range : 1 to 5 Vdc Voltage Rating : Vdc ±30% Loop Load 0 ~ 1500 ohm -- Operation 50 ~ 550 ohm -- HART Communications» EMC Conformity Standards EMI (Emission) EN5001-:1993 EMS (Immunity) EN500-:1995» Failure Mode Fail High : Current 1.1 ma Fail Low : Current 3.7 ma» Storage Temperature -0 C to 5 C (without condensing)» Process Temperature Limits (Range codes and approval codes may effect limits) -0 C to 10 C ( -10 to )» Isolation Input/output isolated to 500Vrms (707 Vdc)» Working Pressure Limits (silicone oil) Model G -100 ~ 300KPa - # 3-100 ~ 3000 KPa - # 0 ~ 10,500KPa - # 5 0 ~ 0,000 KPa - # 6 0 ~ 75,000 KPa - # 7 Model A 0 ~ 55 KPa - # 0 ~ 3000 KPa - # 5 0 ~ 550 KPa - # 6

Physical Specifications Function» Wetted Materials Isolating Diaphragms :, Tantalum, HAST-C» Non-wetted materials Fill Fluid : Silicone oil (DC00) Electronics Housing : Aluminum, SST316L(option) Flameproof and Waterproof (IP67) Cover O-ring : Buna-N Paint : Epoxy-Polyester or Polyurethane Mounting Bracket : 30SST with U-bolt (30SST) for -inch pipe Nameplate : 30 SST» Process Connections 1/-1 NPT Female 1/-1 NPT (option)» Electrical connections 1/-1 NPT conduit with M Screw Terminals» Change main parameter by Button Change Unit Change Upper range value Change Lower range value Change the Damping Second Select the Decimal Place Zero Trim Zero Adjustment» 5 Digit LCD Express all pressure unit. Use 5 digit. Select decimal place (0 to ) User define unit function Hazardous Location Certifications» KOSHA Approvals K1 Code : * KOSHA: Korea Occupational Safety & Health Agency Flameproof for Class I, Zone 1 : Ex d IIC T6, IP67 Ambient Temperature : -0 to 60 C Max. Process Temperature : 0 C Power Supply : Max. 5 Vdc Output : to 0 ma + HART, Max. ma» ATE Approvals E1 Code : CE 03 II G Ex d IIC T6, T5 or T Operating Temperature: -0 C Tamb +60 C T6 for process 5 C ; T5 for process 100 C T 130 C 3 ATE Certification is according to the below standards : EN 60079-0 : 006 EN 60079-1 : 007» KTL Certification K Code : * KTL: Korea Testing Laboratory Intrinsic Safety: Ex ia IIC T6 Ambient Temperature : -0 to 60 C Ui=30Vdc, Ii=00mA, Pi=0.9W, Ci=7nF, Li=9μH» FM & FM Canada Approvals F1 Code : * FM: Factory Mutual explosion proof * FM Canada: Canadian requirements Explosion proof for Class I, Division 1 Groups A, B, C and D Dust-ignition proof for Class II, Division 1, Groups E, F and G Dust-ignition proof for Class II, Division 1 T6, see instruction for temperature code if process temperature above 5 C Ambient Temperature : -0 to 60 C Enclosure: indoors and outdoors, NEMA Type Conduit seal required within 1 for Group A only. Nonincendive for Class I, Division, Groups A, B, C & D; Class II, Division, Groups E, F & G; and Class III, Division 1, Temperature Code T Ambient Temperature : -0 to 60 C Enclosure: indoors and outdoors, NEMA Type Moving within Menu : Zero Moving to below Menu : Span Moving Top Menu : Zero+Span

Connection Diagram of Signal, Power, HHT for Transmitter Exploded Drawing of Model 3

General Specification 1. Model 3 G/APressure Sensor Range (Rangeability = 100 : 1) 3 5 6 7 Range (KPa) -100~150-100 ~ 1,500 0 ~ 5,000 0 ~ 5,000 0 ~ 60,000 3 G Calibrated Span (KPa) 1.5~150 15 ~ 1,500 50 ~ 5,000 50 ~ 5,000 600 ~ 60,000 3 - A Range 0 ~ 50 0 ~ 1,500 0 ~,500.5 ~ 50 15 ~ 1,500 5 ~,500. Electrical Specifications 1 to 5 Vdc 50 ~ 550 ohm Power Supply HART Loop Resistance Output Signal Isolation ~ 0 ma dc / HART 500 Vrms (707 Vdc) 3. Performance Specifications Reference Accuracy Ambient Temp. Effect ± 0.075% of Span (0.1URL Span URL) ± [0.05+0.005x(URL/Span)]% of Span (0.01URL Span<0.1URL) ± [0.019%URL+0.15% Span] / 0C Ambient Temperature -0 C ~ +5 C LCD Meter Ambient Temp -30 C ~ + 0 C Humidity Limits 5% ~ 100% RH Process Temp. Limit -0C ~ +10 C Power Supply Effect ± 0.005 % of Span per Volt Stability ± [0.15%URL for 36 months. Physical Specifications Isolating Diaphragm Electronic Housing Aluminum Housing Class Waterproof (IP67) Process Connection Size Electrical Connections Pipe Stanchion Type Bracket Weight (excluding options) 1/ 1 NPT Female 1/ 1 NPT with M Angle or Flat type 1.7 kg (standard).3kg(sst Housing)

Ordering Information MODEL 300 Range Mounting Flange Material Hazardous Location Certifications Fill Fluid Process Connection Electrical Connection Option Code -G -F -H 3 5 6 7 M11 *M1 *M13 *M1 K0 K1 E1 F1 1 * S O 1 M1 LPI K W BA BF ST Description Gauge Pressure Transmitter (reference accuracy : 0.075 % of span ) Flush Mount Pressure Transmitter Absolute Pressure Transmitter (reference accuracy : 0.075 % of span) G/F A Range (KPa) Min.Span (KPa) Range (KPa) Min. Span (KPa) -100~150 1.5-100 ~ 1,500 15 0 ~ 50.5 0 ~ 5,000 50 0 ~ 1500 15 0 ~ 5,000 50 0 ~ 500 5 0 ~ 60,000 600 DIAPHRAGM OTHER HAST-C Tantalum HAST - C HAST-C Maker Standard (Waterproof : IP67 ) KOSHA Flameproof Approval KTL Intrinsic Safety Approval K ATE (KEMA) Exposion proof ATE(KEMA) Intrinsic Safety E FM & FM Canada Explosion proof FM & FM Canada Intrinsic Safety F Silicone (DC 00) Inert fill (Halocarbon Oil) 1/ 1 NPT Female (standard) 1/ - 1 NPT Female (adapter) 1/-1NPT Epoxy-Polyester Painted Aluminum G1/ Epoxy-Polyester Painted Aluminum (Adapter) LCD Indicator Lightening Protector (Internal) Lightening Protector (External) LPE Oil Free Finish way manifold Remote type Stainless Steel Bracket (Angle type) with SST Bolts Stainless Steel Bracket (Flat type) with SST Bolts Stainless Steel Housing Example : 3-G5-M11-K0-1-S-1-M1 Note 1 : Request to manufacturer for Draft Range, Absolute (small pressure and vacuum) and Items marked * before order.

Dimension of Transmitter (mm) Standard Model Flush Mount Model Intrinsically Safe Model

Smart Temperature Transmitter MODEL 1 &

Model 1 Model Description of Product Function The Smart Temperature Transmitter is a microprocessor-based high performance transmitter, which has flexible sensor input and output, automatic compensation of ambient temperature and process parameters, configuration of various parameters, communication with HART protocol. All Data of Sensor (Tag No., type, range etc.) is to be input, modified and stored in EEPROM.»Flexible Sensor input: RTD, T/C, mv, Ohm»Various output: ~0mA(Analog), Digital Signals»Automatic Compensation by Linearization table in which user can modify the various necessary values»automatic Compensation of Ambient Temperature»Setting Various Parameters: Zero/Span, Unit, Fail-mode, Trim, etc.»self Diagnostic Function: Sensor, A/D Converter, Memory, Power, etc.»digital Communication with HART protocol»flameproof Approval and Intrinsic Safety Approval: KOSHA, KTL,ATE,FM, GOST(1)»Marine Certificate: ABS, LR, DNV, BV FUNCTIOL BLOCK DIAGRAM SensorADC Part Sensor Cold Junction Compensation User-Selectable Temperature Sensor RTD (W, 3W, W) T/C (Thermocouple) mv Ohm Isolation MCU Part Microprocessor Range Value (Zero/Span) Input Sensor Value Engineering Units Damping / Filtering Linearization Table Zero Point Adjustment DA Trimming Self Compensation Configuration Data Diagnostics LCD Display HART Communications ~0mA DAC HART HART Protocol with Host

Features» Superior Performance Excellent Accuracy (Refer to Page ) Long-Term Stability (Refer to Page )» Flexibility Selection of various T/C, RTD, mv, Ohm Data Configuration with HART configurator Transmitter Description» Sensor Inputs The model 1 and are compatible with a variety of temperature sensors, including W, 3W and Wire RTDs, thermocouples, and other resistance and millivolt inputs (see Page 6). The sensor part module converts the temperature sensor into the digital value. The MCU module calculates the process temperature value based on the digital value. The sensor type and configurationare software-selectable using the Hand-Heldterminal and PC configurator. The sensor modules include the following features The software of the transmitter compensates for the thermal effects, improving performance. Precise input compensation during operation Is achieved with temperature and voltage or resistance correction coefficients that are characterized over the range of temperature sensor and stored in the EEPROM memory. Input sensor type - RTD (Pt-100 ohm): W, 3W, Wire - Thermocouple: B, E, J, K, N, R, S, T type - mv: -10 ~ 75mV - Ohm: 0 ~ 30 Ω» Reliability Automatic Compensation: Linearization of sensor input, Ambient temperature compensation Continuous Self Diagnostic Fail-mode Process function EEPROM Write Protection I/O Isolation: Grounded Thermocouple CE EMC Conformity Standards (EN5001-,EN500-)» Basic Setup Temperature Transmitter can be easily configured from any host that support the HART protocol. Configuration consists of setting the following transmitter operational parameters. Sensor Type Number of sensor input wires and 0mA Points (Zero/Span) Engineering Units Damping Time Tag: alphanumeric characters Descriptor: 16 characters Message: 3 characters Date: day / month / year» Calibration and Trimming Lower/Upper Range (zero/span) Sensor Linearization Zero Point Adjustment DAC Output Trimming Self-Compensation» Self-Diagnosis and Others CPU & Analog Module Fault Detection Communication Error Fail-mode Handling LCD Indication (for model 1) Model 1 Transmitter Field Wiring and Sensor Wiring Diagrams

Performance Specifications Function Specifications» Reference Accuracy (Refer to Table 1)» Range and Sensor Limits (Refer to Table 1)» Stability RTDs. ±0.1% of Reading or 0.15 C, whichever is greater, for months Thermocouples ±0.1% of Reading or 0.15 C, whichever is greater, for 1 months» Zero and Span Adjustment Limits Zero and span values can be set anywhere within the range limits stated in Table 1. Span must be greater than or equal to the minimum span stated in Table 1» Output (Analog Current and Digital Data) Two wire ~0mA, Digital process value superimposed on ~0mA signal, available to any host that conforms to the HART protocol» Repeatability ±0.05% of span» Ambient Temperature Effect (per 1 C change in ambient temperature. Sensor Type Pt 100(a=0.0035) Pt 100(a=0.003916) NIST Type B NIST Type E, J, K, N NIST Type R, S, T Digital Accuracy W, 3W, Wire RTD 0.003 C Thermocouple 0.06 C 0.005 C+0.0005% of reading D/A effect 0.00% of Span 0.00% of Span 0.015 C If reading 00 C 0.01 C - 0.003% of reading if not» Power Supply Effect Less than ±0.005% of Span per Volt» Update Time and Turn-On Time Update Time: 0.5 seconds Turn-On Time: 5 seconds» Failure Mode The value to which the transmitter drives its output in failure is as follows Fail High: Current 1.75 ma Fail Low: Current 3.75 ma» Power Supply & Load Requirement External power supply required. * 50 ohm load-- 17.5 Vdc * up to a 550 ohm load -- Vdc Max. Loop Resistance = (E-1) / 0.0 (E = Power Supply Voltage) Voltage Range: 1 to 5 Vdc Voltage Rating: Vdc ±30%» Loop Load 0 to 1500 Ω for Operation 50 to 550 Ω for HART Communications» Ambient Humidity Limits 5% ~ 100%RH (Relative Humidity)» Ambient Temperature Limits -0 C ~ 5 C (without condensing for model 1) -0 C ~ 5 C (without condensing for model ) -30 C ~ 0 C (with LCD module)» Storage Temperature -0 C ~ 5 C (without condensing) -0 C ~ 5 C (without condensing for model )» Isolation Input / output isolated to 500Vrms (707 Vdc)

Physical Specifications Hazardous Location Certifications» Electrical connections 1/-1 NPT conduit with M3.5 Screw Terminals» KOSHA Approvals K1 Code : * KOSHA: Korea Occupational Safety & Health Agency Flameproof for Class I, Zone 1 : Ex d IIC T6, IP67 Ambient Temperature: -0 to 60 C Power Supply: Max. 5 Vdc Output: to 0 ma + HART, Max. ma» Materials of Construction Electronics Housing: Low-copper aluminum Flameproof and waterproof (IP67) Paint: Epoxy-Polyester or Polyurethane Cover O-ring: Buna-N Mounting Bracket: 30SST with U-bolt (30SST) for -inch pipe Nameplate: 30 SST» Weight 1. kg below (Standard-excluding options).6kg (SST Housing-excluding options)» ATE Approvals E1 Code : CE 03 II G Ex d IIC T6, T5 or T Operating Temperature: -0 C Tamb +60 C T6 for process 5 C; T5 for process 100 C T for process 130 C FM & FM Canada Approvals F1 Code : * FM: Factory Mutual explosion proof * FM Canada: Canadian requirements Explosion proof for Class I, Division 1 Groups A, B, C and D Dust-ignition proof for Class II, Division 1, Groups E, F and G Dust-ignition proof for Class II, Division 1 T6, see instruction for temperature code if process temperature above 5 C Ambient Temperature: -0 to 60 C Enclosure: indoors and outdoors, NEMA Type Conduit seal required within 1 for Group A only. Nonincendive for Class I, Division, Groups A, B, C & D; Class II, Division, Groups E, F & G; and Class III, Division 1, Temperature Code T Ambient Temperature: -0 to 60 C Enclosure: indoors and outdoors, NEMA Type Supply Voltage:11.9~Vdc Model Transmitter Field Wiring and Sensor Wiring Diagrams

General Specifications 1. Temperature Sensor Range & Accuracy Sensor Type Sensor Reference Input Range Minimum Span Digital Accuracy D/A Accuracy Of Span RTD KSC 1603-1991 (a=0.0035) DIN JISC 160-191 (a=0.00391) Pt-100 Pt-100-00 ~ 650 C ±0.17 C 15 C -00 ~ 650 C ±0.03% ±0.16 C Thermocouple NIST Type B 100 ~ 1,0 C ±0.77 C NIST Type E 00 ~ 1,000 C ±0.0 C NIST Type J 00 ~ 1,00 C ±0.5 C NIST Type K 00 ~ 1,350 C ±0.35 C KSC160-19 5 C NIST Type N 00 ~ 1,300 C ±0.0 C NIST Type R 0 ~ 1,760 C ±0.60 C NIST Type S 0 ~ 1,70 C ±0.50 C NIST Type T -00 ~ 00 C ±0.5 C Millivolt Input -10 ~ 75 mv mv ± 0.01 mv Ohm Input 0 ~ 30 Ω 0 Ω ± 0.35 Ω < Note > 1) RTD input: a= 0.0035: KS, JIS, DIN, IEC, a= 0.00391: US. ) Thermocouple input: KSC 160-19, JISC 160-191, ANSI MC96.1-19 3) Digital accuracy for Type B is ± 3.0 C from 100 to 300 C ) Digital accuracy for Type K is ± 0.50 C from -10 to -90 C ±0.03% Ambient Temperature Effects ( per 1 C change in Ambient temperature) Sensor Type Digital Accuracy D/A effect per Pt 100 (a=0.0035) 0.003 C RTD w, 3w, -Wire Pt 100 (a=0.003916) NIST Type B 0.06 C 0.00% of Span NIST Type E, J, K, N 0.005 C+0.0005% of reading Thermocouple 0.015 C If reading NIST Type R, S, T 0.01 C - 0.003% of reading if not. Electrical Specifications Power Supply HART Loop Resistance Voltage Range : 1 to 5 Vdc Voltage Rating : Vdc ±30% 50 ~ 550 ohm( Vdc) Output Signal ~ 0 ma dc / HART Isolation 500 Vrms (707 Vdc) 3. Performance Specifications Accuracy Stability for year Ambient Temp. Effect Repeatability Refer to item No.1 ±0.1% of Reading or 0.1 C whichever is greater ±0.05% of Span/10 C ±0.05% of Span Operating Temp LCD Meter Operating Tem -0 ~ +5 C -30 ~ +0 C Humidity Limits Power Supply Effect 5% ~ 100% RH(1) ±0.005% of Span/V Weight (excluding Option Items) Pipe Stanchion Type bracket Housing Class 1.Kg below (standard).6kg (SST Housing) Angle or Flat Type Waterproof (IP67). Physical Specifications (for model 1) Electrical Connections 1/-1NPT(w/M3.5) Electronics Housing O-rings Aluminum Buna-N

Ordering Information MODEL NO. Code -S Single Element Model 1 -D* Dual Elements Housing Materials and Electrical Connection 1 1/ - 1 NPT G1/ (Adapter) 1 1/ - 1 NPT Epoxy Coated-Aluminum G1/ (Adapter) Epoxy Coated-Aluminum H Horizontal Type V Vertical Type Process Connection Sensor Position Sensor Type Hazardous Locations Certifications Option R M Mili-volt K0 Maker Standard (Waterproof : IP67) K1 KOSHA Flameproof Approval : Ex d IIC T6. K KTL Intrinsic Safety Approval : Ex ia IIC T5 E1 ATE Flameproof F1 FM & FM Canada Explosion proof *F M1 FM & FM Canada Intrinsic safety LCD Indicator BA Stainless Steel Bracket (Angle type) with SST Bolts BF Stainless Steel Bracket (Flat type) with SST Bolts ST Stainless Steel Housing Code -S -D* Housing Materials Hazardous Locations Certifications Sensor Type Sensor Fail Mode Ex) : -S-1-K0-A3-D Note : * before order. Epoxy Coated-Aluminum Epoxy Coated-Aluminum RTD (PT100[Ω]) / (with Wires) Thermocouple / (with Type) Resistor A T 1 LPE Example : 1-S-K1-1-1-H-A3-M1-BA Note 1 : * before order. MODEL NO. Model Description Assembly Option (Element/Well) Lightening Protector (External) Description Single Element Dual Element ( Order, Request to manufacturer if necessary) 1 Plastic KO Maker Standard A RTD (PT100[Ω]) / (with Wires) T Thermocouple / (with Type) R Resistor M Mili-volt D Downscale U Upscale

Connection Diagram of Signal, Power, HHT for Transmitter Dimension Dimensions of Transmitter (mm) Model 1 Model

Distributor: Bont Technologies GmbH Salzstr: 1 1335 Lüneburg www.bont-tech.com info@bont-tech.com